Sie sind auf Seite 1von 6

U P S

Timely & Reliable

Hot Water Pump Discharge

ER
ILL
CH
M
VA

HOT WATER

17. DUMMY FLANGES NOS 100 02


16. AUTO AIRVENT NOS
15. DRAIN VALVES NOS
14. TEMPERATURE GAUGE NOS
13. PRESSURE GAUGE NOS 01
12. TEST POINT NOS 01
11. WATER FLOW SWITCH NOS 01
10. NRV NOS
9. Y-STRAINER NOS
8. BALANCING VALVE NOS
7. MOTORISED-BFV NOS
6. BUTTERFLY VALVES NOS 100 01
5. BELLOWS NOS
4. FLANGES NOS 100 02
3. REDUCER NOS
2. BENDS NOS 100 03
1. PIPES RMT 100 23.065

SI NO QUANTITY AS FABRICATION CERTIFICATION ERECTION CERTIFICATION


DESCRIPTION UNITS REMARKS
PER DRAWING QUANTITY AS PER SITE CONDITION
LINE NO: APL-VAM CHILLER-HOT WATER SUPPLY HEADER
Hot Water Return Tank
U P S
Timely & Reliable

ER
ILL
CH
M
VA

HOT WATER

17. DUMMY FLANGES NOS


16. AUTO AIRVENT NOS
15. DRAIN VALVES NOS
14. TEMPERATURE GAUGE NOS
13. PRESSURE GAUGE NOS 01
12. TEST POINT NOS 01
11. WATER FLOW SWITCH NOS 01
10. NRV NOS
9. Y-STRAINER NOS
8. BALANCING VALVE NOS
7. MOTORISED-BFV NOS
6. BUTTERFLY VALVES NOS 100 01
5. BELLOWS NOS
4. FLANGES NOS 100 02
3. REDUCER NOS
2. BENDS NOS 100 03
1. PIPES RMT 100 13.590

SI NO QUANTITY AS FABRICATION CERTIFICATION ERECTION CERTIFICATION


DESCRIPTION UNITS REMARKS
PER DRAWING QUANTITY AS PER SITE CONDITION
LINE NO: APL-VAM CHILLER-HOT WATER RETURN HEADER
Hot Water Supply Tank

U P S
Timely & Reliable

Discharge Header

Pump - 02 Suction

ary FL
r im
P
a ter -01
t W mp
Ho Pu

PRIMARY PUMP
SUCTION & DISCHARGE

17. DUMMY FLANGES NOS 01


16. AUTO AIRVENT NOS
15. DRAIN VALVES NOS 01
14. TEMPERATURE GAUGE NOS
13. PRESSURE GAUGE NOS 02
12. TEST POINT NOS
11. WATER FLOW SWITCH NOS
10. NRV NOS 100 01
9. Y-STRAINER NOS 100 01
8. BALANCING VALVE NOS
7. MOTORISED-BFV NOS
6. BUTTERFLY VALVES NOS 100 02
5. BELLOWS NOS 100 02
4. FLANGES NOS 100 12
3. REDUCER NOS 100 02
2. BENDS NOS 100 02
1. PIPES RMT 100 5.733

SI NO QUANTITY AS FABRICATION CERTIFICATION ERECTION CERTIFICATION


DESCRIPTION UNITS REMARKS
PER DRAWING QUANTITY AS PER SITE CONDITION
LINE NO: APL-HOT WATER PRIMARY PUMP-01
Hot Water Supply Tank

U P S
Timely & Reliable

Discharge Header

Pump - 01 Suction

ary FL
r im
rP
Wate p-02
t m
Ho Pu
PRIMARY PUMP
SUCTION & DISCHARGE

17. DUMMY FLANGES NOS


16. AUTO AIRVENT NOS
15. DRAIN VALVES NOS 01
14. TEMPERATURE GAUGE NOS
13. PRESSURE GAUGE NOS 02
12. TEST POINT NOS
11. WATER FLOW SWITCH NOS
10. NRV NOS 100 01
9. Y-STRAINER NOS 100 01
8. BALANCING VALVE NOS
7. MOTORISED-BFV NOS
6. BUTTERFLY VALVES NOS 100 02
5. BELLOWS NOS 100 02
4. FLANGES NOS 100 12
3. REDUCER NOS 100 02
2. BENDS NOS 100 01
1. PIPES RMT 100 2.763

SI NO QUANTITY AS FABRICATION CERTIFICATION ERECTION CERTIFICATION


DESCRIPTION UNITS REMARKS
PER DRAWING QUANTITY AS PER SITE CONDITION
LINE NO: APL-HOT WATER PRIMARY PUMP-02
Hot Water Return Tank

U P S
Timely & Reliable

Discharge Header
To Solar Panel

Pump - 02 Suction

ry
nd
a FL
e co
S 1
a ter p-0
t W Pum
Ho

SECONDARY PUMP
SUCTION & DISCHARGE

17. DUMMY FLANGES NOS 01


16. AUTO AIRVENT NOS
15. DRAIN VALVES NOS 01
14. TEMPERATURE GAUGE NOS
13. PRESSURE GAUGE NOS 02
12. TEST POINT NOS
11. WATER FLOW SWITCH NOS
10. NRV NOS 100 01
9. Y-STRAINER NOS 100 01
8. BALANCING VALVE NOS
7. MOTORISED-BFV NOS
6. BUTTERFLY VALVES NOS 100 02
5. BELLOWS NOS 100 02
4. FLANGES NOS 100 12
3. REDUCER NOS 100 02
2. BENDS NOS 100 02
1. PIPES RMT 100 5.733

SI NO QUANTITY AS FABRICATION CERTIFICATION ERECTION CERTIFICATION


DESCRIPTION UNITS REMARKS
PER DRAWING QUANTITY AS PER SITE CONDITION
LINE NO: APL-HOT WATER SECONDARY PUMP -01
Hot Water Return Tank

U P S
Timely & Reliable

Discharge Header
To Solar Panel
Pump - 02 Suction

ry
n da FL
co
r Se 2
te p-0
t Wa um
Ho P
SECONDARY PUMP
SUCTION & DISCHARGE

17. DUMMY FLANGES NOS


16. AUTO AIRVENT NOS
15. DRAIN VALVES NOS 01
14. TEMPERATURE GAUGE NOS
13. PRESSURE GAUGE NOS 02
12. TEST POINT NOS
11. WATER FLOW SWITCH NOS
10. NRV NOS 100 01
9. Y-STRAINER NOS 100 01
8. BALANCING VALVE NOS
7. MOTORISED-BFV NOS
6. BUTTERFLY VALVES NOS 100 02
5. BELLOWS NOS 100 02
4. FLANGES NOS 100 12
3. REDUCER NOS 100 02
2. BENDS NOS 100 01
1. PIPES RMT 100 2.763

SI NO QUANTITY AS FABRICATION CERTIFICATION ERECTION CERTIFICATION


DESCRIPTION UNITS REMARKS
PER DRAWING QUANTITY AS PER SITE CONDITION
LINE NO: APL-HOT WATER SECONDARY PUMP -02