Sie sind auf Seite 1von 1

LMPT-2 Summary of FRP Flexure Enhancement

ACI 440 FRP Flexure Enhancement Results


Existing Mu Mu Mu
Thickness, Width, Total Mu
Mark Reinforcement, Required, No. of Capacity of Capacity of
mm mm Tyfo Fiber Fiber Width Capacity,
As KN-m layers Rebars, KN- Fiber, KN-
KN-m
m m
Slab 5 600 1000 1140 269 SCH-41 1 300 202.6 106 278.88
Slab 6 160 1000 1313 77 SCH-41 4 1000 41.2 123.5 81.47
Wall 2 400 1000 950 189 SCH-41 2 600 110.8 194.4 242.69
Wall 6 400 1000 950 160 SCH-41 1 300 110.8 70.3 161.81

LMPT-2 Summary of FRP Shear Enhancement


ACI 440 FRP Shear Enhancement Results
Existing Vu Beam Shear
Thickness, Width, Total Shear
Mark Reinforcement, Required, No. of Shear Capacity of
mm mm Tyfo Fiber Fiber Width Capacity,
As KN layers Capacity, Fiber,
KN
KN KN
Slab 5 400 1000 950 367 SCH-41 1 Continuous 280.4 167.47 387.19