Sie sind auf Seite 1von 9

Appendix - C Aug-19

Specifications, Technical Requirements & Data Schedules (115kV XLPE Power Cable & FOC) Revision: A

Appendix - C
DATA SCHEDULES

Contents
TABLE-1 ................................................................................................................................................................................... 2
115KV XLPE POWER CABLE ..................................................................................................................................................... 2
TABLE-1 (CONT’D) ................................................................................................................................................................... 3
115KV XLPE POWER CABLE ..................................................................................................................................................... 3
TABLE-1 (CONT’D) ................................................................................................................................................................... 4
115KV XLPE POWER CABLE ..................................................................................................................................................... 4
TABLE-2 ................................................................................................................................................................................... 5
DATA SCHEDULE, SPLICE & TERMINATION FOR 115KV POWER CABLES ................................................................................ 5
TABLE-3 ................................................................................................................................................................................... 6
DATA SCHEDULE FOR LINK BOXES .......................................................................................................................................... 6
TABLE-3 ................................................................................................................................................................................... 7
DATA SCHEDULE FOR LINK BOXES .......................................................................................................................................... 7
TABLE-4 ................................................................................................................................................................................... 8
DATA SCHEDULE FOR SHEATH VOLTAGE LIMITER .................................................................................................................. 8
TABLE-5 ................................................................................................................................................................................... 9
FIBER OPTIC CABLE.................................................................................................................................................................. 9

Page 1 of 9
Appendix - C Aug-19
Specifications, Technical Requirements & Data Schedules (115kV XLPE Power Cable & FOC) Revision: A

TABLE-1
115KV XLPE POWER CABLE
ITEM DESCRIPTION UNITS SPECIFIED PROPOSED

1.0 Manufacturer *
XLPE, Single
2.0 Cable Type
Core
3.0 Applicable Standards *
4.0 Ratings
Nominal Voltage kV 115

Short Circuit Current kA 63

Maximum conductor short circuit current


°C *
temperature,

Maximum permissible continuous conductor


°C *
temperature

Maximum emergency conductor loading temp, °C °C *

5.0 Conductor:
Material - Copper

Cross-sectional area mm2 *

Diameter mm *

Resistance at 25°C Ω/km *

Short circuit capability of conductor in kA for 1 sec kA 63


starting with 90°C conductor temperature up to
maximum short circuit current temperature.

6.0 Conductor shield :


Material - SEMICON

Thermal resistivity, k-m/W *

Conductor Moisture Impervious layer Material - Semi-


conducting
Tape

7.0 Insulation:

Page 2 of 9
Appendix - C Aug-19
Specifications, Technical Requirements & Data Schedules (115kV XLPE Power Cable & FOC) Revision: A

SUPER CLEAN
Material - XLPE

TABLE-1 (CONT’D)
115KV XLPE POWER CABLE
ITEM DESCRIPTION UNITS SPECIFIED PROPOSED
Thermal resistivity, k-m/W *

Dielectric constant (ε) - *

Loss factor (δ) - *

Specific Resistance, (Actual Test Value) MΩ-km *

8.0 Insulation Shield:


Material - SEMICON

Thermal resistivity k-m/W *

9.0 Metallic Shield:

Material - *

Total effective cross-sectional area mm2 *

Resistivity at 20°C Ω-m *

Short circuit capability in kA for 1 sec of the kA 63


metallic shield starting with 90°C conductor
temperature.

10.0 Moisture impervious layer (first layer):

Material - Semi-
Conductive
Swelling
Tape or
Powder

11.0 Moisture impervious layer (second layer):


Material - Semi-
Conductive
Swelling
Tape or
Powder

Page 3 of 9
Appendix - C Aug-19
Specifications, Technical Requirements & Data Schedules (115kV XLPE Power Cable & FOC) Revision: A

TABLE-1 (CONT’D)
115KV XLPE POWER CABLE
ITEM DESCRIPTION UNITS SPECIFIED PROPOSED

12.0 Jacket:

Material (MDPE or HDPE) - *

Overall cable diameter mm *

13.0 Conductive layer:

Material - *

Thickness mm *

Note:

* - data/parameters to be proposed by the VENDOR/MANUFACTURER/SUPPLIER.

Page 4 of 9
Appendix - C Aug-19
Specifications, Technical Requirements & Data Schedules (115kV XLPE Power Cable & FOC) Revision: A

TABLE-2
DATA SCHEDULE, SPLICE & TERMINATION FOR 115KV POWER CABLES

ITEM MATERIAL DESCRIPTION UNITS SPECIFIED PROPOSED

1.0 General:

Applicable Standards - *

Splice Type - *

Termination type - *

2.0 Ratings

Voltage Rating of Splice kV 115

Voltage Rating of Termination kV 115

Maximum Design Voltage to Ground (For 115kV) kV *

Continuous Current Carrying Capability A *

Short Circuit Current Rating (Splice) for 1 sec kA *

Short Circuit Current Rating (Termination) for 1 sec kA *

3.0 Others

Conductor Material (for Splice) - *

Conductor Material (for Termination) - *

Connector Material - *

Connector Type - *

Note:

* - data/parameters to be proposed by the VENDOR/MANUFACTURER/SUPPLIER.

Page 5 of 9
Appendix - C Aug-19
Specifications, Technical Requirements & Data Schedules (115kV XLPE Power Cable & FOC) Revision: A

TABLE-3
DATA SCHEDULE FOR LINK BOXES

ITEM MATERIAL DESCRIPTION UNITS SPECIFIED PROPOSED

1.0 Ratings

Nominal System Voltage kV 115

System Short Circuit Current (sym) at rated system


voltage:

3-phase kA *

Phase-to-phase kA *

1-phase-to-ground kA *

Magnitude of fault current to be carried by links and kA


*
busbars

Duration of fault current sec *

Maximum induced voltage in the sheath due to load V


*
currents

Maximum induced voltage in the sheath due to


system through fault currents:

3-phase kV *

Phase-to-phase kV *

1-phase-to-ground kV *

2.0 Materials

Connecting Links:

Material - *

Size mm2 *

Contact resistance of connections uΩ *

Page 6 of 9
Appendix - C Aug-19
Specifications, Technical Requirements & Data Schedules (115kV XLPE Power Cable & FOC) Revision: A

TABLE-3
DATA SCHEDULE FOR LINK BOXES

ITEM MATERIAL DESCRIPTION UNITS SPECIFIED PROPOSED

Busbar:

Material - *

Size mm2 *

Ground Terminal:

Material - *

Size mm2 *

Enclousure:

Height mm *

Width mm *

Depth mm *

Sheet Material - *

Insulating resistance:

between Links MΩ *

links to ground MΩ *

Note:

* - data/parameters to be proposed by the VENDOR/MANUFACTURER/SUPPLIER.

Page 7 of 9
Appendix - C Aug-19
Specifications, Technical Requirements & Data Schedules (115kV XLPE Power Cable & FOC) Revision: A

TABLE-4
DATA SCHEDULE FOR SHEATH VOLTAGE LIMITER
ITEM MATERIAL DESCRIPTION UNITS SPECIFIED PROPOSED
1.0 Continuous Service Voltage kVrms *

2.0 Rated Voltage kVrms *

3.0 Rated discharge current with 8/20us waveform kApeak *

4.0 High current Impulse (4/10us) withstand kApeak *

5.0 Non-linear Resistor Material - *

6.0 Insulation resistance at 2500Vdc MΩ *

Note:

* - data/parameters to be proposed by the VENDOR/MANUFACTURER/SUPPLIER.

Page 8 of 9
Appendix - C Aug-19
Specifications, Technical Requirements & Data Schedules (115kV XLPE Power Cable & FOC) Revision: A

TABLE-5
FIBER OPTIC CABLE

ITEM DESCRIPTION UNITS SPECIFIED PROPOSED

1.0 Manufacturer *
Single Mode
2.0 Cable Type/MODE
24 Fibers
IEC 60494-1
3.0 Applicable Standards
IEC 60304
4.0 Body Features

Cable Color as per IEC 60304 *

Cable Code G652

No. of Active Loose tubes or buffer 2

No. of Fiber per Loose tube or buffer 12

Outer Diameter mm * -

Storage Temperature °C 40°C-70°C

Installation Temperature °C 40°C-70°C

5.0 Conductor:
Material - FOC

Glass Graded
Fiber Type - Index

No. of fibers - 24

Dia. of strand prior to compaction mm *

Cross-sectional area mm2 *

Diameter mm *

Bend Radius (Installation) mm *

Tensile Strength (Installation) N *

Note:

* - data/parameters to be proposed by the VENDOR/MANUFACTURER/SUPPLIER.

***END OF APPENDIX-C***

Page 9 of 9