Code No.

P1776 (P0765) Overdrive solenoid


valve system

DIAGNOSIS PROCEDURE

STEP 1. M.U.T.-III diagnosis


code

Q. Are diagnosis codes P1774 (P0755) and


P1775 (P0760) set?

Go to Step 9.

Go to Step 2.

STEP 2. M.U.T.-III actuator test

Item 04: Overdrive solenoid valve


OK: Operating sound can be heard.
Q. Is the check result normal?

Intermittent malfunction (Refer to


GROUP 00 - How to Cope with Intermittent
Malfunction .)

Go to Step 3.
STEP 3. Connector check: B-15
A/T control solenoid valve
assembly connector

Check for the contact with terminals.

Q. Is the check result normal?

Go to Step 4.

Repair the defective


connector.

STEP 4. Measure the resistance


at A/T control solenoid valve
assembly connector B-15.

Disconnect the connector, and measure the


resistance between terminal No.5 and No.9
at the solenoid valve side.
OK: 2.7 - 3.4 Ω (A/T fluid temperature
20°C)

Q. Is the check result normal?

Go to Step 5.

Check the overdrive


solenoid valve and solenoid valve harness.
STEP 5. Measure the voltage at
A/T-ECU connector C-19.

(3)Measure the voltage


between A/T-ECU
connector C-19 terminal
No.14 and earth.
OK: 6 - 9 V

Q. Is the check result


normal?

Go to Step 8.

Go to Step 6.
STEP 6. Connector check: B-11
intermediate connector, C-19
A/T-ECU connector

Check for the contact with


terminals.

Q. Is the check result


normal?

Go to Step 7.

Repair the
defective connector.
STEP 7. Check the harness
between A/T control solenoid
valve assembly connector B-15
terminal No.5 and A/T-ECU
connector C-19 terminal No.14.

Check the output line for short


or open circuit.

Q. Is the check result


normal?

Go to Step 8.

Repair the wiring


harness.
STEP 8. M.U.T.-III actuator test

Item 04: Overdrive solenoid valve


OK: Operating sound can be heard.
Q. Is the check result normal?

Intermittent malfunction (Refer to


GROUP 00 - How to Cope with Intermittent
Malfunction .)

Replace the A/T-ECU.

STEP 9. Connector check: B-15


A/T control solenoid valve
assembly connector

Check for the contact


with terminals.

Q. Is the check result


normal?

Go to
Step 10.

Repair the
defective connector.
STEP 10. Measure the resistance
at A/T control solenoid valve
assembly connector B-15.

Disconnect the connector, and


measure the resistance between
terminal No.5 and No.9 at the
solenoid valve side.
OK: 2.7 - 3.4 Ω (A/T fluid
temperature 20°C)

Q. Is the check result


normal?

Go to Step 11.

Check the solenoid


valve harness.
STEP 11. Connector check: A-
19X A/T control relay connector,
B-10 intermediate connector

Check for the


contact with
terminals.

Q. Is the check
result normal?

Go
to Step 12.

Repair the defective


connector.
STEP 12. Check the harness
between A/T control solenoid
valve assembly connector B-15
terminal No.9 and A/T control
relay connector A-19X terminal
No.3.

Check the power supply line for short or


open circuit.

Q. Is the check result normal?

Go to Step 8.

Repair the wiring harness.