bandwidth(M) 20
each channel power(W) 60
PA(db) -3 RB power distribution table - RS class symbol bit is 100 unit value
PB(db) 1 symbol1
symbol2
symbol3
symbol4
symbol5
symbol6
symbol7
subcarrier 1 50.12 50.12 50.12 50.12 50.12 50.12 50.12
subcarrier 2 50.12 50.12 50.12 50.12 50.12 50.12 50.12
subcarrier 3 0 50.12 50.12 50.12 0 50.12 50.12
calculate buffer subcarrier 4 50.12 50.12 50.12 50.12 50.12 50.12 50.12
RS power(dbm) 20 subcarrier 5 50.12 50.12 50.12 50.12 50.12 50.12 50.12
RB num 100 subcarrier 6 100 50.12 50.12 50.12 100 50.12 50.12
RRU power(W) 60 subcarrier 7 50.12 50.12 50.12 50.12 50.12 50.12 50.12
RS power(mw) 100 subcarrier 8 50.12 50.12 50.12 50.12 50.12 50.12 50.12
PA/PRS 0.50118 subcarrier 9 0 50.12 50.12 50.12 0 50.12 50.12
PB/PA 1 subcarrier10 50.12 50.12 50.12 50.12 50.12 50.12 50.12
PA power(mw) 50.118723 subcarrier11 50.12 50.12 50.12 50.12 50.12 50.12 50.12
PB power(mw) 50.118723 subcarrier12 100 50.12 50.12 50.12 100 50.12 50.12
中间计算(影 601 601

output zone
power utilization 100.00% RS occupy rate; 16.63%
RS occupy rate 16.67% PB occupy rate; 33.35%
PA occupy rate 50.12%
PB occupy rate 33.41% PA occupy rate; 50.02%
RS power (db) 20

Confidential Information of Huawei.


08/23/2019 Page1of9
No Spreading without Permission
434280647.xlsx Security Level

RB power distribution
100
bit is 100 unit value 90
symbol7
80
70
60
50
40
30
20
1
r
10 rrie
c a
0ub
s
8
r
ir e
r
b ca
su

l1 l2
bo bo ol3 ol4 l5
m b b l6
sy sym ym m bo bo ol7
s sy y m b
s sym ym
s

CELL ID
MML COMMAND 1 MOD PDSCHCFG: LocalCellId=1, ReferenceSignalPwr=200, Pb=1;
MOD CELLDLPCPDSCHPA: LocalCellId=1, PaPcOff=DB_3_P_A;

Confidential Information of Huawei.


08/23/2019 Page2of9
No Spreading without Permission
434280647.xlsx Security Level

00, Pb=1;
_3_P_A;

Confidential Information of Huawei.


08/23/2019 Page3of9
No Spreading without Permission
434280647.xlsx Security Level

bandwidth Number of RBs PA-1 ant PA-2 ant PA-4 ant PB


1.4M 6 -6 -6 -3 0
3M 14 -4.77 -4.77 -1.77 1
5M 25 -3 -3 0 2
10M 50 -1.77 -1.77 1.23 3
20M 100 0 0 3
1 1 4
2 2 5
3 3 6

Number of antennas
1
2
4
8
test

Confidential Information of Huawei.


08/23/2019 Page4of9
No Spreading without Permission
434280647.xlsx Security Level

EB/EA-- 1 ant EB/EA-- 2 ant EB/EA-- 4 ant PA Value MML Value


1 1.25 1.25 -6 DB_6_P_A
0.8 1 1 -4.77 DB_4DOT77_P_A
0.6 0.75 0.75 -3 DB_3_P_A
0.4 0.5 0.5 -1.77 DB_1DOT77_P_A
0 DB0_P_A
1 DB1_P_A
2 DB2_P_A
3 DB3_P_A
1.23 DB1_DOT23_P_A
4 DB4_P_A
5 DB5_P_A
6 DB6_P_A

Formula 10 * LOG10 (power * 1000 / (number of RBs * 12 * 10 ^ (PA value / 10)))

Confidential Information of Huawei.


08/23/2019 Page5of9
No Spreading without Permission
434280647.xlsx Security Level

DATE Version Number


11/10/2013 V1.0
11/15/2013 V1.1
12/1/2013 V1.2

12/21/2013 V1.3

08/23/2019 Huawei Proprietary - Restricted Distribution Page6of9


434280647.xlsx Security Level

Release Note
Realize the dynamic display of PDSCH 3D graph
Correct the power calculation
The power input mode is changed from single antenna power to total power
Correct the power utilization algorithm, optimize the partial algorithm