Beruflich Dokumente
Kultur Dokumente
V = Vm cos (ωt + θv )
Vm
R I= cos (ωt + θv )
R
Vm2 2R
α = 0; Pavg = = Im
2R
V = Vm cos (ωt + θv )
Vm R
jωL i= cos (ωt + θv )
L
V
= m sin (ωt + θv )
ωL
⇒ θI = θv − π/2 ⇒ Pavg = 0
Vm2
p (t) = sin (2 (ωt + θv ))
2ωL
Electrical energy is transferred back and forth between the load and the source
Z = jωL = ωL]π/2
V
I= ] (θv − π/2)
|Z|
∴ θv − θI → Impedance angle
1
1
−j Z= ] − π/2
ωC
ωC Pavg = 0 as with the inductor
Pavg : Active power that is absorbed by the device and converted to the other forms of energy.
Power transferred between the source and capacitor/inductor remains as electrical energy.
Vm Im
Pavg = cos α
2
where, cos α is called the power factor.
Since α is the impedance angle, which varies from −π/2 to π/2; cos α varies between 0 and
1.
* cos α is the same whether the current leads voltage by α or lags by α - . To distinguish
between the two types of loads, we have lagging power factor or leading power factor.
* Given a source voltage, for the same active power, we need a higher current if PF(power
factor) is smaller.
V ωL
I=√ ] − tan−1 + θv
R R2 + ω2 L2 R
ωL
V θv − θI = tan−1 =α
R
jωL
0 6 α 6 π/2
R −1
α = tan−1
V ωCR
−π/2 6 α 6 0
−j/ωC
2
Vm
−Vm
Vef f = Vm
Example 1.
3Ω j6 Ω
−j2 Ω
p
S = P 2 + Q2
= Vef f Ief f Apparent power Units: VA (Volt Ampere)
3
P is the same irrespective of whether current leads or lags.
jQ p
S = P 2 + Q2
Q
P tan α =
P
r
1
Q=± −1
-j Q P F2
AIb = 0
⇒ AIb∗ = 0
AT Vn = Vb
V T Ib∗ = VnT AIb∗ = 0
X
Vk Ik∗ = 0
k
I1
Vs Z1 Z2
I1 I2
I = I1 + I2
4
Z1 : 50kW induction motor with lagging PF = 0.8. Vs = 230V rms. What should Z2 be so that
PF = 0.95 ?
A low PF is not good as we require a large current for the same active power (V I cos α)
Also there is a larger exchange of reactive power between the source and the load leading
to transmission losses. We can increase the power factor by connecting another load. Make
sure active power is the same in both cases.
S1 :P = 50kW
r
1
Q = +50 − 1 kV AR
P F2
= 37.5 kV AR
We want
r
1
Sw = 50 + j50 − 1 kV A
(0.95)2
= 50 + j16.43 kV A
= S1 + S2
∴ S2 = j (16.43 − 37.5)
= −j21.07 kV A
= V I2∗
21.07 × 103
∴ I2 = j
230
= j91.6 A
V 230
Z2 = = ] − π/2
I2 91.6
= −j2.51 Ω
(capacitive load)