NOTES:

1. FOUNDATION IS DESIGNED FOR TOW FLOORS ONLY.


2. S.B.C OF SOIL IS ASSUMED AS 150 KN PER SQ.M.
3. DEPTH OF FOUNDATION IS 1.8m FROM L.N.G.L.
4. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE
IN METERS UNLESS OTHERWISE SPECIFIED.
5. ALL DIMENSIONS ARE FROM UNFINISHED FLOOR LEVEL
/ SURFACE.
6. ALL DIMENSIONS SHALL BE CHECKED AND VERIFIED AT
SCHEDULE OF BEAMS SITE.
7. NO DIMENSIONS TO BE SCALED OFF THE DRAWING.
ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
8. ALL DRAWINGS ARE INTERRELATED AND SHALL BE
READ IN CONJUNCTION WITH OTHER RELEVANT
DRAWINGS.
9. ANY DISCREPANCY FOUND IN THE DRAWING IS TO BE
IMMEDIATELY CLARIFIED WITH THE ENGINEER OR HIS
C K M 2 Y 14 F.B. REPRESENTATIVE AT THE SITE BEFORE
COMMENCEMENT OF RELATED ITEMS OF WORK.
10. ALL ELECTRICAL CONDUITS IN SLABS TO PASS OVER
1060.00 THE SLAB REINFORCEMENT.
10.00 10.00
11. NO ELECTRICAL CONDUITS ARE ALLOWED TO PASS
520.00 520.00
THROUGH COLUMN AND NO OPENING SHOULD BE
LEFT IN THE STRUCTURAL MEMBERS WITHOUT
WRITTEN PERMISSION OF THE ENGINEER.
12. CONCRETE FOR STRUCTURAL MEMBERS SHOULD BE
OF GRADE 25 UNLESS OTHERWISE SPECIFIED.
10.00

10.00
11 11 13. ALL REINFORCEMENTS SHALL BE HIGH YIELD HAVING
CHARACTERISTIC STRENGTH Fy - 415 N/mm2.
14. CONCRETE COVER TO REINFORCEMENT:-
FOUNDATION - 75mm.
COLUMN - 30 T0 40mm.
BEAMS - 40mm., SLABS - 25mm.
520.00

520.00
15. BLOCK WORK BELOW EXTERNAL PLINTH BEAMS
SHOULD BE OF SOLID BLOCKS.
16. IN ALL MASONRY WALLS CONTINUOUS LINTELS OF
MINIMUM SIZE 200x200 & MINIMUM REINFORCEMENT
4Y12 SHOULD BE PROVIDED AT DOOR/WINDOW
1000.00

1000.00
HEIGHT FOR THE FULL LENGTH OF THE WALL PANEL.
17. UNDERGROUND PORTION OF COLUMNS TO HAVE
10 10 EXTRA COVER AS DETAILED.
18. PROVIDE P.C.C. 200mm THICK WITH 100mm
220.00

PROJECTION ALL AROUND.


19. MINIMUM LAP LENGTHS SHOULD BE 50 Dia BUT NOT

460.00
LESS THAN 60 CM.
9 20. CONTINUE BOTTOM REINFORCEMENT OF SLABS AND
BEAMS BEYOND.
240.00

21. PROVIDE ADEQUATE CHAIRS TO SEPERATE TOP AND


BOTTOM REINFORCEMENT OF SLABS, CONTINUOUS
FOOTINGS ETC.
10.00

10.00

8 8 22. IN BEAMS 200 WIDE, MAXIMUM NUMBER OF BARS IN


ONE LAYER IS 3. 20 Dia. PINS (SPACERS) SHOULD BE
PROVIDED SEPERATING TWO LAYERS.

10.00 10.00
520.00 520.00

1060.00

C K M

ENGINEERING CONSULTANTS
C.R.NO.1/59873/2
POST BOX NO. 256
POSTAL CODE 320
BARKA BRANCH
SULTANATE OF OMAN

PENT FLOOR ROOF BEAM & SLAB


RASHID SAID AL HARASSI 3-27-040
-01-520

NAKHAL
RESIDENTIAL TWO + P

PF ROOF BEAM & SLAB

HATIM 13/11/14

1:100

11