Sie sind auf Seite 1von 11

MicroGuard® 534

Component Overview

¾Display Unit ‐ MG534
¾Computer
¾Boom Reel Assembly
¾Anti‐Two Block Switch

MG500 Series System Overview

1
MG534 Display

Pre‐Alarm Overload Alarm
Horn Bar graph
Erected Attachment Max Capacity
& Information Actual Hookload
Parts of Line & Button
Auxiliary Head
Erected
Winches & Winch 
Boom Angle
Boom Angle
Selection Button
l i
Display Brightness 
Control Radius
Boom Mode  Boom Length
Selection
Information &
Outrigger 
Warning Bar
Configuration
Display Select  Cancel Alarm
Button Operator Settable 
Crane Setup  Alarms
Button Stowed Fly Counterweight

MG500 Computer
Pressure 
Function Kickout Fuse 
Transducers
10Amp

System 
Connectors

I.C.16 System Chip 
Socket

2
Boom Reel Assembly

Boom Reel Internal


Angle Sensor Anti‐Two Block Slip‐
Ring

Extension 
Potentiometer

Terminal 
Strip

Setting Reference Voltages

¾Using a Digital 
Volt/Ohm Meter 
check/set the following 
voltages.
¾Check Drive Voltage for 
¾Check Drive Voltage for
5vdc +/‐ .25vdc

‐DR       +DR
Blue      Red

3
Setting Angle Sensor Reference
Voltage

¾To set the Angle Sensor 
voltage loosen the two 
retaining screws on the 
Angle Sensor and turn the 
Angle Sensor till the correct 
g ( )
voltage is achieved (.5vdc).  

¾Measuring between the 
Blue wire and Green wire.

‐DR       Angle
Blue     Green

Setting Extension Sensor Reference


Voltage

Push down
¾To set Extension pot 
voltage push down on 
spring arm assembly 
and turn large gear till 
correct voltage is 
l i
achieved (.25vdc). 
Measuring between the 
Blue wire and White 
wire.
‐DR     Extension
Blue    White

Anti-Two Block Switch

4
Anti-Two Block Switch Internal

Terminal Strip

Counter‐Balanced 
Weight

Proximity 
Switches

System Self-Test

On initial startup the
LinkBelt Preferred screen 
will appear briefly, then 
the system will initiate a 
self‐test which will last 
approx. 7‐10 seconds.  
Then the system will go
Then the system will go 
to the working screen.

Crane Setup

Pressing the Crane Setup 
button will initiate the 
setup routine.  You must 
complete the entire 
routine to properly setup 
the system.

5
Outrigger/Tire Selection

¾ After pressing the Crane 
Setup button the first 
selection will be for 
outrigger/tire/rigging 
selection.  
¾ Pressing “More” will take 
you to the next selection 
screen.  Pressing it again 
will return you to the 
first screen.

Counterweight Selection

¾ The next step is to 
select counterweight 
options.
¾ If your machine has 
you ac e as
no counterweight 
options this screen 
will automatically be 
skipped.

Boom Mode Selection

¾ The boom must be fully 
retracted in order to 
change boom modes.
¾ If the boom is not fully 
y
retracted then this 
screen will be skipped.

6
Auxiliary Head Selection

¾ Select whether the 
Auxiliary Head is or is not 
installed on the machine

Fly Selection

¾ Select whether there is 
or is not a fly erected on 
the machine.
¾ If there is a fly selected 
y
the next screen will ask 
for the offset angle of 
the fly.

Front Winch Pick Point

¾ Select the appropriate 
pick point (Main Boom, 
Aux, Fly or Not Used) for 
the front winch.
¾ Once the selection has 
been made the screen 
been made the screen
will automatically go to 
the next screen.

7
Rear Winch Pick Point

¾ Select the appropriate 
pick point (Main Boom, 
Aux, Fly or Not Used) for 
the rear winch.
¾ Notice the one less pick 
point selection
point selection.

Stowed Fly Selection

¾ Select any fly or part of 
fly stowed on the side of 
the boom.

Operator Settable Alarms

¾Whenever an Operator 
Settable Alarm is set there 
will be a red bell appear 
on the display letting you 
know there is an alarm set.
¾Enter the Operator 
¾Enter the Operator
Settable Alarms by 
pressing the bell button

8
Operator Settable Alarms

¾ Operator Settable 
Alarms main selection 
screen

Boom Limits

¾ Once the machine has 
been physically moved to  Maximum Length
55.0
OFF
the position to set the 
alarm, press the 
corresponding alarm  55.0 60.0 65.4
25.0
button to set.  Press 
again to turn off the  60.0
Maximum Tip Height
OFF
alarm.

65.4
Maximum Angle
OFF

Minimum Angle
25.0
OFF

Swing Limits

265.0
OFF
SET
¾ Once the machine has 
been physically moved to 
the position to set the  95.0
265.0
alarm, press the 
corresponding alarm  Set both Alarms
button to set.  Press again 
to turn off the alarm.  You 
must set both limits! 95.0
OFF
SET

9
Defined Area

¾Using Length, Angle and 
Swing set the machine 
to the desired right or 
left limit.  Then press 
the corresponding  97.2
button to set the alarm.  
¾You must set both 
limits! Right Area
Right Area
¾Anytime the boom 
exceeds the limit by 
either extending, angle  Left Area
movement or swing the 
alarm will be sounded.

Calibration & Diagnostics

¾ Pressing the Display Select 
button will cause the  A00 B0 C00 D00
following screen to be 
displayed.
¾ Pressing the button beside 
the Error Codes button will 
cause the error codes to be 
displayed in the white box
displayed in the white box.
¾ Pressing the button beside 
the Enter Calibration will take 
you to the Calibration Screen 
and request you input the 
calibration key sequence.

10
Calibration Security Code

Load MicroGuard 534
9.4
Calibration 
1
Angle
Entry Security
72.0 Enter Correct
Radius Key Sequence
9.3 FT
Length
38.0
3

Calibration Menu

¾00 Error Codes
¾01 Crane Data
¾02 Zero Sensor
¾03 Span Sensor
¾04 Swing Pot Load
9.4 00 Error Codes
¾05 Radius/Mom Angle
72.0
¾06 Boom Defl’n Radius Menu Up

¾07 Head Angle 9.3 FT
Length Menu Down
¾08 Attachments 38.0

¾09 Winches
¾10 Rope Limits
¾11 Alarms
¾12 Digital I/O Exit

¾13 Monitor
¾14
¾15 Pressure

Think Safety!

11