Sie sind auf Seite 1von 3

:T LABORATORY SERVICTS

hanical, Metallurgical
I.*SIICS ' BUBBERS
& Corrosion Testing
W*/
- @ww
I Pedect

irr* ',r, Dl Bloch MIDC Chinchwad' Pune 411


019
W*NAWM ceftificate No.TC-5751
The NameToTrust

6 @ trustSerfectlab@yahoo'com 1993-2018
glgm2c;245 81 50, 27 45 47 1

ORIGIiIAI FOR RECTPIEI{T


INVOICE
lil\rorcE ilo INV-16148
OMEGAICEHITIPVf. $D. tlr\rorcE DATE ],2107 l2OL9
U'S' Nagar' tlttaraklrand263 153''
Pbt No. 37, Sec'tor -'t, llE-Pantrragar'
(09917944111)

350.00 1400.00
Fensile tett/s with machining 2oo.0o 1600'00
2 Bend test/s with machining

FourThousandTwo Hundred FourtY Eitht OnlY

Technical testing and analysis. Technical inspection


and certification'

Branch'
Bank A/C Details : Syndicate Bank, Chinchwad East
A/C No. 53221010005564, IFSC Code ; SYN80005322

grAilGED
nnocE ilo & DArtt ttt 1991 36
QR/Ma g/13-00-01.02. 2008
PERFECT LABORATORY SERVICES
Chemical, Mechanical, Metallurgical & Corrosion Testing
+ METALS } PLASTICS + RUBBERS
Plot No. 38 + 3/Part 19, Dl Block, MIDC, Chinchwad, Pune 41 1 019
Perfect
O +91-020-2745 8150, 2745 4716 @ trust_perfectlab@yahoo.com Certifi cate No. TC-575'l The NameToTrust

Customer: OMEGA ICEHILL Pyr. LTD.

Contact : Plot No. 37, Sector - 4, llE-pantnagar, U.S. Nagar, Uttarakhand.263 153.,
(09917944111)
W,tgt t tttitirrrte
T.C. NO. PLS_09G19_050/1 Condition ofsample Satisfactory
T.C. lssued on L2/07120L9 EnvironmentalCond. As Specified
RequisitionNo. VOITH/RG/o3/05.07.2019 Test Method Used As Applicable
Recd From OMEGA ICEHILL PVT. LTD. Received on O9/O7/2OL9
Additions to, deviations, or exclusions from test method. Nil Subcontracting Nil
SampleCode SC 09G19 OSO.1
Sample Description f .iincfr Ne x Sch 40 Duplex Stainless Steel to Stainless Steel Butt Welded Test Cout
Marked As G 101 (GOP|NATH DAS) G-01
Stamped As
General lnformation welder Name : Gopinath Das/ lD No. G-01/ process : GTAW position : 6G
Mat Spec : ASME Section ll (Part A) - SA 790/SA 790M UNS Designation 532205 - Ed.2017 + ASME section I (part A)-SA 312 / 312M
TP 304 - Ed.2017
Tested to Specification ASME - Sec. lX - Ed.2O17
sc_09G19_0s0.1 Test Method
Tensile Test i 12.07.20L91 AOS QW 462.1 (a - e) : 2017
Direction / Orientation Transverse - 1 Transverse - 2
Gauge Width mm 13.00 13.00
Thickness mm 3.55 3.56
Area sq. mm 46.1s 46.28
Ultimate Tensile Load KN 31.00 31.00
U ltimate Tensile Strength MPa 515 Min. 67L.72 (MU +/- 2.2365 rv4Pa) 669.84 (MU +/- 2.2365 MPa)
Fracture ln P.M./Ductile ln P.M./Ductile
Room Temperature (*) deg C +28 +29
Bend Test : L2.O7.2Ot9l AOS QW462.3(a):2017
Direction / Orientation Root Bend - 1 Root Bend - 2 Face Bend - 1 Face Bend - 2
width 10.00 10.00 10.10 10.00
Thickness 3.55 3.54 3.55 3.55
Former Diameter 4r 14.00 14.00 14.00 14.00
Observation No openings observed, No openings observed, No openings observed, No openings observed,
acceptable
- acceptable acceptable acceptable
Room Temperature (*) deg C +29 +2g +28

Remark

Witnessed by:
Checked Ay: (
Al,"""4
tvtr. Anand Shukre Authorised By:
\)*1
Me R. Swamy
TR/La b/05-03-0 6.07 .2019 END OF TEST CERTIFICATE u LR-TCS75119000018045F Page 1
PERFECT LABO RATORY SERVICES
Chemical, Mechanical, Metallurgical & Corrosion Testing
+ METALS + PLASTICS + RUBBERS
Plot No. 38 + 3/Part 19, D1 Block, MIDC, Chinchwad, Pune 411 019
@ +91-020-2745 8150, 2745 4716 @ trust_perfectlab@yahoo.com Certificate No.TC-5751

Customer: OMEGA ICEHILL PVt. LTD.

Contact : Plot No. 37, Sector - 4, llE-Pantnagari U.S. Nagar, Uttarakhand.263 153.,
(09917944111)
W,tgt t tttitirrte
T.C. NO. PLS_o9G19_0s0/2 Condition ofsample Satisfactory
T.C. lssued on 12107 /20L9 EnvironmentalCond. As Specified

.RequisitionNo. VOITH/RG/O3/05.07.2079 Test Method Used As Applicable

Recd From OMEGA ICEHILL PW' LTD. Received on 0910712019


Additions to, deviations, or exclusions from test methoC. Nil Subcontracting Nil

Sample Code SC_09G19_050.2


Sample Description 1.5 inch NB x Sch 40 Duplex Stainiess Steel to Stainless Steel Butt Welded Test CouF
Marked As G 101 (KR|SHNA SARKAR) G-02
Stamped As
General lnformation Welder Name : Krishna Sarkar/ lD No. G-02/ Process : LBM/ Position : 6G
Mat Spec : ASME Section ll (Part A) - SA 790/SA 79OM UNS Designation 532205 - Ed.2OU + ASME Section ll (Part A)-SA 312 / 312M
TP 304 - Ed.20L7

Tested to Specification ASME - Sec. lX - Ed.2017


Specified 09G19 Test Method

TensileTest: 12.07,20191 ADS qw 462.1 (a - e) : 2017


Transverse - 2
Width
Gauge mm - 13.00 13.00

Thickness mm - 3.47 3.48

Area sq. mm 45.11 45.24

Ultimate Tensile Load KN 29.00 30.00

Ultimate Tensile Strength MPa 515 Min. 642.87 (MU +/- 2.2365 MPa) 653.13 (MU +/- 2.2365 MPal

iracture ln PM/ Ductile ln PM/ Ductile


Room Temperature (*) +28 +28
dee C

Bend Test : t2.o7.20191 ADS qW452.3(a):2017


Root Bend- Root Bend - 2 Face Bend - 1 Face Bend - 2
Direction / Orientation 1

width 10.10 10.10 10.10 10.10

Thickness 3.47 3.47 3.45 3.47

Former Diameter 4T 14.00 14.00 14.00 14.00

Observation No openings observed, No openings observed, No openings observed, No openings observed,


accepta ble acceptable acceptable acceptable
Room Temperature (*) +28 +28 +28 +28
dee C

Remark

Witnessed by:
Checked By "N['t"t
: (Mr. Anand Shukre Authorised By:
['["ar
Mr. R. Swamy

TR/Lab/05-03-06.07.2019 PTO END OF TEST CERTIFICATE u LR-TCs7s 1 19000018047F Page