BASIC FAULT FINDING

1) Input light does not illuminate.


Check that you have a supply of the correct value across the brown and blue
wires. Slide a screwdriver blade across the face of the sensor, the input light
should flicker. If not, contact your supplier. If it does, move the front face nearer
the target and check target size is as specified under "Installation".
2) Input light stays on permanently.
Either increase the gap between the target and the shaft, or between the
SPEEDSWITCH M800
target and the sensor face. UNDERSPEED MONITOR

ELECTRICAL SPECIFICATION

Supply 110V ac or 220V ac 50/60 Hz or 24V ac/dc (specify when ordering).

FM
Fusing Unit should be wired to a supply rated at 5A maximum.
Speed Range 10-3600 PPM. (Pulses Per Minute).
Operating Range 9mm max. (ferrous) 6mm max. (non-ferrous)
Target Ideally ferrous min. 20mm dia. Accessory M500 TG Target Disc
APPROVED
Available.
Start up Delay User Selectable 0-30 Seconds
Calibration Unit is automatically calibrated by the application of a magnet. (Applied
to CAL point on label when shaft is running at speed).
Repeat Accuracy Better than 2%
Enclosure Moulded PC/ABS.
Protection IP67 dust & water tight.
Trip Point Using Single Set Point either 10% or 20% underspeed. Using Dual
Set Points both 10% and 20% underspeed.
Output Relay First Relay Normally Open. Contact Closes at 10% speed. Second
Relay Normally Closed. Opens at -20% speed. Rated 2.5A 240V AC.
WARNING:
LED Display RED LED indicates input pulses. GREEN LED shows output at nominal
O.S.H.A. requires that all exposed rotating shafts
speed and acts as calibration aid. It may flicker during normal operation.
are provided with a full guard. Therefore, this
Weight 185 grams.
device and its target must be equipped with a
Tacho Output Opto-isolated output provided, rated at 30V dc 100mA max, fully
guard.
protected. To feed tachos and other electronic equipment.

GUARANTEE INSTALLATION
INSTRUCTIONS
The equipment is covered by a 12 months guarantee from the date of shipment. Any faults
arising due to faulty materials or workmanship, within the guarantee period, will be corrected
free of charge providing the equipment is returned to us carriage paid.

BRAIME ELEVATOR
COMPONENTS LTD.
4B ELEVATOR SETEM
2 Route de Corbie
TECHNICAL INFORMATION
COMPONENTS LTD.
Hunslet Road, Leeds, 729 Sabrina Drive, East Peoria 80800 Lamotte Warfusée
England. LS10 1JZ Illinois 61611-3578 France
Tel: +44 (0) 113 246 1800 Telephone: 309 -698 -5611 Telephone: 03 22 42 32 26 UNDERSPEED MONITOR - PART Nos. 220V ac M8001V2F
Fax: +44 (0) 113 243 5021 Fax: 309-698-5615 Fax: 03 22 42 37 33
e-mail: elevators@braime.com e-mail: 4b@go4b.com e-mail: setem@setem.fr UNDERSPEED MONITOR - PART NO. 110V ac M8001V1F
Web: www.braime.com Web: www.go4b.com Web: www.braime.com/setem
UNDERSPEED MONITOR - PART NO. 24V dc M8001V4F
644-021B ISS120600 >:M800MAN
GENERAL WIRING
The M800 motion monitor detects slip, low or zero speed on belt and bucket elevator legs, conveyors or The unit connections and typical wiring diagrams are given in figs. 2,3 4 and 5. Note that contacts are
rotating machinery. voltage free and there is no connection between terminal 1 and the relay, until links are installed as
The unit requires no contact with the shaft, is fully solid state, and has a virtually unlimited operating life. required. See figs. 2,3 and 4. Note that the startup is initiated by applying power
The M800 may be used either as a dual trip unit giving an alarm at 10% below set speed and a shutdown
signal at 20% below set speed, or a single trip giving a shutdown signal at 20%. With the addition of an COMMISSIONING & AUTO-CALIBRATION
auxiliary relay, it can also give a shut down signal at 10% (see fig. 4). The M800 is factory calibrated at a set speed of 10 ppm and a start up delay of 5 seconds. For applications
An automatic calibration facility allows the unit to be programmed to give a start up delay of up to 30 requiring a different speed or delay, see initial Setting up Operation. For future re-calibration see
seconds, whilst simultaneously calibrating for nominal speed. Re-Calibration for a Different Setting.
An auxiliary pulse output is provided to feed suitable speed indicators.
INITIAL CALIBRATION
INSTALLATION If the start up delay required is less than 5 seconds (if longer, see re-calibration below).
The inductive sensing device, located in the front of the M800 enclosure is designed to detect a metal target 1) Ensure that all connections are correct.
on a shaft. The target can be a bolt head or similar. 2) Apply power to the M800 and start machinery.
Ideally, the target should be a ferrous metal but non-ferrous metal will detect at a shorter range. Maximum 3) Allow the machine to reach nominal speed and then hold either end of the magnet (supplied) on the CAL
range for a ferrous material is 11/32" (9mm) and for non-ferrous metal is 7/32" (6mm), assuming a 3/4" point on the label for the start up delay required then remove the magnet. The delay can be set by
(19mm) diameter target. Smaller targets may be used but operating distance will be reduced. counting flashes on the output LED while the magnet is on the CAL point. Each flash represents 1
The M800 should be mounted adjacent to the target, ensuring that the distance to the target does not second.
exceed the stated maximum. Typical mounting methods are shown in fig 1. 4) The output LED will flash to 'echo' back the set time and will automatically calibrate to 10% and 20%
When mounted against a solid steel shaft, the target or bolt head should protrude from the shaft about 3/ below speed.
8" (10mm). Otherwise the sensor will not be able to separate the target from the shaft and the red input
light would stay on permanently (instead of flickering) and it would not be possible to calibrate the unit. RE-CALIBRATION FOR A DIFFERENT SETTING
If the unit is to be calibrated to a higher speed and shorter time delay, follow the initial procedure detailed
TACHO OUTPUT above. If the speed is lower or the required delay longer, the M800 may cut out before the machine has
An opto-isolated output is provided, rated at 30V 100mA max. The output is on when the target is detected reached speed, in this case follow the procedure below:-
and off otherwise. This output pulse can be used to feed remote tachos or other electronic products. 5) Hold one end of the magnet on the CAL point.
6) Switch on the M800 and machinery.
Mounting Procedure For Speedswitch M800 Motion Monitor 7) Allow the machinery to reach speed and remove the magnet.
Fasten the Speedswitch to a suitable mounting bracket, with the nose of the switch 8) Wait until the output light stops flashing and then calibrate as detailed under Initial Calibration 3&4.
within the sensing range of the target., as shown below, and then wire up and calibrate
as described in Set-up procedure. Connections

100 KEY
C M a c h in e C o n ta ct o r
B lk = B la ck B lu = B lu e
B 30 60 F ig 1 B lk / B rn B r L (+ )
R ed= Red B rn = B ro w n
10 % S u p p ly A A la rm L a m p
B lk / R e d B l N (-) O r= O ra n g e Ye l= Y e l lo w
P n k = P in k W h = W h it e
RA NG E FO R SE T TING U P B lk / O r
M 8 00
Pnk R A u x illia ry R e la y
+ S e n so r
20 %
B lk /Y e l Wh C N o rm a lly O p e n A u x illia ry
- O utput
40

A = 9m m max for ferr ous target C o n t a c t O n C o n t a c to r

R N o rm a lly C lo s e d C o n t a ct
S t a n d a rd C o n n e ct io n s
A = 6m m for non ferr ous target O n A u x illia ry R e la y

A L in e Fig. 2 L in e Fig. 3 L in e Fig. 4


B
4xM 6 Fix ing Holes B =10 mm m inim um
F us e 5A M ax F us e 5A M ax F us e 5 A M ax C
Stop Stop S t a rt
2 metre
B lk / B rn Br B lk / B rn Br B lk / B rn Br
10% 10% Stop 10%
B lk / R e d Bl B lk / R e d Bl B lk / R e d Bl
M 800 M 800 B lk / O r M 800
B lk / O r Pnk + B lk / O r Pnk P n k+
S t a rt
1/2" NPT Internal T hread S t a rt
20% 20%
+
20%
B lk /Y e l Wh - B lk /Y e l Wh B lk / Ye l W h-
-
Rivet R
Tar get
on Disc
C A C C R
N e u t ra l N e u t ra l N e u t ra l

Examples of Targets Ty p i ca l c o n n e c ti o n s 1 0 % a l a rm , sh u td o w n Ty p i ca l c o n n e c ti o n s , n o a l a r m , s h u td o w n Ty p i ca l c o n n e c ti o n s , n o a l a r m s h u td o w n

a t 2 0 % u n d e rs p e e d a t 2 0 % u n d e rs p e e d a t 1 0 % u n d e rs p e e d
Alternate
Bo lt Tar get Plate
Tar get