QUALITY MANAGEMENT SYSTEM (QMS)

Company Name Company Logo


Title: In-House Verification/Calibration WI

Instrument/Equipment: Calibration/Verification: Verification

IS/ISO Reference (if any): N/A


Rectangular V-Block (L x W x H) = 50 x 25 x 30 mm
Calibration/Verification Period (Frequency): 6 Months

Initial Treatment Instructions (e.g.: Soaking/Cleaning): Cleaning


(1) Clean the V-Block by using any of the rust-preventive Oils like Starrett M-1 or Boeshield T-9 before taking it for Verification.

(2) Later allow it ro Cool down for few minutes.

(3) If Oil is not available, Clean the V-Block by using Soft Paper like Towel to avoid Damages.

(4)

(5)

Master Instruments Used for Verification/Calibration:


(1) Profile Projector, AAP/BP02/QA/CAL/01. (Calibration Expires On: 20.02.2020).

(2) Master Magnetic V-Block, AAP/BP02/QA/CAL/02. (Calibration Expires On: 20.02.2020).

(3)

(4)

Error Acceptance Range/Criteria:


Acceptable Error: On "+" Side 0.05 mm & On "-" Side 0.05 mm.

i.e. L = 49.95 mm to 50.05 mm; W = 24.95 mm to 25.05 mm & H = 29.95 mm to 30.05 mm.

Rejection Criteria:
(1) The Rectangular V-Block shall be Rejected if any one of the Dimensions measured is Out of Spec w.r.t. Error Acceptance Criteria.

(2) The Rectangular V-Block shall be Rejected if it is found in Damged condition.

Procedure:

(1) Place the Rectangular V-Block on to the Profile Projector's Measuring Table. Make sure that, Profile Projector is cleaned.

(2) Use Magnetic V-Block for orign alignment/parallel alignment (0-0 Coordinates) of Rectangular V-Block.

(3) Measure the Length, Width, Height and record the same in Inspection/Verification Report. At-least take a minimum of 3 Trials.

(4) Check all readings whether lies within the Specification or not.

(5) If all Dimensions are Ok, Accept the V-Block by taking Approval from QA Manager. Mention Verification Due On Date on the Report.

(6) Attach the Calibration Reports of Master Instruments to the Reports of Rectangular V-Block for Traceability.

(7) Shall collect & keep all Traceability Certificates from Lab Agency against Calibration Reports of Master Instruments.

(8) QA Manager/Calibrator shall Sign off the report as Verified & found Ok (along with Date) at the Back of Calibration/Verification Reports.

(9) If the Readings are Out of Spec, then the V-Block shall be Rejected & Scrapped in contolled manner.

(10) Rectangular V-Block can be used for a Maximum of 3 years & later shall be Scrapped as there are chances of worn-out.

Doc No.: XXX/XXX/XX | Rev No.: XX Prepared By: Mr.Name Sheet Author: Mr.Name
Rev Date: XX.XX.XXXX Approved By: Mr.Name Page: 1 of 1.
Issue No.: XX | Issue Date: XX.XX.XXXX