Sie sind auf Seite 1von 4

2013 MSJC Anchor Bolt Design

Instructions
1) Blue cells are for user input and can be modified as desired.
2) Beige cells are important output cells, as calculated by the spreadsheet, and cannot be modified.
3) A simple design summary box, located after user input summarizes the adequacy of the current desig
4) All calculations are conducted in US [in-lb] units
5) Invalid user input will be prompted with an error message requiring the user to correct their input.
Design Notes
1) Analysis and subsequent calculations are for a single anchor.
2) Wall thickness is the actual dimension, not a nominal measurement.
3) It is the duty of the designer/user to verify the validity of calculations presented in the spreadsheets.
nd cannot be modified.
equacy of the current design

r to correct their input.

nted in the spreadsheets.


Date:
2013 MSJC Anchor Bolt Design (MM/DD/YYYY)
Allowable Stress Design Face Mounted Anchor

***user input indicated by blue cells

DATA INPUT AND SUMMARY OF DESIGN

Propeties and Geometry


Weather or Soil Exposure no
x
Top or Face Mount Face
**Assumed adequate distance from top/bottom of wall and spacing from
adjacent anchors to develop breakout cone

Anchor Type = bent-bar


Anchor Yield Strength = 36000 psi
Anchor Diameter, db = 3/4 in
Anchor Hook Length, eb = 3.00 in

f'm = 2000 psi


Wall thickness, t = 7.625 in
Edge Distance, lbe =
x Top Mounted Anchor
3.25 in
Net Anchor Area, Ab = 0.334 in 2

Effective Embed. Length, lb = 8.00 in

Loading
Shear Force, Vtotal = 3000 lbs
Offset distance, e = 1.00 in
Dist. From C.L. of Bolt To Edge
4.00 in
of Ledger, x =
Direct Tension Force, Ptotal = 1000 lbs

<<Anchor is inadequate, revise design. See detailed analysis>>

Detailed Analysis

Check minimum embed.

[TMS 402-13 §1.17.6] lb= 8.00 in > lb_min = min(4db,2 in) = 3.00 in <Satisfactory>

Check minimum cover

[TMS 402-13 §1.16.4.1] covermin= 1.50 in

(for top mounted) t - leb =


coveractual= -0.38 in
(for face mounted) t - lb = <Fail, revise embed.>

Total Tension Force Considering Ecc., baf

1900 lbs ***assuming that moment arm is (5/6) of 'd'

Determine Tensile Capacity

h1= 0.00 in s1= 0.00 in A1= 0.00 in2

h2= 0.00 in s2= 0.00 in A2= 0.00 in2

201.06 in2

[TMS 402-13 Eqn. 8-1] Masonry Tensile Breakout 11240 lbs

[TMS 402-13 Eqn. 8-2] Steel Tensile Yield 7214 lbs

[TMS 402-13 Eqn. 8-4] Anchor Pullout 6022 lbs

Design Axial Strength 6022 lbs > baf <Satisfactory>

Governing Failure Mode: Pullout

Determine Shear Capacity

16.59 in2

[TMS 402-13 Eqn. 8-6] Masonry Shear Breakout 927 lbs

[TMS 402-13 Eqn. 8-7] Masonry Crushing 1779 lbs

[TMS 402-13 Eqn. 8-8] Anchor Shear Pryout 22479 lbs

[TMS 402-13 Eqn. 8-9] Steel Shear Yielding 2597 lbs

Design Shear Strength 927 lbs < bvf <Fail, revise anchor>

Governing Failure Mode: Breakout

Check Combined Tension and Shear Interaction

[TMS 402-13 Eqn. 8-10] 3.55 > 1.000 <Fail, revise anchor>
Date:
2013 MSJC Anchor Bolt Design (MM/DD/YYYY)
Strength Design Face Mounted Anchor

***user input indicated by blue cells

DATA INPUT AND SUMMARY OF DESIGN

Propeties and Geometry


Weather or Soil Exposure
x
YES
Top or Face Mounted Top
**Assumed adequate spacing from adjacent anchors to allow
no overlap of breakout cones

Anchor Type = headed


Anchor Yield Strength, fy = 60000 psi
Anchor Diameter, db = 1/2 in
Anchor Hook Length, eb = 0 in
**For headed anchor set hook length equal to 0
f'm = 2000 psi
Wall thickness, t = 7.625 in
x Top Mounted Anchor
Edge Distance, lbe = 3.25 in
Net Anchor Area, Ab = 0.142 in2

Effective Embed. Length, lb = 8.00 in

Loading (factored)
Shear Force, Vu = 500 lbs
Offset distance, e = 2.00 in
Dist. From C.L. of Bolt To Edge
of Ledger, x = 4.00 in
Direct Tension Force, Pu = 1000 lbs

<<Anchor design is satisfactory. See detailed analysis>>

Detailed Analysis

Check minimum embed.

[TMS 402-13 §1.17.6] lb= 8.00 in > lb_min = min(4db,2 in) = 2.00 in <Satisfactory>

Check minimum cover


[TMS 402-13 §1.16.4.1] covermin= 1.50 in

(for top mounted) t - leb =


coveractual= 3.25 in <Satisfactory>
(for face mounted) t - lb =

Total Tension Force Considering Ecc., b af

1300 lbs ***assuming that moment arm is (5/6) of 'd'

Determine Tensile Capacity

h1 = 4.75 in s1 = 14.62 in A1= 49.96 in2

h2 = 3.63 in s2 = 13.40 in A2= 34.15 in2

116.95 in2

[TMS 402-13 Eqn. 9-1] Masonry Tensile Breakout ( f = 0.5) 20920 lbs

[TMS 402-13 Eqn. 9-2] Steel Tensile Yield ( f = 0.9) 8520 lbs

[TMS 402-13 Eqn. 9-4] Anchor Pullout ( f = 0.65) N/A lbs

Design Axial Strength 7668 lbs > baf <Satisfactory>

Governing Failure Mode: Anchor Yielding

Determine Shear Capacity

16.59 in2

[TMS 402-13 Eqn. 9-6] Masonry Shear Breakout ( f = 0.5) 2968 lbs

[TMS 402-13Eqn. 9-7] Masonry Crushing ( f = 0.5) 4310 lbs

[TMS 402-13 Eqn. 9-8] Anchor Shear Pryout ( f = 0.5) 41841 lbs

[TMS 402-13 Eqn. 9-9] Steel Shear Yielding ( f = 0.9) 5112 lbs

Design Shear Strength 1484 lbs > bvf <Satisfactory>

Governing Failure Mode: Breakout

Check Combined Tension and Shear Interaction

[TMS 402-13 Eqn. 9-10] 0.506 < 1.000 <Satisfactory>