Sie sind auf Seite 1von 54

Issue Number (1/4)

TECHNICAL INFORMATION
FROM
MARITIME SOLUTION GROUP

Subject : Information on Inmarsat-C JUE-87’s new software release

Equipment : JUE-87/JUE-85 with EME type NAF-253GM

Issue Date : April 28, 2017

Issue Number : SC-0003-17

Shintaro Inoue
Assistant General Manager & Group Leader
Maritime Solution Group
Marine Solution Engineering Department
Issue Number (2/4)

    Priority [ ] A: Carry out immediately


     [×] B: Carry out at periodical inspection
[×] C: Carry out upon client’s request
[ ] D: Information and news

1㸬Subject
Information on Inmarsat-C JUE-87/JUE-85 with EME type NAF-253GM’s new software release
a) JUE-87 software
䐟ACSE (NAF-253GM) maintenance version Ver.1.13
䐠DTE (NTF-318) maintenance version Ver.1.13
䐡Recovery DTE (NTF-318) maintenance version Ver.1.13
b) JUE-85 with NAF-253GM software
ACSE (NAF-253GM) maintenance version Ver.10.55

2. Objective Equipment
a) JUE-87 EME (NAF-253GM) / IME (NTF-318)
b) JUE-85 EME (NAF-253GM)

3. Phenomenon and countermeasures


<Phenomenon>
a) JUE-87 ACSE (NAF-253GM) maintenance version Ver.1.12 and JUE-85 ACSE (NAF-253GM)
maintenance version Ver.10.54 have the following phenomenon:
- If starting up the function of SSAS real transmission, SSAS test transmission, or the
scheduled transmission, JUE-87 may repeat the same transmission two or three times.
b) JUE-87 IME (NTF-318)’s DTE maintenance version Ver.1.12 has the following phenomenon:
- If “Network type” of the scheduled transmission No.1 to No.5 is setup as “E-mail”, the all
EME’s setting data cannot be carried out Export/Import function correctly.

<Countermeasures>
a) Regarding JUE-87 ACSE (NAF-253GM) maintenance version Ver.1.13 and JUE-85 ACSE
(NAF-253GM), improved that SSAS and the scheduled multiple transmission are not carried out.
b) Regarding JUE-87 IME (NTF-318)’s DTE maintenance version Ver.1.13, improved that the all
EME’s setting data can be carried out Export/Import function correctly.

<New Software Version Combination>


a) JUE-87
EME (NAF-253GM) Software IME (NTF-318) Software
New ACSE MODEM IME Maintenance New DTE
JUE-87 Maintenance Version Software Version Maintenance
Version Version*
1.13 11.0 1.02 1.13

*: Recovery DTE Software is Ver.1.13 and ready as another file.


Issue Number (3/4)
b) JUE-85 with NAF-253GM

EME (NAF-253GM) IME DTE Software PC tool


Software (NTF-841GM)
Software
New ACSE MODEM IME NDZ-127C1 NDZ-227 winIST
Maintenance Software Maintenance Maintenance Maintenance Software
Version Version Version Version Version Version
JUE-85 10.55 11.0 3.01 12.50 2.61 10.64

<Note on Upgrading New Software>


a) In case of JUE-87
- This new function correctly works with the above software version combination.
- The software upgrade refers to the attachment3 “JUE-87 Software Update Procedure”.
The new software can be downloaded from the Marine Service Department WEB site.

File Name: “JUE-87Software20170424.zip”

The above file is included in the following software:


࣭”Readme.txt”
࣭”update_desc.txt”  (New for DTE Recovery Software)
࣭”JUE-87㹚ACS㹚JUE87_ACS_0113.jrc”  (New)
࣭”JUE-87㹚DTE㹚JUE87_DTE_0113.BIN” (New)
࣭”JUE-87㹚DTE㹚JUE87_DTE_PLAIN_0113.BIN” (New for DTE Recovery)
࣭” ¥JUE-87¥IME¥JUE87_IME_0102.jrc”   (Current)

The above software should be copied into root directory of your USB memory as follows:

On the USB memory


࣭”㹚update_desc.txt”
࣭” 㹚JUE-87㹚ACS㹚JUE87_ACS_0113.jrc”
࣭” 㹚UE-87㹚DTE㹚JUE87_DTE_0113.BIN”
࣭” 㹚JUE-87㹚DTE㹚JUE87_DTE_PLAIN_0113.BIN”
࣭” 㹚JUE-87㹚IME㹚JUE87_IME_0102.jrc”

- Because Export/Import function is improved, please upgrade IME (NTF-318)’s DTE


maintenance version Ver.1.13 before carrying out Export function this time.
- Confirm a software version in an alarm pack by all means, because there may be the
mismatch of the software version by the delivery date of EME and IME which are
equipped from now. In case of the mismatch of the software version combination, upgrade
to the new software. (See the attachment3.)
- If the new DTE software upgrading fails and IME does not start correctly, update it using
the recovery DTE software. (See the attachment5.)
Issue Number (4/4)

b) In case of JUE-85 with NAF-253GM


- JUE-85’s EME is the current type “NAF-253GM” and the old type “NAF-741GM”. Because
this objective EME is the current type “NAF-253GM”, please be careful.
- This new function correctly works with the above software version combination.
- The software upgrading refers to the attachment4 “JUE-85 with NAF-253GM’s ACSE
Software Update Procedure”. The new software can be downloaded from the Marine
Service Department WEB site.

File Name: “JUE85-A_ACS1055.zip”

This above file is included in the following software:


䞉”JUE85-A_ACS1055.jrc” (New)

<Working Order>
If this working is according to this technical information, please use Z order.

4. Attached document
a) Inmarsat-C JUE-87 Software Version List (Attachment1)
b) Inmarsat-C JUE-85 Software Version List (for NAF-253GM) (Attachment2)
c) JUE-87 Software Update Procedure (Attachment3)
d) JUE-85 with NAF-253GM’s ACSE Software Update Procedure (Attachment4)
e) JUE-87 IME (NTF-318)’s DTE Software Recovery Update Procedure (Attachment5)

5. Related Service-news and/or Technical Information


a) SC-0001-16: “Information on Inmarsat-C JUE-87’s new software release” (June 27, 2016)
b) SC-0002-16: “Information on Inmarsat/mini-C JUE-85/95 with NAF-253’s EME series new
software release” (June 27, 2016)
Attachment1

Inmarsat-C JUE-87 Software Version List


April 24, 2017
Maritime Solution Group
Marine Engineering Department
ACSE Software (NAF-253GM)
Maintenance
No. Software Version Modification
Number
SSAS real, SSAS test and the scheduled multiple transmission function are improved.
4 1.00 1.13
(Software combination : ACSE 1.13/MODEM 11.0/IME 1.02/DTE 1.13)

䐟LRIT's relation function addition(DNID selection screen's authentication function, 24hour


setup of LRIT transmission interval), 䐠MFD's connection function addition(external output of
EGC message, LRIT ON/OFF setup, 24hour setup of LRIT transmission interval), 䐡Judgment
3 1.00 1.12 function of the model compatibility between EME an IME, 䐢GX/FBB RMS's alarm information
acquisition function addition, 䐣Improvement of Internal GPS(CCA-600)'s date error, 䐤Ohters
(Software combination : ACSE 1.12/MODEM 11.0/IME 1.02/DTE 1.12)

Support of optional apparatus (RDB/SB/DMC) for common use type (Partil Release)
2 1.00 1.05
(Software combination : ACSE 1.05/MODEM 11.0/IME 1.02/DTE 1.05)
Initial release
1 1.00 1.02
(Software combination : ACSE 1.02/MODEM 11.0/IME 1.01/DTE 1.01)

MODEM Software (NAF-253GM)


No. Software Version Modification
1 11.00 Initial release

IME Software (NTF-318)


Maintenance
No. Software Version Modification
Number
2 1.00 1.02 Support of optional apparatus (RDB/SB/DMC) for common use type
1 1.00 1.01 Initial release

DTE Software (NTF-318)


Maintenance
No. Software Version Modification
Number
Export/Import function of all EME's setting data is improved. (If “Network type” of the
4 1.00 1.13 scheduled transmission No.1 to No.5 is setup as “E-mail”, all EME's setting data cannot be
carried out Export/Import function correctly.)
䐟LRIT's relation function addition(DNID selection screen's authentication function, 24hour
setup of LRIT transmission interval), 䐠MFD's connection function addition(external output of
EGC message, LRIT ON/OFF setup, 24hour setup of LRIT transmission interval), 䐡Judgment
3 1.00 1.12
function of the model compatibility between EME and IME, 䐢GX/FBB RMS's alarm
information acquisition function addition, 䐣Improvement of Internal GPS(CCA-600)'s date
error, 䐤Ohters
2 1.00 1.05 Support of optional apparatus (RDB/SB/DMC) for common use type (Partial Release)
1 1.00 1.01 Initial release

DTE Recovery Software (NTF-318) 䚷(This software is used for recovery when NTF-318 cannot startup.)
Maintenance
No. Software Version Modification
Number
4 1.00 1.13 DTE recovery software for DTE software Ver1.13
3 1.00 1.12 DTE recovery software for DTE software Ver1.12
2 1.00 1.05 DTE recovery software for DTE software Ver1.05 (Not Release)
1 1.00 1.01 DTE recovery software for DTE software Ver1.01
Attachment2

Inmarsat-C JUE-85 Software Version List (for NAF-253GM)


April 24, 2017
Maritime Solution Group
Marine Solution Engineering Department
ACSE Software (NAF-253GM)
Maintenance
No. Software Version Modification
Number

SSAS real, SSAS test and the scheduled multiple transmission function are
improved.
3 10.50 10.55 (Software combination : ACSE 10.55/MODEM 11.0/IME 3.01/DTE (NDZ-227) 2.50 or
2.61/DTE(NDZ-127C1) 12.50)
䐟LRIT's relation function addition(DNID selection screen's authentication
function, 24hour setup of LRIT transmission interval), 䐠Improvement of Internal
GPS(CCA-600)'s date error, 䐡Restriction function of 15minutes transmitting
2 10.50 10.54 interval for Position Reporting (DR/EDR)
(Software combination : ACSE 10.54/MODEM 11.0/IME 3.01/DTE (NDZ-227) 2.50 or
2.61/DTE(NDZ-127C1) 12.50)

1 10.50 10.50 Initial release

MODEM Software (NAF-253GM)


No. Software Version Modification
1 11.00 Initial release

IME Software (NTF-781GM)


Maintenance
No. Software Version Modification
Number
1 3.00 3.01 IME software is the same as the current JUE-85 IME.

DTE (NDZ-227) Software


Maintenance
No. Software Version Modification
Number
䐟LRIT's relation function addition(DNID selection screen's authentication
2 2.50 2.61 function, 24hour setup of LRIT transmission interval), 䐠JUE-87 Remote DTE
support
1 2.50 2.50 DTE software is the same as the current NDZ-227.

DTE (NDZ-127C1) Software


Maintenance
No. Software Version Modification
Number
1 12.50 12.50 DTE software is the same as the current NDZ-127C1
Attachment3

JUE-87 Software Update Procedure

April 24, 2017


Maritime Solution Group
Marine Solution Engineering Department

1. Outline
This manual explains update procedure of Inmarsat-C JUE-87 software.

࣭DTE software* (Maintenance Number: 01.13) (New)


࣭IME software* (Maintenance Number: 01.02) (Current)
࣭ACSE(EME) software (Maintenance Number: 01.13) (New)

*: There are DTE software and IME software in IME.

2. Preparation

2-1 Upgrade equipment


(1) Prepare below parts
x EME㸸NAF-253GM
x IME㸸NTF-318
x Keyboard㸸NDF-369
x EXT PSU㸸NBD-904
x Coaxial cable(Between IME and EME)㸸CFQ-5922A

(2) Connect each equipment, as shown in following.

㻱㻹㻱
㻔㻺㻭㻲㻙㻞㻡㻟㻳㻹㻕

㻯㼛㼍㼤㼕㼍㼘㻌㻯㼍㼎㼘㼑
㻔㻯㻲㻽㻙㻡㻥㻞㻞㻭㻕
㻱㻹㻱

㻵㻹㻱 㻰㻯㻌㻼㻻㼃㻱㻾
㻱㼄㼀㻌㻼㻿㼁
㻔㻺㼀㻲㻙㻟㻝㻤㻕 㻔㻺㻮㻰㻙㻥㻜㻠㻕
㻷㼑㼥㼎㼛㼍㼞㼐

㻷㼑㼥㼎㼛㼍㼞㼐
㻔㻺㻰㻲㻙㻟㻢㻥㻕

1
Attachment3

2-2 Software file

(1) Prepare below parts


x USB Flash memory
(2) Prepare below files on your USB Flash memory.
Put the files in each specified directory.
x DTE software 㸸 JUE87_DTE_0113.BIN
(Directory 㸸 “\JUE-87\DTE\”)
x IME software 㸸 JUE87_IME_0102.jrc
(Directory 㸸 “\JUE-87\IME\”)
x ACSE software 㸸 JUE87_ACS_0113.jrc
(Directory 㸸 “\JUE-87\ACS\”)

3. Procedure

(1) DTE software upgrading

(2) Export

(3) IME software upgrading

(4) ACSE (EME) software upgrading

(5) FROM/SRAM initialize

(6) Import

(7) Softwaer version confirmation

2
Attachment3

3-1 DTE software upgrading


It takes about 5 minutes for a software upgrading of DTE.

(1) Turn on the IME.


(2) The boot screen will be displayed about 5 seconds after turn on the IME.
Press the ‘N’+ ‘D’+ ‘Z’ keys during “now loading” in the boot screen.
The maintenance mode will be initiated.

NOTE

Please wait about 30 seconds after initiating to maintenance mode


until communication between EME-IME starts.

Fig.3-1a Maintenance Menu screen

3
Attachment3

(3) Press up key or down key, select [4. Software Upgrade] and press ‘Enter’ key on Maintenance
Menu screen. Software Upgrade menu screen (refer to Fig.3-1b) will be displayed.

Fig.3-1b Software Upgrade menu screen

(4) Press up key or down key, select [1. Target] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-1b).

(5) Press up key or down key, select “DTE Main” and press ‘Enter’ key.

7DUJHW'7(0DLQ

(6) Confirm Software Version in [3. Current Maintenance Info.].


When Version is "01.13", the upgrade of DTE software is unnecessary.

4
Attachment3

(7) Press up key or down key, select [2. Input Port] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-1b).

(8) Press up key or down key, select “USB Memory” and press ‘Enter’ key.

,QSXW3RUW86%0HPRU\

(9) Insert the USB Flash memory which includes DTE Main software and auxiliary file for recovery
to the DTE.

NOTE

- USB symbol will be displayed beside screen title when USB Flash memory is inserted.
- To remove the USB Flash memory safety, press ‘Shift + R’ keys.

(10) Press up key or down key, select [4. File Selection] and press ‘Enter’ key on Software Upgrade
menu screen (refer to Fig.3-1b).

(11) Press up key or down key, select DTE Main software and press ‘Enter’ key.

)LOH6HOHFWLRQ-8(B'7(B%,1

(12) Upgrade software in accordance with following flow chart.

5
Attachment3

Select [Cancel]

Press ‘*’ key





 Select [OK]




Upgrading will be started automatically after reading data


from the USB Flash memory is finished.

Upgrade Failure

Upgrade Success

The IME will be rebooted automatically


and upgrade will be finished.

6
Attachment3

3-2 Export
Save the each parameter into a file or print out before the ACSE/IME updating, because the updating
clears all the parameters of ACSE/IME.

The parameters can be/ cannot be restored after saved are:


x Can be restored
Setting of peripheral function (automatic print, printer connection, port setting, etc.)
Address Book of TELEX/Facsimile/Data (PSDN)
NCS information, LES name, Schedule transmission setting, SSAS setting,
Land ID registration for polling, and EGC reception selecting
x Cannot be restored
Ocean Region selection, received message, EGC message, alarm pack, PV test result,
SSAS password, and schedule program, etc.

NOTE

Please wait about 30 seconds after initiating to maintenance mode


until communication between EME-IME starts.

(1) Turn on the IME.


(2) The boot screen will be displayed about 5 seconds after turn on the IME.
Press the ‘N’+ ‘D’ + ‘Z’ keys during “now loading” in the boot screen.
The maintenance mode will be initiated.
(3) Press up key or down key, select [5. Inmarsat-C Setting & Checking] and press ‘Enter’ key on
Maintenance Menu screen. Continuously, select [Export/Import] and press ‘Enter’ key.
Export/Import screen (refer to Fig.3-2b) will be displayed.

7
Attachment3

Fig.3-2a Maintenance Menu screen

(4) Press [Export] in Fig.3-2b (Fig.3-2c is displayed).

Fig.3-2b Export/Import screen

8
Attachment3

(5) Enter the name of Export file and Press [F1] (Fig.3-2d is displayed).
NOTE㸸Export file name is "***.IN2".

Fig.3-2c [Export] dialog box

(6) Press [OK] in Fig.3-2d. Then the Export is started and Fig.3-2e is displayed.

9
Attachment3

Fig.3-2d Export confirmation dialog box

10
Attachment3

Fig.3-2e Export progressing status confirmation dialog box

(7) Fig.3-2f is displayed when the Export is completed. Press [F10].

Fig.3-2f Export completion dialog box

11
Attachment3

3-3 IME software upgrading


It takes about 10 minutes for a software upgrading of IME.

(1) Turn on the IME.


(2) The boot screen will be displayed about 5 seconds after turn on the IME.
Press the ‘N’+ ‘D’+ ‘Z’ keys during “now loading” in the boot screen.
The maintenance mode will be initiated.

NOTE

Please wait about 30 seconds after initiating to maintenance mode


until communication between EME-IME starts.

Fig.3-3a Maintenance Menu screen

12
Attachment3

(3) Press up key or down key, select [4. Software Upgrade] and press ‘Enter’ key on Maintenance
Menu screen. Software Upgrade menu screen (refer to Fig.3-3b) will be displayed.

Fig.3-3b Software Upgrade screen

(4) Press up key or down key, select [1. Target] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-3b).

(5) Press up key or down key, select “IME” and press ‘Enter’ key.

7DUJHW,0(

(6) Confirm Software Version in [3. Current Maintenance Info.].


When Version is "01.02", the upgrade of IME software is unnecessary.

NOTE

When target is selected, [Current Software Version] may be displayed as ‘UNKNOWN’.


(Current software was unavailable, etc)
Even in this case, since Upgrade can be carried out, please advance a procedure as it is.

13
Attachment3

(7) Press up key or down key, select [2. Input Port] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-3b).

(8) Press up key or down key, select “USB Memory” and press ‘Enter’ key.

,QSXW3RUW86%0HPRU\

(9) Insert the USB Flash memory which includes IME software.

NOTE

- USB symbol will be displayed beside screen title when USB Flash memory is inserted.
- To remove the USB Flash memory safety, press ‘Shift + R’ keys.

(10) Press up key or down key, select [4. File Selection] and press ‘Enter’ key on Software Upgrade
menu screen (refer to Fig.3-3b).

(11) Press up key or down key, select software and press ‘Enter’ key.

)LOH6HOHFWLRQ-8(B,0(B%,1

(12) Upgrade software in accordance with following flow chart.

NOTE

When an upgrade confirmation screen isn't displayed even if '*' key is pressed after a procedure
(1)-(11) is put into effect, please press Ctrl+I key.
After confirming that "- Press '*' key" is shown to< Functions>, please press '*' key once again.

14
Attachment3

Select [Cancel]

Press ‘*’ key




 Select [OK]





Upgrading will be started automatically after reading


data from the USB Flash memory is finished.

Upgrade Failure

Upgrade Success

The IME will be rebooted automatically


and upgrade will be finished.

15
Attachment3

3-4 ACSE (EME) software upgrading


It takes about 20 minutes for a software upgrading of ACSE.

NOTE
Be careful about the following thing about upgrade work.
㺃When a power supply of a terminal became off while doing an upgrade, there is a possibility
that JUE-87 doesn't start. The upgrade is possible even in that case. Try an upgrade once again.

(1) Turn on the IME.


(2) The boot screen will be displayed about 5 seconds after turn on the IME.
Press the ‘N’+ ‘D’+ ‘Z’ keys during “now loading” in the boot screen.
The maintenance mode will be initiated.

NOTE

Please wait about 30 seconds after initiating to maintenance mode


until communication between EME-IME starts.

Fig.3-4a Maintenance Menu screen

16
Attachment3

(3) Press up key or down key, select [4. Software Upgrade] and press ‘Enter’ key on Maintenance
Menu screen. Software Upgrade menu screen (refer to Fig.3-4b) will be displayed.

Fig.3-4b Software Upgrade screen

(4) Press up key or down key, select [1. Target] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-4b).

(5) Press up key or down key, select “ACS” and press ‘Enter’ key.

7DUJHW$&6

(6) Confirm Software Version in [3. Current Maintenance Info.].


When Version is "01.13", the upgrade of ACSE software is unnecessary.

NOTE

UNKNOWN is sometimes shown to [Software Version]. (When software isn't written in or


the present software is abnormal.)
A software upgrade is possible even in that case. Advance a procedure.

17
Attachment3

(7) Press up key or down key, select [2. Input Port] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-4b).

(8) Press up key or down key, select “USB Memory” and press ‘Enter’ key.

,QSXW3RUW86%0HPRU\

(9) Insert the USB Flash memory which includes ACS software.

NOTE

- USB symbol will be displayed beside screen title when USB Flash memory is inserted.
- To remove the USB Flash memory safety, press ‘Shift + R’ keys.

(10) Press up key or down key, select [4. File Selection] and press ‘Enter’ key on Software Upgrade
menu screen (refer to Fig.3-4b).

(11) Press up key or down key, select software and press ‘Enter’ key.

)LOH6HOHFWLRQ-8(B$&6BMUF

(12) Upgrade software in accordance with following flow chart.

NOTE

When an upgrade confirmation screen isn't displayed even if '*' key is pressed after a procedure
(1)-(11) is put into effect, please press Ctrl+I key.
After confirming that "- Press '*' key" is shown to< Functions>, please press '*' key once again.

18
Attachment3

Select [Cancel]

Press ‘*’ key





 Select [OK]




Upgrading will be started automatically after reading


data from the USB Flash memory is finished.

Upgrade Failure

Upgrade Success

The IME will be rebooted automatically


and upgrade will be finished.

19
Attachment3

3-5 FROM/SRAM Initialization

NOTE

Initialization of FROM/SRAM clears configuration information, such as a SSAS


Transmission, and important log, such as Alarm history, call log, etc.
Please do not initialize recklessly.

(1) Turn on the IME.


(2) The boot screen will be displayed about 5 seconds after turn on the IME.
Press the ‘N’+ ‘D’+ ‘Z’ keys during “now loading” in the boot screen.
The maintenance mode will be initiated.

NOTE

Please wait about 30 seconds after initiating to maintenance mode


until communication between EME-IME starts.

(3) Press up key or down key, select [5. Inmarsat-C Setting & Checking] and press ‘Enter’ key on
Maintenance Menu screen. Continuously, select [Data Initialize] and press ‘Enter’ key.
Inmarsat-C Checking screen (refer to Fig.3-5b) will be displayed.

20
Attachment3

Fig.3-5a Maintenance Menu screen

(4) Press up key or down key, select [FROM Clear] and press ‘Enter’ key.

Fig.3-5b Inmarsat-C Data Initialize screen

(5) Select [OK] and press ‘Enter’ key then FROM Clear will be started.

21
Attachment3

Fig.3-5c FROM Clear confirmation dialog box

(6) Fig.3-5d is displayed when the FROM Clear is completed. Press [F10].

Fig.3-5d FROM Clear completion dialog box

(7) Carry out SRAM Clear like a procedure (4)-(6).

(8) Restart Inmarsat-C terminal in a power button of IME.

22
Attachment3

3-6 Import
(1) Turn on the IME.
(2) The boot screen will be displayed about 5 seconds after turn on the IME.
Press the ‘N’+ ‘D’+ ‘Z’ keys during “now loading” in the boot screen.
The maintenance mode will be initiated.

NOTE

Please wait about 30 seconds after initiating to maintenance mode


until communication between EME-IME starts.

(3) Press up key or down key, select [5. Inmarsat-C Setting & Checking] and press ‘Enter’ key on
Maintenance Menu screen. Continuously, select [Export/Import] and press ‘Enter’ key.
Export/Import screen (refer to Fig.3-6b) will be displayed.

Fig.3-6a Maintenance Menu screen

23
Attachment3

(4) Press [Import] in Fig.3-6b (Fig.3-6c is displayed).

Fig.3-6b Export/Import screen

(5) Press up key or down key, select Import file or enter the name of Import file.
Then press ‘Enter’ key. (Fig.3-6d is displayed).

Fig.3-6c [Import file] dialog box

24
Attachment3

(6) Select [OK] and press ‘Enter’ key in Fig.3-6d. Then the Import is started and Fig.3-6e is displayed.

Fig.3-6d Import confirmation dialog box

Fig.3-6e Import progressing status confirmation dialog box

25
Attachment3

(7) Fig.3-6f is displayed when the Export is completed. Press ‘F10’ key.

Fig.3-6f Import completion dialog box

(8) Restart Inmarsat-C terminal in a power button of IME.

26
Attachment3

3-7 Software Version confirmation


(1) Turn on the IME.
(2) Confirm that Software version of the boot screen is indicated like following Fig.3-7a.

Fig.3-7a DTE boot screen (Standard model)

(3) Press ‘Alt + A’ keys from DTE main menu (Fig.3-7b will be displayed).

Fig.3-7b Main screen (Diagnostics menu is displayed)

27
Attachment3

(4) Press up key or down key, select [Alarm history] and press ‘Enter’ key on Diagnostics Menu
(Fig.3-7c will be displayed).

Fig.3-7c Main screen (Alarm history window is displayed)

(5) Confirm the displayed model and version.


Model : JUE-87
ACSE : 01.13
IME : 01.02
DTE : 01.13

28
Attachment4

JUE-85 with NAF-253GM’s


ACSE Software Update Procedure

April 24, 2017


Maritime Solution Group
Marine Solution Engineering Department

1. Outline
This manual explains upgrade procedure of Inmarsat-C JUE-85 with NAF-253GM
(“JUE-85-A”) ACSE(EME) software. (Maintenance Number: 10.55)

2. Preparation
1) Prepare below parts
x PC
x Straight serial cable

2) Prepare below file on your PC


x JUE-85 ACSE(EME) software 㸸 JUE85-A_ACS1055.jrc
x PC tool㸸winIST_CN149(JUE8595_winIST_CN149_1064.exe)

3. Procedure

3-1 Outlines

1) ACSE(EME) software upgrading preparation

2) Export

3) Maintenance Number confirmation before upgrading


When Maintenance Number is "10.55", the upgrade of ACSE software is unnecessary.

4) ACSE(EME) software upgrading


It takes about 20 minutes for a software upgrading of ACSE.

5) Maintenance Number confirmation after upgrading

6) SRAM/FROM Clear

7) Import

-1-
Attachment4

NOTE
Please note the following matters for upgrading.
1. JUE-85 might not shift to the update mode due to the compatibility of PC and the USB
serial conversion cable. In this case, please try the work about ten times repeatedly.
The mode might shift normally when several times tried.

2. JUE-85 might not start normally after turning off the power supply of the terminal during
upgrading. Even in this case, upgrading is also possible.
Try upgrading again.

3-2 Details

1) ACSE(EME) software upgrading preparation


Connect each equipment, as shown in Fig.1. Then turn ON the power supply of IME.

JUE-85-A/95SA-A/95VM-A/95LT-A
Straight serial cable

EME
COM1
X3 MAIN DTE (RS-232C)
IME PC

Fig.1 Each equipment connection

ͤ Change the DIP switch of IME PANEL to a model of a target. (refer to attachment) And
carry out software upgrade.

-2-
Attachment4

2) Export
Save the each parameter into a file or print out before the ACSE/IME updating, because the
updating clears all the parameters of ACSE/IME.

The parameters can be/ cannot be restored after saved are:


x Can be restored
Setting of peripheral function (automatic print, printer connection, port setting, etc.),
Address Book of TELEX/Facsimile/Data (PSDN), NCS information, LES name,
Schedule transmission setting, SSAS setting Land ID registration for polling, and EGC
reception selecting
x Cannot be restored
Ocean Region selection, received message, EGC message, alarm pack, PV test result,
SSAS password, and schedule program, etc.

NOTE

1. About the data of received message, EGC message, and alarm pack, save them to a file or print
out, because upgrading software clears all of them away.

2. When the Schedule program (Data report program using DNID) is registered into main unit, the
customer should download the Schedule program into the service provider again, because updating
software also clears Schedule program.

(1) Activate the PC tool [winIST_CN149] on your PC.


(2) Click [Export/Import] from MENU LIST. Then, the column of [Export/Import] is displayed in
the right side of the screen (refer to Fig.2).

-3-
Attachment4

Fig.2 Export/Import screen

(3) Click [EXPORT] of [Export/Import] column in Fig.2 (Fig.3 is displayed).

Fig.3 [Export Data Is Saved As] dialog box

-4-
Attachment4

(4) Enter the name of Export file and click [Save] (Fig.4 is displayed).

Fig.4 Export confirmation dialog box

(5) Click [Yes] in Fig.4. Then the Export is started and Fig.5 is displayed.

Fig.5 Export progressing status confirmation dialog box

(6) Fig.6 is displayed when the Export is completed. Click [OK].

Fig.6 Export completion dialog box

-5-
Attachment4

3) Maintenance Number confirmation before upgrading


(1) Activate the PC tool [winIST_CN149] on your PC.
(2) Click [Alarm Pack] from MENU LIST. Then, the column of [Alarm Pack] is displayed in the
right side of the screen (refer to Fig.7).

Fig.7 Alarm Pack screen

-6-
Attachment4

(3) Click READ button.

Fig.8 Confirmation of Maintenance Number

(4) Confirm that Model is "JUE-85-A".


(5) Confirm that Maintenance Number in ACSE Main.

When Maintenance Number is "10.55", the upgrade of ACSE software is unnecessary.

-7-
Attachment4

4) ACSE(EME) software upgrading

(1) Activate PC tool [winIST_CN149] on the PC.


(2) Click [Update] from MENU LIST. [Update] column is displayed in right side (refer
to Fig.9).

Fig.9 Update screen

(3) Select [ACS] in the [Update] column of [Target] (refer to Fig.10).

Fig.10 Selecting Target

-8-
Attachment4

(4) When the dialog box of Fig.A1.2.1.3c is displayed, turn OFF the power switch of the IME. And
click [OK] after the LED of the IME is automatically turned off.

Fig.11 IME power OFF dialog box

(5) When the dialog box of Fig.12 is displayed, turn ON the power switch of the IME.

Fig.12 IME power ON dialog box

(6) The dialog box of Fig.A1.2.1.3e is displayed when the acquisition of terminal software
information is succeeded. Click [OK].

Fig.13 Acquisition of terminal information succeeded dialog box

-9-
Attachment4

(7) When [OK] button in Fig.13 (dialog box) is clicked, the screen is returned to ACSE/IME
software updating screen and [Old module OK] is displayed in the [Information] column of
[Old] (refer to Fig.14).

Fig.14 Update screen displayed after Old information acquisition

(8) Click [FILE SELECT] button and display [File Select] dialog box (refer to Fig.15).

Fig.15 File Select dialog box

- 10 -
Attachment4

(9) When ACSE software [JUE85-A_ACS1055.jrc] is selected at Fig.15, the screen is return to
ACSE/IME software updating screen and [It is possible to update!] is displayed in the lower
part of [Update] column (refer to Fig.16).

Fig.16 Update screen - selected new file

(10) Click [Update] button at Fig.16 (Fig.17 is displayed).

Fig.17 Update confirmation dialog box

- 11 -
Attachment4

(11) Click [Yes] in Fig.17. Then the updating is started and Fig.18 is displayed during updating.

Fig.18 Updating progressing status display dialog box

When the power source of the terminal is turned off during upgrade, repeat the procedure from (3).

(12) Fig.19 is displayed when updating is completed. Click [OK].

Fig.19 Update completion dialog box

(13) Restart Inmarsat-C terminal in a power switch of IME.

- 12 -
Attachment4

5) Maintenance Number confirmation after upgrading


(1) Activate the PC tool [winIST_CN149] on your PC.
(2) Click [Alarm Pack] from MENU LIST. Then, the column of [Alarm Pack] is displayed in the
right side of the screen (refer to Fig.20).

Fig.20 Alarm Pack screen

- 13 -
Attachment4

(3) Click READ button.

Fig.21 Confirmation of Maintenance Number

(4) Confirm that Model is "JUE-85-A".


(5) Confirm that Maintenance Number in ACSE Main is "10.55".

- 14 -
Attachment4

6) SRAM/FROM Clear
(1) Activate the PC tool [winIST_CN149] on your PC.
(2) Click [SRAM/FROM Clear] from MENU LIST. Then, the column of [SRAM/FROM Clear] is
displayed in the right side of the screen (refer to Fig.22).

Fig.22 SRAM/FROM Clear screen

(3) Click [SRAM Clear] Start button. Fig.23 is displayed. Click [OK].
(4) Click [FROM Clear] Start button. Fig.24 is displayed. Click [OK].

 
Fig.23 SRAM Clear screen Fig.24 FROM Clear screen

(5) Restart Inmarsat-C terminal in a power switch of IME.

- 15 -
Attachment4

7) Import
(1) Activate the PC tool [winIST_CN149] on your PC.
(2) Click [Export/Import] from MENU LIST. Then, the column of [Export/Import] is displayed in
the right side of the screen (refer to Fig.25).

Fig.25 Export/Import screen

(3) Click [IMPORT] of [Export/Import] screen at Fig.25 (Fig.26 is displayed).

- 16 -
Attachment4

Fig.26 Import File Select dialog box

(4) Enter the name of Import file and click [Open] in Fig.26 (Fig.27 is displayed).

Fig.27 Import confirmation dialog box

(5) Click [Yes] at Fig.27. Import is started (Fig.28 is displayed).

Fig.28 Import progressing status dialog box

- 17 -
Attachment4

(6) Fig.29 is displayed when the importing is completed. Click [OK].

Fig.29 Import completion dialog box

(7) Restart Inmarsat-C terminal in a power switch of IME.

- 18 -
Attachment5

JUE-87 IME (NTF-318)’s DTE Software


Recovery Upgrade Procedure
April 24, 2017
Maritime Solution Group
Marine Solution Engineering Department

1. Outline
This manual explains recovery upgrade procedure of Inmarsat-C JUE-87 IME (NTF-318)’s
DTE software.

2. Preparation
1) Prepare below parts
x USB Flash memory

2) Prepare below files on your USB Flash memory.


Put the files in each specified directory.
ձĂJUE-87 IME (NTF-318)
x JUE-87 DTE software 㸸 JUE87_DTE_PLAIN_0113.BIN
(Directory 㸸 “\JUE-87\DTE\”)
x Auxiliary file for recovery 㸸 update_desc.txt
(File Content: 1 \JUE-87\DTE\JUE87_DTE_PLAIN_0113.BIN)
(Directory 㸸 “\”)

NOTE
࣭It is necessary to put the files (DTE software and auxiliary file for recovery) in each
specified directory. The DTE cannot be upgraded when the files are putted in
incorrect directory.
࣭DTE recovery software for JUE-87 IME (NTF-318) and JUE-85 DTE (NDZ-227) is the
same file name, however, is not different from the file content.

-1-
Attachment5

3. Procedure
(1) Turn on the JUE-87.
(2) Recovery mode will be initiated automatically (refer to Fig.1).

Fig.1 Initial state of recovery mode

(3) Insert the USB Flash memory which includes DTE software and auxiliary file for
recovery to the DTE. Upgrading will be started automatically after insert the USB
Flash memory.*1)

*1) For reference, if the DTE is turned on after the USB Flash memory is inserted,
upgrading will be started automatically too.

 (4) Fig.2 will be displayed after upgrading is finished. The DTE will be rebooted
30 seconds after Fig.2 is displayed.

Fig.2 Upgrade finish state of recovery mode

NOTE
Even when that's an upgrade of JUE-87 DTE software, indication of a screen is
NDZ-227C. That's normal.

-2-