Sie sind auf Seite 1von 74

www.ebmpapst.

com 37895-7-8811 · 2019-03 ·mc-2`

Condensing boiler technology


Printed in Germany

Condensing boiler technology · Edition 2019-03


Product Catalogue 2019-03

the engineer’s choice the engineer’s choice

ebm-papst ebm-papst
Landshut GmbH Heating Systems B.V.

Hofmark-Aich-Straße 25 Van Veldekekade 360


84030 Landshut 5216 KT ’s-Hertogenbosch
Germany Netherlands
Phone +49 871 707-0 Phone +31 73 648 89-00
Fax +49 871 707-465 Fax +31 73 648 89-11
info3@de.ebmpapst.com info@ebmpapst-hs.nl
ebm-papst in Oceania

Oceania

Australia
ebm-papst A&NZ Pty Ltd.
10 Oxford Road
Laverton North, Victoria, 3026
AUSTRALIA
Phone +61 3 9360-6400
Fax +61 3 9360-6464
sales@ebmpapst.com.au
www.ebmpapst.com.au

New Zealand
ebm-papst A&NZ Pty Ltd.
61 Hugo Johnston Drive, Unit H
Penrose 1061, Auckland
NEW ZEALAND
PO Box 112278,
Penrose 1642, Auckland
Phone +64 9 525-0245
Fax +64 9 525-0246
sales@ebmpapst.com.au
www.ebmpapst.com.au

Agents
fan agent compact fan agent motor specialist motor agent

2 Condensing boiler technology · Edition 2019 - 03


EC radial blowers for
condensing boiler technology

the engineer’s choice


Page Page

Information 4 About ebm-papst 4


GreenIntelligence 5

Information
Gas condensing technology 6
Laboratory equipment 10
Systems for condensing boiler technology 12
System solutions 14

EC radial blowers 18 VG 71 20
VG 100 22
VG 108 24
NRG 118 26
RG 148 28
NRG 137 30

EC radial blowers
RG 175 32
G1G 170 34
G3G 200 36
G3G 250 38
G3G 250 MW 40
G3G 315 42
VG 450 44

46
46 Connectors
Electrical interfaces 48

Gas valves for 52 G15/G20 E01 54


pneumatic and G20 D01 56

Gas valves
electronic gas air ratio
control systems G15/G20 F01 58
G32 F01 60
G40 F01 62

control units
Burner control units 64 Commercial range 65

Burner
Residential range 66

Agents 67
Agents
Worldwide

Condensing boiler technology · Edition 2019 - 03 3


About ebm-papst
ebm-papst is a leader in ventilation and drive engineering technology and a much sought-after engineering partner in many industries. With around
20,000 different products, we have the perfect solution for practically every requirement. We have placed the highest emphasis on economy and
ecology for many years.

We believe the consistent further development of our highly-efficient GreenTech EC technology provides our customers with the best opportunities
for the future in industrial digitization. With GreenIntelligence, ebm-papst already offers intelligent networked complete solutions that are unique
anywhere in the world today and that secure our customers a decisive advantage.

Six reasons that make us the ideal partner: Closeness to our customers.
ebm-papst has 25 production locations worldwide (including facilities
Our systems expertise. in Germany, China and the USA), together with 49 sales offices,
You want the best solution for every project. The entire ­ventilation each of which has a dense network of sales representatives. You will
system must thus be considered as a whole. And that’s what we always have a local contact, someone who speaks your ­language and
do – with motor technology that sets standards, sophisticated knows your market.
­electronics and aerodynamic designs – all from a single source and
perfectly matched. Our standard of quality.
Our quality management is uncompromising, at every step in every
Our spirit of invention. process. This is underscored by our certification according to
We are also always able to develop customized solutions for you ­inter­national standards including DIN EN ISO 9001, TS declaration
with our versatile team of over 600 engineers and technicians. of c­ onformity and DIN EN ISO 14001.

Our lead in technology. Our sustainable approach.


We are not only pioneers and trailblazers in the development of Assuming responsibility for the environment, for our employees
highly efficient EC technology, we also recognized the opportunities and for society is an integral part of our corporate philosophy.
of digitization at an early stage. Therefore, we can offer solutions We develop products with an eye to maximum environmental com­
­today that combine the highest energy efficiency with the advantages patibility, in particular resource-preserving production methods.
of IoT and digital networking. We promote environmental awareness among our young staff
and are actively i­ nvolved in sports, culture and education. That’s
what makes us a leading company – and an ideal partner for you.

4
The next level of Green

Sustainability and environmental protection are more than just buzz- GreenIntelligence optimizes processes.
words for us, they are a pivotal part of our company philosophy. Our Today, the greatest economic opportunities for industrial systems are
commitment includes green production, dealing responsibly with in process efficiency. Digital connectivity for all components enables
­resources and society, and finished products that use energy effi- better process planning, faster troubleshooting, and optimization
ciently – things for which our globally respected GreenTech label has of their overall interaction. ebm-papst supplies both the physical
stood for many years. components and the smart control systems that are required for this.

GreenIntelligence is the logical next step in the evolution of GreenTech. GreenIntelligence for smart solutions.
In a nutshell, it is everything GreenTech stands for, enhanced by the When it comes to choosing the right drive or fan, product character-
possibilities and opportunities of digital connectivity, the Internet of istics such as energy efficiency and performance figures are no longer
Things and artificial intelligence. For our customers, that means we the only crucial factors; the optimum interaction of all components
bring their applications to a completely new level by adding new value in a process is what matters. Our GreenIntelligence solutions can
that goes far beyond the purely physical capabilities of individual communicate with their environment. They gather and analyze data
fans or drives. Think of remote monitoring, predictive maintenance, and adjust to conditions to ensure the best possible performance.
self-optimizing processes: ebm-papst makes all of these things pos-
sible today with integrated solutions featuring smart connectivity for GreenIntelligence is limitless connectivity.
ventilation and drive engineering applications. Or simply: the next All GreenIntelligence products have full Industry 4.0 capability and
level of Green. can be integrated in any system quickly and easily thanks to
plug & play, minimizing the amount of effort involved in installation
and adjustment for our customers.

GreenIntelligence is self-improving.
In the data it gathers, the system software supplied by ebm-papst
can recognize potential for optimization and, if desired, implement
it automatically – the first step toward artificial intelligence.

Here is how much GreenIntelligence there is in RadiMix:


–– Future-proof thanks to full Industry 4.0 capability
–– System data readout through LIN bus connectivity
–– Easy integration of digital heating functionality
–– Status monitoring of blower and environment
–– Predictive maintenance for lower servicing costs –
­maintenance only when really needed
–– Can be used in combination with renewable
energy sources
–– Perfectly adjusted and network-capable integrated
solution from a single source

5
Gas condensing technology
That's ebm-papst

6
Information
Since creating the world’s first gas blower for condensing technology, we have been the
market leader for efficient components and complete, perfectly matched systems. We
develop blowers, venturis, valves and burner controls together with our customers and
supply everything as a full package. Enjoy the benefits of our well-established and
constantly updated technology combined with unique system expertise.

More than just combustion Advantages at a glance


Modern gas condensing units are known for their productivity and – System and development expertise from the market leader
efficient energy utilization. They have to be supplied with exactly
– Unrivaled power and modulation spectrum
the right amount of gas and air in an ideal ratio for every operating
– Well-established technology guarantees a long service life
status and under all ambient conditions. Only then is hygienic and
efficient combustion guaranteed. Compact dimensions keep the – High power density thanks to compact design
installation space to a minimum and at the same time provide – Outstanding efficiency levels
better accessibility. – Extremely smooth operation with a low noise level
– Pre-matched components for easy adaptation to the
ebm-papst offers the world’s most extensive product range for
respective application
condensing technology. From just a few kilowatts for use in private
households to several megawatts for supplying entire residential – Future-proof thanks to BUS connection option
areas: We will always find the right solution. Our portfolio contains
efficient EC radial blowers, gas valves and perfectly matched
system solutions for every application.

Condensing boiler technology · Edition 2019 - 03 7


Ideally suited
for all applications
Information

Residential technology 150 kW

Gas condensing heating systems for private households

Use as heating unit only, as combi-boiler


or in conjunction with regenerative energies

2 kw

8 Condensing boiler technology · Edition 2019 - 03


Apartment blocks / residential areas

Information
Commercial technology

The first condensing blower for heat output up to 4 MW


rounds off our extensive product portfolio

For decentralized heating solutions keeping construction


Gas condensing heating systems for applications ranging work and heat loss from long pipes to a minimum
from small trade businesses to heating installations in large compared to large Combined Heat and Power stations
industrial plants

From single boiler to cascade system installations

4 MW

Condensing boiler technology · Edition 2019 - 03 9


Laboratory equipment

As market and technology leaders, we are constantly endeavoring to For example our checks include examining design influences such
improve our performance and provide our customers with the best as modifications to the gas-air mixing device, the backflow flaps or
Information

possible complete solution. Our engineers and technicians assist our the venturi. All these factors can affect the efficiency, noise level
customers with the development of their application right from the and functionality of a condensing heating system. We take measure-
start to help advance the process of improvement. Before series ments on gas-air composite systems directly in the heating unit
launch we conduct extensive tests to ensure compliance with legal to ensure ideal matching of the individual components and motor
requirements and customer specifications. We have a wide range of performances. This is accompanied by flow simulation with direct
measuring equipment at our disposal for this purpose. incorporation of the results obtained.

Gas laboratory: Climate chambers:


– Highly advanced measuring equipment with all the standard – Environmental simulation and service life
test and limit gases used in Europe, America and Asia tests with more than 30 climatic, cold and
– Exhaust gas measurements (CO2, CO, air ratio), measure- warm chambers
ments with variable aerodynamic parameters (venturi pres- – Simulation of temperature range from
sure, mass flow, exhaust gas back pressure) to increase and 70°C to 300°C possible
optimize the modulation range
– Measurement of thermal and electrical performance data
– Simulation of wind and turbulence in the exhaust gas area,
e. g. for electronic gas-air composite systems Air performance test stands:
– Communication with all standard bus systems,  hecking of the operating characteristics of
C
e. g. CANbus, LINbus, Modbus, ebus, OpenTherm blowers and systems with recording of the
air performance curves

10 Condensing boiler technology · Edition 2019 - 03


Endurance test rooms: Vibration test:

Information
About 150 different endurance For simulation of transpor-
tests with over 700 specimens tation and operation with
in progress different vibration profiles
Sound measurement laboratory:
Precise sound power and gas
measurement technology with
incorporation of real conditions

EMC measurement room: Approvals: Standards and Directives:


Emission and immission AGA, CCC, CSA, DVGW, – Low-Voltage Directive
measurements EAC, KIWA, TÜV, UL, VDE – Machinery Directive
– Gas Appliance Regulation
– EMC Directive

Additional equipment:
– 3D microscope
– 3D plotter
Gas valve test stands:
For gas valves with pneumatic and
electronic modulation

Condensing boiler technology · Edition 2019 - 03 11


Systems
for condensing boiler technology

An optimum gas-air mixing ratio is crucial to the energy yield realized modulation level are determined among others by the minimum and
during combustion. The mixing ratio needs to be exactly adjusted maximum output of the premixing blower. This means its compo-
Information

to the heating value of the gases being used (e.g. natural gas, LPG nents need to be perfectly matched. That’s why we offer complete
or biogas). An additional challenge is the flexibility of heat output. heating systems including gas blowers, venturis, gas valves and
The greater the modulation range of a heating system, the better burner control units from a single source.
its heating output can be adjusted to actual needs. The limits of the

Ideally suited for use in electronic or pneumatic gas air ratio control systems

Electronic gas air ratio control system


gas air unit

gas

flame detection
air gas air
mixture

burner

LIN
electronic
control
LIN LINbus BCU info flame detection
communication

Electronic gas air ratio control system

pumps

Pneumatic gas air ratio control system


gas air unit

control pressure

gas

air gas air


mixture

burner

speed control (PWM)

burner control unit (BCU)

12 Condensing boiler technology · Edition 2019 - 03


Gas blower:

Information
State-of-the-art blower
technology for modulating
operation with low noise
and a long service life

Venturi:
The pressure generated by
the venturi effect provides an
optimum mixture of gas and
air in the pneumatic gas-air
ratio control

Gas valve:
The component required for the
reliable supply of gas has
a particularly compact design

Burner control with display:


The electronic control is matched precisely to the system.
Signals from the burner control can be evaluated in the lab using
LabVision software

Condensing boiler technology · Edition 2019 - 03 13


Our system solutions
at a glance

All heating technology components must be perfectly harmonized in Our multi-venturi solutions provide you with a wide variety of motor
order to achieve optimum performance and efficiency. This is why performances and options for assigning our systems to your devices.
Information

we offer complete heating systems, including gas blower, venturi This gives you the benefit of flexible integration into compact spaces.
and gas valve, from a single source.
We supply our systems as completely tested, harmonized units with
A key benefit of our gas-air composite systems is their optimal optimized interfaces to minimize your effort.
mixing ratio with simultaneously high modulation ranges. To achieve
this high level of efficiency, we provide different venturi elements for
multi-venturis, depending on the heat output range.

Mounting positions
With horizontal shaft or vertical shaft with motor positioned at top

Illustration examples

System solutions

System Heat output range Gas valve Max. motor power

[kW]  [W] 

2 – 15
HS0077E1PXXS 5 – 28 G15 E01 62
(NRV 77)
7 – 35

3 – 23
HS0118E1PXXS 5 – 28 G15 E01 70
(NRV 118)
7 – 42

10 – 65 G15 D01
HS0148D1PXXS 200
(NRV 148)
20 – 110 G20 D01

15 – 90 200
HS0137D1PXXS G20 D01
(NRV 137)
24 – 145 300

14 Condensing boiler technology · Edition 2019 - 03


Information
Heat load in kW

140 160
100 120
60 80
20 40
kW

Heat output range depending on type of gas concerned and system conditions.

Condensing boiler technology · Edition 2019 - 03 15


Our system solutions
at a glance
Information

NRV 77  The system for heat outputs from 2 to 35 kW


– Gas blower NRG 77 with multi-venturi
– Gas valve G15 E01
– Operating voltage 230 V, option of 120 V
– 24 V gas valve on request
178 m
m
– Further heat output ranges on request

Nominal data

Type Heat output range [kW] * Part number

2 – 15 5573433000

HS0077E1PXXS 5 – 28 5573433010
157
mm 7 – 35 5573433020
204 mm
Sample on request
* Approximate figures. Heat output range depending on type of gas concerned
and system conditions.

NRV 118  The system for heat outputs from 3 to 42 kW


– Gas blower NRG 118 with multi-venturi
– Gas valve G15 E01
– Operating voltage 230 V, option of 120 V
– 24 V gas valve on request
175 m
m – Further heat output ranges on request

Nominal data

Type Heat output range [kW] * Part number.

3 – 23 5573432010

HS0118E1PXXS 5 – 28 5573432020
163
mm 7 – 42 5573432030
224 mm
Sample on request
* Approximate figures. Heat output range depending on type of gas concerned
and system conditions.

16 Condensing boiler technology · Edition 2019 - 03


Information
NRV 148  The system for heat outputs from 10 to 110 kW
– Gas blower RG 148 with multi-venturi
– Gas blower G15 D01 (5571450000);
G20 D01 (5572450000)
– Operating voltage 230 V, option of 120 V
205 m
m – 24 V gas valve on request

Nominal data

Type Heat output range [kW] * Part number

10 – 65 5571450000
HS0148D1PXXS
20 – 110 5572450000
259
mm
* Approximate figures. Heat output range depending on type of gas concerned
256 mm
Sample on request and system conditions.

NRV 137  The system for heat outputs from 15 to 145 kW


– Gas blower NRG 137 with multi-venturi
– Gas valve G20 D01
– Operating voltage 230 V, option of 120 V
– 24 V gas valve on request
213 m
m

Nominal data

Type Heat output range [kW] * Part number

15 – 90 5572410000
HS0137D1PXXS
24 – 145 5572410020
240 * Approximate figures. Heat output range depending on type of gas concerned
mm
271 mm and system conditions.
Sample on request

Condensing boiler technology · Edition 2019 - 03 17


EC radial blowers

Modern gas-fired modulated condensing units have to be supplied solutions for this application area. However, the special properties
with the optimum volume and mixture of air and fuel in all operating of these blowers make them suitable for many other applications as
modes and ambient conditions. They require adjustable blowers well. Examples include gas-powered cooking appliances for the food
with steep pressure/air flow characteristic curves and high maximum service industry or gas-powered deep fryers for commercial use.
pressures. ebm-papst played a significant role in developing
EC blowers for this purpose and now offers the widest range of

Heat load in kW

... 4000
2000
EC radial blowers

1500 1750
1000 1250
500 750
kW 250

Heat output range depending on type of gas concerned and system conditions.

18 Condensing boiler technology · Edition 2019 - 03


Drive:
– Brushless DC (EC) motors with integrated electronics
– Vibration-free mounting to minimize structure-borne sound
– Adjustment of motor power on an individual basis

Commutation electronics:
– Integrated into the blower unit and Housing:
perfectly harmonized with the motor – Made of die-cast aluminum
– Integrated blockage switch-off and – (respectively cast aluminium/sheet steel)
overheating protection as per EN 60335 – Required density thanks to special seal
– Various standard interfaces available for housing halves and drive shaft conduit
for the respective burner control – Outlet flange adjustable to many designs
– Optimized in accordance with EMC
emissions and pollution Impellers:
– For type VG, NRG und RG
blowers of pentane-resistant
plastic: dynamically fine
balanced
– For the G1G 170,
Speed controls: G3G 200, G3G 250,
– Adjustment required in individual cases G3G 250MW, G3G 315 and

EC radial blowers
– Controlled via PWM signal VG 450 models made of
– 0–10 V input optional sheet aluminum
– Bus communication optional

Bearings:
– Maintenance-free ball bearings
covered on both sides for long
service life and smooth operation
– Use of lubricants suited for the
particular application

Protection class:
Protection class I

Degree of protection:
Degree of protection IP20 with
cover, depending on the Installati-
on position
Mounting positions:
– With horizontal shaft or vertical shaft with motor
Speed output:
positioned at top
– With Hall IC signal output; in case of motors for line voltage
– For vibration-cushioned motor installation, the
operation, speed signal output is galvanically isolated
motor’s weight is additionally supported by a
– VG, NRG and RG blowers, each with two pulses per revolution
flexible element.
– G1G and G3G blowers, each with three pulses per revolution
– G3G 250 MW blower with four pulses per revolution
– G3G 315 and VG 450 blower with five pulses per revolution

Condensing boiler technology · Edition 2019 - 03 19


EC radial blower
VG 71

Material/surface
■■ Housing: Die-cast aluminium/sheet steel
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multiventuri on request
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com
in. wg
Pa

A
2000
8

1500
6

1000
4

500
2

0 10 20 30 40 50 cfm
pfs

qv 20 40 60 80 m3/h

A
W

60

45

30

15

0 10 20 30 40 50 cfm
pw

qv 20 40 60 80 m3/h

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

20 Condensing boiler technology · Edition 2019 - 03


EC radial blower VG 71

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 220/240 V AC, 50/60 Hz
A 14000 65 60 60

Subject to change. Available with the option of a more powerful motor.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0071MSGBS 5566780050 0.9

EC radial blowers
A Technical drawing Dimensions in mm

81±1
39.25
Y 5.55 (2x)
Ø83
Ø71

45.3
24.3
Z Ø5.55 (2x)
12.6
45 29.2
172

° 45°
54

Y 6x
60
Z (=3
60
°)
Ø80

25
5.7+0.2
-1.0

81.2 M6 (6x)
164

① Groove suitable for round sealing ring 63 x 3


② 6.5 deep

Condensing boiler technology · Edition 2019 - 03 21


EC radial blower
VG 100

Material/surface
■■ Housing: Die-cast aluminium/sheet steel
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multiventuri on request
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com
in wg
Pa

A
2000
8.0

1500
6.0

1000
4.0

500
2.0

0 10 20 30 40 50 60 cfm
Pfs

qV 20 40 60 80 100 m3/h

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

22 Condensing boiler technology · Edition 2019 - 03


EC radial blower VG 100

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 220/240 V AC, 50/60 Hz
A 10000 90 60 60

Subject to change. Available with the option of a more powerful motor.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0100MSGBS 5566780041 0.9

EC radial blowers
A Technical drawing Dimensions in mm

81±1
39.25
Y
5.55 (2x)

Ø71

51.6
Ø83

25.2
Z
Ø5.55 (2x)
12.6
172

45° 28.1 45°


54

6x
Y Z 60
° (=
36

)
Ø80

+0.2
25
5.7 -1.0
81.2 M6 (6x)
164 ②

① Groove suitable for round sealing ring 63 x 3


② 6.5 deep

Condensing boiler technology · Edition 2019 - 03 23


EC radial blower
VG 108

Material/surface
■■ Housing: Die-cast aluminium/sheet steel
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multiventuri on request
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

24 Condensing boiler technology · Edition 2019 - 03


EC radial blower VG 108

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 220/240 V AC, 50/60 Hz
A 10000 135 60 60

Subject to change. Available with the option of a more powerful motor.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0108MSGDS 5566780061 1.1

EC radial blowers
A Technical drawing Dimensions in mm

103.6 ±1
45.1
Y

61.1
Ø83
Ø71

30.9
Z Ø5.55 (4x)
15.6
192.5

45° 33.9
45°
66

Y Z
3x
12

(=3
60
Ø100

28.4
3x

6.5+0.2
12

-1.0
89

M6 (3x)
(=3


183.4
60


°)

M4 (3x)

① Groove suitable for round sealing ring 70 x 3
② 6.5 deep
③ 7.5 deep

Condensing boiler technology · Edition 2019 - 03 25


EC radial blower
NRG 118

Material/surface
■■ Housing: Aluminium
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multi-venturi available
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

A
3000
12

2000
8

1000
4

Maximum operating range


maximaler Arbeitsbereich

0 10 20 30 40 50 cfm

10 20 30 40 50 60 70 80 90
W

100

90

75 A
60

45

30 B
15

0 10 20 30 40 50 cfm
w

10 20 30 40 50 60 70 80 90

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

26 Condensing boiler technology · Edition 2019 - 03


EC radial blower NRG 118

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 230 V AC, 50 Hz
A 10000 70 60 60 1)
Nominal voltage 115 V AC, 60 Hz
B 10000 61 60 60 1)

Subject to change. Available with the option of a more powerful motor.


1) Temperature depending on temperature-time profile. Higher temperatures on request.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0118NSHCS 5566731160 1.0
B VGR0118NSHCS 5566730030 1.0

EC radial blowers
A Technical drawing Dimensions in mm

max. 93
ca. 9°
ca. 39.9
42° Y Ø5.55 (4x)

26
50.3
Ø83
Ø71

Z
16.4
28.9
174.3

45°
45°
57.8

6x 6
° (=3 0
Z 6
60 0°)

°
Y M4 (3x)
30°
Ø100
Ø80

5.5 +0.2
-1.0
19.3
84.5
162.9
M6 (6x)

① ②

① Groove suitable for round sealing ring 63 x 3


② 6.5 deep

Condensing boiler technology · Edition 2019 - 03 27


EC radial blower
RG 148

Material/surface
■■ Housing: Aluminium
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multi-venturi available
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

5000
20

A
4000
16

3000
12

2000 B
8

1000
4

Maximum operating range


maximaler Arbeitsbereich

0 20 40 60 80 100 120 cfm

25 50 75 100 125 150 175 200


W

200
A
150

100

B
50

0 25 50 75 100 125 cfm


w

25 50 75 100 125 150 175 200

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

28 Condensing boiler technology · Edition 2019 - 03


EC radial blower RG 148

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 230 V AC, 50/60 Hz
A 9000 200 60 60
Nominal voltage 120 V AC, 60 Hz
B 8200 130 60 60

Subject to change. Available with the option of a more powerful motor.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0148XSHGS 5566725230 2.1
B VGR0148XSHGS on request 2.0

EC radial blowers
A Technical drawing Dimensions in mm

max. 143
41.2
Y Ø5.55 (4x)
Ø83
Ø71
56

Z
16.3
197.6

45° 30.2 45°


Ø5.55 (3x)
75

Z ② 3x
12
0
Y 12 ° (=
0° 36

)
Ø100

5.9+0.2
-1.0 22
90.4
184.3
120


°

3x
120
° (=
360 Ø3.7 (3x)
°)

① Groove suitable for round sealing ring 70 x 3


② 10.5 deep
③ 9.5 deep

Condensing boiler technology · Edition 2019 - 03 29


EC radial blower
NRG 137

Material/surface
■■ Housing: Aluminium
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
■■ Multi-venturi available
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

3000
12

2000 B
8

1000 A
4

Maximum operating range


maximaler Arbeitsbereich

0 20 40 60 80 100 120 140 cfm

25 50 75 100 125 150 175 200 225


W

B
250

200

A
150

100

50

0 25 50 75 100 125 cfm


w

25 50 75 100 125 150 175 200 225

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

30 Condensing boiler technology · Edition 2019 - 03


EC radial blower NRG 137

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 230 V AC, 50/60 Hz
A 8500 220 60 60
Nominal voltage 120 V AC, 60 Hz
B 8500 250 60 60

Subject to change. Available with the option of a more powerful motor.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0137NSHGS 5566733110 1.9
B VGR0137NSHGS 5566733040 2.4

EC radial blowers
A Technical drawing Dimensions in mm

max. 150
52.8
Y Ø5.55 (4x)

Ø83
Ø71
55
27.7

Z
Ø89.6

21
45° 42 45°
210.1


75.2

3x
12

(=3
Z 60
°)
Y
120
°
Ø100

5.9+0.2
-1.0
30.7
86.3
186.9 3x 12
12 0° M4 (3x)


(=3
60 M6 (3x)
°)

① Groove suitable for round sealing ring 70 x 3


② 6.5 deep
③ 7.5 deep

Condensing boiler technology · Edition 2019 - 03 31


EC radial blower
RG 175

Material/surface
■■ Housing: Aluminium
■■ Impeller: Plastic
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

4000
16

3000
A
12

2000
8

B
1000
4

Maximum operating range


maximaler Arbeitsbereich

0 50 100 150 200 cfm

50 100 150 200 250 300 350


W

A
250

200
B
150

100

50

0 50 100 150 200 cfm


w

50 100 150 200 250 300 350

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

32 Condensing boiler technology · Edition 2019 - 03


EC radial blower RG 175

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 230 V AC, 50/60 Hz
A 6250 270 60 60
Nominal voltage 120 V AC, 60 Hz
B 6250 240 60 60

Subject to change. Available with the option of a more powerful motor.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0175XSHGS 5566714090 2.9
B VGR0175XSHGS 5566714002 2.8

EC radial blowers
A Technical drawing Dimensions in mm

max. 161
63.1
Y
Ø9 (4x)

R29.4
110

59.7
56

Z
24
67.2
255

90
92.15

126

12x
Z 3
30° 0° (=36
Y 0°)
Ø140

7+0.2
-1.0 36.5
114.3
231.14


M8 (12x)

① Groove suitable for round sealing ring 110 x 3.4


② 8.5 deep

Condensing boiler technology · Edition 2019 - 03 33


EC radial blower
G1G 170

Material/surface
■■ Housing: Aluminium
■■ Impeller: Sheet aluminium
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

3000
12

B
2000
8

1000
4

0 100 200 300 400 cfm

100 200 300 400 500 600 700


W

400
A

300

200
B

100

0 100 200 300 400 cfm


w

100 200 300 400 500 600 700

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

34 Condensing boiler technology · Edition 2019 - 03


EC radial blower G1G 170

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 1~230 V AC, 50/60 Hz
A 7200 420 55 80
Nominal voltage 1~115 V AC, 50/60 Hz
B 7200 360 55 80

Subject to change.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0170XSPGS 5560001180 5.0
B VGR0170XSPGS 5560001010 5.0

EC radial blowers
B Technical drawing Dimensions in mm

177 ② 6x
60
257 44 M8 (6x) ° (=
36

)
Ø140
280

101
165

60
95
98
Ø9


6.5
120
123
140

① Groove suitable for round sealing ring 110 x 3.2


② 9.5 deep

Condensing boiler technology · Edition 2019 - 03 35


EC radial blower
G3G 200

Material/surface
■■ Housing: Aluminium
■■ Impeller: Sheet aluminium
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

A
3000
12

B
2000
8

1000
4

0 150 300 450 600 cfm

240 480 720 960


W

750
750

A
500
500

B
250
250

0 200 400 600 cfm


w

240 480 720 960

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

36 Condensing boiler technology · Edition 2019 - 03


EC radial blower G3G 200

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 1~230 V AC, 50/60 Hz
A 6100 890 50 50
Nominal voltage 1~115 V AC, 50/60 Hz
B 5700 800 60 60

Subject to change.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0200XSPKS 5560003030 10
B VGR0200XSPKS 5560003051 10

EC radial blowers
A Technical drawing Dimensions in mm

237 ② 6x
60
323 56 M8 (6x) ° (=
36

)
Ø220
355

124

90
113
117
Ø9

9

140
168
180

① Groove suitable for round sealing ring 180 x 3.5


② 12 deep

Condensing boiler technology · Edition 2019 - 03 37


EC radial blower
G3G 250

Material/surface
■■ Housing: Aluminium
■■ Impeller: Metall
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

B
3000
12

A
2000
8

1000
4

0 200 400 600 800 cfm

200 400 600 800 1000 1200 1400


W

1000

800
B
600

400
A
200

0 200 400 600 800 cfm


w

200 400 600 800 1000 1200 1400

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

38 Condensing boiler technology · Edition 2019 - 03


EC radial blower G3G 250

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 1~230 V AC, 50/60 Hz
A 5200 1150 60 60
Nominal voltage 1~115 V AC, 50/60 Hz
B 5200 1200 60 60

Subject to change.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0250XSPKS 5560005021 13
B VGR0250XSPKS 5560005051 13

EC radial blowers
A Technical drawing Dimensions in mm

121
250
② 6x
444 66 M8 (6x) 60
° (=
36

)
Ø220
474

171

165
169

92

11 180

Ø9

205 220

① Groove suitable for round sealing ring 180 x 3.5


② 12 deep

Condensing boiler technology · Edition 2019 - 03 39


EC radial blower
G3G 250 MW

Material/surface
■■ Housing: Aluminium
■■ Impeller: Sheet aluminium
■■ Motor housing: Metall
Mechanical data
■■ Degree of protection: IP20 with cover,
depending on the Installation position
■■ Installation position: With horizontal shaft or
for vertical shaft with motor position above
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

6000
24

4000
16

2000
8

0 250 500 750 1000 cfm

400 800 1200 1600

A
W

2000

1500

1000

500

0 250 500 750 1000 cfm


w

400 800 1200 1600

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

40 Condensing boiler technology · Edition 2019 - 03


EC radial blower G3G 250 MW

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 3~380 – 480 V AC, 50/60 Hz
A 6400 2500 50 50

Subject to change.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0250XTRHS G3G250MW5001 24

EC radial blowers
A Technical drawing Dimensions in mm

377 ±2
120.5 Ø220
M20x1.5 (3x)

Z

Ø120

Ø260
459 ±1

171
265

°
6x60
169.4

66.3

Z

M8 (6x)


12 +1
Ø9 (4x)

8 92
204.5 180
435 ±1 220
Ø178.6
5

2.9

① Cable diameter min. 4 mm, max. 10 mm, tightening torque 4 ± 0.6 Nm


② Clearance for screw 10-12 mm, tightening torque 20 ± 3 Nm
③ Tightening torque 3.5 ± 0.5 Nm

Condensing boiler technology · Edition 2019 - 03 41


EC radial blower
G3G 315

Material/surface
■■ Housing: Aluminium
■■ Impeller: Sheet aluminium
■■ Motor protection cap: Plastic
Mechanical data
■■ Degree of protection: IP20 with cover
■■ Installation position: Any
■■ Mounting: Ball bearings
Electrical data
■■ Protection class I
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

6000
24

4000
16

2000
8

0 500 1000 1500 2000 2500 cfm

1000 2000 3000 4000

A
W

6000

4000

2000

0 500 1000 1500 2000 2500 cfm


w

1000 2000 3000 4000

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

42 Condensing boiler technology · Edition 2019 - 03


EC radial blower G3G 315

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 3~380 – 480 V AC, 50/60 Hz
A 6000 8000 60 60

Subject to change.

EC radial blower
Curve

Type Part number Weight


kg
A VGR0315XTTLS 5560007000 36

EC radial blowers
A Technical drawing Dimensions in mm

X max. 370 528.9


2:1 162 256
3.1
5.3

X
10.3
Ø154.6

95
549.5

131.9

190
4
29
200.3

Ø
207.3
266
300

Ø 11(4x) 134.2
216
250

Condensing boiler technology · Edition 2019 - 03 43


EC radial blower
VG 450

Material/surface

■■ Housing:
■ Gehäuse:Die-cast
Aluminiumaluminium
■ ■ Impeller: Sheet
■■ Impeller: plasticaluminium

■■■ Motor
: casing: Cast aluminium
■■ Electronics box: Cast aluminium
Mechanical
Mechanical data
data

■■ :Protection
■ IP20 mit Abdeckhaube, abhängig von der
class blower: IP00
■■ Protection
: mit waagerechter Welle oder
class electronics: bei senkrechter
IP54
Welle mit Motorlage
Protection oben
class motor: IP20
■■ Installation
Mounting: free ball bearings
position: Any
■■ Mounting: Ball bearings
Electrical
Electrical data:
data

■■ Protection class
■ Protection class II
EC radial blowers

on Page 14 Possible mounting positions


on Page 46 Mains connector X, interface connector W
on Page 48 Electrical interfaces
More at www.ebmpapst.com

A
30

6000
25
20

4000
15
10

2000
5

0 1000 2000 3000 4000 cfm

2000 4000 6000 8000

A
W

12000

10000

8000

6000

4000

2000

0 1000 2000 3000 4000 cfm


w

2000 4000 6000 8000

Measuring requirements
Air performance measured according to: ISO 5801 with ebm-papst scroll housing without touch protection. The information is only
applicable under the specified measuring or standard conditions (15 °C, 1013 hPa, 1,225 kg/m3) and may change depending on the
installation conditions.In case of deviation from the standard configuration and depending on the type of gas, the heat output must be
checked when installed.

44 Condensing boiler technology · Edition 2019 - 03


EC radial blower VG 450

amb. motor temp.

temp. of medium
input power Ped
Max. speed n

Max. perm.

Max. perm.
Curve

Max.
min⁻¹ W °C °C
Nominal voltage 3~380-480 V AC, 50/60 Hz
A 4250 14000 401) 50

1) short-term 60

Subject to change.

EC radial blower
Curve

Type Part number Weight


kg
A VGR450XTTPS on request 85

EC radial blowers
A Technical drawing Dimensions in mm

863.4
462.4
474
194.2
Z
5.5

2.7
20.5

Z
Ø182

106
786

276.5
05
Ø3
50
268.6
400

Ø3
279
356


Ø13 (8x)
163.5
282
326

① Seal groove

Condensing boiler technology · Edition 2019 - 03 45


Connectors

G3G 250 MW
NRG 118

NRG 137

G3G 200

G3G 250
G1G 170

G3G 315
RG 148
VG 108

VG 450
VG 100

RG 175
VG 71

Connector
1 Mains connector X x x x x x x x

see operating instructions

see operating instructions

see operating instructions


2 Mains connector X x x x x x x x

3 Interface connector W x x

4 Interface connector W x x x x x x

5 Interface connector W x x
EC radial blowers

6 Interface connector W

Interface 04600451… 31 31 31 04 04 04 04 38 39 39 64 61 63

Connectors refer to 230 V versions. Further connector types on request.

1 Mains connector X
3-pin pin-connector with coding type 0A according to RAST 5
in 90° angled / horizontal design
with locking feature on top or down for locking device suitable for
mating connector according to RAST 5
with coding type 0A as e. g.
CoHaMo YY-A5002-H03-K01 or Lumberg 3623 03 K01
① ② ③
Part number for mating connector:
2431045025
① Power supply AC
② Protective earth
③ Power supply AC

2 Mains connector X
3-pin pin-connector according RAST 6.35
in 90° angled / horizontal design
suitable for mating connector according to RAST 6.35
e. g. Tyco Universal MATE-N-LOK
Order number: 1586847-1 and 3 x socket 926882-1 ① ② ③
Part number for mating connector:
Connector shell 2430945012; Crimp socket 2430745002/3
① Protective earth
② Power supply AC
③ Power supply AC

46 Condensing boiler technology · Edition 2019 - 03


3 Interface connector W
4-pin pin-connector according RAST 3.0
in 90° angled / horizontal design
suitable for mating connector according RAST 3.0
e. g. Molex Micro-Fit 3.0
Order number: ① ② ③ ④
43645-0408 and 4 x socket 43030-0001
Part number for mating connector: ① Power supply - (GND)
Plug shell 2431045133; ② PWM Input
Crimp socket 2430045128 ③ Hall Sensor OUT
④ Power supply +

4 Interface connector W
5-pin pin-connector according RAST 4.2
in 90° angled / horizontal design
suitable for mating connector
e. g. Stocko STO-FIT, CoHaMo
① ② ③ ④ ⑤
Order number Stocko:
EH 705-005-004-960 and 5 x socket RBB 8230.120

EC radial blowers
① Power supply - (GND)
Order number CoHaMo: ② PWM Input
YY-5700-H05AS-GW ③ NC

Part number for mating connector: ④ Hall Sensor OUT

Connector shell 2430945035; Crimp socket 2430845065 ⑤ Power supply +

5 Interface connector W
5-pin pin-connector according RAST 4.2
in 90° angled / horizontal design
suitable for mating connector
e. g. Stocko STO-FIT, CoHaMo
① ② ③ ④ ⑤
Order number Stocko:
EH 705-005-004-960 and 5 x socket RBB 8230.120
① Power supply - (GND)
Order number CoHaMo: ② PWM Input
YY-5700-H05AS-GW ③ Input 0-10 V DC Control

Part number for mating connector: ④ Hall Sensor OUT

Connector shell 2430945035; Crimp socket 2430845065 ⑤ Power supply +

6 Interface connector W
5-pin pin-connector according RAST 4.2
in 90° angled / horizontal design
suitable for mating connector
e. g. Stocko STO-FIT, CoHaMo
① ② ③ ④ ⑤
Order number Stocko:
EH 705-005-004-960 and 5 x socket RBB 8230.120
① Power supply - (GND)
Order number CoHaMo: ② PWM Input
YY-5700-H05AS-GW ③ Input 0-10V DC Control

Part number for mating connector: ④ Hall Sensor OUT

Connector shell 2430945035; Crimp socket 2430845065 ⑤ Voltage Output

Condensing boiler technology · Edition 2019 - 03 47


Electrical
interfaces

Further types available on request.

Interface 31  120/230 VAC, 50/60 Hz

18-43VDC
1

15K
1K
HS
12V

22K 2
EC radial blowers

10nF
4K7

7.5V
22K
12K

PWM
3/4 - Safe start PWM >20%
1K 12K
- Hallsignal: 2 pulses per revolution
- PWM "HIGH" = blower ON
- PWM "LOW" = blower OFF

GND
4/5

customer circuit - example ebm-papst circuit

Interface 04  120/230 VAC, 50/60 Hz

1 +18..43VDC
15K

Vcc
2 Hallsignal
2 pulses per revolution 1K
Hall Signal
12V

1K

3 N.C.
12K
6K8

5V1

4 PWM 1-6kHz 12K


1K Digital PWM
Safe Start: >20% PWM
PWM-low = Blower off
PWM-high = Blower on

PWM-Signal
GND
5 GND

customer circuit (example) Interface ebm-papst circuit

48 Condensing boiler technology · Edition 2019 - 03


Interface 38  115/230 VAC

1 UB +24 - 45VDC/15mA
UB ripple ±3.5%

counter 2.2K 12K


I sink
loop controller max. 1mA 1
2 tacho output 3
alarm device 3 pulses per revolution 1K 4 2

RPM monitor 12V

3 D.N.C.

EC radial blowers
12K

4 PWM 2 - 6kHz 1 3
12K input signal - square pulse 1K 6K8 4
2
PWM-Low ->fan off
PWM-High -> fan on
input open -> max. speed
5 GND
start-up -> PWM > 25%

ST2

customer circuit - example Interface ebm-papst circuit

Interface 39  115/230 VAC

+15V
+16...45VDC
1 max. ripple +/-3.5%

counter
12K

tacho output
loop controller 3 pulses per revolution 1
2 3
1K 4 2
alarm device
+15V
12V

RPM monitor
47K

speed control 0-10V 100K 0-10V


3 DC
PWM
+15V 0-100%
1
13V

3
12K

10K

2 4
PWM 1-6 kHz 10K PWM
4
12K input signal - square pulse PWM
PWM-Low - fan off
PWM-High - fan on
20K
15V

input open -> max. speed


5 GND

speed control speed control speed control


Gasmodul - interface with open collector 0-10V

Start -> PWM > 10% Start -> PWM > 10% 10V -> n=max
1V -> n=min
n=min -> PWM > 7% n=min -> PWM > 7%
> 0.6V -> Start
Stop -> PWM = 0% Stop -> PWM = 0% < 0.1V -> Stop ST2

customer circuit - example interface ebm-papst circuit

Condensing boiler technology · Edition 2019 - 03 49


Electrical
interfaces

Further types available on request.

Interface 61 3~ 380-480 VAC, 50/60 Hz

Uin 1 +18...43VDC
counter

15K
loop controller

2 tacho output 1K
alarm device

12V
5 pulses per revolution

RPM monitor

3 N.C.
+20V
12k
EC radial blowers

18K
PWM 1-6 kHz
PWM
12k 4
PWM input signal - square pulse 0-5V
1K
PWM-Low - fan off DC
PWM-High - fan on
input open -> max. speed 12K

15V
5 GND
GND

speed control
Gasmodule - interface RSA
6 RSA

galvanic isolation
RSB
7 RSB connection via terminal block
recommended wire size 0.5 - 1mm2
Start -> PWM > 12%
n=min -> PWM > 10%
speed control
Stop-> PWM < 8% Modbus ST2

customer circuit interface ebm-papst circuit

Interface 63 3~ 380-480 VAC, 50/60 Hz

Uin 1 +18...43VDC
no simultaneous usage with PWM

counter
15K

loop
controller
interface recommended!

2 tacho output 1K
alarm device 5 pulses per resolution
12V

RPM
monitor 0-10V
DC
3 speed control 0-10V * 47K 0-5V
+20V DC
12k

47K
18K

PWM 1-6 kHz


PWM
12k 4 input signal -
PWM square pulse 1K 0-5V
DC
PWM - Low - fan off
PWM - High - fan on
12K

15V

input open -> max. speed


GND 5 GND

RSA
6 RSA
galvanic isolation

RSB +10V
7 RSB

UOut
8 UOut 10VDC
speed control speed speed
Gasmodule - control control voltage output
interface 0V - 10V Modbus
10V -> n=max connection via terminal block
Start -> PWM > 10%
n=min -> PWM > 8% 2V -> n=min 10VDC OUTPUT
>1.6V -> Start recommended wire size 0.5 - 1mm²
Stop -> PWM < 5% <1.0V -> Stop ST2

customer circuit interface ebm-papst circuit


* for use of 0-10V interface, bridge PWM to GND

50 Condensing boiler technology · Edition 2019 - 03


Interface 64 3~ 380-480 VAC, 50/60 Hz

NO NO

2A / 250VAC / AC1
Alarm Relay
COM COM

NC NC
ST2
Uin +16...45V
RSA RSA RSA

EC radial blowers
RSB 24V
RSB RSB

68K
12k

PWM 1-10 kHz


PWM input signal - 4K7 4K7
12k square pulse
PWM - Low - fan off
PWM PWM - High- fan on
input open->

15V
max. speed

7V
UOut
+10V +10V

GND GND
GND
4K7

0-10V speed control 0-10V * 4K7


input open ->
counter max. speed 24V

15V
12K
no simultaneous usage with 0-10V interface

no simultaneous usage with PWM interface

loop controller
TACHO TACHO 820
alarm device

RPM monitor
HALL
UOut
12V

+20V +20V
galvanic isolation

0V

GND GND
TACHO
RSB PWM

+10V +20V
GND GND

speed speed voltage output voltage output tacho output


COM
NO

speed control control control


NC

connection via terminal block


0-10V

Gasmodule - interface
RSA

0V - 10V Modbus

Start -> PWM > 10% 10V -> n=max 10VDC 20VDC 4 pulses per resolution ST3 ST2
2V -> n=min OUTPUT OUTPUT
n=min -> PWM > 7% >1.6V -> Start (±10%) (±20%) 12VDC(±10%) / max.10mA /
Stop -> PWM > 5% <1.0V -> Stop max.10mA max.50mA Impedace 1k ST3
customer circuit interface ebm-papst circuit
* for use of 0-10V interface, bridge PWM to GND

Condensing boiler technology · Edition 2019 - 03 51


Gas valves

Our gas valves are mainly used in condensing unit The offset (zero point shift) can be configured at the
applications for domestic heating technology in the servo controller. At the same time, the desired gas
low-to-medium output range. They ensure precise quantity is adjusted using an integrated flow control
air-gas ratio adjustment. element. Depending on the design, reference pressure
can be connected to the servo controller if required.
The G20 D01 and G15/G20 E01 gas valves are suitable
for condensing units with pneumatic composite The G15/G20 F01,G32 F01 and G40 F01 gas valves are
controls. Regardless of the suction pressure generated suitable for condensing units with electronic composite
by the premix blower, these gas valves always keep the controls. Regardless of gas quality and any pressure
offset pressure at zero and compensate for pressure fluctuations in the supply network, these gas valves
fluctuations in the supply network as well. regulate the constant air-gas ratio without relying on
mechanical gas valve settings.
Gas valves

Mounting position
Solenoid at any position between vertical and horizontal
– but not upside down

52 Condensing boiler technology · Edition 2019 - 03


Type examination certificate for Type examination certificate in accordance
North America (USA and Canada): with EC Gas ­Appliances Directive:
Master Contract No. 172723 CE 0085CM0036 (product ID number)
Applicable standards Applicable standards:
ANSI Z21.78 2010 / CSA 6.20 2010: – EN126:2012 06: Multifunctional controls for gas
Combination Gas Controls for gas appliances burning appliances
– EN13611:2007 + A2:2011: Safety and control devices
Approvals exist for the chief gas consuming
for gas burners and gas burning appliances – General
countries.
requirements
– EN161:2012 08: Automatic shut-off valves for gas
burners and gas appliances
– EN88-1:2011: Pressure regulators and associated safety
devices for gas appliances – Part 1: Pressure regulators
for inlet pressures up to and including 50 kPa

Gas valves

Additional notes
– Work on the gas valve may be performed by authorised
specialists only.
– Please be sure to observe the corresponding installation instructions.
– Corresponding documents with safety instructions are
available upon request or on the Internet.

Condensing boiler technology · Edition 2019 - 03 53


Gas valves pneumatic gas air ratio control system
G15/G20 E01

Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
65 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature: 0°C to 60°C
■■ Permitted storage temperature: -25°C to 70°C
■■ Offset correction: +/- 20 Pa
■■ Input (gas connection):
External thread G3/4 or G1/2 (EN ISO 228) or
Mehr at
More unter www.ebmpapst.com
4 x M4-mounting holes (optional)
■■ Output:
ebm-papst proprietary quick release
■■ Safety valve:
Coaxial design: Valve class B/C as per EN161
Electrical data
■■ Designed for protection class I
Capacity curve – GXXE01-BCXCS ■■ Electrical connection:
Connector shell with 4.20mm grid
100
80
Gas valves

60
50 Recommended operating range
40

30
∆p [mbar]

20

10
8

6
5
4

2
Conditions
Conditions: +15°C/
+ ° C / 59°F,
 °F, pp= 1013mbar
=   mbar

0,1 0,2 0,3 0,4 0,5 0,6 0,8 1 2 3 4 5 6 7 8 9 10 20


°Vn [m3/h] Luft / Air (dv = 1,00)

0,2 0,3 0,4 0,5 0,6 0,8 1 2 3 4 5 6 7 8 9 10 20 30


°Vn [m3/h] Erdgas / Natural gas (dv = 0,65)

54 Condensing boiler technology · Edition 2019 - 03


Gas valves G15/G20 E01

Nominal diameter
Max. input power

and closing time


(at Δp = 5mbar)

signal pressure
Rated voltage

shutoff valves
inlet pressure

Automatic
Maximum

Minimum
Flow rate

Opening
(EN161)
Type

V VA mbar m³/h Pa s
Nominal data
230 RAC 9.8 DN15/20 65 3.4 Class B/C -40 <1
120 RAC 9.8 DN15/20 65 3.4 Class B/C -40 <1
GXXE01-BCXCS 24 RAC 9.8 DN15/20 65 3.4 Class B/C -40 <1
24 DC 9.8 DN15/20 65 3.4 Class B/C -40 <1
22 DC 11.9 DN15/20 65 3.4 Class B/C -40 <1

Subject to change.

Gas valve

Type Weight
kg
GXXE01-BCXCS 0.57

Technical drawing Dimensions in mm

Ø31

Ø9
103.8

Gas valves
34

Ø54.5
Ø18

30.5

5.5
80 33.5
46 56
105.5
Ø5 50
.1 14.5
(2

x)

29
14.5
5.5





7.5 14
① Electrical connection 19
② Solenoid coil
③ Pressure test nipple P1
④ Pressure regulator offset adjustment
⑤ Pressure test nipple P2
⑥ Main flow throttle

Condensing boiler technology · Edition 2019 - 03 55


Gas valves pneumatic gas air ratio control system
G20 D01

Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
65 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature: 0°C to 60°C
■■ Permitted storage temperature: -25°C to 70°C
■■ Offset correction: +/- 20 Pa
■■ Input (gas connection):
4 x M5-mounting holes
More at www.ebmpapst.com
(hole spacing 36 mm)
■■ Output:
4 x M5-mounting holes
(hole spacing 36 mm)
■■ Safety valve: Valve class B/B as per EN161
Electrical data
■■ Designed for protection class I
Capacity curve – G20D01-BBXCS ■■ Electrical connection:
Connector shell with 5.08 mm grid
100
80
Gas valves

60
50 Recommended operating
recommended operating range range
40

30

20
∆p [mbar]

10
8

6
5
4

2
Bedingungen
Conditions + 15°C,
+15°C/ 59°F,1013 mbar, trocken
p= 1013mbar, dry

0,1 0,2 0,3 0,4 0,5 0,6 0,8 1 2 3 4 5 6 7 8 9 10 20


V° n [m3/h] Luft / Air (dv = 1,00)

0,2 0,3 0,4 0,5 0,6 0,8 1 2 3 4 5 6 7 8 9 10 20 30


V° n [m3/h] Erdgas / Natural gas (dv = 0,65)

56 Condensing boiler technology · Edition 2019 - 03


Gas valve G20 D01

Nominal diameter
Max. input power

and closing time


(at Δp = 5mbar)

signal pressure
Rated voltage

shutoff valves
inlet pressure

Automatic
Maximum

Minimum
Flow rate

Opening
(EN161)
Type

V VA mbar m³/h Pa s
Nominal data
230 RAC 2 x 12.5 DN20 65 5.3 Class B/B -40 <1
120 RAC 2 x 12.5 DN20 65 5.3 Class B/B -40 <1
G20D01-BBXCS
24 RAC 2 x 12.5 DN20 65 5.3 Class B/B -40 <1
24 DC 2 x 12.5 DN20 65 5.3 Class B/B -40 <1

Subject to change.

Gas valve

Type Weight
kg
G20D01-BBXCS 1.3

Technical drawing Dimensions in mm

59

Ø9
111.5

Gas valves
28

Ø54.5
36.5

40.5 41.8
105 83.6
57

① ③

⑥ ④
⑦ ⑤

① Pressure regulator offset adjustment


② Servo regulator
③ Electrical connection
④ Solenoid coil
⑤ Pressure test nipple P1
⑥ Main flow throttle
⑦ Pressure test nipple P2

Condensing boiler technology · Edition 2019 - 03 57


Gas valves electronic gas air ratio control system
G15/G20 F01

Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
60 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature:
-15°C to 70°C
■■ Permitted storage temperature:
-25°C to 70°C
■■ Input (gas connection):
More at www.ebmpapst.com
External thread G3/4 oder G1/2 (EN ISO 228)
■■ Output:
ebm-papst proprietary quick release
■■ Safety valves:
Coaxial design: Valve class B/C as per EN161
Electrical data
■■ Designed for protection class I
Capacity curve – GXXF01-BCXCS ■■ Electrical connection:
Connector shell with 4.20mm grid
100
Gas valves

Recommended operating range


empfohlener Arbeitsbereich
∆p [mbar]

10

F01 - 8 mm
F01 - 12 mm

Conditions +15°C/ 59°F,


Bedingungen: 15° C, p=1013 mbar
p= 1013mbar
1

0,01 0,1 1 10
V° n [m3/h] Luft / Air

0,013 0,134 1,342 13,423


V° n [m3/h] Erdgas / Natural gas

58 Condensing boiler technology · Edition 2019 - 03


Gas valves G15/G20 F01

Nominal diameter

nominal diameter

nominal diameter
Max. input power

and closing time


(at Δp = 5mbar)

(at Δp = 5mbar)
Stepper motor

Stepper motor
Rated voltage

shutoff valves
inlet pressure

module with

module with

Automatic
Maximum

Flow rate

Flow rate

Opening
(EN161)
12 mm
8 mm
Type

V VA mbar m³/h m³/h s


Nominal data
230 RAC 9.8 DN15/20 60 2.1 2.9 Class B/C <1
120 RAC 9.8 DN15/20 60 2.1 2.9 Class B/C <1
GXXF01-BCXCS 24 RAC 9.8 DN15/20 60 2.1 2.9 Class B/C <1
24 DC 9.8 DN15/20 60 2.1 2.9 Class B/C <1
22 DC 11.9 DN15/20 60 2.1 2.9 Class B/C <1

Subject to change.

Gas valve

Type Weight
kg
GXXF01-BCXCS 0.47

Technical drawing Dimensions in mm

105.5 62.81

88.7
24.8
21.5 20.8

Gas valves
Ø18

24.1

5.9 11.8 37.9


82.3

100
67.75
32.5 11.5

⑤ ①

29


25


① Electrical connection safety valve
② Pressure test nipple
③ G 3/4" or G1/2" ISO 228-1
④ Solenoid coil
⑤ Electrical connection stepper motor

Condensing boiler technology · Edition 2019 - 03 59


Gas valves electronic gas air ratio control system
G32 F01

Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
I + II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
60 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature:
-15°C to 60°C
■■ Permitted storage temperature:
-25°C to 70°C
■■ Input (gas connection):
More at www.ebmpapst.com
external thread G 1 1/4 (EN ISO 228)
■■ Output: Flange connection 4 x mounting holes
for self-tapping screw (nominal diameter
5 mm); hole spacing 52.33 mm
■■ Safety valves:
Coaxial design: Valve class B/C in accordance
with EN161
■■ Interface to mechanical pressure monitor port:
Capacity curve – G32F01-CBXCS Inlet pressure; central chamber pressure
■■ Pressure test nipple: Inlet and outlet pressure
100
Electrical data
■■ Designed for protection class I
Gas valves

Recommended
recommended operating range
operating range ■■ Electrical connection:
Safety module: suitable for connector housing
with pitch 4.20mm (e.g., Stocko STO-FIT
System, EH 705-103; Würth series
∆p [mbar]

WR-MPC4, item no. 649 003 013 322)


10 ■■ Stepper motor module:


Connector housing Stocko-Grid MH790-06-001

Conditions Bedingungen:
+15°C/ 59°F, 15° C,p= 1013mbar
p=1013 mbar
1

0,1 1 10 100
V° n [m3/h] Luft / Air

0,134 1,342 13,423 134,231


V° n [m3/h] Erdgas / Natural gas

60 Condensing boiler technology · Edition 2019 - 03


Gas valve G32 F01

Nominal diameter
Max. input power

and closing time


(at Δp = 5mbar)
Rated voltage

shutoff valves
inlet pressure

Automatic
Maximum

Flow rate

Opening
(EN161)
Type

V VA mbar m³/h s
Nominal data
230 RAC 17 DN32 60 9.2 Class C/B <1
G32F01-CBXCS 120 RAC 17 DN32 60 9.2 Class C/B <1
24 DC 17 DN32 60 9.2 Class C/B <1

Subject to change.

Gas valve

Type Weight
kg
G32F01-CBXCS 1.55

Technical drawing Dimensions in mm

137.5
61.5 15
20

Gas valves
115
65

35

65 176

① ②

③ ⑤ ④ ③
① 1 1/4" B ISO 228-1
② Electrical connection safety valve
③ Pressure test nipple
④ Electrical connection control valve
⑤ Solenoid coil

Condensing boiler technology · Edition 2019 - 03 61


Gas valves electronic gas air ratio control system
G40 F01

Material/surface
■■ Housing: Aluminium
Mechanical data
■■ Degree of protection:
IP40 in combination with a suitable plug
■■ Permitted gas families:
I + II + III (in accordance with EN 437)
■■ Maximum inlet pressure:
60 mbar (CE), 0.5 psi (CSA)
■■ Permitted ambient temperature:
-15°C to 60°C
■■ Permitted storage temperature:
-25°C to 70°C
■■ Input (gas connection):
Mehr at
More unter www.ebmpapst.com
Flange connection 4 x mounting holes for
self-tapping screw (nominal diameter 6 mm);
hole spacing 52.33 mm. Input flange 1 ½”
optional
■■ Output: Flange connection 4 x mounting holes
for self-tapping screw (nominal diameter
6 mm); hole spacing 52.33 mm
■■ Safety valve:
Capacity curve – G40F01-BBXCS Coaxial design: External thread B/B as per
EN161
100 ■■ Interface to mechanical pressure monitor port:
Inlet pressure; central chamber pressure for
VPS (optional)
Gas valves

Recommended operating
recommended operating range range ■■ Pressure test nipple:
Inlet and outlet pressure
Electrical data
■■ Designed for protection class I
∆p [mbar]

■■ Electrical connection:
10
Suitable for connector housing with pitch
4.20mm (e.g., Stocko STO-FIT System,
EH 705-103; Würth WR-MPC4 series,
item no. 649 003 013 322)
■■ Stepper motor module:
Connector housing Stocko-Grid MH790-06-001

Conditions +15°C/1559°F,
Bedingungen: p= 1013mbar
° C, p=1013 mbar
1

0,1 1 10 100
V° n [m3/h] Luft / Air

0,134 1,342 13,423 134,231


V° n [m3/h] Erdgas / Natural gas

62 Condensing boiler technology · Edition 2019 - 03


Gas valve G40 F01

Nominal diameter
Max. input power

and closing time


(at Δp = 5mbar)
Rated voltage

shutoff valves
inlet pressure

Automatic
Maximum

Flow rate

Opening
(EN161)
Type

V VA mbar m³/h s
Nominal data
230 RAC 22 DN40 60 15.5 Class B/B <1
G40F01-BBXCS 120 RAC 22 DN40 60 15.5 Class B/B <1
24 DC 22 DN40 60 15.5 Class B/B <1

Subject to change.

Gas valve

Type Weight
kg
G40F01-BBXCS 1.97

Technical drawing Dimensions in mm

180.5
133
50.5
15
14

Gas valves
126
72
38.6

② ④ ③ ②
① Electrical connection safety valve
② Pressure test nipple
③ Electrical connection control valve
④ Solenoid coil

Condensing boiler technology · Edition 2019 - 03 63


Burner control units

We supply the right electronics for controlling ignition,


performance regulation and monitoring the function of
the condensing boiler as well as user interfaces needed
for conveniently controlling central heating and hot water.
The burner control can also be combined with other
modules and provide control for system regulation, For Commercial Applications
for example cascade operation. – For commercial boilers up to 2MW
Our product range, consisting of tried-and-tested hardware – Integrated cascade control
and software, enables reliable operating performance and – Flexibility to configure many systems:
short development cycles. The versatile software preset appliance types
architecture enables easy interface integration. In addition, – Configurable inputs and outputs
as with our blowers, we value having the lowest possible – Integrated low water cutoff
energy consumption. – Many modes for CH and DHW
control units
Burner

User Interface
– Touch screen: communication with boiler control via Modbus
– Ethernet connection to web server
– Graphical LCD interface for boiler status,
operation and configuration
– Password-protected user levels
– Includes diagnostics software and a smart app for remote control

64 Condensing boiler technology · Edition 2019 - 03


For Residential Applications
– Smart control for various appliances up to 50kW:
water heaters (with/without tank) and residential combi boilers
– Also applicable as general burner control
– Optional Modbus communication
– Available as all-in-one kit

control units
Burner

User Interface
– On-board HMI: Reset button and status LED
– Advanced external display option

Condensing boiler technology · Edition 2019 - 03 65


Commercial range
Packages

■■ Applicable for commercial boilers up to 2 MW


■■ Configurable input/output functions
Commercial ■■ Multiple heat demand options
(on/off, OpenTherm, 0-10V)
■■ Internal/external spark igniter or
hot-surface igniter
■■ Primary safeguard functions
■■ Extra safety- and smart control functions

Commercial Plus Residential Plus

Diagnostics software
Cascade operation

User interface
Power supply

Touch screen
Dimensions

Smart app
Ethernet
Modbus
AL-BUS
control

V AC mm
Packages
Commercial Plus 120/230 212×152×49 8 boilers × 8 modules Y 900PB Display Y Y Y Y Y
Commercial 120/230 212×152×49 max. 16 boilers N 900PB Display Y Y optional Y Y
Residential Plus 120/230 212×152×49 settings only N 900LB Display Y N N Y Y

Commercial Plus with integrated cascade control:


Up to 8 boilers x 8 modules (1 managing boiler and max. 7 dependent boilers).
control units
Burner

Managing boiler

900PB Display

Dependent boiler 1

Dependent boiler 7

Managing boiler: M1, M2, etc. 900TS Touchscreen


Dependent boiler: D1, D7, etc.

66 Condensing boiler technology · Edition 2019 - 03


Residential range
Packages

■■ Smart control for various appliances:


water heaters (with/without tank) and
residential combi boilers
■■ Also applicable as general burner control
■■ Flexible mounting options
■■ On-board user interface or advanced
external display
Residential Combi Boiler ■■ Optional Modbus communication

(Tankless) Water Heater Smart Burner

Diagnostics software
Dimensions control

On-board HMI

User interface
Power supply

Smart app
Modbus
AL-BUS

V AC mm
Packages
Tankless Water Heater 120/230 203×114×50 N 900LB Display Y N Y Y
Water Heater 120/230 203×114×50 N 900LB Display Y N Y Y
Residential Combi Boiler 120/230 203×114×50 N 900LB Display Y N Y Y
Smart Burner 120/230 203×114×50 Y Y Y Y Y

control units
Burner

900LB Display

Condensing boiler technology · Edition 2019 - 03 67


ebm-papst in Germany

Berlin Heilbronn / Heidelberg Ulm


Dipl.-Ing. (TH) Jens Duchow Wolfgang Richter M.Sc. Reinhard Sommerreißer
Händelstraße 7 Büttelsbergweg 18 Einsteinstraße 7a
16341 Panketal 97980 Bad Mergentheim-Rengershausen 86674 Baar / Schwaben
GERMANY GERMANY GERMANY
Phone +49 30 944149-62 Phone +49 7937 32200-33 Phone +49 8276 5899-775
Fax +49 30 944149-63 Fax +49 7938 81-110 Fax +49 7938 81-110
Jens.Duchow@de.ebmpapst.com Wolfgang.Richter@de.ebmpapst.com Reinhard.Sommerreisser@de.ebmpapst.com

Bielefeld Kassel Distributors


Dipl.-Ing. (FH) Wolf-Jürgen Weber Dipl.-Ing. (FH) Ralph Brück
Niehausweg 13 Hoherainstraße 3 b Frankfurt
33739 Bielefeld 35075 Gladenbach R.E.D. Handelsgesellschaft mbH
GERMANY GERMANY Gutenbergstraße 3
Phone +49 5206 91732-31 Phone +49 6462 4071-10 63110 Rodgau - Jügesheim
Fax +49 5206 91732-35 Fax +49 6462 4071-11 GERMANY
Wolf-Juergen.Weber@de.ebmpapst.com Ralph.Brueck@de.ebmpapst.com Phone +49 6106 841-0
Fax +49 6106 841-111
Dortmund Koblenz info@red-elektromechanik.de
Dipl.-Ing. (FH) Hans-Joachim Pundt Winfried Schaefer www.red-elektromechanik.de
Auf den Steinern 3 Hinter der Kirch 10
59519 Möhnesee-Völlinghausen 56767 Uersfeld Hamburg
GERMANY GERMANY Breuell + Hilgenfeldt GmbH
Phone +49 2925 800-407 Phone +49 2657 16-96 Oststraße 96
Fax +49 2925 800-408 Fax +49 2657 16-76 22844 Norderstedt
Hans-Joachim.Pundt@de.ebmpapst.com Winfried.Schaefer@de.ebmpapst.com GERMANY
Phone +49 40 538092-20
Frankfurt Munich Fax +49 40 538092-84
Dipl.-Ing. Christian Kleffmann Dipl.-Wirt.-Ing. (FH) Jens Peter info@breuell-hilgenfeldt.de
Dr.-Hermann-Krause-Straße 23 Landsbergerstraße 14
63452 Hanau 86932 Pürgen Munich
GERMANY GERMANY A. Schweiger GmbH
Phone +49 6181 1898-12 Phone +49 7971 91909-49 Ohmstraße 1
Fax +49 6181 1898-13 Fax +49 8196 99877-55 82054 Sauerlach
Christian.Kleffmann@de.ebmpapst.com Jens.Peter@de.ebmpapst.com GERMANY
Phone +49 8104 897-0
Halle Nuremberg Fax +49 8104 897-90
Dipl.-Ing. (TU) Michael Hanning Dipl.-Wirt.-Ing. (FH) Axel Resch info@schweiger-gmbh.de
Lercheneck 4 Dr.-August-Koch-Str. 1 www.schweiger-gmbh.com
06198 Salzatal / OT Lieskau 91639 Wolframs-Eschenbach
GERMANY GERMANY (1 to 5 pieces)
Phone +49 345 55124-56 Phone +49 9875 9783-170
Agents

Fax +49 345 55124-57 Fax +49 9875 9783-171 North


Michael.Hanning@de.ebmpapst.com Axel.Resch@de.ebmpapst.com Breuell + Hilgenfeldt GmbH
Oststraße 96
Hamburg Offenburg 22844 Norderstedt
Ingenieurbüro Breuell GmbH Dipl.-Ing. (FH) Ralf Braun GERMANY
Ing. Dirk Kahl Hubeneck 21 Phone +49 40 538092-20
Elektroingenieur 77704 Oberkirch Fax +49 40 538092-84
Oststraße 96 GERMANY info@breuell-hilgenfeldt.de
22844 Norderstedt Phone +49 7802 9822-52
GERMANY Fax +49 7802 9822-53 South
Phone +49 40 538092-19 Ralf.Braun@de.ebmpapst.com HDS Ventilatoren Vertriebs GmbH
Fax +49 40 538092-84 Glaswiesenstraße 1
Kahl@breuell-hilgenfeldt.de Stuttgart 74677 Dörzbach
Dipl.-Ing. (FH) Rudi Weinmann GERMANY
Hindenburgstraße 100/1 Phone +49 7937 80355-20
73207 Plochingen Fax +49 7937 80355-25
GERMANY info@hds-gmbh.net
Phone +49 7153 9289-80 www.hds-gmbh.net
Fax +49 7153 9289-81
Rudi.Weinmann@de.ebmpapst.com

fan agent compact fan agent motor specialist motor agent

68 Condensing boiler technology · Edition 2019 - 03


ebm-papst in Europe

Europe Cyprus Greece


Helcoma HELCOMA
Austria E. Rota and Co. OE HELLAS IKE
ebm-papst Motoren & Ventilatoren GmbH Davaki 65 65, Davaki street
Straubingstraße 17 17672 Kallithea-Attiki 17672 Kallithea-Attiki
4030 Linz GREECE GREECE
AUSTRIA Phone +30 210 9513-705 Phone +30 210 9513-705
Phone +43 732 321150-0 Fax +30 210 9513-490 Fax +30 210 9513-490
Fax +43 732 321150-20 contact@helcoma.gr contact@helcoma.gr
info@at.ebmpapst.com www.helcoma.gr www.helcoma.gr
www.ebmpapst.at
Czech Republic / Slovakia Hungary
Belarus ebm-papst CZ s.r.o. ebm-papst Industries Kft.
ebm-papst Bel AgmbH Kaštanová 34a Ezred u. 2.
4th Montazhnikov side street 620 00 Brno 1044 Budapest
House 6, Office 332 CZECH REPUBLIC HUNGARY
BY-220019 Minsk Phone +420 544 502-411 Phone +36 1 8722-190
BELARUS Fax +420 547 232-622 Fax +36 1 8722-194
Phone +375 17 2015216 info@ebmpapst.cz office@hu.ebmpapst.com
Fax +375 17 2015216 www.ebmpapst.cz
info@by.ebmpapst.com Iceland
www.ebmpapst.by Denmark RJ Engineers
ebm-papst Denmark ApS Stangarhyl 1a
Belgium Vallensbækvej 21 110 Reykjavik
ebm-papst Benelux B.V. 2605 Brøndby ICELAND
Sales office Belgium-Luxemburg DENMARK Phone +354 567 8030
Romeinsestraat 6/0101 Phone +45 43 631111 Fax +354 567 8015
Research Park Haasrode Fax +45 43 630505 rj@rj.is
3001 Heverlee-Leuven mail@dk.ebmpapst.com www.rj.is
BELGIUM www.ebmpapst.dk
Phone +32 16 396-200 Ireland
Fax +32 16 396-220 Estonia ebm-papst UK Ltd.
info@be.ebmpapst.com ebm-papst Oy, Eesti Filiaal Chelmsford Business Park
www.ebmpapst.be Kesk tee 21 Chelmsford Essex CM2 5EZ
Aaviku küla, Jüri Tehnopark UNITED KINGDOM
Bulgaria 75301 Rae Vald, Harjumaa Phone +44 1245 468555
ebm-papst Romania S.R.L. ESTONIA Fax +44 1245 466336
Str. Tarnavei No. 20 Phone +372 65569-78 sales@uk.ebmpapst.com
500327 Brasov www.ebmpapst.ee www.ebmpapst.co.uk
ROMANIA
Phone +40 268 331859 Finland AuBren Limited
Fax +40 268 312805 ebm-papst Oy Portlaoise Business & Technology Park
dudasludovic@xnet.ro Puistotie 1 Mountrath Road Agents
02760 Espoo Portlaoise, Co. Laois
Croatia FINLAND IRELAND
ebm-papst Industries Kft. Phone +358 9 887022-0 Phone +353 57 8664343
Ezred u. 2. Fax +358 9 887022-13 Fax +353 57 8664346
1044 Budapest mailbox@ebmpapst.fi sales@ie.aubren.com
HUNGARY www.ebmpapst.fi www.aubren.com
Phone +36 1 8722-190
Fax +36 1 8722-194 France Italy
office@hu.ebmpapst.com ebm-papst sarl ebm-papst Srl
Parc d’Activités Nord Via Cornaggia 108
1 rue Mohler – BP 62 22076 Mozzate (Co)
67212 Obernai Cedex ITALY
FRANCE Phone +39 0331 836201
Phone +33 3 88 66 88 03 Fax +39 0331 821510
info@ebmpapst.fr info@it.ebmpapst.com
www.ebmpapst.fr www.ebmpapst.it

fan agent compact fan agent motor specialist motor agent

Condensing boiler technology · Edition 2019 - 03 69


ebm-papst in Europe

Macedonia Romania Switzerland


ebm-papst Industries Kft. ebm-papst Romania S.R.L. ebm-papst AG
Ezred u. 2. Str. Tarnavei Nr. 20 Rütisbergstrasse 1
1044 Budapest 500327 Brasov 8156 Oberhasli
HUNGARY ROMANIA SWITZERLAND
Phone +36 1 8722-190 Phone +40 268 331859 Phone +41 44 73220-70
Fax +36 1 8722-194 Fax +40 268 312805 Fax +41 44 73220-77
office@hu.ebmpapst.com dudasludovic@xnet.ro verkauf@ebmpapst.ch
www.ebmpapst.ch
Netherlands Russia
ebm-papst Benelux B.V. ebm-papst Rus GmbH Turkey
Polbeemd 7 - 5741 TP Beek en Donk Olimpiyskiy prospect 29A, office 418 Akantel Elektronik San. Tic. LTD. Sti.
P.O. Box 140 - 5740 AC Beek en Donk 141006 Mytistschi, Oblast Moskau Atatürk Organize Sanayi
NETHERLANDS RUSSIA Bölgesi 10007 SK. No.:6
Phone +31 492 502-900 Phone +7 495 9807524 35620 Cigli-Izmir
Fax +31 492 502-950 Fax +7 495 5140924 TURKEY
verkoop@nl.ebmpapst.com info@ebmpapst.ru Phone +90 232 3282090
www.ebmpapst.nl www.ebmpapst.ru Fax +90 232 3280270
akantel@akantel.com.tr
ebm-papst Heating Systems B.V. ebm-papst Ural GmbH www.ebmpapst.com.tr
Van Veldekekade 360 Posadskaja-Strasse, 23(E), 3
5216 KT 's-Hertogenbosch 620102 Ekaterinburg Ukraine
NETHERLANDS RUSSIA ebm-papst Ukraine LLC
Phone +31 73 648 89 00 Phone +7 343 2338000 Lepse Boulevard, 4, Building 21
Fax +31 73 648 89 11 Fax +7 343 2337788 03067 Kiev
info@ebmpapst-hs.nl Konstantin.Molokov@ru.ebmpapst.com UKRAINE
www.ebmpapst-hs.nl www.ebmpapst.su Phone +38 044 2063091
Fax +38 044 2063091
Norway Serbia & Montenegro mail@ebmpapst.ua
ebm-papst AS ebm-papst Industries Kft. www.ebmpapst.ua
P.B. 173 Holmlia Ezred u. 2.
1203 Oslo 1044 Budapest United Kingdom
NORWAY HUNGARY ebm-papst UK Ltd.
Phone +47 22 763340 Phone +36 1 8722-190 Chelmsford Business Park
Fax +47 22 619173 Fax +36 1 8722-194 Chelmsford Essex CM2 5EZ
mailbox@ebmpapst.no office@hu.ebmpapst.com UNITED KINGDOM
www.ebmpapst.no Phone +44 1245 468555
Spain Fax +44 1245 466336
Poland ebm-papst Ibérica S.L. sales@uk.ebmpapst.com
ebm-papst Polska Sp. z o.o. Avda. del Sistema Solar, 29 www.ebmpapst.co.uk
ul. Annopol 4A 28830 San Fernando de Henares (Madrid)
03236 Warszawa SPAIN ebm-papst Automotive & Drives (UK) Ltd.
Agents

POLAND Phone +34 91 6780894 The Smithy


Phone +48 22 6757819 Fax +34 91 6781530 Fidlers Lane
Fax +48 22 6769587 ventas@ebmpapst.es East Ilsley, Berkshire RG20 7LG
office@ebmpapst.pl www.ebmpapst.es UNITED KINGDOM
www.ebmpapst.pl Phone +44 1635 2811-11
Sweden Fax +44 1635 2811-61
Portugal ebm-papst AB A&Dsales@uk.ebmpapst.com
ebm-papst (Portugal), Lda. Äggelundavägen 2 www.ebmpapst-ad.com
Centro Empresarial de Alverca 17562 Järfälla
Rua de Adarse, Vale D’Ervas SWEDEN
Corpo D / Fracção 3 Phone +46 10 4544400
2615-178 Alverca do Ribatejo Fax +46 8 362306
PORTUGAL info@ebmpapst.se
Phone +351 218 394 880 www.ebmpapst.se
Fax +351 218 394 759
info@pt.ebmpapst.com
www.ebmpapst.pt

fan agent compact fan agent motor specialist motor agent

70 Condensing boiler technology · Edition 2019 - 03


ebm-papst in America & Africa

America USA Africa


ebm-papst Inc.
Argentina P.O. Box 4009 South Africa
ebm-papst Argentina S.A. 100 Hyde Road ebm-papst South Africa (Pty) Ltd.
Parque Industrial Canning Etapa II - Nave Farmington, CT 06034 P.O. Box 3124
61A, Perito Moreno 845, Canning (1804), UNITED STATES 1119 Yacht Avenue
Buenos Aires Phone +1 860 674-1515 2040 Honeydew
ARGENTINA Fax +1 860 674-8536 SOUTH AFRICA
Phone +54 11 46576135 sales@us.ebmpapst.com Phone +27 11 794-3434
Fax +54 11 46572092 www.ebmpapst.us Fax +27 11 794-5020
ventas@ar.ebmpapst.com info@za.ebmpapst.com
www.ebmpapst.com.ar ebm-papst Inc. www.ebmpapst.co.za
Automotive & Drives Business Unit
Brazil 3200 Greenfield Road, Suite 130
ebm-papst Motores Ventiladores Ltda. Dearborn, MI 48120
Av. José Giorgi, 301 Galpões B6+B7 UNITED STATES
Condominio Logical Center Phone +1 313 406-8080
06707-100 Cotia - São Paulo Fax +1 313 406-8081
BRAZIL automotive@us.ebmpapst.com
Phone +55 11 4613-8700 www.ebmpapst-automotive.us
Fax +55 11 4777-1456
vendas@br.ebmpapst.com
www.ebmpapst.com.br

Canada
ebm-papst Canada Inc.
419 King Street West, Suite 603A
Oshawa, ON, L1J2K5
CANADA
Phone +1 905 420-3533
Fax +1 905 420-3772
sales@ca.ebmpapst.com
www.ebmpapst.ca

Mexico
ebm Industrial S. de R.L. de C.V.
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
Mexico 05120, D.F.
MEXICO
Phone +52 55 3300-5144
Fax +52 55 3300-5243
sales@mx.ebmpapst.com Agents
www.ebmpapst.com.mx

fan agent compact fan agent motor specialist motor agent

Condensing boiler technology · Edition 2019 - 03 71


ebm-papst in Asia

Asia Japan Taiwan


ebm-papst Japan K.K. ETECO Engineering & Trading Corp.
China Attend on Tower 13F 10F-I, No. 92, Teh-Wei Str.
ebm-papst Ventilator (Shanghai) Co., Ltd. Shinyokohama 2-8-12, Kohoku-ku Tsow-Inn District, Kaohsiung
No. 418, Huajing Road 222-0033 Yokohama-City, Kanagawa TAIWAN
WaiGaoQiao Free Trade Zone JAPAN Phone +886 7 557-4268
No. 2001, Yang Gao (N) Road Phone +81 45 47057-51 Fax +886 7 557-2788
200131 Shanghai Fax +81 45 47057-52 eteco@ms22.hinet.net
P.R. of CHINA info@jp.ebmpapst.com www.ebmpapst.com.tw
Phone +86 21 5046-0183 www.ebmpapst.jp
Fax +86 21 5046-1119 Thailand
sales@cn.ebmpapst.com Korea ebm-papst Thailand Co., Ltd.
www.ebmpapst.com.cn ebm-papst Korea Co. Ltd. 99/9 Moo 2, Central Chaengwattana Tower
A-13F, Doosan The Land Tower 8th Floor, Room 801-802
Hong Kong 152, Magokseo-ro Chaengwattana Road Bangtarad, Pakkret
ebm-papst Hong Kong Ltd. Gangseo-gu 11120 Nonthaburi
Room 17E, MG Tower Seoul 07788 THAILAND
133 Hoi Bun Road, Kwun Tong KOREA Phone +66 2 8353785-7
Hong Kong Phone +82 2 366213-24 Fax +66 2 8353788
P.R. of CHINA Fax +82 2 366213-26 salesdept@th.ebmpapst.com
Phone +852 2145-8678 info@kr.ebmpapst.com
Fax +852 2145-7678 www.ebmpapst.co.kr United Arab Emirates
info@hk.ebmpapst.com ebm-papst Middle East FZE
Malaysia PO Box 17755
India ebm-papst Malaysia Jebel Ali Free Zone / FZS1 / AP05
ebm-papst India Pvt. Ltd. Representative Office Dubai
26/3, G.N.T. Road, Erukkencherry No. 16-1, Jalan Putra Mahkota 7/5A UNITED ARAB EMIRATES
Chennai-600118 Putra Heights Phone +971 4 88608-26
INDIA Selangor Darul Ehsan Fax +971 4 88608-27
Phone +91 44 25372556 47650 Subang Jaya info@ae.ebmpapst.com
Fax +91 44 25371149 MALAYSIA www.ebmpapst.ae
sales@in.ebmpapst.com Phone +60 3 5192-7688
www.ebmpapst.in Fax +60 3 5614-3078 Vietnam
salesdept@my.ebmpapst.com ebm-papst SEA Pte. Ltd.
Indonesia Representative Office (Vietnam)
ebm-papst Indonesia Philippines Floor M, Phuong Long Building,
Representative Office ebm-papst SEA Pte. Ltd. 506 Nguyen Dinh Chieu Street,
German Centre, 4th Floor, Suite 4470 Representative Office (Philippines) Ward 4, District 3,
Jl. Kapt. Subijono Dj. Bumi Serpong Damai Coherco Financial Tower Ho Chi Minh City, Vietnam
15321 Tangerang Trade Street Corner Investment Drive VIETNAM
INDONESIA Unit 1101 Madrigal Business Park Phone +84 28 3929 0699 / 3929 0670
Phone +62 21 5376250 1799 Ayala Alabang / Muntinlupa City Fax +84 28 3929 0669
Agents

Fax +62 21 5388305 Telefon: +63 02 8042747 salesdept@vn.ebmpapst.com


salesdept@id.ebmpapst.com Telefax: +63 02 8042757
salesdept@ph.ebmpapst.com
Israel
Polak Bros. Import Agencies Ltd. Singapore
9 Hamefalsim Street ebm-papst SEA Pte. Ltd.
Kiryat Arie, Petach-Tikva 49514 10 Changi South Street 2
ISRAEL #01-01/02
Phone +972 3 9100300 Singapore 486596
Fax +972 3 5796679 SINGAPORE
polak@polak.co.il Phone +65 65513789
www.polak.co.il Fax +65 68428439
salesdept@sg.ebmpapst.com

fan agent compact fan agent motor specialist motor agent

72 Condensing boiler technology · Edition 2019 - 03


ebm-papst in Oceania

Oceania

Australia
ebm-papst A&NZ Pty Ltd.
10 Oxford Road
Laverton North, Victoria, 3026
AUSTRALIA
Phone +61 3 9360-6400
Fax +61 3 9360-6464
sales@ebmpapst.com.au
www.ebmpapst.com.au

New Zealand
ebm-papst A&NZ Pty Ltd.
61 Hugo Johnston Drive, Unit H
Penrose 1061, Auckland
NEW ZEALAND
PO Box 112278,
Penrose 1642, Auckland
Phone +64 9 525-0245
Fax +64 9 525-0246
sales@ebmpapst.com.au
www.ebmpapst.com.au

Agents
fan agent compact fan agent motor specialist motor agent

2 Condensing boiler technology · Edition 2019 - 03


www.ebmpapst.com 37895-7-8811 · 2019-03 ·mc-2`

Condensing boiler technology


Printed in Germany

Condensing boiler technology · Edition 2019-03


Product Catalogue 2019-03

the engineer’s choice the engineer’s choice

ebm-papst ebm-papst
Landshut GmbH Heating Systems B.V.

Hofmark-Aich-Straße 25 Van Veldekekade 360


84030 Landshut 5216 KT ’s-Hertogenbosch
Germany Netherlands
Phone +49 871 707-0 Phone +31 73 648 89-00
Fax +49 871 707-465 Fax +31 73 648 89-11
info3@de.ebmpapst.com info@ebmpapst-hs.nl

Das könnte Ihnen auch gefallen