BILL NO.

2 - SINGLE STOREY TERRACE HOUSE (160 UNIT)

Intermediate Unit
Item Description Unit Rate Type A
(RM) Qty. Amount (RM)

PLUMBING

A The Contractor shall take note that this section of the


Bills of Quantities will be on a lump sum basis (without
quantities) based on the Drawings and Specification (PL). Note -

B The Drawings are intended to show the general


arrangement and requirement of the Works. The
Contractor shall be require to produce shop drawing with
sufficient calculation, information and data before
commencement of the work for the S.O. approval. Any
approval or comments made by the S.O. will not relieve
the Contractor of his responsibility to comply with Authority
requirements and are not entitle for any claims or
extension of time (PL). Note -

C Each items shall be priced individually. The monetary


value of any items left unpriced shall be deemed to have
been included elsewhere in the Tender and complete to
true intent and meaning of the Drawings and Specification,
Authority requirements and satisfaction of the S.O. (PL). Note -

GENERALLY

The Contractor shall deem to include the following in their


pricing :-

D All visible pipework shall be painted with approved paint


(PL). Item -

C/fwd RM

B/fwd RM

PLUMBING (Cont'd)
A All pipes passing through R.C. floor slabs, R.C. wall and
R.C. beams shall be contained with pipe sleeve one (1)
diameter larger and shall be sealed with approved fire
resisting materials and shall be water tight finish (PL). Item -

B All pipes through roof shall be provided with approved


collar and flashing and shall be water tight finish (PL). Item -

C All soil, waste and vent pipes shall be provided with


cleaning eyes for servicing and cleaning and shall be
suitably supported (PL). Item -

COLD WATER SERVICES

High density polyethylene (HDPE) pipes and fittings to


M.S. 1058 butt fusion welded together including all
necessary excavation, backfilling, short lengths, stub ends,
slip-on nuts, gaskets and the like all to the manufacturer's
recommendations and instructions

D 32mm Diameter (OD) pipe (PL). LS

C/fwd RM

B/fwd RM

PLUMBING (Cont'd)

EXTRA OVER HDPE pipe for

A 32mm x 33.4mm x 32mm Diameter (OD) tee (PL). LS

B 32mm x 32mm x 32mm Diameter (OD) tee (PL). LS

C 32mm x 26.6mm x 32mm Diameter (OD) tee (PL). LS

AB-3P pipes and fittings to the manufacturer's


recommendations and instructions
D 26.6mm Diameter (OD) pipe (PL). LS

E 33.40mm Diameter (OD) pipe (PL). LS

F 48.10mm Diameter (OD) pipe (PL) LS

C/fwd RM

B/fwd RM

PLUMBING (Cont'd)

EXTRA OVER AB-3P pipe for

A 26.60mm Diameter (OD) elbow (PL). LS

B 33.40mm Diameter (OD) elbow (PL). LS

C 48.10mm Diameter (OD) elbow (PL). LS

D 26.60mm x 26.60mm x 26.60mm Diameter (OD) tee (PL). LS

E 33.40mm x 33.40mm x 33.40mm Diameter (OD) tee (PL). LS

F 48.10mm x 48.10mm x 48.10mm Diameter (OD) tee (PL). LS

STAINLESS STEEL PIPES AND FITTINGS COMPLETE


WITH ALL NECESSARY ACCESSORIES INCLUDING
JOINTING, ALL TO THE MANUFACTURERS'
INSTRUCTIONS AND RECOMMENDATIONS AND PBA
APPROVAL

G 20mm diameter meter position for construction use to


PBA's approval complete with and including 12mm meter,
long screw, 20mm brass stopcock, 20mm lockable valve,
barrel nipple, jam-nut, 20mm elbow, straight elbow etc.,
overall length 520mm long complete with 3mm thick
aluminium/brass permanent address plate with engraved
lettering including stainless steel screw, all as per drawing
No 1

C/fwd RM

B/fwd RM

PLUMBING (Cont'd)

Brass work to comply with B.S. 1010 and jointing to pipe


as described

A 26.6mm Diameter (OD) approved stopcock (PL). LS

B 33.40mm Diameter (OD) approved gate valve (PL). LS

C 48.10mm Diameter (OD) approved gate valve (PL). LS

Water storage tank

D Approved polytank water storage tank of 300 gallons effective


capacity with removable cover, water level indicator and
warning pipe to PBA approval on and including necessary
plinth supporting 100x50x1.6mm thick RHS@150mm centre to
centre with 10mm thick plywood and hoisting and necessary
fixing in position approximately 7.00m above ground level as shown
on dwrg PBHR/181/JKP/T.ILMU/Pb-08 as as directed and approve
by the S.O.(PL). No 1

E Approved high pressure equilibrium ball valve, overflow and scour


pipe to discharge to nearest toilet all as directed and approve by the
S.O.'(PL). LS

SUNDRIES

F Labour and material for connection and jointing to water meter


including brass elbow, coupling, barrel nipple, jam-nut, 50mm
diameter brass stopcock and all necessary fixing accessories, all to
the approval of the S.O. and PBA (PL). No 1

C/fwd RM

B/fwd RM

SANITARY

Unplasticised polyvinyl chloride (UPVC) pipes and fittings


to B.S. 4514 and B.S. 5255 jointed with the manufacturer's
approved solvent cement & fixed to horizontal and vertical
surfaces with approved fixing all in accordance with the
manufacturer's instructions

A 50mm Diameter pipe (PL). LS

B 100mm Diameter pipe including all necessary excavatiion


of trench, bacfilling and concrete bed LS

EXTRA OVER UPVC pipe for

G 50mm Diameter bend (PL). LS

H 100mm Diameter bend (PL). LS

C/fwd RM

B/fwd RM

SANITARY (Cont'd)
A 100mm x 100mm x 100mm Diameter tee (PL). LS

SUNDRIES

B Approved wire cowl and grating to suit 100mm diameter


vent pipe and jointing (PL). LS

C Approved 100mm diameter VCP accessible


gully trap with 1 No. 100mm diameter outlet, 1 No. 50mm
diameter inlet complete with chamber of internal size
300mm x 300mm with 550mm x 550mm x 50mm thick
vibrated reinforced concrete Grade 20 base, sides with
50mm thick vibrated reinforced concrete Grade 20 wall,
350mm x 350mm x 25mm thick precast concrete Grade
20 removable cover slab complete with mild steel grating
over gully trap and surrounded trap with vibrated reinforced
concrete Grade 20 including all necessary excavation,
formwork and jointing to pipe as per Drawing No. :
PBHR/181/JKP/T.ILMU/Si-DT-04 No 2

D Labour and material for forming 50mm diameter opening


for pipe through gully trap wall (PL). No 2

E Labour and material for forming 100mm diameter


opening for pipe through gully trap wall (PL). No 2

C/fwd RM

C/fwd RM

TESTING

C Allow for testing of foregoing cold water and sanitary


plumbing services including sanitary fittings, and make
good any defect and leave the whole of the installation in
perfect working order to the entire satisfaction of the
Architect and Local Authorities (PL). Item -

D Any other items not specified

i)
ii)

iii)

TO GENERAL SUMMARY RM

BILL NO. 3 - EXTERNAL WORKS WITHIN LOT BOUNDARY

Item Description Unit Qty Rate


(RM)

FOUL DRAINAGE

Excavate, get out, part return, fill in, well ram and
remainder load and cart away from site, level, grade and
ram bottom, trim sides and including planking and strutting

F Excavate trench for 100mm diameter pipe and 750mm


wide bed under not exceeding 1.50m deep and average
0.85m deep (DR). M 802

C/fwd RM

B/fwd RM

SITEWORK (Cont'd)

Selected compacted crusher run of size 5mm to 20mm


diameter as described spread, levelled and well
compacted to receive pipe

A 450mm x 225mm Thick (overall) in bed and surround to pipe


including all necessary formwork and break joints (DR). M 802

Selected and approved earthfilling with selected imported


earth material, spread, levelled, well rammed and
consolidated backfilling as described

B 450mm Wide x 375mm deep on top and surround to pipe


(DR). M 802

Vitrified clay pipe and fittings to B.S. 65 (Extra Strength)


with spigot joints to B.S. 540 : Part 1, incorporating
rubber 25mm thick soft board rings flexible joint to B.S.
2494 laid to fall to manufacturer's instruction

C 100mm Diameter pipe laid to fall and jointed in trench (DR). M 802

HOUSE MANHOLE

The following in 160 Nos. manhole of internal size 600mm


x 450mm generally constructed of concrete base and
brick sides

D Excavate for manhole not exceeding 1.50m deep get out,


part return, fill in and well ram and remainder load and cart
away from site including all levelling or grading & ramming
of bottom, trimming sides and planking and strutting (DR). M3 179

E 50mm Thick lean concrete Grade 15 blinding under base


slab with surfaces finished level to receive concrete (DR). M2 143

F 100mm Thick vibrated reinforced concrete Grade 25 as


described in base slab (DR). M2 143

G 100mm Thick vibrated reinforced concrete Grade 25 as


described in slab (DR). M2 46

H 300mm Thick (average) plain concrete Grade 15 as


described in benching to bottom laid to slope and suite all
main and branch channel (DR). M2 43

C/fwd RM

B/fwd RM

SITEWORK (Cont'd)

A B.R.C. mesh reinforcement No. A7 as described in base


slab (measured nett and no allowance made for laps) (DR). M2 143

B B.R.C. mesh reinforcement No.A7 as described in slab


(measured nett and no allowance made for laps) (DR). M2 46

C Sawn formwork as described to edge of slab not


exceeding 100mm high (DR). M 815

D Sawn formwork as described to edge of base slab


exceeding 100mm and not exceeding 200mm high (DR). M 607

E EXTRA OVER for forming 50mm x 50mm high rebated on


top of slab (DR). M 479

F 112mm Thick wall in well burnt clay brick in cement and


sand (1:3) mortar (DR). M2 684

100mm Diameter half round vitrified clay pipe curved main


G channel bedded and jointed in cement and sand (1:3)
mortar (DR). M 352

H 12mm Thick rendering high alumina cement as described


internally to sides of brickwall (DR). M2 281

J 12mm Thick cement and sand (1:2) rendering as described


to benching finished to slope trowelled smooth with coves
at walls and rounded edges at junction with channel
including working carefully to top edge of channel (DR). M2 43

K Approved light duty cast iron cover and frame size 600mm
x 450mm x 84 lbs with openable cover, setting in position
as described and sealing cover in grease (DR). No 160

Testing

L Allow for testing the foregoing foul drainage installation in


the presence of the Architect and the relevant Authorities
with water or by other means before trenches are filled in,
making good any defects, retest on completion and leave
the whole of the installation in perfect working order to the
entire satisfaction of the Architect and Authorities (DR). Item

C/fwd RM
Intermediate Unit End Unit Corner Unit
Type B Type A Type A Type C
Qty. Amount (RM) Qty. Amount (RM) Qty. Amount (RM) Qty. Amount (RM)

- - - -

- - - -

- - - -

- - - -
- - - -

- - - -

- - - -
1 1 1 1

1 1 1 1
1 1 1 1
2 2 2 2

2 2 2 2

2 2 2 2

- - - -
Amount
(RM)