Sie sind auf Seite 1von 7

Name of Contractor: Contractor:

Project: Contact Person:


Scope: Contact Nos.:
Location: Delivery & Installation:
Terms:
Customer: Warranty:
Brand:

Description Quantity Unit Material Cost Labor Cost Total Cost

Mobilization/Demobilization 1 lot
Temporary Facilities (Power and Water Consumption) 1 lot
Others/RESTORATION

1. Supply, Delivery, Wiring, Installation, Programming, Testing, and Commissioning of IP CCTV and WiFi System
1. Floor Plan Layout provided by the client
2. Home run located at Admin

1. 220Vac tapping for the power supply of the equipment and devices shall be provided by Electrical Contractor.
2. Distance from network switch to cameras must not exceed 90 meters.
3. This IP CCTV System is capable of 30 days recording at 1MP resolution
4. CCTV Main Equipment is located at Admin Office
5. Bullet and Dome Camera are PoE enabled
6. Roughing ins, Chipping and Restoration not included.
7. CCTV Cameras will be directly connected directly to the NVR.
8. WiFi Access Points will be using patch panel/patch cords
Elevator contractor has already provided RG6 cable for CCTV in the elevator. Ethernet-over-Coax will be used to cater IP cameras

CCTV
FDAS Peripherals
HIKVISION Bullet - 1MP 1/4" Progressive CMOS, ICR, 1280x720:25fps(P)/30fps(N),
2.8mm/F2.0 lens, H.264, IP67, IR range: up to 30m, DC12V & PoE 2 unit/s
HIKVISION Dome - 1MP 1/2.8" Progressive CMOS, ICR, 25fps(P)/30fps(N), 2.8mm/F2.0
lens, H.264+&H.264, IP67,IK10, IR range: up to 30m, DC12V & PoE 33 unit/s
ACCESS POINT
UniFi WiFi Access Point, AC Long Range 32 unit/s
UniFi WiFi Access Point, AC Mesh 1 unit/s
UniFi WiFi Access Point, AC In-wall 2 unit/s
CCTV Main Equipment
160Mbps Bit Rate Input Max (up to 16-ch IP video), 2 SATA interfaces, 16 independent 2 unit/s
PoE network interfaces, 380 1U case, alarm I/O: 4/1, 300meters transmission per PoE
port
24" Full HD Monitor 3 unit/s

AIDE Series Line Interactive 2000VA/1200W 1 unit/s


CCTV Power Supply, 12V, 2A (for Elevator Cameras) 6 unit/s
PC / Server and Network Device Components
4ft / 28 RU Closed Data Cabinet 1 unit/s
LS 48-port patch panel Loaded 1 unit/s
LS Horizontal Cable Manager, 2 RU 1 unit/s

1/2" ø Flexible Metal Conduit 130 mts


1/2" ø Metal Connector 130 pcs

Square Box with Cover (for Cameras) 70 set/s

3/8" Tox and Screw 2 box/s


2" Black Screw Pointed 280 piece/s

LS UTP CAT6 (305m/roll) 10 roll/s


RJ-45 for Cat6 Connector 150 roll/s

Technical Engineer/PIC (coordination on site/process of work permit etc) 1


Safety Officer 1
Complete PPE

Installation 1 lot
Roughing-In Works 1 lot
Wiring Works 1 lot
Programming c/o intellismart
Testing & Commissioning 1 lot
Name of Contractor: Contractor:
Project: K3 HOTEL Contact Person:
Scope: FDAS Contact Nos.:
Location: KALAYAAN Delivery & Installation:
Terms:
Customer: DEI PROPERTIES Warranty:
Brand:

Category CTN Description Quantity Unit Material Cost Labor Cost Total Cost
Technical Services
Mobilization/Demobilization 1 lot
Temporary Facilities (Power and Water Consumption) 1 lot
Others/RESTORATION

GIVEN/SCOPE OF WORKS:
1. Wiring, Installation, Programming, Testing, and Commissioning of Fire Detection and Alarm System
2. Floor Plan Layout provided by the client
3. Home run located at Admin

ASSUMPTIONS/NOTATION:
1. 220Vac tapping for the power supply of the equipment and devices shall be provided by Electrical Contractor.
2. Roughing-ins will be provided by other Electrical Contractor.

Equipments
FDAS Fire Alarm Control Panel
Panel controller, English 1 set
FDAS Peripherals
Addressable Smoke detector, optical w/ base 163 pc/s
Addressable Heat detector w/ base 1 pc/s
Manual call point indoor, red 25 pcs
Conventional Horn/Strobe 25 pcs
Interface module conventional use, surf. for horn strobe 9 pcs
Input Interface Modules 10 pcs
Interface module relay high-volt surface 27 pcs
Interface module relay low-volt surface 2 pcs
Main Panel Assembly
Fire Telephone Panel (8-zone) 1 set/s
Field Devices
Fire Telephone Jack 38
Accessories
AVR 1500W Servo-type 1 unit/s

Pipes and Fittings (PVC):


1/2" ø Flexible Metal Conduit 290 mts
1/2" ø Metal Connector 290 pcs
Boxes and Cabinets:
Junction Box with Cover (for Corners, Connections and Device)
1" #6 Tox and Black Screw 164 pcs
Black Screw Pointed 1" 10 pcs
Wiring and Connector Components 660 pcs

Shielded Twisted Pair (18 AWG) - For Phone Jack 1 roll


TF WIRE #16 (150m/roll) B&R 32 rolls

Other Inclusions/scope Technical Engineer/PIC (coordination on site/process of work permit etc) 1


Safety Officer 1
Complete PPE

Installation 1 lot
Roughing-In Works 1 lot
Wiring Works 1 lot
Programming c/o intellismart
Testing & Commissioning 1 lot
Name of Contractor: Contractor:
Project: K3 HOTEL Contact Person:
Scope: ANALOG INTERCOM Contact Nos.:
Location: KALAYAAN Delivery & Installation:
Terms:
Customer: DEI PROPERTIES Warranty:
Brand:

Category CTN Description Quantity Unit Material Cost Labor Cost Total Cost
Technical Services
Mobilization/Demobilization 1 lot
Temporary Facilities (Power and Water Consumption) 1 lot
Others/RESTORATION

GIVEN/SCOPE OF WORKS:
1. Supply, Delivery ,Wiring, Installation, Programming, Testing, and Commissioning of Intercom System
2. Provided Floor Plan Layout from the client.

ASSUMPTIONS/NOTATION:
1. 220Vac tapping for the power supply of the equipment and devices shall be provided by Electrical Contractor.
2. All equipment were designed by PRDD. This is an analog Intercom system.
Equipments
Intercom Main Equipment
Due Fili wall-mounted interphone, white 107
Power Supply and Separator
Due Fili power supply unit 110-240V 2
Separator for Due Fili sytstems 10
Supply unit DueFili 110-240V 10
Switchboard and Power Supply
Due Fili add. power supply unit 230V 1
Porter switchboard 7in DueFiliPlus black 1

Boxes and Cabinets:


Metal Utility Box 94
6mm Tox and Screw 5 set/s
Wiring and Connector Components

UTP CAT 6 Cable 13 roll/s

Other Inclusions/scope Technical Engineer/PIC (coordination on site/process of work permit etc) 1


Safety Officer 1
Complete PPE

Installation 1 lot
Roughing-In Works 1 lot
Wiring Works 1 lot
Programming c/o intellismart
Testing & Commissioning 1 lot
INTELLISMART TECH. INC
12 Catanduanes St. West Avenue, Quezon City

Attention:Ms. Rose Ann S. Bolisay


Executive/Admin Assistant

Subject: Complete Supply of Labor Only for K3 Hotel


FDAS, CCTV, Intercom

Gentlemen:

As per aboved subject we are pleased to submit our cost proposal amounting to PESOS:
Three Hundred Fifty Seven Thousand Nine Hundred Sixty & 00/100 (Php 357,960.00) only with

NO. Description UNIT QTY


I. CCTV System
I.1 Installation lot 1
I.2 Roughing-In Works lot 1
I.3 Wiring Works lot 1
I.4 Testing & Commissioning lot 1

II. Fire Detection and Alarm System


II.1 Installation lot 1
II.2 Roughing-In Works lot 1
II.3 Wiring Works lot 1
II.4 Testing & Commissioning lot 1

III. Intercom System


III.1 Installation lot 1
III.2 Roughing-In Works lot 1
III.3 Wiring Works lot 1
III.4 Testing & Commissioning lot 1

IV. PRELIMINARIES lot 1


(Inc.Mobilization, demobilization, supervision and temfacil)
Total

Terms & Conditions: Works/ Items excluded:


a. ) Mobilization One 3-5 days upon receipt of 1.)
P.O. and downpayment.

50% Downpayment, 2.)


b. ) Terms Remaining Progress Billing
Price Subject to confirmation 3.)
c. ) Validity at time of order
d. ) Warranty N/A 4.)
5.)
Notes: 6.)

See attached RFQ for scope of works breakdown 7.)

We hope you find our cost proposal acceptable and looking forward for your valued order soon.

Yours Sincerely:
_____________________
Hilario Escat
27-Aug-19

mounting to PESOS:
(Php 357,960.00) only with details below:

UNIT COST
TOTAL
MATERIAL LABOR

INTELLISMART 6,552.00 6,552.00


INTELLISMART 22,932.00 22,932.00
INTELLISMART 36,036.00 36,036.00
INTELLISMART 15,000.00 15,000.00

INTELLISMART 10,920.00 10,920.00


INTELLISMART 38,220.00 38,220.00
INTELLISMART 60,060.00 60,060.00
INTELLISMART 15,000.00 15,000.00

INTELLISMART 5,824.00 5,824.00


INTELLISMART 20,384.00 20,384.00
INTELLISMART 32,032.00 32,032.00
INTELLISMART 15,000.00 15,000.00
-
80,000.00 80,000.00
357,960.00

Works/ Items excluded:


Charges for the use of building facilities (if any)
such as electric, water, lifts, etc.
All necessary civil works such as provision of wall
and / or ceiling openings and its restoration to
complete the above scope of works.
Complete Supply of Materials, consumables to
complete the system

Construction plan and building permits.


As-built plans.
Permits & licenses
Programming and activation of system by Intellismart

or your valued order soon.

Das könnte Ihnen auch gefallen