Gas condensing technology 6
Laboratory equipment 10
Systems for condensing boiler technology 12
System solutions 14
EC radial blowers 18 VG 71 20
VG 100 22
VG 108 24
NRG 118 26
RG 148 28
NRG 137 30
EC radial blowers
RG 175 32
G1G 170 34
G3G 200 36
G3G 250 38
G3G 250 MW 40
G3G 315 42
VG 450 44
46
46 Connectors
Electrical interfaces 48
Gas valves
electronic gas air ratio
control systems G15/G20 F01 58
G32 F01 60
G40 F01 62
control units
Burner control units 64 Commercial range 65
Burner
Residential range 66
Agents 67
Agents
Worldwide
We believe the consistent further development of our highly-efficient GreenTech EC technology provides our customers with the best opportunities
for the future in industrial digitization. With GreenIntelligence, ebm-papst already offers intelligent networked complete solutions that are unique
anywhere in the world today and that secure our customers a decisive advantage.
Six reasons that make us the ideal partner: Closeness to our customers.
ebm-papst has 25 production locations worldwide (including facilities
Our systems expertise. in Germany, China and the USA), together with 49 sales offices,
You want the best solution for every project. The entire ventilation each of which has a dense network of sales representatives. You will
system must thus be considered as a whole. And that’s what we always have a local contact, someone who speaks your language and
do – with motor technology that sets standards, sophisticated knows your market.
electronics and aerodynamic designs – all from a single source and
perfectly matched. Our standard of quality.
Our quality management is uncompromising, at every step in every
Our spirit of invention. process. This is underscored by our certification according to
We are also always able to develop customized solutions for you international standards including DIN EN ISO 9001, TS declaration
with our versatile team of over 600 engineers and technicians. of c onformity and DIN EN ISO 14001.
4
The next level of Green
Sustainability and environmental protection are more than just buzz- GreenIntelligence optimizes processes.
words for us, they are a pivotal part of our company philosophy. Our Today, the greatest economic opportunities for industrial systems are
commitment includes green production, dealing responsibly with in process efficiency. Digital connectivity for all components enables
resources and society, and finished products that use energy effi- better process planning, faster troubleshooting, and optimization
ciently – things for which our globally respected GreenTech label has of their overall interaction. ebm-papst supplies both the physical
stood for many years. components and the smart control systems that are required for this.
GreenIntelligence is the logical next step in the evolution of GreenTech. GreenIntelligence for smart solutions.
In a nutshell, it is everything GreenTech stands for, enhanced by the When it comes to choosing the right drive or fan, product character-
possibilities and opportunities of digital connectivity, the Internet of istics such as energy efficiency and performance figures are no longer
Things and artificial intelligence. For our customers, that means we the only crucial factors; the optimum interaction of all components
bring their applications to a completely new level by adding new value in a process is what matters. Our GreenIntelligence solutions can
that goes far beyond the purely physical capabilities of individual communicate with their environment. They gather and analyze data
fans or drives. Think of remote monitoring, predictive maintenance, and adjust to conditions to ensure the best possible performance.
self-optimizing processes: ebm-papst makes all of these things pos-
sible today with integrated solutions featuring smart connectivity for GreenIntelligence is limitless connectivity.
ventilation and drive engineering applications. Or simply: the next All GreenIntelligence products have full Industry 4.0 capability and
level of Green. can be integrated in any system quickly and easily thanks to
plug & play, minimizing the amount of effort involved in installation
and adjustment for our customers.
GreenIntelligence is self-improving.
In the data it gathers, the system software supplied by ebm-papst
can recognize potential for optimization and, if desired, implement
it automatically – the first step toward artificial intelligence.
5
Gas condensing technology
That's ebm-papst
6
Information
Since creating the world’s first gas blower for condensing technology, we have been the
market leader for efficient components and complete, perfectly matched systems. We
develop blowers, venturis, valves and burner controls together with our customers and
supply everything as a full package. Enjoy the benefits of our well-established and
constantly updated technology combined with unique system expertise.
2 kw
Information
Commercial technology
4 MW
As market and technology leaders, we are constantly endeavoring to For example our checks include examining design influences such
improve our performance and provide our customers with the best as modifications to the gas-air mixing device, the backflow flaps or
Information
possible complete solution. Our engineers and technicians assist our the venturi. All these factors can affect the efficiency, noise level
customers with the development of their application right from the and functionality of a condensing heating system. We take measure-
start to help advance the process of improvement. Before series ments on gas-air composite systems directly in the heating unit
launch we conduct extensive tests to ensure compliance with legal to ensure ideal matching of the individual components and motor
requirements and customer specifications. We have a wide range of performances. This is accompanied by flow simulation with direct
measuring equipment at our disposal for this purpose. incorporation of the results obtained.
Information
About 150 different endurance For simulation of transpor-
tests with over 700 specimens tation and operation with
in progress different vibration profiles
Sound measurement laboratory:
Precise sound power and gas
measurement technology with
incorporation of real conditions
Additional equipment:
– 3D microscope
– 3D plotter
Gas valve test stands:
For gas valves with pneumatic and
electronic modulation
An optimum gas-air mixing ratio is crucial to the energy yield realized modulation level are determined among others by the minimum and
during combustion. The mixing ratio needs to be exactly adjusted maximum output of the premixing blower. This means its compo-
Information
to the heating value of the gases being used (e.g. natural gas, LPG nents need to be perfectly matched. That’s why we offer complete
or biogas). An additional challenge is the flexibility of heat output. heating systems including gas blowers, venturis, gas valves and
The greater the modulation range of a heating system, the better burner control units from a single source.
its heating output can be adjusted to actual needs. The limits of the
Ideally suited for use in electronic or pneumatic gas air ratio control systems
gas
flame detection
air gas air
mixture
burner
LIN
electronic
control
LIN LINbus BCU info flame detection
communication
pumps
control pressure
gas
burner
Information
State-of-the-art blower
technology for modulating
operation with low noise
and a long service life
Venturi:
The pressure generated by
the venturi effect provides an
optimum mixture of gas and
air in the pneumatic gas-air
ratio control
Gas valve:
The component required for the
reliable supply of gas has
a particularly compact design
All heating technology components must be perfectly harmonized in Our multi-venturi solutions provide you with a wide variety of motor
order to achieve optimum performance and efficiency. This is why performances and options for assigning our systems to your devices.
Information
we offer complete heating systems, including gas blower, venturi This gives you the benefit of flexible integration into compact spaces.
and gas valve, from a single source.
We supply our systems as completely tested, harmonized units with
A key benefit of our gas-air composite systems is their optimal optimized interfaces to minimize your effort.
mixing ratio with simultaneously high modulation ranges. To achieve
this high level of efficiency, we provide different venturi elements for
multi-venturis, depending on the heat output range.
Mounting positions
With horizontal shaft or vertical shaft with motor positioned at top
Illustration examples
System solutions
[kW] [W]
2 – 15
HS0077E1PXXS 5 – 28 G15 E01 62
(NRV 77)
7 – 35
3 – 23
HS0118E1PXXS 5 – 28 G15 E01 70
(NRV 118)
7 – 42
10 – 65 G15 D01
HS0148D1PXXS 200
(NRV 148)
20 – 110 G20 D01
15 – 90 200
HS0137D1PXXS G20 D01
(NRV 137)
24 – 145 300
140 160
100 120
60 80
20 40
kW
Heat output range depending on type of gas concerned and system conditions.
Nominal data
2 – 15 5573433000
HS0077E1PXXS 5 – 28 5573433010
157
mm 7 – 35 5573433020
204 mm
Sample on request
* Approximate figures. Heat output range depending on type of gas concerned
and system conditions.
Nominal data
3 – 23 5573432010
HS0118E1PXXS 5 – 28 5573432020
163
mm 7 – 42 5573432030
224 mm
Sample on request
* Approximate figures. Heat output range depending on type of gas concerned
and system conditions.
Nominal data
10 – 65 5571450000
HS0148D1PXXS
20 – 110 5572450000
259
mm
* Approximate figures. Heat output range depending on type of gas concerned
256 mm
Sample on request and system conditions.
Nominal data
15 – 90 5572410000
HS0137D1PXXS
24 – 145 5572410020
240 * Approximate figures. Heat output range depending on type of gas concerned
mm
271 mm and system conditions.
Sample on request
Modern gas-fired modulated condensing units have to be supplied solutions for this application area. However, the special properties
with the optimum volume and mixture of air and fuel in all operating of these blowers make them suitable for many other applications as
modes and ambient conditions. They require adjustable blowers well. Examples include gas-powered cooking appliances for the food
with steep pressure/air flow characteristic curves and high maximum service industry or gas-powered deep fryers for commercial use.
pressures. ebm-papst played a significant role in developing
EC blowers for this purpose and now offers the widest range of
Heat load in kW
... 4000
2000
EC radial blowers
1500 1750
1000 1250
500 750
kW 250
Heat output range depending on type of gas concerned and system conditions.
Commutation electronics:
– Integrated into the blower unit and Housing:
perfectly harmonized with the motor – Made of die-cast aluminum
– Integrated blockage switch-off and – (respectively cast aluminium/sheet steel)
overheating protection as per EN 60335 – Required density thanks to special seal
– Various standard interfaces available for housing halves and drive shaft conduit
for the respective burner control – Outlet flange adjustable to many designs
– Optimized in accordance with EMC
emissions and pollution Impellers:
– For type VG, NRG und RG
blowers of pentane-resistant
plastic: dynamically fine
balanced
– For the G1G 170,
Speed controls: G3G 200, G3G 250,
– Adjustment required in individual cases G3G 250MW, G3G 315 and
EC radial blowers
– Controlled via PWM signal VG 450 models made of
– 0–10 V input optional sheet aluminum
– Bus communication optional
Bearings:
– Maintenance-free ball bearings
covered on both sides for long
service life and smooth operation
– Use of lubricants suited for the
particular application
Protection class:
Protection class I
Degree of protection:
Degree of protection IP20 with
cover, depending on the Installati-
on position
Mounting positions:
– With horizontal shaft or vertical shaft with motor
Speed output:
positioned at top
– With Hall IC signal output; in case of motors for line voltage
– For vibration-cushioned motor installation, the
operation, speed signal output is galvanically isolated
motor’s weight is additionally supported by a
– VG, NRG and RG blowers, each with two pulses per revolution
flexible element.
– G1G and G3G blowers, each with three pulses per revolution
– G3G 250 MW blower with four pulses per revolution
– G3G 315 and VG 450 blower with five pulses per revolution
Material/surface
■■ Housing: Die-cast aluminium/sheet steel
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multiventuri on request
Electrical data
■■ Protection class I
EC radial blowers
A
2000
8
1500
6
1000
4
500
2
0 10 20 30 40 50 cfm
pfs
qv 20 40 60 80 m3/h
A
W
60
45
30
15
0 10 20 30 40 50 cfm
pw
qv 20 40 60 80 m3/h
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 220/240 V AC, 50/60 Hz
A 14000 65 60 60
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
81±1
39.25
Y 5.55 (2x)
Ø83
Ø71
45.3
24.3
Z Ø5.55 (2x)
12.6
45 29.2
172
° 45°
54
Y 6x
60
Z (=3
60
°)
Ø80
25
5.7+0.2
-1.0
81.2 M6 (6x)
164
②
①
Material/surface
■■ Housing: Die-cast aluminium/sheet steel
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multiventuri on request
Electrical data
■■ Protection class I
EC radial blowers
A
2000
8.0
1500
6.0
1000
4.0
500
2.0
0 10 20 30 40 50 60 cfm
Pfs
qV 20 40 60 80 100 m3/h
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 220/240 V AC, 50/60 Hz
A 10000 90 60 60
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
81±1
39.25
Y
5.55 (2x)
Ø71
51.6
Ø83
25.2
Z
Ø5.55 (2x)
12.6
172
6x
Y Z 60
° (=
36
0°
)
Ø80
+0.2
25
5.7 -1.0
81.2 M6 (6x)
164 ②
①
Material/surface
■■ Housing: Die-cast aluminium/sheet steel
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multiventuri on request
Electrical data
■■ Protection class I
EC radial blowers
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 220/240 V AC, 50/60 Hz
A 10000 135 60 60
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
103.6 ±1
45.1
Y
61.1
Ø83
Ø71
30.9
Z Ø5.55 (4x)
15.6
192.5
45° 33.9
45°
66
Y Z
3x
12
0°
(=3
60
Ø100
)°
28.4
3x
6.5+0.2
12
-1.0
89
0°
M6 (3x)
(=3
③
183.4
60
①
°)
M4 (3x)
②
① Groove suitable for round sealing ring 70 x 3
② 6.5 deep
③ 7.5 deep
Material/surface
■■ Housing: Aluminium
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multi-venturi available
Electrical data
■■ Protection class I
EC radial blowers
A
3000
12
2000
8
1000
4
0 10 20 30 40 50 cfm
10 20 30 40 50 60 70 80 90
W
100
90
75 A
60
45
30 B
15
0 10 20 30 40 50 cfm
w
10 20 30 40 50 60 70 80 90
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 230 V AC, 50 Hz
A 10000 70 60 60 1)
Nominal voltage 115 V AC, 60 Hz
B 10000 61 60 60 1)
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
max. 93
ca. 9°
ca. 39.9
42° Y Ø5.55 (4x)
26
50.3
Ø83
Ø71
Z
16.4
28.9
174.3
45°
45°
57.8
6x 6
° (=3 0
Z 6
60 0°)
②
°
Y M4 (3x)
30°
Ø100
Ø80
5.5 +0.2
-1.0
19.3
84.5
162.9
M6 (6x)
① ②
Material/surface
■■ Housing: Aluminium
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multi-venturi available
Electrical data
■■ Protection class I
EC radial blowers
5000
20
A
4000
16
3000
12
2000 B
8
1000
4
200
A
150
100
B
50
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 230 V AC, 50/60 Hz
A 9000 200 60 60
Nominal voltage 120 V AC, 60 Hz
B 8200 130 60 60
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
max. 143
41.2
Y Ø5.55 (4x)
Ø83
Ø71
56
Z
16.3
197.6
Z ② 3x
12
0
Y 12 ° (=
0° 36
0°
)
Ø100
5.9+0.2
-1.0 22
90.4
184.3
120
①
°
3x
120
° (=
360 Ø3.7 (3x)
°)
③
Material/surface
■■ Housing: Aluminium
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multi-venturi available
Electrical data
■■ Protection class I
EC radial blowers
3000
12
2000 B
8
1000 A
4
B
250
200
A
150
100
50
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 230 V AC, 50/60 Hz
A 8500 220 60 60
Nominal voltage 120 V AC, 60 Hz
B 8500 250 60 60
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
max. 150
52.8
Y Ø5.55 (4x)
Ø83
Ø71
55
27.7
Z
Ø89.6
21
45° 42 45°
210.1
①
75.2
3x
12
0°
(=3
Z 60
°)
Y
120
°
Ø100
5.9+0.2
-1.0
30.7
86.3
186.9 3x 12
12 0° M4 (3x)
②
0°
(=3
60 M6 (3x)
°)
③
Material/surface
■■ Housing: Aluminium
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers
4000
16
3000
A
12
2000
8
B
1000
4
A
250
200
B
150
100
50
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 230 V AC, 50/60 Hz
A 6250 270 60 60
Nominal voltage 120 V AC, 60 Hz
B 6250 240 60 60
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
max. 161
63.1
Y
Ø9 (4x)
R29.4
110
59.7
56
Z
24
67.2
255
90
92.15
126
12x
Z 3
30° 0° (=36
Y 0°)
Ø140
7+0.2
-1.0 36.5
114.3
231.14
①
M8 (12x)
②
Material/surface
■■ Housing: Aluminium
■■ Impeller: Sheet aluminium
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers
3000
12
B
2000
8
1000
4
400
A
300
200
B
100
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 1~230 V AC, 50/60 Hz
A 7200 420 55 80
Nominal voltage 1~115 V AC, 50/60 Hz
B 7200 360 55 80
Subject to change.
EC radial blower
Curve
EC radial blowers
B Technical drawing Dimensions in mm
177 ② 6x
60
257 44 M8 (6x) ° (=
36
0°
)
Ø140
280
101
165
60
95
98
Ø9
①
6.5
120
123
140
Material/surface
■■ Housing: Aluminium
■■ Impeller: Sheet aluminium
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers
A
3000
12
B
2000
8
1000
4
750
750
A
500
500
B
250
250
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 1~230 V AC, 50/60 Hz
A 6100 890 50 50
Nominal voltage 1~115 V AC, 50/60 Hz
B 5700 800 60 60
Subject to change.
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
237 ② 6x
60
323 56 M8 (6x) ° (=
36
0°
)
Ø220
355
124
90
113
117
Ø9
9
①
140
168
180
Material/surface
■■ Housing: Aluminium
■■ Impeller: Metall
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers
B
3000
12
A
2000
8
1000
4
1000
800
B
600
400
A
200
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 1~230 V AC, 50/60 Hz
A 5200 1150 60 60
Nominal voltage 1~115 V AC, 50/60 Hz
B 5200 1200 60 60
Subject to change.
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
121
250
② 6x
444 66 M8 (6x) 60
° (=
36
0°
)
Ø220
474
171
165
169
92
11 180
①
Ø9
205 220
Material/surface
■■ Housing: Aluminium
■■ Impeller: Sheet aluminium
■■ Motor housing: Metall
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers
6000
24
4000
16
2000
8
A
W
2000
1500
1000
500
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 3~380 – 480 V AC, 50/60 Hz
A 6400 2500 50 50
Subject to change.
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
377 ±2
120.5 Ø220
M20x1.5 (3x)
Z
①
Ø120
Ø260
459 ±1
171
265
°
6x60
169.4
66.3
Z
②
M8 (6x)
③
12 +1
Ø9 (4x)
8 92
204.5 180
435 ±1 220
Ø178.6
5
2.9
Material/surface
■■ Housing: Aluminium
■■ Impeller: Sheet aluminium
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover
■■ Installation position: Any
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers
6000
24
4000
16
2000
8
A
W
6000
4000
2000
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 3~380 – 480 V AC, 50/60 Hz
A 6000 8000 60 60
Subject to change.
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
X
10.3
Ø154.6
95
549.5
131.9
190
4
29
200.3
Ø
207.3
266
300
Ø 11(4x) 134.2
216
250
Material/surface
■
■■ Housing:
■ Gehäuse:Die-cast
Aluminiumaluminium
■ ■ Impeller: Sheet
■■ Impeller: plasticaluminium
■
■■■ Motor
: casing: Cast aluminium
■■ Electronics box: Cast aluminium
Mechanical
Mechanical data
data
■
■■ :Protection
■ IP20 mit Abdeckhaube, abhängig von der
class blower: IP00
■■ Protection
: mit waagerechter Welle oder
class electronics: bei senkrechter
IP54
Welle mit Motorlage
Protection oben
class motor: IP20
■■ Installation
Mounting: free ball bearings
position: Any
■■ Mounting: Ball bearings
Electrical
Electrical data:
data
■
■■ Protection class
■ Protection class II
EC radial blowers
A
30
6000
25
20
4000
15
10
2000
5
A
W
12000
10000
8000
6000
4000
2000
Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.
temp. of medium
input power Ped
Max. speed n
Max. perm.
Max. perm.
Curve
Max.
min⁻¹ W °C °C
Nominal voltage 3~380-480 V AC, 50/60 Hz
A 4250 14000 401) 50
1) short-term 60
Subject to change.
EC radial blower
Curve
EC radial blowers
A Technical drawing Dimensions in mm
863.4
462.4
474
194.2
Z
5.5
2.7
20.5
Z
Ø182
106
786
276.5
05
Ø3
50
268.6
400
Ø3
279
356
①
Ø13 (8x)
163.5
282
326
① Seal groove
G3G 250 MW
NRG 118
NRG 137
G3G 200
G3G 250
G1G 170
G3G 315
RG 148
VG 108
VG 450
VG 100
RG 175
VG 71
Connector
1 Mains connector X x x x x x x x
3 Interface connector W x x
4 Interface connector W x x x x x x
5 Interface connector W x x
EC radial blowers
6 Interface connector W
Interface 04600451… 31 31 31 04 04 04 04 38 39 39 64 61 63
1 Mains connector X
3-pin pin-connector with coding type 0A according to RAST 5
in 90° angled / horizontal design
with locking feature on top or down for locking device suitable for
mating connector according to RAST 5
with coding type 0A as e. g.
CoHaMo YY-A5002-H03-K01 or Lumberg 3623 03 K01
① ② ③
Part number for mating connector:
2431045025
① Power supply AC
② Protective earth
③ Power supply AC
2 Mains connector X
3-pin pin-connector according RAST 6.35
in 90° angled / horizontal design
suitable for mating connector according to RAST 6.35
e. g. Tyco Universal MATE-N-LOK
Order number: 1586847-1 and 3 x socket 926882-1 ① ② ③
Part number for mating connector:
Connector shell 2430945012; Crimp socket 2430745002/3
① Protective earth
② Power supply AC
③ Power supply AC
4 Interface connector W
5-pin pin-connector according RAST 4.2
in 90° angled / horizontal design
suitable for mating connector
e. g. Stocko STO-FIT, CoHaMo
① ② ③ ④ ⑤
Order number Stocko:
EH 705-005-004-960 and 5 x socket RBB 8230.120
EC radial blowers
① Power supply - (GND)
Order number CoHaMo: ② PWM Input
YY-5700-H05AS-GW ③ NC
5 Interface connector W
5-pin pin-connector according RAST 4.2
in 90° angled / horizontal design
suitable for mating connector
e. g. Stocko STO-FIT, CoHaMo
① ② ③ ④ ⑤
Order number Stocko:
EH 705-005-004-960 and 5 x socket RBB 8230.120
① Power supply - (GND)
Order number CoHaMo: ② PWM Input
YY-5700-H05AS-GW ③ Input 0-10 V DC Control
6 Interface connector W
5-pin pin-connector according RAST 4.2
in 90° angled / horizontal design
suitable for mating connector
e. g. Stocko STO-FIT, CoHaMo
① ② ③ ④ ⑤
Order number Stocko:
EH 705-005-004-960 and 5 x socket RBB 8230.120
① Power supply - (GND)
Order number CoHaMo: ② PWM Input
YY-5700-H05AS-GW ③ Input 0-10V DC Control
18-43VDC
1
15K
1K
HS
12V
22K 2
EC radial blowers
10nF
4K7
7.5V
22K
12K
PWM
3/4 - Safe start PWM >20%
1K 12K
- Hallsignal: 2 pulses per revolution
- PWM "HIGH" = blower ON
- PWM "LOW" = blower OFF
GND
4/5
1 +18..43VDC
15K
Vcc
2 Hallsignal
2 pulses per revolution 1K
Hall Signal
12V
1K
3 N.C.
12K
6K8
5V1
PWM-Signal
GND
5 GND
1 UB +24 - 45VDC/15mA
UB ripple ±3.5%
3 D.N.C.
EC radial blowers
12K
4 PWM 2 - 6kHz 1 3
12K input signal - square pulse 1K 6K8 4
2
PWM-Low ->fan off
PWM-High -> fan on
input open -> max. speed
5 GND
start-up -> PWM > 25%
ST2
+15V
+16...45VDC
1 max. ripple +/-3.5%
counter
12K
tacho output
loop controller 3 pulses per revolution 1
2 3
1K 4 2
alarm device
+15V
12V
RPM monitor
47K
3
12K
10K
2 4
PWM 1-6 kHz 10K PWM
4
12K input signal - square pulse PWM
PWM-Low - fan off
PWM-High - fan on
20K
15V
Start -> PWM > 10% Start -> PWM > 10% 10V -> n=max
1V -> n=min
n=min -> PWM > 7% n=min -> PWM > 7%
> 0.6V -> Start
Stop -> PWM = 0% Stop -> PWM = 0% < 0.1V -> Stop ST2
Uin 1 +18...43VDC
counter
15K
loop controller
2 tacho output 1K
alarm device
12V
5 pulses per revolution
RPM monitor
3 N.C.
+20V
12k
EC radial blowers
18K
PWM 1-6 kHz
PWM
12k 4
PWM input signal - square pulse 0-5V
1K
PWM-Low - fan off DC
PWM-High - fan on
input open -> max. speed 12K
15V
5 GND
GND
speed control
Gasmodule - interface RSA
6 RSA
galvanic isolation
RSB
7 RSB connection via terminal block
recommended wire size 0.5 - 1mm2
Start -> PWM > 12%
n=min -> PWM > 10%
speed control
Stop-> PWM < 8% Modbus ST2
Uin 1 +18...43VDC
no simultaneous usage with PWM
counter
15K
loop
controller
interface recommended!
2 tacho output 1K
alarm device 5 pulses per resolution
12V
RPM
monitor 0-10V
DC
3 speed control 0-10V * 47K 0-5V
+20V DC
12k
47K
18K
15V
RSA
6 RSA
galvanic isolation
RSB +10V
7 RSB
UOut
8 UOut 10VDC
speed control speed speed
Gasmodule - control control voltage output
interface 0V - 10V Modbus
10V -> n=max connection via terminal block
Start -> PWM > 10%
n=min -> PWM > 8% 2V -> n=min 10VDC OUTPUT
>1.6V -> Start recommended wire size 0.5 - 1mm²
Stop -> PWM < 5% <1.0V -> Stop ST2
NO NO
2A / 250VAC / AC1
Alarm Relay
COM COM
NC NC
ST2
Uin +16...45V
RSA RSA RSA
EC radial blowers
RSB 24V
RSB RSB
68K
12k
15V
max. speed
7V
UOut
+10V +10V
GND GND
GND
4K7
15V
12K
no simultaneous usage with 0-10V interface
loop controller
TACHO TACHO 820
alarm device
RPM monitor
HALL
UOut
12V
+20V +20V
galvanic isolation
0V
GND GND
TACHO
RSB PWM
+10V +20V
GND GND
Gasmodule - interface
RSA
0V - 10V Modbus
Start -> PWM > 10% 10V -> n=max 10VDC 20VDC 4 pulses per resolution ST3 ST2
2V -> n=min OUTPUT OUTPUT
n=min -> PWM > 7% >1.6V -> Start (±10%) (±20%) 12VDC(±10%) / max.10mA /
Stop -> PWM > 5% <1.0V -> Stop max.10mA max.50mA Impedace 1k ST3
customer circuit interface ebm-papst circuit
* for use of 0-10V interface, bridge PWM to GND
Our gas valves are mainly used in condensing unit The offset (zero point shift) can be configured at the
applications for domestic heating technology in the servo controller. At the same time, the desired gas
low-to-medium output range. They ensure precise quantity is adjusted using an integrated flow control
air-gas ratio adjustment. element. Depending on the design, reference pressure
can be connected to the servo controller if required.
The G20 D01 and G15/G20 E01 gas valves are suitable
for condensing units with pneumatic composite The G15/G20 F01,G32 F01 and G40 F01 gas valves are
controls. Regardless of the suction pressure generated suitable for condensing units with electronic composite
by the premix blower, these gas valves always keep the controls. Regardless of gas quality and any pressure
offset pressure at zero and compensate for pressure fluctuations in the supply network, these gas valves
fluctuations in the supply network as well. regulate the constant air-gas ratio without relying on
mechanical gas valve settings.
Gas valves
Mounting position
Solenoid at any position between vertical and horizontal
– but not upside down
Gas valves
Additional notes
– Work on the gas valve may be performed by authorised
specialists only.
– Please be sure to observe the corresponding installation instructions.
– Corresponding documents with safety instructions are
available upon request or on the Internet.
Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
65 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature: 0°C to 60°C
■■ Permitted storage temperature: -25°C to 70°C
■■ Offset correction: +/- 20 Pa
■■ Input (gas connection):
External thread G3/4 or G1/2 (EN ISO 228) or
Mehr at
More unter www.ebmpapst.com
4 x M4-mounting holes (optional)
■■ Output:
ebm-papst proprietary quick release
■■ Safety valve:
Coaxial design: Valve class B/C as per EN161
Electrical data
■■ Designed for protection class I
Capacity curve – GXXE01-BCXCS ■■ Electrical connection:
Connector shell with 4.20mm grid
100
80
Gas valves
60
50 Recommended operating range
40
30
∆p [mbar]
20
10
8
6
5
4
2
Conditions
Conditions: +15°C/
+ ° C / 59°F,
°F, pp= 1013mbar
= mbar
Nominal diameter
Max. input power
signal pressure
Rated voltage
shutoff valves
inlet pressure
Automatic
Maximum
Minimum
Flow rate
Opening
(EN161)
Type
V VA mbar m³/h Pa s
Nominal data
230 RAC 9.8 DN15/20 65 3.4 Class B/C -40 <1
120 RAC 9.8 DN15/20 65 3.4 Class B/C -40 <1
GXXE01-BCXCS 24 RAC 9.8 DN15/20 65 3.4 Class B/C -40 <1
24 DC 9.8 DN15/20 65 3.4 Class B/C -40 <1
22 DC 11.9 DN15/20 65 3.4 Class B/C -40 <1
Subject to change.
Gas valve
Type Weight
kg
GXXE01-BCXCS 0.57
Ø31
Ø9
103.8
Gas valves
34
Ø54.5
Ø18
30.5
5.5
80 33.5
46 56
105.5
Ø5 50
.1 14.5
(2
④
x)
①
29
14.5
5.5
②
⑤
③
⑥
7.5 14
① Electrical connection 19
② Solenoid coil
③ Pressure test nipple P1
④ Pressure regulator offset adjustment
⑤ Pressure test nipple P2
⑥ Main flow throttle
Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
65 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature: 0°C to 60°C
■■ Permitted storage temperature: -25°C to 70°C
■■ Offset correction: +/- 20 Pa
■■ Input (gas connection):
4 x M5-mounting holes
More at www.ebmpapst.com
(hole spacing 36 mm)
■■ Output:
4 x M5-mounting holes
(hole spacing 36 mm)
■■ Safety valve: Valve class B/B as per EN161
Electrical data
■■ Designed for protection class I
Capacity curve – G20D01-BBXCS ■■ Electrical connection:
Connector shell with 5.08 mm grid
100
80
Gas valves
60
50 Recommended operating
recommended operating range range
40
30
20
∆p [mbar]
∆
10
8
6
5
4
2
Bedingungen
Conditions + 15°C,
+15°C/ 59°F,1013 mbar, trocken
p= 1013mbar, dry
Nominal diameter
Max. input power
signal pressure
Rated voltage
shutoff valves
inlet pressure
Automatic
Maximum
Minimum
Flow rate
Opening
(EN161)
Type
V VA mbar m³/h Pa s
Nominal data
230 RAC 2 x 12.5 DN20 65 5.3 Class B/B -40 <1
120 RAC 2 x 12.5 DN20 65 5.3 Class B/B -40 <1
G20D01-BBXCS
24 RAC 2 x 12.5 DN20 65 5.3 Class B/B -40 <1
24 DC 2 x 12.5 DN20 65 5.3 Class B/B -40 <1
Subject to change.
Gas valve
Type Weight
kg
G20D01-BBXCS 1.3
59
Ø9
111.5
Gas valves
28
Ø54.5
36.5
40.5 41.8
105 83.6
57
① ③
②
⑥ ④
⑦ ⑤
Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
60 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature:
-15°C to 70°C
■■ Permitted storage temperature:
-25°C to 70°C
■■ Input (gas connection):
More at www.ebmpapst.com
External thread G3/4 oder G1/2 (EN ISO 228)
■■ Output:
ebm-papst proprietary quick release
■■ Safety valves:
Coaxial design: Valve class B/C as per EN161
Electrical data
■■ Designed for protection class I
Capacity curve – GXXF01-BCXCS ■■ Electrical connection:
Connector shell with 4.20mm grid
100
Gas valves
10
F01 - 8 mm
F01 - 12 mm
0,01 0,1 1 10
V° n [m3/h] Luft / Air
Nominal diameter
nominal diameter
nominal diameter
Max. input power
(at Δp = 5mbar)
Stepper motor
Stepper motor
Rated voltage
shutoff valves
inlet pressure
module with
module with
Automatic
Maximum
Flow rate
Flow rate
Opening
(EN161)
12 mm
8 mm
Type
Subject to change.
Gas valve
Type Weight
kg
GXXF01-BCXCS 0.47
105.5 62.81
88.7
24.8
21.5 20.8
Gas valves
Ø18
24.1
100
67.75
32.5 11.5
⑤ ①
②
29
③
25
④
① Electrical connection safety valve
② Pressure test nipple
③ G 3/4" or G1/2" ISO 228-1
④ Solenoid coil
⑤ Electrical connection stepper motor
Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
I + II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
60 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature:
-15°C to 60°C
■■ Permitted storage temperature:
-25°C to 70°C
■■ Input (gas connection):
More at www.ebmpapst.com
external thread G 1 1/4 (EN ISO 228)
■■ Output: Flange connection 4 x mounting holes
for self-tapping screw (nominal diameter
5 mm); hole spacing 52.33 mm
■■ Safety valves:
Coaxial design: Valve class B/C in accordance
with EN161
■■ Interface to mechanical pressure monitor port:
Capacity curve – G32F01-CBXCS Inlet pressure; central chamber pressure
■■ Pressure test nipple: Inlet and outlet pressure
100
Electrical data
■■ Designed for protection class I
Gas valves
Recommended
recommended operating range
operating range ■■ Electrical connection:
Safety module: suitable for connector housing
with pitch 4.20mm (e.g., Stocko STO-FIT
System, EH 705-103; Würth series
∆p [mbar]
Conditions Bedingungen:
+15°C/ 59°F, 15° C,p= 1013mbar
p=1013 mbar
1
0,1 1 10 100
V° n [m3/h] Luft / Air
Nominal diameter
Max. input power
shutoff valves
inlet pressure
Automatic
Maximum
Flow rate
Opening
(EN161)
Type
V VA mbar m³/h s
Nominal data
230 RAC 17 DN32 60 9.2 Class C/B <1
G32F01-CBXCS 120 RAC 17 DN32 60 9.2 Class C/B <1
24 DC 17 DN32 60 9.2 Class C/B <1
Subject to change.
Gas valve
Type Weight
kg
G32F01-CBXCS 1.55
137.5
61.5 15
20
Gas valves
115
65
35
65 176
① ②
③ ⑤ ④ ③
① 1 1/4" B ISO 228-1
② Electrical connection safety valve
③ Pressure test nipple
④ Electrical connection control valve
⑤ Solenoid coil
Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
I + II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
60 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature:
-15°C to 60°C
■■ Permitted storage temperature:
-25°C to 70°C
■■ Input (gas connection):
Mehr at
More unter www.ebmpapst.com
Flange connection 4 x mounting holes for
self-tapping screw (nominal diameter 6 mm);
hole spacing 52.33 mm. Input flange 1 ½”
optional
■■ Output: Flange connection 4 x mounting holes
for self-tapping screw (nominal diameter
6 mm); hole spacing 52.33 mm
■■ Safety valve:
Capacity curve – G40F01-BBXCS Coaxial design: External thread B/B as per
EN161
100 ■■ Interface to mechanical pressure monitor port:
Inlet pressure; central chamber pressure for
VPS (optional)
Gas valves
Recommended operating
recommended operating range range ■■ Pressure test nipple:
Inlet and outlet pressure
Electrical data
■■ Designed for protection class I
∆p [mbar]
∆
■■ Electrical connection:
10
Suitable for connector housing with pitch
4.20mm (e.g., Stocko STO-FIT System,
EH 705-103; Würth WR-MPC4 series,
item no. 649 003 013 322)
■■ Stepper motor module:
Connector housing Stocko-Grid MH790-06-001
Conditions +15°C/1559°F,
Bedingungen: p= 1013mbar
° C, p=1013 mbar
1
0,1 1 10 100
V° n [m3/h] Luft / Air
Nominal diameter
Max. input power
shutoff valves
inlet pressure
Automatic
Maximum
Flow rate
Opening
(EN161)
Type
V VA mbar m³/h s
Nominal data
230 RAC 22 DN40 60 15.5 Class B/B <1
G40F01-BBXCS 120 RAC 22 DN40 60 15.5 Class B/B <1
24 DC 22 DN40 60 15.5 Class B/B <1
Subject to change.
Gas valve
Type Weight
kg
G40F01-BBXCS 1.97
180.5
133
50.5
15
14
Gas valves
126
72
38.6
② ④ ③ ②
① Electrical connection safety valve
② Pressure test nipple
③ Electrical connection control valve
④ Solenoid coil
User Interface
– Touch screen: communication with boiler control via Modbus
– Ethernet connection to web server
– Graphical LCD interface for boiler status,
operation and configuration
– Password-protected user levels
– Includes diagnostics software and a smart app for remote control
control units
Burner
User Interface
– On-board HMI: Reset button and status LED
– Advanced external display option
Diagnostics software
Cascade operation
User interface
Power supply
Touch screen
Dimensions
Smart app
Ethernet
Modbus
AL-BUS
control
V AC mm
Packages
Commercial Plus 120/230 212×152×49 8 boilers × 8 modules Y 900PB Display Y Y Y Y Y
Commercial 120/230 212×152×49 max. 16 boilers N 900PB Display Y Y optional Y Y
Residential Plus 120/230 212×152×49 settings only N 900LB Display Y N N Y Y
Managing boiler
900PB Display
Dependent boiler 1
Dependent boiler 7
Diagnostics software
Dimensions control
On-board HMI
User interface
Power supply
Smart app
Modbus
AL-BUS
V AC mm
Packages
Tankless Water Heater 120/230 203×114×50 N 900LB Display Y N Y Y
Water Heater 120/230 203×114×50 N 900LB Display Y N Y Y
Residential Combi Boiler 120/230 203×114×50 N 900LB Display Y N Y Y
Smart Burner 120/230 203×114×50 Y Y Y Y Y
control units
Burner
900LB Display
Canada
ebm-papst Canada Inc.
419 King Street West, Suite 603A
Oshawa, ON, L1J2K5
CANADA
Phone +1 905 420-3533
Fax +1 905 420-3772
sales@ca.ebmpapst.com
www.ebmpapst.ca
Mexico
ebm Industrial S. de R.L. de C.V.
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
Mexico 05120, D.F.
MEXICO
Phone +52 55 3300-5144
Fax +52 55 3300-5243
sales@mx.ebmpapst.com Agents
www.ebmpapst.com.mx
Oceania
Australia
ebm-papst A&NZ Pty Ltd.
10 Oxford Road
Laverton North, Victoria, 3026
AUSTRALIA
Phone +61 3 9360-6400
Fax +61 3 9360-6464
sales@ebmpapst.com.au
www.ebmpapst.com.au
New Zealand
ebm-papst A&NZ Pty Ltd.
61 Hugo Johnston Drive, Unit H
Penrose 1061, Auckland
NEW ZEALAND
PO Box 112278,
Penrose 1642, Auckland
Phone +64 9 525-0245
Fax +64 9 525-0246
sales@ebmpapst.com.au
www.ebmpapst.com.au
Agents
fan agent compact fan agent motor specialist motor agent
ebm-papst ebm-papst
Landshut GmbH Heating Systems B.V.