Sie sind auf Seite 1von 16

Electrical network management

PowerLogic
Energy management, revenue metering and power quality monitoring

Selection Guide
PowerLogic® energy & power management

Product selection guide to the world’s largest and most


advanced range of software and meters for helping any
organization understand and control energy-related costs,
risks and efficiencies.

PowerLogic has all the answers

30%
PowerLogic transforms
energy into an asset
Schneider Electric’s energy and
sustainability solutions support Effective monitoring
you at every stage of the energy and control systems can
management lifecycle.
save you up to 30% on
Reliable, comprehensive energy
your annual energy bill
management is a tremendous
asset, allowing you to redirect
resources to your core business.

2 plsed310031eN
Gain insight and control with PowerLogic™
PowerLogic energy and power management systems

PowerLogic systems cover the world’s largest and


most advanced range of software and metering
products for managing energy. These systems are
cost-effective because they have a low cost of
installation and ownership, are feature-rich and deliver
multiple financial benefits.
Products support important local and global standards,
including accuracy certifications and international
power quality compliance reporting. A PowerLogic
system acts like a layer of intelligence across all of your
energy assets, spanning power, building and process
systems. Key distribution points are monitored 24
hours a day, from generators and substations to service
entrances, mains, feeders and loads.
All real-time conditions, historical performance, and
aggregate consumption of all electrical and piped
utilities are unified into a single, accessible repository.
At the administrative level, acquired data is delivered as
timely, relevant information to anyone that needs it,
wherever they are. Powerful web-based portals give
multiple stakeholders responsive and easy-to-use
analytic, reporting, alarm annunciation and control
capabilities.
Whether it's a new installation or retrofit, a PowerLogic
solution fits seamlessly into your workflow, and
integrates tightly with other Schneider Electric power
and automation solutions.
It also shares information directly with your business
and accounting applications. Solutions are highly
scalable, letting you take advantage of modular
components to add to or upgrade your systems
affordably, as required.

15%
Industrial plants can save up
to 15 percent or even more on
process-related energy use,
and over 7 percent in total
utility costs, if opportunities
are properly identified and
For further information on all these products see
expertly addressed. the PowerLogic Catalogue (PLSED309005EN)
at www.schneider-electric.com

plsed310031eN 3
Applications for Supply and Demand

Cutting-edge technology to increase profitability


PowerLogic technology converts the complex dynamics governing the relationship between
power generation and distribution on the utility side, and energy consumption, cost and
reliability on the consumer side, into timely, easily understood information. Businesses can use
this powerful to improve tactical actions and strategic decision making.
From a single facility to an entire enterprise, PowerLogic meters monitor key distribution points
24 hours a day. Whether from generators, substations, service entrances, mains, feeders,
loads or third-party equipment and systems, PowerLogic technology tracks, records and
reports all real-time conditions and historical performance data. Intuitive web-based interfaces
give stakeholders access to this data, as well as advanced analytics, alarm annunciation and
control capabilities. It supports comprehensive energy management programs by tracking
performance and empowering you to make effective decisions.

Power availability & reliability Energy availability & reliability

bb Validate that power quality complies bb Improve T&D network reliability


with the energy contract
bb Enhance substation automation
bb Verify the reliable operation of power
and mitigation equipment bb Maximise efficiency of existing
infrastructure
bb Improve response to power-
related problems
Revenue metering & power
bb Leverage existing infrastructure quality
capacity and avoid over-building
bb Maximise metering accuracy at all
bb Support proactive maintenance to interchange points
prolong asset life
bb Verify compliance with new power
quality standards
Energy efficiency & cost savings
bb Analyse and isolate the source of
bb Measure efficiency, reveal power quality problems
opportunities and verify savings

bb Manage green house gas emissions

bb Allocate energy costs to departments


or processes

bb Reduce peak demand and power


factor penalties Your power monitoring system must
be an integral part of your overall
bb Enable participation in load business strategy. PowerLogic
curtailment programs (e.g. demand System fits in with your objectives
response) and expands your network's
capabilities with wide ranging,
bb Strengthen rate negotiation with
energy suppliers flexible deployment options to meet
all your energy management needs.
bb Identify billing discrepancies

bb Sub-bill tenants for energy costs

4 plsed310031eN
Complementary software solutions

StruxureWare™
Schneider Electric offers a proven platform of software applications and suites that help our
customers, in every segment and across all geographies, maximise their energy usage while
conserving their resources.

The depth of Schneider Electric software solutions makes it easy to match a product to your
needs, your facilities portfolio and your budget. As your business or energy management
program grows your energy solution can grow with you. Products are highly complementary
and interoperable, sharing information between platforms and benefits between users.

Each software product collects energy-related data from a variety of sources, including
PowerLogic meters, other devices and other systems. See the following pages for more detail
on features and compatibilities.

StruxureWare™ Power Monitoring Expert


Scalable power management software that delivers a reliable, flexible and high performance
monitoring and control solution designed to maximise operations efficiency, optimise power
distribution, and improve bottom-line performance.

StruxureWare™ PowerSCADA Expert


A reliable, flexible and high performance monitoring and control solution designed with
operational traceability and full system redundancy. Easy-to-use configuration tools and
powerful features enable faster development and deployment of any size of application.

PowerLogic products Ordering information


bb Suited for use in all electrical
Find more information on Schneider
environments and compatible with
PowerLogic software solutions Electric’s PowerLogic System
products, as well as our many other
bb Standardised configuration, energy management products and
flexible customisation, modular services, at:
I/O, communications and remote
display options www.schneider-electric.com

bb Support for international industrial See the PowerLogic Catalogue,


automation standards, form
document PLSED309005EN, or
factors and protocols
search the website using the part
bb Quick and easy installation in new numbers found at the end of this
or retrofit environments document.

bb Support proactive maintenance to Contact your SE representative for


prolong asset life complete ordering information.

plsed310031eN 5
Product selection guide Panorama of the PowerLogic
range

Current transformers Basic panel meters

CT Name iAMP / iVLT AMP / VLT iFRE iCH / iCI

current transformer Function ammeter, voltmeter frequency meter hour counter


pulse counter

Installation
b�insulated cable,
Applications
diameter 21 to 35 mm, Panel instrumentation
through transformer Panel instrumentation I/U I/U F hours /pulses
b�busbar through transformer
b�cable connections

Energy efficiency and cost


Sub billing and cost allocation
Demand and load management
Billing analysis

Power availability
and reliability
Compliance monitoring
Sag/swell, transient
Harmonics

Revenue metering
Revenue meter

Characteristics Characteristics
b�transformation ratio: Measurement accuracy class 1.5 ± 0.5 % ± 1 class 1.5 ± 0.5 % ± 1 digit
40/5 A to 6000/5 A digit
b�accuracy: class 0.5 to 3
Installation DIN rail DIN rail flush mounted DIN rail CI, CH: DIN rail
b�maximum rated
4 x 18 mm 2 x 18 mm 72 x 72 mm 2 x 18 mm 2 x 18 mm
operational voltage: 720 V AC modules modules 96 x 96 mm modules modules
b�tropicalised CH: flush mount
Voltage measurement VLT: VLT: VLT: 400 V AC direct
500 V AC direct 600 V AC direct 500 V AC direct
or external VT or external VT or external VT

Current measurement AMP: AMP: AMP:


30 A direct 10 A direct external CT
or external CT or external CT

Communication ports
Inputs / Outputs

Memory capacity

6 plsed310031eN
Product selection guide Panorama of the PowerLogic
range (continued)

Basic energy meters Multi-circuit metering

Name iEM2000/ iME1 /iME1z/ iEM3000 Series BCPM EM4800


iEM2010 iME1zr
/iEMw2000T
Function kilowatt-hour meters branch circuit monitor multi-circuit energy meter
IEC 61036 Class 1 Class 0.5 ANSI C12.1, C12.20
Class 0.5S IEC 62053-22

Applications
Panel instrumentation
Panel instrumentation E I, U, F, P, Q, S, PF, E I, U, F, P, Q, S, PF, E
(Power demand and (Power demand and
current demand) current demand)

Energy efficiency and cost


Sub billing and cost allocation
Demand and load management
Billing analysis

Power availability
and reliability
Compliance monitoring
Sag/swell, transient
Harmonics

Revenue metering
Revenue meter

Characteristics
Measurement accuracy class 1 class 1 (mains active energy) Class 0.5S
Installed in panel or enclosure Installed in panel or
enclosure

Installation DIN rail 90 – 277 V Line to Neutral 80 - 480 V AC L-L without PTs,
1.2 or 4 x 18 mm modules voltage Inputs Up to 999 kV with external PTs
CT strips for branch circuits Split- or solid-core CTs
and external CTs for mains
Voltage measurement 400 V AC direct 1 for main 2
2

Current measurement 40 to 63 A direct


or external CT

Communication ports

plsed310031eN 7
Product selection guide Panorama of the PowerLogic
range (continued)

Basic multi-function metering

Name PM3000 Series PM5350 PM5100/PM5300/


PM5500
Function metering & sub-metering Class 0.5S IEC 62053-22 metering & sub-metering
Class 0.5S IEC 62053-22 Class IEC 61000-4-2 Class 0.5S
Class 1 IEC 62053-21 Class IEC 61000-3-3 IEC 62053-22
Class 2IEC 62053-23 Class 0.2S (PM55xx)
IEC 62053-22
Class 1/2 IEC 62053-24

Applications
Panel instrumentation
Panel instrumentation I, U, F, P, Q, S, PF, E I, U, F, P, Q, S, PF, E I, U, F, P, Q, S, PF, E
(Power demand and (Power demand and (Power demand and
current demand) current demand) current demand)

Energy efficiency and cost


Sub billing and cost allocation

Demand and load management

Billing analysis

Power availability & reliability


Harmonics

Dip/swell, transient

Compliance monitoring

Revenue metering
Revenue metering

Characteristics
Measurement accuracy Class 0.5 Class 0.5 Class 0.2S (PM55xx)
(active energy) Class 0.5S
Installation DIN rail Flush mount Flush mount
96 mm x 96 mm 96 mm x 96 mm

Voltage measurement 50V to 330V AC (Ph-N) 20-480 V AC (L-L) 20 V L-N / 35 V L-L to 277 V L-N
80V to 570V AC (Ph-Ph) 20-277 V AC (L-N) /480 V L-L
up to 1MV AC (ext VT) /600 V L-L (PM55xx)

Current measurement external CT external CT external CT

Communication ports 1 1 2

Inputs / Outputs 2 I/O 4 I/O


6 I/O (PM55xx)
Memory capacity 256 kb
1.1 MB (PM55xx)

8 plsed310031eN
Product selection guide Panorama of the PowerLogic
range (continued)

Intermediate metering

Name PM810 PM820/ PM870 ION7330/7350 PM8000


PM850
Function energy and basic PQ power meter energy and basic PQ power meter energy and basic PQ meter
IEC 61557-12 IEC 61557-12 IEC 61557-12
PMD/SD/K70/0.5 PMD/SD/K70/0.5 IEC 62053-22
PMD/SS/K70/0.5 PMD/SS/K70/0.5 IEC 61000-4-30 Class S
ANSI 12.20 Class 0.2S real energy ANSI 12.20 Class 0.2S real energy IEC 62586 PQI-S
ANSI C12.20 Class 0.2
PMD/Sx/K70/0.2

Applications
Panel instrumentation
Panel instrumentation I, U, F, P, Q, S, PF, E, THD, Min/Max, I, U, F, P, Q, S, PF, E, THD, harm, alarm, I, U, F, P, Q, S, PF, E, THD, Min/Max,
harm, alarm, I/O (I, U unbalance, I/O harm, alarm, I/O (I, U unbalance,
demand, clock/cal (PM810 w/PM810LOG) (Power demand and demand, clock/cal
current demand)

Energy efficiency and cost


Sub billing and cost allocation

Demand and load management

Billing analysis

Power availability & reliability


Harmonics w/PM810LOG

Dip/swell, transient dip/swell

Compliance monitoring PM850 only

Revenue metering
Revenue metering

Characteristics
Measurement accuracy ANSI 62053-22 Class 0.5S Class 0.5S ANSI 62053-22 Class 0.5S
(active energy) ANSI 12.20 Class 0.2S ANSI 12.20 Class 0.2S
Installation Flush & DIN rail mount Flush & DIN rail mount Flush & DIN rail mount
96 mm x 96 mm 96 mm x 96 mm 96 mm x 96 mm
TRAN 60 x 100 x 164.5 mm
Voltage measurement 0-347 VAC L-N 3P (0-600 VAC L-L) 50-347 V AC L-N 3P (87-600 L-L) 57-400 VAC L-N 3P
50-300 V AC L-N 1P (100-600 L-L) (100-690 VAC L-L)

Current measurement external CT external CT external CT external CT external CT external CT

Communication ports 1 - 4 (option) 1 - 4 (optionw) 1 - 4 (options) 3 3 2

Inputs / Outputs 18 I/O 18 I/O 18 I/O 8 I/O 8 I/O up to 27 DI, 9 DO


up to 16 AI, 8 AO
Memory capacity 80 kb with 80 / 800 kb 800 kb 300 kb 300 kb 512 MB
PM810 LOG

plsed310031eN 9
Product selection guide Panorama of the PowerLogic
range (continued)

Advanced metering Advanced utility metering

Name ION7550 ION7650 CM4000T ION8650 ION8800


A B C A B C
Function energy & power quality meter energy & power quality meter energy & power quality meter energy & power quality meter
IEC 62052-11 IEC 62053-22 IEC 62052-11 IEC 62052-11
IEC 62053-22/23 ANSI 12.20 Class 0.2S real IEC 62053-22/23 IEC 62053-22/23
Class 0.2S energy Class 0.2S Class 0.2S
IEC 61000-4-30 Class A IEC 61000-4-30 Class A IEC 61000-4-30
Applications
Panel instrumentation
Panel instrumentation I, U, F, P, Q, S, PF, E (demand, minimum and maximum values) I, U, F, P, Q, S, PF, E (demand, minimum and maximum
values)

Energy efficiency & cost


Sub billing and cost allocation

Demand and load management

Billing analysis

Power availability & reliability


Harmonics

Dip/swell, transient

Compliance monitoring

Revenue metering
Revenue metering

Characteristics
Measurement accuracy Class 0.2S Class 0.2S Class 0.2S Class 0.2S
(active energy)
Installation DIN 192 ANSI socket mount 9S, 35S, DIN 43862 rack
standard cutout 36S, 39S and 76S; FT21
(186 x 186 mm) switchboard case
Voltage measurement 57-347V L-N AC or 0 to 600 V AC 57-277V L-N AC 57-288V L-N AC or
100-600V L-L AC 0 to 1200 kV AC (ext. VT) (9S, 36S); 99-500V L-L AC
120-480 V L-L AC (35S)

Current measurement external CT external CT external CT external CT

Communication ports 5 3 5 5

Inputs / Outputs up to 32 I/O up to 25 I/O up to 22 I/O up to 16 I/O

Memory capacity up to 10 MB up to 32 MB 10 MB 4 MB 2 MB up to 10 MB

10 plsed310031eN
Product selection guide Panorama of the PowerLogic
range (continued)

Communications Monitoring Software

Name Com'X 200 EGX100/300 ION7550 RTU StruxureWare™ StruxureWare™


Power Monitoring PowerSCADA
Expert Expert
Function Ethernet GPRS data Ethernet Integrate Ethernet Power management Network protection
logger gateway server gateway-server + and control
onboard I/O

Features
RS485 / Ethernet gateway
Devices supported EM3000 Series, iEM3000 Acti 9 Smartlink, ION8800, ION7550/7650, ION8800, Sepam Series 40
Series, PM800 Series, BCPM Series, Modbus devices ION8650, PM800 Series
ION7300, CM Series PM5350 ION7550/7650, BCPM/BCM42
Acti 9 Smartlink Masterpact, PM800 Series, CM4000 PM8000 ION7550RTU, CM4000 Series
Series,
PM5000 Series, Compact DM6000, DM6300,
PM800 Series, PM5350
NSX, iEM3000 Series, EM1200, PM5000
iEM1, ION8600, ION8800, CM4000 Series, PM8000
iEM2000, ION7550/7650, BCPM,
iEM3000, PM1000, PM200, PM300, PM5000, PM8000
PM3000 Series PM5350, PM700, PM800, Sepam Series,
Sepam Series, Compact NSX,
Compact NSX, Vigilohm IM20,
Vigilohm IM20/IM20-H
Modicon Mementum M1
PM5350, PM8000
- TR8,
Twido Modular PLC

Web server with (Configuration only) (Configuration only)


standard HTML pages

Web server with EGX300 only


custom HTML pages

Real time data EGX300 only


Historical data Export to Internet database EGX300 only
server
Automatic notification
Alarm and event logs
Waveform display
Custom animated graphics
Manual/automatic reports

Characteristics
Ethernet ports 2 10/100 Base 10/100 Base StruxureWare™ StruxureWare™
Modbus TCP/IP protocol TX port TX port Power Monitoring PowerSCADA Expert
Expert is a complete, is an electrical
RS485 (2-wire / 4-wire) ports 1 1 1
interoperable, and distribution network
Modbus protocol
scalable supervisory monitoring and control
Number of devices 32 modbus devices 32 64 software dedicated to software that
connected directly 6 pulse meters (or dry power monitoring enhances power
contacts) – 2 analogue that enables you to system reliability and
sensors maximize operational operational efficiency.
efficiency, optimize Its architecture
RS232 configuration ports 1 1 power distribution combines proven
Miscellaneous Connectivity: WiFi, Serial line to Ethernet modem port systems, and expertise in electrical
GPRS,or Ethernet connectivity I/O (24 I/30 O max) improve bottom-line distribution with the
performance. speed and control
of high-performance
Installation DIN rail DIN rail DIN 192 cutout SCADA to reduce
(186 x 186 mm) outages.

plsed310031eN 11
Product selection guide Software introduction

A choice of powerful, effective solutions


PE86202

Schneider Electric’s StruxureWare™ software offerings give you desktop access to


your entire electrical network. They convert energy-related data into timely,
actionable information and give you the control to act on your decisions. The depth of
different offerings makes it easy to match a product to your goals, your business and
your budget.

vvStruxureWare Power Monitoring Expert software is a complete power


management solution that helps you maximise energy efficiency, cut energy-related
costs and avoid power-quality related equipment failures and downtime.
StruxureWare Power Monitoring Expert software
vvStruxureWare PowerSCADA Expert software is a power monitoring and
control solution with high reliability and performance for helping reduce the risk of
power outages and increase network-wide efficiency.
PE86231

Extensive reach and flexibility


Software forms an important part of your overall energy efficiency and reliability
solutions from Schneider Electric. Your system should grow with your business,
giving you the level of energy intelligence and control you need to reduce energy
consumption and costs, minimise environmental impacts, and assure power
availability, uptime and safety.
StruxureWare PowerSCADA Expert software
Each product collects energy-related data from a variety of sources, including
PowerLogic or third-party meters and sensors. Some products offer integration with
other Schneider Electric or third-party automation systems, and other energy-
relevant information feeds.

Choosing your solution


This section provides a brief overview of the types of environments and applications
each software offer is best suited for. See the following StruxureWare product
sections for more detail on specific product features and compatibilities. Your
Schneider Electric representative can help you design the best solution by choosing
the best product and associated services for your needs.

Use StruxureWare Power Monitoring Expert:


bb When Energy reporting is required, such as load profile, demand management, or
cost allocation
bb When Power Quality analysis and reporting is required
bb When on-board, time-stamped interval logs are required (e.g. billing applications)
bb When a pre-engineered, plug & play solution is desired
bb When the end-user wants the ability to modify and maintain the system on their own

Use StruxureWare PowerSCADA Expert :


bb When Substation Automation protocols are required: IEC61850, DNP3, IEC104
bb When critical, deterministic time response is required (high speed alarms/control)
bb When application (i.e. software) redundancy is required
bb When dynamic bus-bar colorization is required through an advanced state
machine
bb When the application is primarily real-time graphics and alarm oriented, and a
highly engineered solution is required

Or use both:
bb When your requirements need a combination of functions ie.  
bb Substation Protocols and Power Quality Analysis
bb Software Redunancy for ION metering applications

12 plsed310031eN
Product selection guide Software selection

Environment Application category

Software Industry Buildings Data


centres
Infra-
structure
Electric
utilities
Energy
efficiency
Power
availability
Network
protection
& cost & reliability & control
StruxureWare
Power Monitoring Expert bbb bbbb b
StruxureWare
PowerSCADA Expert bb bbbb
The number of square bullets indicates the relative strength of feature set for the noted application category.

Applications for industry, buildings, data centres and infrastructure


Category Application StruxureWare StruxureWare
Power Monitoring Expert PowerSCADA Expert

Energy usage analysis bb b


Cost allocation b
Energy efficiency
Procurement optimisation b
& cost Peak demand reduction bbb bb
Demand response and curtailment bbb bb
Power factor correction bbb
Electrical distribution (ED) asset optimisation bbb b
Power availability
Power quality analysis and compliance bbb b
& reliability ED commissioning, monitoring, and troubleshooting bbbb bbb
ED alarming and events bbb bbb
ED automation and control bb bbbb
Network Load management and shedding b b
protection
& control Redundancy bbbb
High reliability and time performance bbbb
The number of square bullets indicates the relative strength of feature set for the noted application.

Applications for electric utilities


Category Application StruxureWare StruxureWare
Power Monitoring PowerSCADA
Expert Expert

Power quality analysis and compliance bbb


Power availability
& reliability
Electrical distribution (ED) commissioning, monitoring and troubleshooting b bbbb
ED alarming and events bb bbb
ED automation and control b bbbb
Network Load management and shedding b bb
protection
& control Redundancy bbbb
High reliability and time performance bbbb
The number of square bullets indicates the relative strength of feature set for the noted application.

plsed310031eN 13
Product selection guide Index of catalogue numbers
Contact your Schneider Electric representative for
further information and ordering procedure.

Cat. no. Description Cat. no. Description


15100 BCPMSCB84S 84 split-core CTs, Intermediate BCPM
15125 CMV voltmeter selector switch, DIN rail BCPMSCC30S 30 split-core CTs, Basic BCPM
15126 CMA ammeter selector, DIN rail BCPMSCC42S 42 split-core CTs, Basic BCPM
15200 BCPMSCC60S 60 split-core CTs, Basic BCPM
15201 iVLT digital voltmeter, DIN rail BCPMSCC84S 84 split-core CTs, Basic BCPM
15202 iAMP direct reading digital ammeter, DIN rail BCPMSCCT0 Split core CTs, BCPM 50 A
15208 iFRE digital frequency meter, DIN rail BCPMSCCT0R20 Split core CTs, BCPM 50 A
15209 iAMP multi-rating digital ammeter, DIN rail BCPMSCCT1 Split core CTs, BCPM 100 A
15400 BCPMSCCT1R20 Split core CTs, BCPM 100 A
15440 iCH hour counter, DIN rail (230 V AC) BCPMSCCT3 Split core CTs, BCPM 200 A
15443 iCI impulse counter, DIN rail BCPMSCCT3R20 Split core CTs, BCPM 200 A
15600 C
15607 CH hour counter, 48 x 48 (24 V AC) CM4MA Circuit monitor CM4000T
15608 CH hour counter, 48 x 48 (230 V AC) CNV100 Circuit monitor CM4000T
15609 CH hour counter, 48 x 48 (12 to 36 V DC) E
A EBX200 Com'X 200 Ethernet data logger
A9M17065 ME1 digital kilowatt-hour meter EBXA-USB-WIFI Com'X 200 WiFi USB stick
A9M17066 iME1z digital kilowatt-hour meter EBXA-GPRS-SIM Com'X 200 GPRS modem with SIM card
A9M17067 iME1zr digital kilowatt-hour meter EBXA-GPRS Com'X 200 GPRS modem without SIM card
A9MEM2000T iME2000T single-phase kilowatt-hour meter EBXA-ANT-5M Com'X 200 External GPRS antenna
A9MEM2000 iME2000 single-phase kilowatt-hour meter EGX100MG EGX100 Ethernet gateway
A9MEM2010 iME2010 single-phase kilowatt-hour meter EGX300 EGX300 Ethernet server
A9MEM3100 iEM3100 basic energy meter I
A9MEM3110 iEM3110 energy meter with pulse output IE7PRIMARY StruxureWare Power Monitoring Expert Primary server
A9MEM3115 iEM3115 multi-tariff energy meter (DVD, includes all available languages)
A9MEM3135 iEM3135 advanced multi-tariff energy meter & IE7DLS Individual Device Licence for High-End Devices.
electrical parameter plus M-Bus comm port Compatible with all device types.
A9MEM3150 iEM3150 energy meter & electrical parameter IE7DLM Individual Device Licence for Mid-Range Devices.
plus Modbus RS485 comm port Compatible with Mid- and Entry-range devices.
A9MEM3155 iEM3155 advanced multi-tariff energy meter & electrical IE7DLE Individual Device Licence for Entry-Range
parameter plus Modbus RS485 comm port Devices. Compatible with Entry range devices.
A9MEM3165 iEM3165 advanced multi-tariff energy meter & electrical
parameter plus Modbus, BACnet MS/ TP comm port IE7ENGCLIENT Engineering Client Licence (DVD) - Access to
A9MEM3175 iEM3175 advanced multi-tariff energy meter & electrical Management Console, Vista, Designer, Reporter
parameter plus LON TP/FT-10 comm port and Web applications; one licence per user.
A9MEM3200 iEM3200 basic energy meter IE7WEBCLIENT Web Client Licence - Access to Diagrams, Tables,
A9MEM3210 iEM3210 energy meter with pulse output Alarms, Reports, Dashboard; one licence per user.
A9MEM3215 iEM3215 multi-tariff energy meter IE7UNLCLIENT Unlimited Licence for unlimited number of users
(Engineering or Web applications); mandatory for
A9MEM3235 iEM3235 advanced multi-tariff energy meter &
public displays or Internet hosting.
electrical parameter plus M-Bus comm port
A9MEM3250 iEM3250 energy meter & electrical parameter plus RS485 IE7OPCSERVER OPC DA Server for StruxureWare Power Monitoring
comm port
A9MEM3255 iEM3255 advanced multi-tarrif energy meter & electrical
M
parameter plus RS485 comm port M7550 ION7550 energy and power quality meter
A9MEM3265 iEM3265 advanced multi-tariff energy meter & electrical M7330 ION7330 energy and power quality meter
parameter plus Modbus, BACnet MS/ TP comm port M7350 ION7350 energy and power quality meter
A9MEM3275 iEM3275 advanced multi-tariff energy meter & electrical M7550 ION7550 energy and power quality meter
parameter plus LON TP/FT-10 comm port
M7650 ION7650 energy and power quality meter
B
BCPMA042S 42 circuit BCPM 3/4" CT spacing - Advanced M8650A ION8650A energy and power quality meter
BCPMA084S 84 circuit BCPM 3/4" CT spacing - Advanced M8650B ION8650B energy and power quality meter
M8650C ION8650C energy and power quality meter
BCPMA142S 44 circuit BCPM 1" CT spacing - Advanced M8800A ION8800A energy and power quality meter
BCPMA184S 84 circuit BCPM 1" CT spacing - Advanced M8800B ION8800B energy and power quality meter
BCPMB042S 42 circuit BCPM 3/4" CT spacing - Intermediate M8800C ION8800C energy and power quality meter
BCPMB084S 84 circuit BCPM 3/4" CT spacing - Intermediate METSEEM480525 PowerLogic E4800 multi-circuit energy meter
BCPMB142S 42 circuit BCPM 3/4" CT spacing - Intermediate METSEPM3200 PM3200 basic power meter
BCPMB184S 84 circuit BCPM 1" CT spacing - Intermediate METSEPM3210 PM3210 power meter with pulse output
BCPMC042S 42 circuit BCPM 3/4" CT spacing - Basic METSEPM3250 PM3250 power meter with RS485 port
BCPMC084S 84 circuit BCPM 3/4" CT spacing - Basic METSEPM3255 PM3255 power meter with 2 DI, 2 DO, RS485 port
BCPMC142S 42 circuit BCPM 1" CT spacing - Basic METSEPM5100 PM5100 power meter
BCPMC184S 84 circuit BCPM 1" CT spacing - Basic METSEPM5110 PM5110 power meter
BCPMCOVERS Circuit board cover BCPM METSEPM5111 PM5111 power meter
BCPMSCA30S 30 split-core CTs, Advanced BCPM METSEPM5310 PM5310 power meter
BCPMSCA42S 42 split-core CTs, Advanced BCPM METSEPM5320 PM5320 power meter
BCPMSCA60S 60 split-core CTs, Advanced BCPM METSEPM5330 PM5330 power meter
BCPMSCA84S 84 split-core CTs, Advanced BCPM METSEPM5331 PM5331 power meter
bcpmscadpbs Adapter bord, for split core BCPM METSEPM5340 PM5340 power meter
BCPMSCB30S 30 split-core CTs, Intermediate BCPM METSEPM5341 PM5341 power meter
BCPMSCB42S 42 split-core CTs, Intermediate BCPM METSEPM5560 PM5560 power meter
BCPMSCB60S 60 split-core CTs, Intermediate BCPM METSEPM5561 PM5561 power meter
METSEPM5563 PM5563 power meter

14 plsed310031eN
Product selection guide Index of catalogue numbers
(Continued)

Cat. no. Description


P
PLS101111 PowerSCADA Expert 150 Server licences
PLS101112 PowerSCADA Expert 500 Server licences
PLS101113 PowerSCADA Expert 1500 Server licences
PLS101114 PowerSCADA Expert 5000 Server licences
PLS101114-15 PowerSCADA Expert 5000-15000 Server Lic. pt
expansions
PLS101115 PowerSCADA Expert 15000 Server licences
PLS101199 PowerSCADA Expert unlimited Server licences
PLS102010 PowerSCADA Expert 75 Control Client licences
PLS102012 PowerSCADA Expert 500 Control Client licences
PLS102013 PowerSCADA Expert 1500 Control Client licences
PLS102014 PowerSCADA Expert 5000 Control Client licences
PLS102015 PowerSCADA Expert 15000 Control Client licences
PLS102088 PowerSCADA Expert Redundant (CC floating
licence)
PLS102099 PowerSCADA Expert unlimited Control Client
licences
PLS102210 PowerSCADA Expert 75 Web Control licences
PLS102210-11 75 - 150 Serveur licence point expansion
PLS102211 PowerSCADA Expert 150 Web Control licences
PLS10211-12 150 - 500 Serveur licence point expansion
PLS102212 PowerSCADA Expert 500 Web Control licences
PLS102212-13 500 - 1500 Serveur licence point expansion
PLS102213 PowerSCADA Expert 1500 Web Control licences
PLS102213-14 1500 - 5000 Serveur licence point expansion
PLS102214 PowerSCADA Expert 5000 Web Control licences
PLS102214-15 5000 - 15000 Serveur licence point expansion
PLS102215 PowerSCADA Expert 15000 Web Control licences
PLS102215-99 15000 unlimited Serveur licence point expansion
PLS102288 PowerSCADA Expert Redundant (WC floating
licence)
PLS102299 PowerSCADA Expert unlimited Web Control licences
PLS103088 PowerSCADA Expert Redundant (VOC floating
licence)
PLS103099 PowerSCADA Expert View Only Client Licence
PLS103288 PowerSCADA Expert Redundant WVOC (floating
licence)
PLS103299 PowerSCADA Expert Web View Only Client Licence
PM810MG PM810 Power Meter with integrated display
PM810RDMG Meter and remote display kit
PM810UMG PM810 Power Meter without display
PM820MG PM820 Power Meter with integrated display
PM820RDMG Meter and remote display kit
PM820UMG PM820 Power Meter without display
PM850MG PM850 Power Meter with integrated display
PM850RDMG Meter and remote display kit
PM850UMG PM850 Power Meter without display
PM870MG PM870 Power Meter with integrated display
PM870RDMG Meter and remote display kit
PM870UMG PM870 Power Meter without display
PM8ECC PM8ECC module for PM Series 800
PM8M22 PM8M22 module for PM Series 800
PM8M26 PM8M26 module for PM Series 800
PM8M2222 PM8M2222 module for PM Series 800
PM8RDA Remote display and adapter alone
PM8RDMG Remote display and adapter with a 3.55 m cable

There are many more catalogue reference


numbers covering a broad range of accessories,
options, and licences. Please contact your
Schneider Electric representative for further
information and ordering procedure details.

Find more product information at


www.schneider-electric.com

plsed310031eN 15
ART837220 © 2015 - Schneider Electric - All rights reserved

Schneider Electric Industries SAS As standards, specifications and designs change from time to time, please ask for confirmation
of the information given in this publication.
35, rue Joseph Monier
CS 30323 Printed on ecological paper
F - 92506 Rueil-Malmaison Cedex
RCS Nanterre 954 503 439 Layout: Schneider Electric
Capital social 896 313 776 €
Photos: Schneider Electric
http://www.schneider-electric.com
02-2015

Das könnte Ihnen auch gefallen