Table 3

Combustion Calculations - Btu Method


INPUT CONDITIONS FUEL
1 1 Theo Air, lb/100 lb 1 H2O, lb/100 lb
1 Excess air: at burner/leaving boiler/econ, % by weight 30/30/30 5 Ultimate Analysis 6 fuel 7 fuel
2 Entering air temperature, F 81,0000 Constituent % by weight K1 [15] x K1 K2 [15] x K2
260,701
3 Reference temperature, F 81,0000 A C 22,6500 11,5100 5
4 Fuel temperature, F 81,0000 B S 0,0500 4,3200 0,2160
5 Air temperature leaving air heater, F 0,0000 C H2 2,9000 34,2900 99,4410 8,9400 25,9260
6 Flue gas temperature leaving (excluding leakage), F 284,0000 D H2O 51,0000 1,0000 51,0000
7 Moisture in air, lb/lb dry air 0,0130 E N2 0,2000
8 Additional moisture, lb/100 lb fuel 0,0000 F O2 20,1000 -4,3200 -86,8320
9 Residue leaving boiler/economizer, % Total 0,0000 G Ash 3,1000
1 273,526
0 Output, 1,000,000 Btu/h 20,5714 H Total 100,0000 Air 5 H2O 76,9260
Corrections for sorbent (from Chapter 10, Table 14 if used)
1 Additional theorecal air, lb/10,000 Btu Table 14, Item 1 15477,214
1 [21] 0 8 Higher heating value (HHV), Btu/lb fuel 0
1 CO2 from sorbent, lb/10,000 Btu Table 14, Item 1
2 [19] 0 9 Unburned carbon loss, % fuel input 3,0000
1 H2O from sorbent, lb/10,000 Btu Table 14, Item 2
3 [20] 0 0 Theoretical air, lb/10,000 Btu [16H] x 100 / [18] 1,7673
1 Spent sorbent, lb/10,000 Btu Table 14, Item 2
4 [24] 0 1 Unburned carbon, % of fuel [19] x [18] / 14,500 3,2022

COMBUSTION GAS CALCULATIONS, Quantity/10,000 Btu Fuel Input


2
2 Theoretical air (corrected), lb/10,000 Btu [20] - [21] x 1151 / [18] +[11] 1,5291
2
3 Residue from fuel, lb/10000 Btu ([15G] + [21]) x 100 / [18] 0,0407
2
4 Total residue, lb/10,000 Btu [23] + [14] 0,0407
A At Burners B Infiltration C Leaving Furnace D Leaving Blr/Econ
2
5 Excess air, % by weight 30 0 30 30
2
6 Dry air, lb/10,000 Btu (1 + [25] / 100) x [22] 1,9879 1,9879
2
7 H2O from air, lb/10,000 Btu [26] x [7] 0,0258 0,0258 0,0258 0,0258
2
8 Additional moisture, lb/10,000 Btu [8] x 100 / [18] 0,0000 0,0000 0,0000 0,0000
2
9 H2O from fuel, lb/10,000 Btu [17H] x 100 / [18] 0,4970 0,4970
3
0 Wet gas from fuel, lb/10,000 Btu (100 - [15G] - [21]) x 100 / [18] 0,6054 0,6054
3
1 CO2 from sorbent, lb/10,000 Btu [12] 0,0000 0,0000
3
2 H2O from sorbent, lb/10,000 Btu [13] 0,0000 0,0000 0,0000
3
3 Total wet gas, lb/10,000 Btu Summation [26] through [32] 2,6191 2,6191
3
4 Water in wet gas, lb/10,000 Btu Summation [27] + [28] + [29] + [32] 0,5229 0,5229 0,5229 0,5229
3
5 Dry gas, lb/10,000 Btu [33]- [34] 2,0963 2,0963
3
6 H2O in gas, % by weight 100 x [34] / [33] 19,9635 19,9635
3
7 Residue, % by weight [9] x [24] / [33] 0,0000 0,0000

EFFICIENCY CALCULATIONS, % Input from Fuel


Losses
3
8 Dry gas, % 0,0024 x [35D] x ([6] - [3]) 1,0213
3
9 Enthalpy of steam at 1 psi, T = [6] H1 = (3,958E - 5 x T + 0,4329) x T + 1062,2 1188,3360
4
0 Enthalpy of water at T = [3] H2 = [3] - 32 49,0000
4 Water from fuel, as fired
1 % [29] x ([39] -[40]) / 100 5,6628
4
2 Moisture in air, % 0,0045 x [27D] x ([6] - [3]) 0,0236
4
3 Unburned carbon, % [19] or [21] x 14500 / [18] 3,0000
4
4 Radiation and convection, % ABMA curve, Chapter 23 0,3000
4
5 Other, % (include manufacturers margin if applicable) 0,3000
4
6 Sorbent net losses, % if sorbent is used From Chapter 10, Table 14, Item [41] 0,0000
4
7 Summation of losses, % Summation [38] through [46] 23,7943
Credits
4
Heat in dry air, %
8 0,0024 x [26D] x ([2] - [3]) 0,0000
4
Heat in moisture in air, %
9 0,0045 x [27D] x ([2] - [3]) 0,0000
5
Sensible heat in fuel, %
0 (H at T[4] - H at T[3])*100 / [18] 0,0000 0,0000
5
Other, %
1
5
Summation of credits, %
2 Summation [48] through [51] 0,0000
5
3
Efficiency, % 100 - [47] + [52] 76,2057

KEY PERFORMANCE PARAMETERS Leaving Furnace Leaving Blr/Econ


5
4 Input from fuel, 1,000,000 Btu/h 100 x [10] / [53] 26,9946
5
5 Fuel rate, 1000 lb/h 1000 x [54] / [18] 1,7441494
5
6 Wet gas weight, 1000 lb/h [54] x [33] / 10 7,0702 7,0702
5
7 Air to burners (wet), lb/10,000 Btu (1 + [7]) x (1 + [25A] / 100) x [22] 2,0137
5
8 Air to burners (wet), 1000 lb/h [54] x [57] / 10 5,4360
5 Heat available, 1,000,000 Btu/h [54] x {([18] - 10,30 x [17H]) / [18] - 0,005 x ([44]
9 Ha 66,0000 Btu/h + [45]) + Ha at T[5] x [57] / 10,000} 25,8904
6
0 Heat available/lb wet gas, Btu/lb 1000 x [59] / [56] 3661,8965
6
1 Adiabatic flame temperature, F From Chapter 10, Fig. 3 at H = [60], % H2O = [36] 3560,0000
Flujo Masico de Combustible Flujo Masico de Combustible Ahorro en Combustible
(Inicial) (kg/h) (Final) (kg/h) (kg/h)

880,31 791,13 89,18

0,750925
791,1328776 118,7631885
866971,2764
1213759787

24,71658752
2,965990502