0W 435W
for Li-Ion mode-C and 24 Volt either L1: 0W
L2: 0W
L1: 155W
L2: 135W
name name
75%
+
950W
visible in this drawing. of the VE.Bus BMS to Remote H terminal. 340W
25.6V 13.2A
DC Power
-155W
The BMS GND is not connected
to prevent ground loops.
Ground comes through the
VE-BUS UTP cable.
color control
BMS ON/OFF
MAIN SWITCH-4
OFF
VRM
WORLD
MAIN DC
DISTRIBUTION
ON
MAIN INCOMING
Maximum 5mA POSITIVE AC BREAKERS
BUSBAR TOWARDS
QUATTRO'S
MEGA
ARGOFET BATTERY ISOLATOR ALTERNATOR (Lithium Proof)
xxxA Load
QUATTRO'S QUATTRO'S
Starter Battery + INPUT-1 INPUT-2
MEGA Charge light
xxxA Load
IGNITION
CYRIX Li CHARGE 230 MEGA
D+
name name
CYRIX Li
xxxA
100A 3 Output
ARGOFET Battery Isolator 200A 3 Output 24V-80A
CHARGE SHORE POWER
230 CONNECTION
Li-DISTRIBUTION MEGA
100A Alternator CEE Form 5 pole 16A
POS. NEG.
POSITIVE ISOLATION TRANSFORMER OR
BUSBAR
60 AMPERE
INCLUDING NECESSARY
285060F
Conn-J+O AC IN-2 L1 Conn-J+O AC IN-2 L1 BREAKERS.
MAIN SWITCH-1 MPPT Conn-A+P AC IN-1 L1 Conn-A+P AC IN-1 L1
Battery Pre Main Fuses OFF
KEEP POSITIVE BATTERY CABLES Conn-J+O AC IN-2 L2 Conn-J+O AC IN-2 L2
ALL AT THE SAME LENGTH ! Quattro-1 Batt + Conn-A+P AC IN-1 L2 Conn-A+P AC IN-1 L2
ANL
Conn-J+O AC IN-2 L3
MEGA
350A ON 400A Conn-A+P AC IN-1 L3
QUATTRO 5KW/24V/230V AC QUATTRO 5KW/24V/230V AC QUATTRO 5KW/24V/230V AC
Quattro-1 Batt + INVERTER/CHARGER MASTER L1 INVERTER/CHARGER FOLLOWER L2 INVERTER/CHARGER FOLLOWER L3
Quattro-2 Batt +
ANL victron energy victron energy victron energy
BLUE POWER BLUE POWER BLUE POWER
AC in 2
AC out 1
AC out 2
bulk
I on
O off
overload AC in 1
AC in 2
AC out 1
AC out 2
bulk
I on
O off
overload AC in 1
AC in 2
AC out 1
AC out 2
bulk
I on
O off
overload
absorption low battery absorption low battery absorption low battery
charger only charger only charger only
OFF float temperature float temperature float temperature
.battery charger .sinewave inverter .transfer switch .battery charger .sinewave inverter .transfer switch .battery charger .sinewave inverter .transfer switch
VOLT
VOLT
VOLT
24 |5000 |120 24 |5000 |120 24 |5000 |120
AMP
AMP
AMP
VA
AC transfer capacity: 2x100A | Inverter 230V
VA
AC transfer capacity: 2x100A | Inverter 230V
VA
AC transfer capacity: 2x100A | Inverter 230V
CE CE CE
ANL MEGA
ON 400A
Quattro-3 Batt +
VE-BUS MAINS DETECTOR
BMS 0.5A build inside Quattro-L1
BMV 100mA
BMV-712 SMART AC input-1
CCGX 1A
BMV-712 SMART
AC input-2
5x20mm BATTERY MONITOR
victron energy
FUSES BLUE POWER
MAIN V
SETUP SELECT
VE Bus mains detector VE Bus link Quattro's VE Bus link Quattro's Conn-D+P AC OUT-2 L3
VE Bus to CCGX VE Bus to CCGX VE Bus to CCGX Conn-C+P AC OUT-1 L3
Conn-D+P AC OUT-2 L2 Conn-D+P AC OUT-2 L2
CENTRAL NEGATIVE BUSBAR Conn-C+P AC OUT-1 L2 Conn-C+P AC OUT-1 L2
Conn-D+P AC OUT-2 L1 Conn-D+P AC OUT-2 L1
Conn-C+P AC OUT-1 L1 Conn-C+P AC OUT-1 L1
CYRIX LI MAIN OUTGOING
BP220 GND BREAKERS
TOWARDS AC
CCGX
DISTRIBUTION
ARGO FET
Load-
Load-
Load-
Load- Q1 Conn-G Batt+
L1 L2 L3 L1 L2 L3
Load- Q2 Conn-G Batt+ 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF
Q2 Conn-G Batt+
Engine-
4 x Lithium Q3 Conn-G Batt+
25.6V-200Ah
25.6V-200Ah
25.6V-200Ah
25.6V-200Ah
Smart LiFePO4
Smart LiFePO4
Smart LiFePO4
Smart LiFePO4
Lithium
Lithium
Lithium
Lithium
victron energy
victron energy
victron energy
Alternator-
BLUE POWER
BLUE POWER
BLUE POWER
BLUE POWER
QUATTRO'S QUATTRO'S
Smart LiFePO4 Q1 Conn-F Batt- Q1 Conn-F Batt- OUTPUT-1 OUTPUT-2
Quattro 3 phase setup programming Recommended AC Out-2 cable/breaker size Quattro's Recommended AC Out-1 cable/breaker size Quattro's Recommended DC cable/fuse size Quattro's Recommended AC IN-1 & AC IN-2 WARNING
cable/breaker size Quattro's
The 3 phase setup programming has to be AC Out-2 only is available when power is With Power assist each Quattro can add 0-5 m cable length: 4 x 50SQmm 230/400 VOLT IS EXTREMELY HAZARDOUS
KEEP NEGATIVE BATTERY CABLES completed with Victron's VE.Bus Quick present on AC IN-1 or AC IN-2. During 5KW to the output load per phase when 5-10 m cable length: 4 x 95SQmm AC IN-1 & AC IN-2 both must be protected DO NOT TOUCH ANY LIVE WIRED
ALL AT THE SAME LENGTH ! Configure before the VE-Bus BMS assistant battery operation it will be disconnected. needed. Together with the adjustable 100A Cable length stands for the distance between the by a circuit breaker rated at 100A max per PARTS OF THE INSTALLATION !!!
is loaded into each Quattro ! AC Out-2 supports up to 50A per phase and input this all adds up to the max sum of battery connections and the Quattro connections !!! phase or less. This depends heavily on the WHEN IN DOUBT, ALWAYS CONSULT
is adjustable. An Earth leakage with input and output current of 100+21=121A Recommendations are without other loads in the size of the connected power source.The YOUR VICTRON DEALER !!!
Quattro programming with VEConfigure
breaker or a combination MCB/RCD must per phase. An Earth leakage with breaker system and these also should be taken into input currents must be adjusted to fit the
The VE-Bus BMS assistant has to be added be installed on the output. Cable size must or a combination MCB/RCD must be account for proper main battery, main fuse & main size of the connected power source. The
to each Quattro with Victron's VEConfigure be adjusted accordingly. installed on the output. Cable size must be switch cables !!! breaker and cable size for both AC IN-1 &
after completion of the 3 phase setup. adjusted accordingly. Fuse size should be 1x400A or 2x200A per Quattro AC IN-2 should be adjusted accordingly.