Sie sind auf Seite 1von 3

Page : 1 of 1

Prince Center, 9th Floor. Jl. Jend. Sudirman 3-4, Acceptance Test Data sheet Project name : FEEDING CONVEYOR SYSTEM
Jakarta 10220, BELT FEEDER 1 Eqp. Number : BF #1
Telp: (021) 573 5131 FEEDING CONVEYOR SYSTEM Units Name : BELT FEEDER 1
Fax : (021) 573 5133 PT. INDEXIM COALINDO Date : 11-Dec-17
Condition and performances
Equipment installed
Remark
Descriptions Belt OFF and Empty Belt ON and Empty Belt ON Loaded Acceptance
Symbol Units Design Actual
Design Data ;
Conveyor Capacity Qt Ton/hour 1200 1000
Belt Width BW mm 2000 2000
Speed v m/s 0.9 0.9
Angle of inclination g Degree 0 0
Belt Condition X2/BW/X1 X2/BW/X1 X2/BW/X1 X2/BW/X1
Head Pulley / 100 / 2000 / 100 / 100 / 2000 / 100 / 100 / 2000 / 100 ±25 Note : As long the edge of belt is not saging with

Snub Pulley / 100 / 2000 / 100 / 100 / 2000 / 100 / 100 / 2000 / 100 ±25 guide roller

Bend Pulley #1 (N/A) / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A ±25

Bend Pulley #1 (N/A) / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A ±25

Take Up Pulley / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A ±25

Tail Pulley / 100 / 2000 / 100 / 100 / 2000 / 100 / 100 / 2000 / 100 ±25

Gear Data Capacity Full Load Out put Capacity Out put Start / Op. Current Voltage
Motor Data
Torque speed RPM Ratio kW speed RPM (Ampere)

PHD9085R3 Design 73.1 18.5 80:1 M2QA280M Design 69 1480 - 380


RL-80 Actual Install 73.1 18.5 80:1 4A Actual Install 90 1480 - 380

2A

2RH 1RH
2RV
1RV
1A

2A

Minutes from early start operation


Motors MORNING (09.00-10.00) DAY (13.00-14.00) AFTERNOON (15.00-16.00) Remark
0 30 60 240 270 300 360 390 420
Temperatures ºC 32.5/32.4 35.6/32.7 39.3/38.1 39.5/40.8 41.2/40.8 40.5/40.6 39.1/38.5 38.4/38.5 38/38.5

Minutes from early start operation


Bearing
Temperatures ºC MORNING (09.00-10.00) DAY (13.00-14.00) AFTERNOON (15.00-16.00) Remark
0 30 60 240 270 300 360 390 420
Head Bearing 31.2/32.1 35.6/32.6 38/38.5 40.4/41 41.1/40.6 40.9/40.2 38.3/38.1 38.5/38.7 38/38.5
Snub Bearing 30.4/32.5 34.8/32.4 36.4/38.6 40.7/41.1 41/40.8 40.3/40.4 38.1/38.5 38.2/38.5 37.7/38.1
Takeup Bearing
Bend Bearing #1
Bend Bearing #2
Tail Bearing 28.5/30.8 32.8/31.6 37.3/34.9 40.8/41 40.9/40.8 41.9/40.8 38.4/38.5 38.6/38.4 37.6/38.3

PT. INDEXIM COALINDO PT. INDEXIM COALINDO PT. SIKO TECHNO


ACKNOWLEDGE ACKNOWLEDGE MAIN CONTRACTOR

Thomas Daniel Ardian


(Approved) (Reviewed) (Prepared)
Page : 1 of 1
Prince Center, 9th Floor. Jl. Jend. Sudirman 3-4, Acceptance Test Data sheet Project name : FEEDING CONVEYOR SYSTEM
Jakarta 10220, BELT FEEDER 1 Eqp. Number : BF #1
Telp: (021) 573 5131 FEEDING CONVEYOR SYSTEM Units Name : BELT FEEDER 2
Fax : (021) 573 5133 PT. INDEXIM COALINDO Date : 11-Dec-17
Condition and performances
Equipment installed
Remark
Descriptions Belt OFF and Empty Belt ON and Empty Belt ON Loaded Acceptance
Symbol Units Design Actual
Design Data ;
Conveyor Capacity Qt Ton/hour 1200 1000
Belt Width BW mm 2000 2000
Speed v m/s 0.9 0.9
Angle of inclination g Degree 0 0
Belt Condition X2/BW/X1 X2/BW/X1 X2/BW/X1 X2/BW/X1
Head Pulley / 100 / 2000 / 100 / 100 / 2000 / 100 / 100 / 2000 / 100 ±25 Note : As long the edge of belt is not saging with

Snub Pulley / 100 / 2000 / 100 / 100 / 2000 / 100 / 100 / 2000 / 100 ±25 guide roller

Bend Pulley #1 (N/A) / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A ±25

Bend Pulley #1 (N/A) / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A ±25

Take Up Pulley / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A / N/A ±25

Tail Pulley / 100 / 2000 / 100 / 100 / 2000 / 100 / 100 / 2000 / 100 ±25

Gear Data Capacity Full Load Out put Capacity Out put Start / Op. Current Voltage
Motor Data
Torque (KNm) speed RPM Ratio kW speed RPM (Ampere)

PHD9085R3 Design 73.1 18.5 80:1 M2QA280M Design 69 1480 - 380


RL-80 Actual Install 73.1 18.5 80:1 4A Actual Install 90 1480 - 380

2A

2RH 1RH
2RV
1RV
1A

2A

Minutes from early start operation


Motors MORNING (09.00-10.00) DAY (13.00-14.00) AFTERNOON (15.00-16.00) Remark
0 30 60 240 270 300 360 390 420
Temperatures ºC 32.6/32.3 33.5/32 38/34.1 41./40.4 39.8/39.3 40.7/39.8 39.3/36.4 38.3/37.6 38.6/37.1

Minutes from early start operation


Bearing
Temperatures ºC MORNING (09.00-10.00) DAY (13.00-14.00) AFTERNOON (15.00-16.00) Remark
0 30 60 240 270 300 360 390 420
Head Bearing 32.8/32.1 31.7/32.2 34.3/36 40.3/39.2 41.1/38.6 40.9/40.2 39.3/36.8 38.6/36.8 38.1/36.1
Snub Bearing 32.1/32.4 32.3/31.8 33.5/32.8 40.1/39.7 41.8/39.8 40.3/40.4 39.5/35.9 38.3/37.6 38.6/36.1
Takeup Bearing
Bend Bearing #1
Bend Bearing #2
Tail Bearing 28/27.4 33.5/29.6 33.7/27.7 41./40.4 40.9/39.6 41.9/40.8 39.8/36 38.4/37.1 38.7/364

PT. INDEXIM COALINDO PT. INDEXIM COALINDO PT. SIKO TECHNO


ACKNOWLEDGE ACKNOWLEDGE MAIN CONTRACTOR

Thomas Daniel Ardian


(Approved) (Reviewed) (Prepared)
Page : 1 of 1
Prince Center, 9th Floor. Jl. Jend. Sudirman 3-4, Acceptance Test Data sheet Project name : FEEDING CONVEYOR SYSTEM
Jakarta 10220, BELT FEEDER 1 Eqp. Number : BF #1
Telp: (021) 573 5131 FEEDING CONVEYOR SYSTEM Units Name : FEEDING CONVEYOR
Fax : (021) 573 5133 PT. INDEXIM COALINDO Date : 11-Dec-17
Condition and performances
Equipment installed
Remark
Descriptions Belt OFF and Empty Belt ON and Empty Belt ON Loaded Acceptance
Symbol Units Design Actual
Design Data ;
Conveyor Capacity Qt Ton/hour 2200 2000
Belt Width BW mm 1500 1500
Speed v m/s 3.0 3.0
Angle of inclination g Degree 0 9
Belt Condition X2/BW/X1 X2/BW/X1 X2/BW/X1 X2/BW/X1
Head Pulley / 100 / 1500 / 100 / 100 / 1500 / 100 / 100 / 1500 / 100 ±25 Note : As long the edge of belt is not saging with

Snub Pulley / 100 / 1500 / 100 / 100 / 1500 / 100 / 100 / 1500 / 100 ±25 guide roller

Bend Pulley #1 (N/A) / 100 / 1500 / 100 / 100 / 1500 / 100 / 100 / 1500 / 100 ±25

Bend Pulley #1 (N/A) / 100 / 1500 / 100 / 100 / 1500 / 100 / 100 / 1500 / 100 ±25

Take Up Pulley / 100 / 1500 / 100 / 100 / 1500 / 100 / 100 / 1500 / 100 ±25

Tail Pulley / 100 / 1500 / 100 / 100 / 1500 / 100 / 100 / 1500 / 100 ±25

Gear Data Capacity Full Load Out put Capacity Out put Start / Op. Current Voltage
Motor Data
Torque (KNm) speed RPM Ratio kW speed RPM (Ampere)

PHA9050R2 Design 15.3 92.5 16:1 M2QA280 Design 69 1480 - 380


RLF-16 Actual Install 15.3 92.5 16:1 M4A Actual Install 90 1480 - 380

2A

2RH 1RH
2RV
1RV
1A

2A

Minutes from early start operation


Motors MORNING (09.00-10.00) DAY (13.00-14.00) AFTERNOON (15.00-16.00) Remark
0 30 60 240 270 300 360 390 420
Temperatures ºC 32.6/31.9 32.4/32.1 32.7/31.7 41/39.8 40.1/39.2 39.5/39.2 39.6/38.1 38.9/38.2 38.1/38.2

Minutes from early start operation


Bearing
Temperatures ºC MORNING (09.00-10.00) DAY (13.00-14.00) AFTERNOON (15.00-16.00) Remark
0 30 60 240 270 300 360 390 420
Head Bearing 32.8/32.4 31.4/30.6 32.7/32.2 40.7/39.2 39.8/38.7 39.1/37.5 39/37.6 38.6/36.8 38.1/38.6
Snub Bearing 31.9/32.1 32.4/32.1 32.8/31.8 41.2/39.3 39.3/37.6 38.9/37.6 39.4/37.3 38.3/37.6 38/38.5
Takeup Bearing 30.3/31.5 32.4/32.4 32.2/31.6 41.4/39.8 39.5/37.8 39.3/37.2 39.1/37.3 38.5/38.7 37.7/38.1
Bend Bearing #1 32.3/32.1 32.3/32.4 32.8/31.8 41.3/38.9 39.6/38.7 39.2/37.3 39.4/37.3 38.2/38.5 38.1/38.3
Bend Bearing #2 32.4/32.4 32.5/32.2 32.6/32.6 41.3/38.9 39.6/38.7 39.2/37.3 39.4/37.3 38.2/38.5 38.1/38.3
Tail Bearing 29.2/28.1 32.1/32.3 33.5/29.6 40.1/37.9 39.1/37.1 39.3/37.2 39.3/37 38.4/37.1 37.7/38.1

PT. INDEXIM COALINDO PT. INDEXIM COALINDO PT. SIKO TECHNO


ACKNOWLEDGE ACKNOWLEDGE MAIN CONTRACTOR

Thomas Daniel Ardian


(Approved) (Reviewed) (Prepared)