Sie sind auf Seite 1von 17

Site Survey Report (SSR) –

Tower Works Upgrade Doc. Ref. No.


Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 1 of 17

VENDOR HUAWEI
SITE ID R38
SITE NAME EL SALVADOR
SITE TYPE GREENFIELD
REGION NORTHERN MINDANAO

SITE DETAILS
Longitude: 8° 33' 38" Latitude: 124° 31' 33" Ground Elevation: 10m
GPS coordinates, reception from min. 3 satellites, WGS 84, magnetic north, decimal / 6 digits after decimal point;

Site Address: Zone II, Poblacion , El Salvador City, Misamis Oriental

SUMMARY OF KEY TOWER CONVERSION REQUIREMENTS


Structure Replacement Additional Tow er
Type of Works?

Is a Lot Extension Required? Yes No

Are there any Permitting problems likely to be experienced? Yes No

Does the existing Van/Cabin need to be relocated? Yes No

Does the existing Service Entrance need to be relocated? Yes No

Does the existing Horizontal Cable Ladder need to be relocated? Yes No

Do any existing Generator/s need to be relocated? Yes No


1 genset near main pole pedestal of tower

Do any existing Generator Pads need to be demolished? Yes No

Do any existing Guyed Wires/Foundations need to be relocated? Yes No

Does the existing Gate need to be relocated? Yes No

Does any of the Existing Boundary Wall Need to be demolished? Yes No

Does the new Tower need to be painted? Yes No


approximately 300 m away from seashore

VENDOR/CONTRACTOR SITE SURVEY PARTICIPANTS


SIGNATURE: SIGNATURE:

NAME: NAME:

DATE: DATE

SMART APPROVAL
SAQ INFRA TPE ACCESS

SIGNATURE:
NAME:

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 2 of 17

DATE:
EXISTING “ACCESS” ANTENNAE INFORMATION
Technology No.1 900 1800 2100 850 WiMAX Canopy Combi Other -

Sector Number 1 (A) 2 (B) 3 (C) 4 (D)


No. of Antenna 1 2 3
Azimuth 300˚ 180˚ 240˚
Center Height 44.2 m 44.2 m 44.2 m
Feeder length 47.2 m 47.2 m 47.2 m

Technology No.2 900 1800 2100 850 WiMAX Canopy Combi Other -

Sector Number 1 (A) 2 (B) 3 (C) 4 (D)


No. of Antenna 1 2 3
Azimuth 350˚ 180˚ 240˚
Center Height 44.2 m 44.2 m 44.2 m
Feeder length 47.2 m 47.2 m 47.2 m

Technology No.3 900 1800 2100 850 WiMAX Canopy Combi Other -

Sector Number 1 (A) 2 (B) 3 (C) 4 (D)


No. of Antenna 1 (twin) 2 (twin) 3 (twin)
Azimuth 345˚ / 350˚ 150˚/190˚ 340˚/360˚
Center Height 45 m 45 m 45 m
Feeder length 48m 48m 48m
Technology No.4 900 1800 2100 850 WiMAX Canopy Combi Other - LTE

Sector Number 1 (A) 2 (B) 3 (C) 4 (D)


No. of Antenna 1 2 3
Azimuth 245˚ 140˚ 220˚
Center Height 44.2 m 44.2 m 44.2 m
Feeder length 47.2 m 47.2 m 47.2 m

PROPOSED ADDITIONAL “ACCESS” ANTENNAE INFORMATION


Technology No.5 900 1800 2100 850 WiMAX Canopy Combi Other -

Sector Number 1 (A) 2 (B) 3 (C) 4 (D)


No. of Antenna 1 2 3
Azimuth 335˚ 120˚ 145˚
Center Height 44.2 m 44.2 m 44.2 m
Feeder length 47.2 m 47.2 m 47.2 m

Technology No.1 900 1800 2100 850 WiMAX Canopy Combi Other -

Sector Number 1 (A) 2 (B) 3 (C) 4 (D)


No. of Antenna
Azimuth
Center Height
Feeder length

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 3 of 17

EXISTING MICROWAVE INFORMATION


Link Number 1 2 3 4
Azimuth 70˚
Center Height 29.5 m
Dish Ø .60mØ
Link Number 5 7 8
Azimuth
Center Height
Dish Ø
Link Number 9 10 11 12
Azimuth
Center Height
Dish Ø
Link Number 13 14 15 16
Azimuth
To Site (ID)
Center Height
Dish Ø
Link Number 17 18 19 20
Azimuth
To Site (ID)
Center Height
Dish Ø

PROPOSED ADDITIONAL “MICROWAVE” ANTENNAE INFORMATION


Link Number 1 2 3 4
Azimuth
To Site (ID)
Center Height
Dish Ø
Project
Link Number 5 6 7 8
Azimuth
To Site (ID)
Center Height
Dish Ø
Project
Comments:

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 4 of 17

PERMITTING & SITE DEVELOPMENT INFORMATION


Are any Permitting issues likely to be No Yes, please specify below .
experienced in undertaking the works?

Existing Lease Area (m): 213.72 sq.m (13.7m x 15.6m)


Name of Nearest Airport? Laguindingan International Airport
Distance from Airport to the site (km)? Approximately 15 km away
Does the Structure need to be painted? Yes (If a structure is w ithin 3km of an airport it needs to be painted, mandated
No by City/Municipality and if located on high altitude (Mountainous);)

Does an Aviation Height Restriction


No Yes
Apply?
If Yes, What is the Height Restriction
NONE
from ground level?
What is the distance of the site from the
>1.5 km <1.5 km (Exposure Category "C" NSCP is NOT appropriate)
coastline?
Wind Speed Zone (as per NSCP 2015)? ZONE II

Van / Cabin Size:

Outdoor Cabinet
Existing Equipment Housing:
Existing Equipment Room

Other Please specify?

What is the Condition of Existing Equipment No Rust Partially Rusted (<10%)


Housing? Heavily Rusted

Existing Perimeter Fence?


Other Please specify?

What is the Condition of Existing Perimeter


Fence?
Other Please specify?

Sub-Meter from Ow ner Distribution Panel Pow er Supplier (Meralco or equiv)


Power Supply?
Permanent Generator Other -

What is the highest flood


How long ago was How long has the
level on the site according NONE
that flood level? owner lived there?
to the owner?
What is the highest flood
How long ago was How long has the
level on the site according NONE
that flood level? neighbor lived there?
to the neighbor?

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 5 of 17

Existing Antenna Support Structure Details (Lot Site)

Guyed Tow er Height (m): 45 No.: 1

Guyed Pole Height (m): No.:

4 Legged SST Height (m): No.:


Structure Type:

3 Legged SST Height (m): No.:

Other Please specify:

Is the existing structure straight? Yes No

Is the structure galvanized? Yes No

What is the condition of the structure? No Rust Partially Rusted (<10%) Heavily Rusted

None Ladder & Backcage Working Platform/s


What climbing safety system is installed on the site?
Fall Arrest System

Is the existing structure painted? Yes No

Is there an existing Aviation Light on the structure? Yes No

Is there an existing Aviation Light working on the structure? Yes No

New Antenna Support Structure Details (Lot Site)

Without Cutdow n Height (m): No.:

No.:

No.:
New Antenna Support
Structure Type:

Other Please specify:

No.:

Minimum Information on Sketches


Plan - North Point Lease Boundary Boundary Wall & Gate New & Existing Antenna's

New & Existing Antenna Support Structure Existing Equipment Housing Slope

New & Existing Cable Ladder Existing Generator Pads Earthing System Connection Point/s

Elevation - Site Levels New & Existing Antenna Support Structure Existing Equipment Housing

New & Existing Cable Ladder New & Existing Antenna's

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 6 of 17

Minimum Photos Required


Front View Side View Proposed Antenna Support Structure Location

Existing item/s to be removed or relocated. Existing Antenna Support Structure Existing Cable Ladder

Existing Porthole Item/s to be demolished

Existing Condition Report – Photograph and make comments regarding the following:

Outside the Site: Cracked, aged or broken items and vegetation w ithin 30m of any site w orks (roads, trees etc)

Inside the Site: Cracked, aged or broken items.

Existing Items to be relocated

Existing Antenna Support Structure Details (Rooftop)


Building Height N/A No. of Floors: N/A Age of Building: Years

Overall Structural Condition / Integrity of Building? New Good Average Poor (Aged, lots of cracks)

Do any drawings exist for the building? No Yes (get a copy of the draw ings if possible)

Guyed Mast Height: No.:

Bipod Height: No.:

Pole Height: No.:

Structure Type Wall Mount Height: No.:

Guyed Pole Height: No.:

Tow er Height: No.:

Other Please specify: N/A

What are the dimensions of the column under the


Bipod/Tower? N/A
Does reinforcement stick out from the columns? No Yes, add the number and size of the bars: N/A

What are the Beam Sizes? N/A


What is the slab thickness? N/A
Reinforced Concrete Post-Tensioned Concrete Other -
What is the type of roof slab?
N/A

Is there a topping on the rooftop slab? No Yes

Is there a waterproof membrane on the rooftop slab? No Yes

What is the condition of the structure? No Rust Partially Rusted (<10%) Heavily Rusted

Is the existing structure painted? Yes No

Is there an existing Aviation Light on the structure? Yes No

Is there an existing Aviation Light working on the structure? Yes No

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 7 of 17

New Antenna Support Structure Details (Rooftop)

Floor Mount Height: No.:

Wall Mount Height: No.:


New Antenna Support Structure
Type: No.:
Tow er Height:

Other Please specify: N/A

Rooftop/Rooftop Co-location – Minimum Information on Sketches

Plan - North Point Building Outline Road or Street Names Rooftop Entry Point Antenna Support Structure/s

Existing item/s to be relocated or removed Location and size of columns, beams & slabs Equipment Housing

Earthing & Lightning Cables Pow er Cable Pow er Meter Earthing Pits Cable Ladder

New & Existing Antenna's (including orientations)

Elevation - Building Outline Antenna Support Structure/s Equipment Housing Earthing & Lightning Cables

Pow er Cable Pow er Meter New & Existing Antenna's (including orientations) Cable Ladder

Rooftop/Rooftop Co-location - Minimum Photos Required

Front of Building Side of Building Proposed Antenna Support Structure Location/s Proposed Equipment Housing Location

Existing item/s to be removed or relocated. Feeder Cable Routes Pow er Meter Location Pow er Cable Route

Dow nconductor Route Earth Pit Location

Rooftop/Rooftop Co-location Existing Condition Report – Photograph and make comments regarding the following:

For all the areas affected by construction of the site.


Cracks in slabs, beams, columns and w alls. Exposed Reinforcement in slabs, beams, columns and w alls.

Water Penetration into building. Rusted Steelw ork Existing Items to be relocated

Excessive Deflections/Movement of slabs, beams, w alls etc. Any items near the w orks w hich is old/degraded.

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 8 of 17

VICINITY MAP

SITE

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 9 of 17

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 10 of 17

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 11 of 17

ACCESS TO SITE

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 12 of 17

ACPDB :

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 13 of 17

PROPOSED SITE LOCATION

PROPOSED TOWER LOCATION

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 14 of 17

SITE DEVELOPMENT PLAN

NOTE: *Existing Lease Area = 213.72 sq.m (15.5m x 13.70m)


*Available Space for New Tower Location = Approx. 6.5Mx6.5M(42.25 SQ.M.)

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 15 of 17

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 16 of 17

SMART COMMUNICATIONS INC ©


Site Survey Report (SSR) –
Tower Works Upgrade Doc. Ref. No.
Date: 2019 april 25
Owner SFPE Revision 1 Page: Page 17 of 17

Sketches

SMART COMMUNICATIONS INC ©

Das könnte Ihnen auch gefallen