i02404376
2. Use a suitable digital multimeter to check continuity (resistance). Turn the audible signal on the digital multimeter
ON.
3. Place one probe on the connection for the glow plug and the other probe to a suitable ground. The digital
multimeter should make an audible sound. Replace the glow plug if there is no continuity.
4. Connect a suitable digital multimeter to the terminal on the glow plug and to a suitable ground.
5. Turn the switch to the ON position in order to activate the glow plugs.
Table 1
12 Volt System
https://s1.remotelab.space:500/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage… 1/2
8/16/2019 C7.1 DE200E0/DE220E0 Generator Set GTY00001-UP(SEBP7395 - 11) - Documentation
16.6 Initial
12 5.7
9 11.1
7 20
6 60
Table 2
24 Volt System
9 Initial
7 3.3
6 5.3
3 60
7. If there is no reading on the ammeter check the electrical connections. If the readings on the ammeter are low
replace the faulty glow plug. If there is still no reading replace the faulty glow plug.