8/16/2019 C7.

1 DE200E0/DE220E0 Generator Set GTY00001-UP(SEBP7395 - 11) - Documentation

Shutdown SIS

Previous Screen

Product: GENER ATO R SET


Mode l: C 7.1DE200E GENER ATO R SET GTY
C onfiguration: C 7.1 DE200E0/DE220E0 Ge ne rator Se t GTY00001-UP

Testing and Adjusting


C7.1 Generator Set Engines
Media Number -M0071960-00 Publication Date -01/04/2016 Date Updated -27/04/2016

i04046710

Compression - Test
SMCS - 1215

The cylinder compression test should only be used in order to compare the cylinders of an engine. If one or more
cylinders vary by more than 350 kPa (51 psi), the cylinder and related components may need to be repaired.

A compression test should not be the only method which is used to determine the condition of an engine. Other tests
should also be conducted in order to determine if the adjustment or the replacement of components is required.

Before the performance of the compression test, make sure that the following conditions exist:

The battery is in good condition.

The battery is fully charged.

The starting motor operates correctly.

The valve lash is set correctly.

All glow plugs are removed.

The fuel supply is disconnected.

https://s1.remotelab.space:500/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 1/2
8/16/2019 C7.1 DE200E0/DE220E0 Generator Set GTY00001-UP(SEBP7395 - 11) - Documentation

Illustration 1 g02260098
Typical example

1. Remove the glow plug (1). Refer to Disassembly and Assembly, "Glow Plugs - Remove and Install" for the
correct procedure.

2. Install a suitable gauge for measuring the cylinder compression in the hole for the glow plug.

3. Remove the fuse for the glow plugs.

4. Operate the starting motor in order to turn the engine. Record the maximum pressure which is indicated on the
compression gauge.

5. Repeat Steps 6 and 4 for all cylinders.

6. Install the fuse for the glow plugs.