75.71%
FCCA Score:
4) Are there consistent fabric/garment shrinkage/wash tests conducted in-house/ at outsorced washing plant and properly evaluated? x 0
Total Possible
20 Point Score 5
Comments: Percentage 25.00%
#1) Facility has no internal lab. The management affirmed that the fabric testing process is done from Taiwan which is its parent company.
#2) The laboratory is setup overseas in Taiwan which is the parent company of Min Kuan Textile Co., Ltd. However, it is not certified by other major U.S. company.
#3) Facility has color test done from overseas based on customers requirements. Results are communicated to other departments properly. The test reports are sent from parent copany with
color band and fabric and are kept for reference.
#4) There is no In-house shrinkage/wash tests conducted for every style. Steam panels/blankets wash test are carefully evaluated and approved prior to cutting.
10 5 3 0
1) Is the sample room fully equipped to produce samples that are representative of factory's specific product type? x 5
2)Is there a skilled sample room technician available and capable of modification of patterns when required and responsible for x 10
handover to production floor with record available? [Critical]
3)Are CAD system and plotter used for grading, consumption and marker ? x 0
6) Are sample room fabric, trims & accessories well organized in sample room? Is house keeping acceptable? x 10
11) Does cutting has its own approved sample for reference? x 5
Total Possible
110 Point Score 80
Percentage 72.73%
Comments:
#1) WIP is within 2 days and less then 3 days to produce the 1st bulk production.
#2) During onsite audit facility, has relaxed some fabrics, However, there was no relaxation rack and equipments, no procedure to show fabrics had relaxed base on fabric content and type,
and no record of relaxation.
#3) Shade variances system is used. All layer are separated by lots and color during spreading.
#4) Manual spreading techniques was used, however spreaders were well trained and acceptable, Spreading height not more than 4 inches and length between 3 to 8 meters.
#5) Well controlled in alignment, matching by string / light beam and cut in appropriate height and length, plus proper numbering, template for manual trimming, bundling, Spreading random
inspection is done and recorded.
#6) Storage is sufficiently available with racking and excess cutting. Cut parts are properly stored/covered.
#7) Cut pieces are 100% inspected by QC cutting. Numbering processes is done with appropriate tools and good record keeping.
#8) Hand iron, label fusing and piece continuous roller pressing are available with calibration record. Fusing qualities is acceptable.
#9) Bulk cut goods are properly stored in the rack and covered with thick poly bag.
Light and dark colors are well segregated. Light bundle strings are used for light color.
#10) Lighting is 108.5 FC
4) Are in-house pre-production meetings and Pilot runs conducted for each style, prior to bulk production, and meetings attended by x 10
factory personnel?
5) Are approved samples available on every line for review, and sample comments translated into local x 10
6) Are production lines well balanced and set up in systematic process, without bottlenecks? x 10
7) Is there a proper system to record broken/damaged needles, scissors, thread cuttters, tag gun needles & hand x 10
stitching needles etc. at both sample room and production floor? [Critical]
8) Is production floor well organized and clean, and isles clear, free of clutter ? x 10
9) Are adequate systems used to isolate defective and / or repaired products ? [Critical] x 10
10) Are there on site mechanics who regularly maintain all machines and maintenance records well kept? x 10
11) Is there proper maintenance department equipped with adequate tools and necessary equipment? x 10
12) Are sharp objects such as trimmers and scissors effectively tracked e.g. that they are permanently attached to the x 10
machines and there is regular monitoring so missing of 'attached' sharp objects will not go unnoticed? [Critical]
13) Is lighting adequate(100FC and above)? x 3
Total Possible
130 Point Score 101
Percentage 77.69%
Comments:
#1) There was no onsite IE staff and technical team to handle the time study and line balancing. Only the production manager is responsible to do the machine lay out and basic line
balancing. However, there was no any records to show IE job is done properly.
#2) There was no production planning department. Production manager responsible for production planning uses self designed spreadsheet. Some necessary adjustments are made to meet
delivery schedule.
#3) There is a training procedure for new sewing operator and quality controller. However, no training room was available. New operators are assigned to respective line leaders for on job
training in the production floor with record of training maintained.
#4) Pre-production meeting with appropriate department head like warehouse supervisor, cutting supervisor, sewing supervisor, sample room in charge, Ironing supervisor, finishing
supervisor and including mechanic supervisor are conducted for every new style with records.
#5) Both approved sample and trim card with signature and comments in local language are displayed on each sewing line.
#6) Sewing line and production process are well balanced. There is no obvious bottlenecks in each working process, the input, and output quantity from each department are recorded.
#7) Needle control policy/system is setup and communicated to relevant employees. Based from the interview, the needle exchanging system is effectively controlled. The broken needle
controller know the procedure change needle very well. Based from random check on 5 single needle sewing machines, there are no any needle fragment found.
#8) Production floor and aisles are clean and well organized.
#9) There is an effective quality control system in use. Defective garments are placed separately. Records are properly kept immediately and repairs are made within the hour.
1) Does factory have inspection system at inline and end line? Does factory measure complete garment? [Critical] x 10
2) If garments, or garment parts, are constructed at subcontracted facilities, or if embroidery, printing, or laundry functions are handled x x
at off-premises facilities, are returned garments and/or panels properly inspected before they are released back to bulk
production work flow again?
3) Does QA/QC department have an independent reporting structure? Are all QA/ QCs trained regularly? [Critical] x 10
4) Factory has a complete set of their buyer's technical manual hard copy and knows how to obtain updated information. x 10
5) Does factory conduct inspection on daily completed garments after sewing line using buyer AQL or tighter and does factory take x 5
on failures?
6) Is lighting adequate (100 FC and above)? x 10
7) How are alteration/defective garments handled in all section? x 10
8) Does factory has sufficient well equipped inspection room? x 10
Total Possible
70 Point Score 65
Percentage 92.86%
Comments:
#1) Factory has inline inspection process and end line inspection with adequate QC at each sewing lines based on out put and recording system, completed garments are measured using
AQL 1.5 from total production covering color & size daily all through the day and records are written by pencil and properly kept.
#2) There is no garment, or garment part constructed at subcontracted facilities
#3) QC/QA had its own reporting structure to report to QA supervisor and QA supervisor report to factory manager. All QC/QA are well trained with records kept.
#4) Factory has setup its own quality manuals in local language which is updated with its buyer’s standard and fully understands the requirements and existing factories has manual
translated to local language.
#5) Factory conducts inspection hourly based on AQL 2.5. Factory rechecks failed lots before sending to next process. Records writing need minor improvement.
#6) Lighting level at inspection table is 101.6 FC.
#7) Found defective garments are segregated properly by red plastic stands. Records are kept and root cause of defect is investigated and analyzed with corrective action.
5) Are pressed garments handled properly prior to packing? How is WIP handled in the section? x 10
Total Possible
50 Point Score 43
Percentage 86.00%
Comments:
#1) Pressing standard was not setup at each pressing table, but pressing supervisors are available. Pressing operators well understood the standard.
#2) Appropriate pressing equipments are available since on the pressing tables are setup with the pattern to control the measurement during pressing process. Pressing equipment is found
in good condition with no leakage & rust. The covering cloth is correct and clean, steam is completely dry, vacuum is strong enough, calibration of the boiler and iron machine maintenance
card available and updated. House keeping of pressing area is acceptable.
#3) Measurement inspection using AQL 2.5 is done after pressing with records well maintained.
#4) Pressing is well ventilated and lighting level was above 80 FC.
#5) Sufficient hanging racks/shelf racks for pressed garments. Pressed garments are hanged in appropriate height.
2)Is there a 100% final checking after finishing and is there a random audit done after finishing? Is there a 100% x 10
measurement for key points and audit done after finishing? [Critical]
3) Is there an effective stain management and repair operation on site ? x 10
4) Is there an organized and efficient work flow in the finishing area? How are the WIP levels? x 10
5) Is lighting adequate (100 FC for inspection and 60-80 for other areas)? x 5
6) Does factory conduct final audit based on same (or tighter) AQL of buyer? [Critical] x 10
9) Is the storage space for packed goods enough as per the factory capacity? x 10
10)Is there a procedure in place to remove uncut thread and loose threads and foreign materials? x 5
Total Possible
100 Point Score 90
Percentage 90.00%
AUDIT OF Twenty (20) PIECES FINISHED GARMENTS.
Pass AQL 2.5, Pass if 1 Major found, fail for 2
No score if pass, need to insert comment for fail
Comments:
#1) Specification/samples are displayed with approval signature at finishing/packing section for references.
#2) 100% final inspection after finishing done for critical measurement. There is also a random checking on finished carton.
#3) There is appropriate stain cleaning room at onsite facility using benzene. The cleaning station is well equipped with a compressed air gun. PPE and exhaust fan are provided. Repair of
work station is well organized. MSDS is available with records maintained for corrected pieces and reject pieces.
#4) Well organized and efficient balance workflow setup at finishing section.
#5) Lighting level at inspection area was 117.6 FC and 80 FC at working table.
#6) Facility conducted final audit/inspection based on AQL 2.5 as sampling standard after packing at least 80%. Records were available and failed goods are re-audited after correction.
#7) Found defects from finishing operation and sewing/fabric defect (less than 1%) are segregated properly. Defective garments are sent to respective area for correction with record being
kept.
#8) Finishing area is in good housekeeping and ventilation. Tables are found clean without any rough edges.
Total Possible
0 Point Score 0
Percentage 0.00%
Random check finished panels. Quality acceptable or unacceptable
Comments:
Embroidery process is outsourcing.
Total Possible
30 Point Score 0
0 Percentage 0.00%
Comments:
No garment washing onsite.
6) Does factory maintain lead test for printing items? [Critical] ( For childrenswear for US dept 26, 24, 33 and Asda/George) x x
Total Possible
30 Point Score 20
Percentage 66.67%
Comments:
#1) Metal detector placed in an airport system. There is proper layout/setup to avoid/minimize the possibility of goods by-passing the metal detection process. Metal detector is
calibrated regularly 3 times per day with proper records. Locked rejected bin to keep the contaminated products was also setup. 1-in/1-out needle control policy was setup and
effectively implemented.
#2) Facility has pull test equipment available. SOP for pull strength testing is available.
found proper records and only assigned person from quality can perform test. Calibration was available.
#3) Factory does not use any lockstitch for button attached.
* CAP to be generated for any score falls in either 0 or 3 and critical/ safety area.
* New factory which scores zero on CRITICAL questions (which are in BOLD) will be rated 'Unacceptable' until corrections are completed
and validated by WM associates / 3rd party auditors. Dark check boxes are no scoring
* Existing factory must correct within a specific time period or will be disqualified for new order placement.