Sie sind auf Seite 1von 71

VSP

MICROCODE VERSION 70-04-01-00/00-M114


RELEASED 06/27/2012

New supported features and functions for Version 70-04-01-00/00-M114


1. Mainframe & Open System

1-1 Support for Generic Profile


Description Volumes of external storages, which are not listed in FRS-I, can be mapped.
Changed Part DKCMAIN, SVP

1-2 Support for key management server


Description The following server is supported to backup encryption keys used to encrypt the data stored
in storage system.

A key management server that supports Key Management Interoperability Protocol (KMIP),
which is in particular;
SafeNet KeySecure K460 (Software version: 6.1.0)
Changed Part Storage Navigator

1-3 CCI enhancement


Description The following CCI commands are supported in V04.
1- raidcom modify host_grp
A host mode option for an initiator port (the command can work for round trip).
2- raidcom modify clpr
A CLPR migration command for each resource.
3- raidcom modify external_grp
Added setting of extension round robin mode to the command.
4- Server Priority Manager (SPR) commands
-raidcom add spm_wwn
A WWN SPM name (nickname) prioritized or non-prioritized is added.
-raidcom add spm_group
A WWN SPM group is registered.
-raidcom delete spm_wwn, raidcom delete spm_group
A WWN SPM is deleted.
-raidcom modify spm_wwn, raidcom modify spm_group
A WWN SPM information is set.
-raidcom get spm_wwn, raidcom get spm_group
A WWN SPM information is obtained.
-raidcom monitor spm_wwn, raidcom monitor spm_group
WWN monitoring information is obtained.

For details, see CCI Command Reference Guide or manuals for each PP.
Changed Part DKCMAIN

1-4 Support for RAID6 (14D+2p)


Description As a new RAID level, RAID6 (14D+2P) is supported.
Changed Part DKCMAIN, SVP

HDS Confidential 1 of 71
1-5 Improvements to ease restrictions on maintenance
Description Improvements to ease restrictions on maintenance are implemented. In particular, the
following operations are allowed.
1- LDEV format for RAID groups other than those in copy processing during Dynamic
Sparing, Correction Copy, and Copy Back
2- Replacement of PDEVs other than ones in LDEV format processing during LDEV format
3- Online micro-program exchanges of other than DKU and SCHIP during Dynamic
Sparing, Correction Copy, and Copy Back.
4- Installation/removal of CHA, DKA, cache, MPB, and RAID group while data has been
backed up in a spare drive. However, a RAID group and spare drive which are in backup
process cannot be removed (current specification).
5- Installation/removal of external volumes and virtual volumes from Storage Navigator
while a PDEV is blocked.
Changed Part DKCMAIN, SVP

1-6 Modification for DT tier configuration condition


Description The following are supported.
1- Coexistence of 4 or more drive types in a DP/DPz or DT/DTz pool.
- 4 or more drive types can coexist in a DP/DPz or DT/DTz pool.
- If 4 or more drive types coexist in a DP/DPz or DT/DTz pool, the drive type with the
highest priority goes in Tier1, the drive type with the second highest priority goes in Tier2,
and other drives are mixed in Tier3.
Priority order (from high to low) = SSD, SAS 15K, SAS 10K, SAS 7.2K, SATA, external
high, external middle, and external low.
2- Tiering external drive
- External volumes can be classified in external high, external middle and external low by
the user.
- Those classified external drives can exist as an individual tier.
3- Coexistence of RAID levels in a tier
- Different RAID levels can coexist in a tier.
- If drives of the same drive type and different RAID levels are used in the same DP/DPz or
DT/DTz pool, the drives belong to the same tier.
Changed Part DKCMAIN

1-7 Support for rebalance of usage rate among parity groups with pool volumes
Description New System Option Mode 917 is available to average the usage rate among parity groups
with pool volumes defined to reduce drive load of the parity groups.
- Mode 917 = ON (default):
Usage rate is averaged among parity groups where pool volumes are defined.
- Mode 917 = OFF:
Usage rate is averaged among pool volumes without considering parity groups.
Public Mode – No Permission Required to Use
Changed Part DKCMAIN

1-8 Support for Load Balance Mode


Description As an option for external volumes, Load Balance Mode is supported.
The Load Balance Mode determines a method to balance the load when multiple paths are
used, has 3 modes; Normal Round-robin (normal mode), Extended Round-robin (extended
mode), and Disabled (using only one path), and can be set and referred from Storage
Navigator and CCI.
Changed Part DKCMAIN, SVP

HDS Confidential 2 of 71
1-9 Support for delta resync when TC/ UR and TCz /URz in same CTG
Description The Delta resync function is supported when TC/UR and TCz/URz pairs are in the same
CTG.
Changed Part DKCMAIN

1-10 UR restore processing improvement


Description The allocation for a UR/URz restore processing is changed from per pair volume to per
track (slot), so that the restore processing performance can be maintained without reducing
the restore multiplicity on the secondary volume side even though the number of pairs in the
journal is small or the data update processing is focusing on a specific pair volume.

New System Option Mode 909 is available to disable the UR/URz restore processing
improvement.

Restricted Mode – RSD Permission Required to Use


Changed Part DKCMAIN

1-11 Support for Expander dump information collection


Description Dump information can be collected from an SSW that is blinking at a replacement of the
SSW whose SAS port is blocked.
In this case, SIM=CF12XX (XX=SAS PORT#) is output.
Changed Part DKCMAIN

1-12 Support for new external storages


Description The following storages are supported as external storages without profile tool.
Hitachi: HUS
DELL: Compellent
XIOTECH: HyperISE
Changed Part DKCMAIN

1-13 Improvement for Storage Navigator messages


Description Storage Navigator messages are modified to be more understandable according to review
results with partners.
Changed Part SVP, Storage Navigator

1-14 Support for SOM786 to report pair status of TC/TCz RCU side
Description System Option Mode 786 is available to report to MCU the pair status on TC/TCz RCU side
even when there is no RIO and the pair status on RCU changes after the remote copy path
between MCU and RCU is disconnected and then recovered.

Restricted Mode – TS Permission Required to Use


Changed Part DKCMAIN

1-15 SATA TAGs reduction by setting SOM798


Description System Option Mode 798 is available to prevent Check Condition returned when the queue
of commands issued to SATA is full by reducing the number of the commands.

Restricted Mode – TS Permission Required to Use


Changed Part DKCMAIN

HDS Confidential 3 of 71
1-16 SVP security enhancement
Description The following security enhancements are done for SVP.
- Unnecessary TCP ports of SVP are blocked.
- SSL certificates of RMI can be replaced. (For procedures to replace the certificates, see the
Storage Navigator User Guide.)
- Components of SSL Ciphersuite that contain vulnerability are excluded.
Changed Part SVP

1-17 Support for SOM600 and 601 to change UR initial copy pace
Description New System Option Modes 600 and 601 are available to change the UR initial copy pace
(MIDDLE mode) from125MB/s to 250MB/s or 500MB/s as follows.
When SOM600 is set to ON: 250MB/s
When SOM601 is set to ON: 500MB/s
- Restricted Mode – RSD Permission Required to Use
Changed Part DKCMAIN

1-18 I/O performance improvement


Description Micro-program processing is updated so that I/O processing performance of random
accesses is improved. (This improvement is different from that of Flash Acceleration)
Changed Part DKCMAIN

2. Mainframe System

2-1 Support for zHPF Multi Track function


Description The Multi Track function of High Performance FICON (zHPF) in Mainframe (IBM host)
environment is supported. The zHPF Multi Track function is an expansion of zHPF and
enables reading/writing multiple tracks by a single command.
With this support, the following become available:
-Overhead of command processing can be reduced as much as possible.
-Path band can be used efficiently.
-High-speed fully-duplicated transfer is available.
Changed Part DKCMAIN, HTP

2-2 Support for z/OS FICON Discovery and Auto Configuration for System z
Description Z/OS FICON Discovery and Auto Configuration for System z function (zDAC) in
Mainframe (IBM host) environment are supported. The zDAC is a function to do the
following operations automatically.
-To detect new or updated devices
-To create configuration definition of I/O devices
This function enables to automate and simplify operations that rely on users, such as
reduction of the time required to set up new I/O devices, mitigation of requirements for
expertise skill, and keeping consistency of the entire system and storage system definitions,
so that management cost of users can be reduced drastically. This function is a z/OS
function. For the information of system environment, operating procedures, and notes, see
documents provided by IBM such as Readbook.
Changed Part DKCMAIN, HTP

2-3 Support for SOM910 for FC Establish command response improvement


Description New System Option Mode 910 is available to improve FC Establish command response
Restricted Mode – RSD Permission Required to Use
Changed Part DKCMAIN

HDS Confidential 4 of 71
2-4 Support for 3DC multi target and cascade of URz
Description In Mainframe environment, 3 data center (3DC) multi target and cascade configurations
using Universal Replicator for Mainframe only are supported.
-Multi target: A function to back up the data in a P-VOL (primary site) to 2 S-VOLs
(secondary site).
-Cascade: A function to back up the data in a P-VOL to an S-VOL (intermediate site), and
then back up the data in the S-VOL to another S-VOL (secondary site).
Changed Part DKCMAIN

2-5 Support for ELB (Extended Long Busy)


Description - TrueCopy for Mainframe
The time of TCz SCP (Status Change Pending) setting, which is currently 600 seconds at the
maximum, is increased to up to 6 days. With the support, when SCP is set to a TCz pair by a
Freeze command and so on, host I/Os become in Extended Long Busy status and are
pending for up to 6 days until the Freeze is canceled by a Run command. In the case that the
host system cannot be stopped or switched to the RCU within 600 seconds after a Freeze
setting, this function can prevent data update on the MCU side which may occur if SCP is
canceled.
- FlashCopy
The time of FC SCP (Status Change Pending) setting, which is currently 600 seconds at the
maximum, is increased to up to 6 days. With the support, when SCP is set to an FC pair by
an Establish command with Freeze option specified, host I/Os become in Extended Long
Busy status and are pending for up to 6 days until the SCP setting is canceled.
Changed Part DKCMAIN, SVP

2-6 Support for Query Storage Controller Status command


Description For compatibility with IBM hosts, the Query Storage Controller Status command is
supported. New System Option Mode 915 is available to disable this support.
-Restricted Mode – RSD Permission Required to Use
Changed Part DKCMAIN

2-7 Support for SOM598 to report SIM for JNL overflow


Description When the usage rate of meta data or journal data space reaches the threshold value (80%),
SIM (DCE0, DCE1, DCE2, or DCE3) for a JNL overflow warning is reported to the host.
New System Option Mode 598 is available to enable the SIM report.
Public Mode – No Permission Required to Use
Changed Part SVP

3. OPEN System
3-1 Support for per-page allocation policy setting
Description Per-page policy setting is supported.
Tier allocation policy (Level1 only) can be set per page.
Per-page setting is prioritized over per-virtual VOL setting.
Frequency distribution information per lane of DT can be obtained from RAID Manager
Lib. The setting and reference are only available on Hi-Command.
Changed Part DKCMAIN

3-2 Support for LDEV# virtualization of ID takeover


Description For ID takeover, the following functions are added.
Specifying an arbitrary number for an LDEV and an arbitrary number for an SSID.
Changed Part DKCMAIN, CCI

HDS Confidential 5 of 71
3-3 Support for HMO68
Description New Host Mode Option 68 is available to enable Linux to issue Write Same (16) command
so that pages that the host has used are released.
-Mode 68 = ON:
The Version field of Standard Inquiry is set to 05h.
LBPRZ and LBPME bit of Read Capacity (16) are set.
Block Limits VPD Page and Logical Block Provisioning VPD Page are supported.
-Mode 68 = OFF (default):
The Version field of Standard Inquiry is set to 02h.
LBPRZ and LBPME bit of Read Capacity (16) are not supported.
Block Limits VPD Page and Logical Block Provisioning VPD Page are not supported.
-Public Mode – No Permission Required to Use
Changed Part DKCMAIN

3-4 Support for Flash Acceleration for Simplex VOL and DP-VOL
Description The performance is improved at cache miss for Simplex VOL and DP-VOL in OPEN
environment by reducing micro-program processing. The PP license of Flash Acceleration
must be installed to enable this function.
Changed Part DKCMAIN

3-5 CCI (RAID Manager) 01-28-03/05


Description Supporting function contents from Ver. 01-27-03/06
-Support for PPC (SPM) used CLI
-Addition of an option for setting CLPR
-Addition of an option for setting Load Balance Mode for ELun
-Addition of an option for specifying a virtual SSID
-Addition of an option for displaying each Tier level
-Support of Cluster Device Special File for Serviceguard/HP-UX
-Addition of RAID Manager for Linux/x64

Revision contents from Ver. 01-27-03/06


- Corrected a syntax of raidcom command from "enalbe_relocation" to "enable_relocation".
Changed Part CCI (RAID Manager)

3-6 RAID Manager/LIB Ver. 01-16-03/04


Description Supporting function contents from Ver. 01-15-03/07
This version has added the following functions.
-Support for DF850
-Addition of the pool status to byte [14-15] of the getrminfo (POOL_CONF).
-Addition of the Capability (Role) checking to several function.
-Added EL_EPPERM as return value.
-Support for HM700
-Addition of Tier Type (High/ Low) for the external Volume to getrminfo
(POOL_CONF,POOL_STAT,LDEV_IO).
-Addition of a byte for specifying Tier level for get rminfo(POOL_STAT).
-Support of PPC (SPM) naming of 64 bytes

Revision contents from Ver. 01-15-03/07


-Changed to an fd that attachcmddev() does not depend on the channel of OVMS.
-Corrected a problem that getrminfo(LUN_WWN) cannot be done subsequent page.
Changed Part RAID Manager/LIB

HDS Confidential 6 of 71
The change of contents for Version 70-04-01-00/00-M114
1 Failure suspension at Flush suspend for all UR pairs in
JNLG
Phenomena When a suspend operation was performed for all UR/URz pairs (8192
pairs) in a JNLG with LU specified, SSB=EDBF and SIM=DC0XXX
were output and the operation turned to a failure suspension.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator or Universal Replicator for Mainframe
(2) System Option Mode 449 is set to OFF.
(3) There are 2000 or more pairs in a JNLG.
(4) Flush suspend is performed for all the above pairs with LU
specified.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator or Universal Replicator for Mainframe
Changed Part DKCMAIN

2 WCHK1 due to frequent CHK3 in MP


Phenomena Several minutes after DKA maintenance failed (replacement,
installation, or DKAF exchange), WCHK1 occurred due to frequent
CHK3 in one of MPs.
SSB=32FE, 1688, 3250, 397E and 3306
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) DKA maintenance (replacement, installation, or DKAF exchange)
is performed.
(2) CHK3 occurs during FW loading.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

HDS Confidential 7 of 71
3 Display of invalid dashed line in graph
Phenomena When "Maximum value display" or "Minimum value display" was
selected for [Display Option] on SVP and a graph for "Bad Received
Character Count. (Fibre)" was displayed, an invalid dashed line was
displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) "Port" is selected for Object in [Monitor Data Choice].
(2) "Loss Of Signal Count.(Fibre)", "Bad Received Character
Count.(Fibre)", "Loss Of Synchronization Count.(Fibre)", "Link
Failure Count.(Fibre)", "Received EOFs Count.(Fibre)", "Discarded
Frame Count.(Fibre)", "Bad CRC Count.(Fibre)", "Protocol Error
Count.(Fibre)", "Invalid Frame Count.", or "HTP/FNP Ex
Multiple.[Ex/sec.](FICON)" is selected for Item of [Monitor Data
Choice]. (Those are collectively called unsupported item.)
(3) "1 [min]" or "1 [hour]" is selected for [Sampling Rate(Display
Period)]
(4) "Maximum value display" or "Minimum value display" is checked
for [Display Option].
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

4 SSBs output at DKA installation


Phenomena During DKA installation, SSB=1BB0, 1BB1, 1C20, 1C21, 1C42,
1C43, and 8062 were output but the installation itself ended normally.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following operation (A) or (B) is
performed in that order.
Operation (A)
(1) DKA is removed.
(2) At the location where the above DKA removal is performed, a
CHA PCB other than DKA is installed.
(3) The above installed CHA PCB is removed.
(4) At the location where the above CHA PCB removal is performed, a
DKA is installed.

Operation (B)
(1) A CMF PCB is removed.
(2) At the location where the above CMF PCB removal is performed, a
DKA is installed.
Causes and Updates The micro-program has been modified not to output SSBs at DKA
installation.
Affected Products/Version DKCMAIN: All
SVP: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
SVP: 70-04-01/00
Category Open or Mainframe
Changed Part DKCMAIN, SVP

HDS Confidential 8 of 71
5 Failure of multiple SSBs output
Phenomena Even though multiple SSBs were supposed to be output, only one SSB
was output. (The problem occurred with SSBs created by SVP.)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when multiple SSBs are created by SVP in a
second.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

6 Incorrect use of "trace" for "dump" in [CGI] FD dump tool


Phenomena In [CGI] FD dump tool, "trace" was incorrectly used to indicate
"dump".
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when [CGI] FD dump tool window is displayed.
Causes and Updates The micro-program has been modified to fix the problem.
"Trace" is changed to "dump" in [CGI] FD dump tool.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

7 No output of failure information


Phenomena When a CHG PCB link failure occurred, the failure information was
not output on SVP monitor.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when FCoE link failure information is displayed
on SVP monitor.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
SVP: 70-02-03/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
SVP: 70-04-01/00
Category Open
Changed Part DKCMAIN, SVP

HDS Confidential 9 of 71
8 Unintentional change of Tier Management mode
Phenomena For DT where Tier Management mode was Auto, when tier capacity
ratio for new allocation was changed from CCI (raidcom modify pool
-pool <pool ID#> -tier <Tier number> <ratio>), the Tier Management
mode changed to Manual.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) DT where Tier Management mode is Auto.
(2) One of the following operations is performed from CCI.
(a) Change of tier capacity ratio for new allocation (raidcom modify
pool -pool <pool ID#> -tier <Tier number> <ratio>)
(b) Change of buffer rate of tier for relocation (raidcom modify pool -
pool <pool ID#> -tier <Tier number> -tier_buffer_rate <%>)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN

9 Incorrect sort order of LDEVs on some windows


Phenomena When one of the following windows of Storage Navigator was
displayed, LDEVs were not sorted in ascending order of LDEV ID at
default display.
- Expand V-VOLs
- Reclaim Zero Pages
- Stop Reclaiming Zero Pages
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when one of the following windows is opened
from a window where LDEVs are not sorted in ascending order of
LDEV ID.
- Expand V-VOLs
- Reclaim Zero Pages
- Stop Reclaiming Zero Pages
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 10 of 71
10 Invalid display of capacity unit
Phenomena Phenomenon 1:
Even though resources in a table list on the following windows were
for Open only, "cylinder" that was a display unit for Mainframe was
available in Options for display unit.

LUNs, Parity Groups, LDEVs, Resource Group Properties, External


LDEV Properties, Add LUN Paths, Delete LUN Paths, Add Resources,
Change Setting(External Vol), Select Parity Groups, Select LDEVs,
Remove Resources, Edit Encryption

Phenomenon 2:
For a table list on the following windows, "Cylinder" and "Page"
which were display units for Mainframe and pool VOLs respectively
were displayed in a unit of GB.

Edit Pools, Restore Pools, Shrink Pool, Stop Shrinking Pool, Monitor
Pools, Stop Monitoring Pools, Start Tier Relocation, Stop Tier
Relocation, Create Pools, Delete Pools, Pool Property

Phenomenon 3:
For a table list on the following window, "Cylinder" which was a
display unit for Mainframe was displayed in a unit of GB.

Expand Pool
Severity (High, Medium, Low) Low
Conditions of Occurrence Phenomenon 1:
The problem occurs when at least one Mainframe parity group or
LDEV exists in the configuration.

Phenomenon 2:
The problem occurs when the target window is displayed while pools
are displayed in a unit of cylinder or page on the previous window.

Phenomenon 3:
The problem occurs when the target window is opened while pools are
displayed in a unit of cylinder on the previous window.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part Storage Navigator

HDS Confidential 11 of 71
11 Incorrect sort order of resources
Phenomena On the following windows, setting target resources were not sorted in
ascending order.
Create Pools, Add External Volumes, Add to Host Groups, Add Hosts,
Delete LUN Paths, Delete Pools, Expand Pool, Edit Pools, Edit
External WWNs, Edit Command Devices, Edit CU Monitor Mode,
Edit WWN Monitor Mode, Add New Monitoring WWNs, Delete
External Volumes, Disconnect External Paths, Reconnect External
Paths, Add to Ports, Add Resources, Disconnect External Volumes,
Delete Host Groups, Delete Reports, Restore Pools, Shrink Pool
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when resources are not added in ascending order
during a user operation on any of windows above.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part Storage Navigator

12 Last letter of window name is missing on some windows


Phenomena When Edit Local Replica Options window was displayed in Solaris
Firefox environment, the last letter of window name hatched in crumb
trail was missing.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following windows are displayed from
Storage Navigator in Solaris Firefox or Unix environment.
- Edit Local Replica Options
- Edit Processor Blades
- Create LDEVs
- Select LDEVs
- Delete LUN Paths
- Edit Host
- Create Pools
- Add New Monitored WWNs
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part Storage Navigator

13 Spelling error in SVP message 2841, 4049, and 4050


Phenomena There was a spelling error in SVP messages 2841, 4049, and 4050.
In specific, the error was "power supplyes".
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when any operations which result in SVP
messages 2841, 4049, and 4050 output are performed.
Causes and Updates The micro-program has been modified to fix the problem.
"power supplys" is corrected to "power supplies".
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 12 of 71
14 Inconsistent version number between basic information and
manual
Phenomena For the downloaded audit log information files, the version number in
basic information was different from that described in manual.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when SVP micro-program of version 70-03-01/00
or higher is installed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-03-01/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

15 ABEND of micro-program exchange at status check


Phenomena While an SSW failure occurred (the SSW lamp blinked on
Maintenance window), if online micro-program exchange including
Expander or SSW was performed, the operation ended abnormally
(SVP message SMT2433E) at the status check conducted just before
starting the micro-program exchange.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) An SSW failure occurs (the SSW lamp blinks on Maintenance
window).
(2) One of the following operations is performed.
(a) Online micro-program exchange including Expander
(b) Online micro-program exchange including SSW
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

16 Too shot display time of tooltip of Storage Navigator


Phenomena Display time of tooltips of Storage Navigator was too short so that
messages could not be fully read if they were long.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a message of tooltip on Storage Navigator is
long.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part Storage Navigator

HDS Confidential 13 of 71
17 ABEND of micro-program exchange when MP overload is
detected
Phenomena When micro-program exchange was started from FC WIZARD, if MP
overload was detected and the micro-program exchange was stopped, a
message (SVP Internal Error) was displayed on FC WIZARD window
and the operation ended abnormally.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Micro-program exchange is performed from FC WIZARD.
(2) MP load is 50% or higher.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

18 Monitor information wrongly remained after switching OFF


tier relocation setting
Phenomena When tier relocation setting of a pool was switched from ON to OFF,
the monitor information collected for the pool was wrongly kept.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Tier relocation for a pool is set to ON.
(2) Monitor information has been collected while start and end of
performance monitoring are already performed.
(3) Tier relocation for the pool is set to OFF.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN for Open: All
DKCMAIN for Mainframe: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN

19 SSB=35F3 and SIM=3DC0XX output at MPB replacement


or installation
Phenomena When MPB replacement or installation was performed after online
micro-program exchange of DKCMAIN was stopped, SSB=35F3 and
SIM=3DC0XX might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Online micro-program exchange of DKCMAIN is stopped.
(2) After the exchange is stopped, MPB replacement or installation is
performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

HDS Confidential 14 of 71
20 No response of Storage Navigator window
Phenomena Storage Navigator window became white and no response was
returned.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Flash Player does not respond at all when
Storage Navigator is being activated.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

21 Inadequate SSBs output when command is rejected


Phenomena When a resource migration command was executed from CCI with an
unmounted parity group or external volume group specified, the
command was supposed to be rejected with SSB that indicated that the
resource could not be migrated because it was not mounted, but the
command rejected with SSB=2ECA and FEEC indicating an internal
error, instead.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a resource migration command (raidcom add
resource, raidcom delete resource) is executed while specifying an
unmounted parity group or external volume group.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN

22 Unrecognized impact on host I/O performance by quick


format
Phenomena Users did not recognize that performing quick format might affect host
I/O performance.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a user performs quick format.
Causes and Updates The micro-program has been modified to fix the problem.
A warning message to inform users that performing quick format may
affect host I/O performance is output on the Format LDEV window
from which quick format is executed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part Storage Navigator

HDS Confidential 15 of 71
23 Failure of license installation
Phenomena When a DT license key was installed, an error occurred (Storage
Navigator message 405-8204) and license status became [Installed
(Disable)].
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SM Function Install is performed on CL2.
(2) SVP reboot occurs during a period from when SVP message
ONL2370I appears and then [YES] is clicked until when INLINE
CUDG is completed.
(3) PS OFF and non-volatile PS ON are performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

24 A spike in I/O response of MP at IP address change


Phenomena When an IP address was changed (Set IP address), a spike occurred in
I/O response in an MP of an MPB.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following conditions are met at IP
address change (Set IP address).
(1) [SVP and DKC] is checked.
(2) [IP address] or [Subnet Mask] is changed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

25 Failure of LDEV creation when different emulation types


coexist
Phenomena When 3390-3 and 3390-3R were displayed in Base Emulation Type on
Parity Groups window of Storage Navigator, if Create LDEVs was
executed to install LDEVs, Storage Navigator message 20121-107022
was displayed and LDEV creation failed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the emulation type is changed to 3390-3R
under the condition that the emulation type is 3390-3 and there is no
volume, or the case vice versa.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 16 of 71
26 No display of Attribute column in Parity Group table on
Resource Group Properties window
Phenomena The Attribute column was not displayed in Parity Groups table on
Resource Group Properties window.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Resource Group Properties window is
displayed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-03-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP

27 Invalid display of micro-program versions on Maintenance


window
Phenomena When micro-program versions were displayed on Maintenance
window, they might be displayed as "00-00-00" in some cases.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when micro-program versions are displayed
on Maintenance window.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

28 Failure of planned PS OFF during host I/O processing


Phenomena While an I/O was issued from a host, if planned PS OFF was
performed, the PS OFF might be disabled. In this case, the following
messages were output.
Host side: 1OS071I.
DKC side: SIM=388F00, SSB= 1603, 80E6, and 5600. (SSB=5600
was continuously output.)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe connection.
(2) PAV is installed.
(3) Planned PS OFF is performed during I/O processing.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 17 of 71
29 WCHK1 after LDEV installation when different versions
micro-program are used
Phenomena When an LDEV was installed while different versions of micro-
program were used, WCHK1 occurred after the installation was
completed. (SSB=32FE and SIM=3073XX)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Different versions of micro-program; V03 and higher and earlier
than V03, are used in a storage system.
(2) LDEV installation or removal is performed.
Causes and Updates The micro-program has been modified so that the LDEV installation or
removal will end abnormally in this case.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

30 Incorrect PG usage rate when viewed via RM Lib


Phenomena Within the monitoring data collected via RAID Manager Lib, the parity
group usage rate might be 0% even when there was an I/O.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) An I/O is issued.
(2) Parity group usage rate is viewed via RAID Manager Lib.
(3) CHK1 or WCHK1 occurs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

31 No SNMP trap issued when specific SIMs are output


Phenomena When SIM= AC9000 (DB Validation error), 47FXYY (Volume
Migration Abnormal End), and 4821XX (PreStaging Abnormal End)
were output, SNMP trap was not issued.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a DB validation error, Volume Migration
abnormal end, or PreStaging abnormal end occurs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 18 of 71
32 ATS command time-out with SSBs output
Phenomena When an ATS command and an UNMAP command were executed for
the same page at the same time while SOM905 was set to ON, the ATS
command turned time-out and SSB=D034 which meant command
time-out and SSB=14DC which meant time-out to wait for internal
resource were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) SOM905 is set to ON.
(2) A DP-VOL is in Simplex status.
(3) An ATS command is issued to the DP-VOL.
(4) An UNMAP command is issued to a range that contains the target
page of the ATS command.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

33 No action code in SIMs


Phenomena When Volume Migration ended abnormally (SIM=47FXYY (X= 4 to
F)), or status change to S-VOL (PAIR to COPY) was received from
MCU side (SIM=D9FXYY), a SIM action code was not generated but
remained blank.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Volume Migration ends abnormally or
status change to S-VOL (PAIR to COPY) is received from MCU side.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

34 Failure of port switch with SSB=B100 output


Phenomena At Hyperswap, port switch failed and SSB=B100 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Port type: RCU Target
(2) An operation to switch port automatically, such as Hyperswap, is
performed.
Causes and Updates The micro-program has been modified to recover the failure at port
switch to correctly determine port switch.
Also, the information for port switch judgment when port switch fails
is collected by using SSB=B10C and dump.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy, TrueCopy for Mainframe
Changed Part DKCMAIN

HDS Confidential 19 of 71
35 No data check error occurs for write I/O of invalid data for
Database Validator
Phenomena When volatile activation was performed after PS OFF while Database
Validator was set, a data check error did not occur for a write I/O of
invalid data for the Database Validator even though there was setting
information of Database Validator on CCI.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Database Validator is set to LDEV# 0x8000 to 0xfeff.
(2) One of the following operations is performed.
(a) PS OFF
(b) DKCMAIN configuration change
(3) One of the following operations is performed.
(a) Offline micro-program exchange
(b) Volatile activation
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

36 SSBs output at RCU registration


Phenomena When RCU registration command (raidcom add rcu) was executed and
then raidcom get command_status was executed, one of the following
SSB sets was output.
(1) SSB=2E22 and 3001
(2) SSB=2E23 and 3000
(3) SSB=2E22 and 3300
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following condition is met.
(1) SSB=2E22 and 3001: At RCU registration with CU restriction,
RCU is registered while specifying a storage system type that is
different from the already registered RCU.
(2) SSB=2E23 and 3000: While 4 RCUs are already registered to
MCU, another RCU is registered to the same MCU.
(3) SSB=2E22 and 3300: An RCU is registered with SSID specified
which is used by another RCU .
Causes and Updates The micro-program has been modified to fix the problem.
SSBs to be output in each case change as follows.
(1) SSB=2E22 and 3001 => 2E00 and 3008
(2) SSB=2E23 and 3000 => 2E22 and 3002
(3) SSB=2E22 and 3300 => 2E00 and 3008
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN

HDS Confidential 20 of 71
37 Frequent link-down in host path with SSB=B60D output
Phenomena When a UVM path was blocked and then a UVM VOL was blocked,
link-down frequently occurred in a host path and SSB=B60D was
output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a large number of ABTSs from a host occur
due to disconnection of external path or volume blockage.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

38 Unable to select multiple editable SSIDs to edit


Phenomena On Edit SSIDs window of Storage Navigator, only a single editable
SSID could be selected to edit.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when editing SSID on Edit SSIDs window of
Storage Navigator.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

39 Plateau of XRC performance


Phenomena If MP usage rate increased when the XRC MULTI READER function
was used, the performance of XRC function plateaued.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the XRC function is used.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Compatible XRC
Changed Part DKCMAIN

40 Failure of PDEV replacement/installation after SAS-port or


PDEV-port blockage
Phenomena After a SAS-port or PDEV-port was blocked, the PDEV recovery
failed and PDEV replacement/installation might fail.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when the recovery of PDEV
replacement/installation is running right after a SAS-port or PDEV-
port is blocked with failure.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 21 of 71
41 Failure of increase of the number of IU Pacings by Extended
Distance FICON
Phenomena Phenomenon1
During I/O processing with the micro-program of V03+1 while the
number of IU Pacings was increased to 64 by Extended Distance
FICON function, the number of IU Pacings decreased to 16.
Phenomenon2
When the micro-program was exchanged from earlier than V03+1 to
V03+1, the number of IU Pacings expanded by Extended Distance
FICON function was not increased to 64 but remained 16.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) There is a CMF PCB in the storage system.
(2) FNP attribute is set to the CMF PCB.
(3) One of the following operations is performed.
(a) Online micro-program exchange within V03+1 range or from
earlier than V03+1 to V03+1.
(b) MPB installation (Micro-program version is V03+1)
(c) MPB replacement (Micro-program version is V03+11)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

42 UR dump information wrongly collected even without


TC/UR SM function definition
Phenomena In a storage system where TC/UR of SM function was not defined,
dump information of UR/URz was collected.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) TC/UR of SM function is not defined.
(2) SM dump is collected.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 22 of 71
43 Failure suspension of TCz/URz pair
Phenomena Phenomenon1
CMF PCB removal on RCU of TCz or URz was not guarded, and all
of CMF PCBs became blocked or unmounted, which might result in
failure suspension.

Phenomenon2
While all of CMF PCBs were blocked or not mounted, pair creation
was not guarded but enabled, which might result in failure suspension.

In both cases, SIM= D46X (TCz) and DC0X (URz), and SSB=ED6A
were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TrueCopy for Mainframe or Universal Replicator for Mainframe
(2) All CMF PCBs are blocked or removed.
(3) There is one of the following volumes in DKC.
(a) TCz S-VOL whose emulation type is 3390-A. (Common to DP and
non-DP)
(b) URz S-VOL.
(4) The pair status is not Suspend. (Mirror status is not Stop)
Causes and Updates The micro-program has been modified to fix the problem.
In the case of phenomenon 1, SVP message SVP4341E will be output.
In the case of phenomenon 2, Storage Navigator message 6005-78066
will be output.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy for Mainframe, Universal Replicator for Mainframe
Changed Part DKCMAIN

44 Invalid Audit Log format after tiering policy setting


Phenomena When a tiering policy (previously tier level) was set in Edit Tiering
Policy operation, the format of Audit Log became invalid.
In particular, colons were changed to commas.
For example, [LDKC:CU:LDEV] was [0x00,0x00,0x00].
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a tiering policy setting is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP for Open: 70-02-53/00 and higher
SVP for Mainframe: 70-03-01/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part SVP

HDS Confidential 23 of 71
45 Unable to accept host I/O after recovery from system
configuration failure due to wrong cable connection
Phenomena When a system configuration failure due to incorrect cable connection
was recovered, an I/O from a host might not be accepted even though
SVP window showed that LDEV status was normal. SSB=D054 was
output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) PS ON is performed with a wrong cable connection between SSWs.
(2) The wrong connection is corrected and the system is recovered by
SSW or DKA replacement.
(3) After the above, a host I/O is issued without performing PS OFF
and ON.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

46 Wrong SSBs output when DKC logical inconsistency occurs


Phenomena When a DKC logical inconsistency error occurred, SSBs were
supposed to be reported to a host by EQC, but an SSB that was output
only when "set special interrupt condition" command was issued was
reported (FM=x0F, RC=x80).
SSBs to be output in this case are as follows.
7225, 7EE3, 7E4A, 7451, 749D, 7D85, 7DBF, 7DB9, 747F, 7491,
7362, 7351, 7342, 7381, 7371, 73A1, 7391, 7D53, 7D04, 7D27, 491C,
C02E, 47C3, 47C3, 47C3, 4B6F, 4E95
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) One of the following commands which may cause special
interruption condition check to be returned is executed.
(a) DIAGNOSTIC CONTROL (F3)
(b) LOCATE RECORD EXTENDED (4B)
(c) Perform Subsystem Function (27)
(d) Set Cache Storage Mode (87)
(2) Internal logical inconsistency occurs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 24 of 71
47 Failure of PDEV/SSW/DKA replacement
Phenomena If a type name of spare drive was displayed as "????????" on Refer
Configuration window, replacement of PDEV of the spare drive or that
of SSW/DKA to which the spare drive belonged failed and SSB=A7E1
was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) An SSD drive is used as a spare drive.
(2) Drive copy to the spare drive is executed.
(3) PS OFF and ON is performed while the spare drive is used as a
copy target of data drive.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

48 Error by FC operation or ShadowImage Initialize


Phenomena After PS OFF or power outage during ShadowImage Initialize and then
non-volatile activation, when one of the following operations was
performed, an error occurred.
(1) FC operation (SSB=9639)
(2) ShadowImage Initialize (Storage Navigator message 7105 8525)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) The storage system is powered OFF or a power outage occurs
before the completion of ShadowImage Initialize. (* Operation order
does not matter)
(2) After the storage system stops, non-volatile activation is performed.
(3) After the storage system is activated, an FC operation or SI
Initialize is performed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category FlashCopy version2
Changed Part DKCMAIN

49 Permission failure if multiple users log in CCI at same time


Phenomena When 2 users who used CCI logged in at the same time, their
permissions which should have been different became identical. As a
result, operations each of them had been originally allowed were
disabled or those each of them had been not originally allowed were
enabled.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Multiple users who use CCI log in at the same time.
(2) A reset occurs by a command executed from CCI by a user other
than the above.
Affected Products/Version DKCMAIN: 70-02-73-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN

HDS Confidential 25 of 71
50 Temporary high MP usage rate
Phenomena Immediately after background copy started, the MP usage rate
temporarily went over 80% and I/O response degraded.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when the following condition is met.
(1) Background copy for multiple FC pairs is executed at the same
time. (Executing Withdraw while DDSW=YES is specified, or
Establish is executed in copy mode)

(The problem is more likely to occur if the volume size or the number
of FC pairs is large.)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category FlashCopy version2
Changed Part DKCMAIN

51 No display of tier range when lane is set


Phenomena Because CCI did not support a command to refer to tier range per lane
for a DT pool, the range when the lane was set could not be displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when DT pool information is obtained by CCI.
Causes and Updates The micro-program has been modified so that tier range per lane can
be displayed at HDT pool information acquisition with a pool ID
specified.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN

52 Failure of CM maintenance if MP is blocked due to WCHK1


during maintenance
Phenomena If an MP was blocked due to WCHK1 during CM maintenance, the
CM maintenance might fail.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) One of the following operations is in progress.
(a) CM maintenance
(b) CM failure blockage
(c) PS OFF
(d) PS ON
(2) Some MPs in an MPB is blocked. (Except a case that 4 MPs in the
MPB are blocked.)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open of Mainframe
Changed Part DKCMAIN

HDS Confidential 26 of 71
53 SSB=1479 output by CM failure blockage during CM
recovery processing
Phenomena During CM recovery processing, if CM failure blockage occurred on
the side being recovered, SSB=1479 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) CM recovery processing is executed.
(2) CM failure blockage occurs on the side being recovered.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

54 SSBs output by SELRST or CANCEL during Mainframe I/O


processing
Phenomena If SELRST or CANCEL occurred during Mainframe I/O processing,
SSB=5901, 5902, and 5865 were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe I/O
(2) SELRST or CANCEL occurs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

55 Invalid access with SSB=5839 output


Phenomena If CHK2 occurred during LDEV format or while FDM was used,
invalid access might occur and SSB=5839 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) LDEV format is performed or FDM is used.
(3) CHK2 occurs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 27 of 71
56 No display of some items on Detail dialog box
Phenomena When an SI, SIz, or Snapshot pair was selected and Detail dialog box
was opened on Storage Navigator sub-window, items that were
displayed on Pair Operation window such as copy pace and Svol mode
(SI)/Tvol mode (SIz) were not displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an SI, SIz, or Snapshot pair is selected and
Detail dialog box is opened on Storage Navigator sub-window.
Causes and Updates The micro-program has been modified to fix the problem.
ShadowImage: Copy pace and Svol mode are added to display on
Detail dialog box.
ShadowImage for Mainframe: Copy pace, Tvol mode, Relationship are
added to display on Detail dialog box.
Snapshot: Svol mode is added to display on Detail dialog box.
Affected Products/Version SVP: 70-03-33/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category ShadowImage, ShadowImage for Mainframe, Copy-on-Write Snapshot
Changed Part SVP

57 Wrong output of SSB=147F at MP blockage


Phenomena When an MP was blocked (MP failure blockage or micro-program
exchange), SSB=147F was wrongly output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) There is a blocked MP in a normal MPB. (MP failure blockage or
micro-program exchange)
(2) There is an LDEV of RAID1.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

58 Invalid error type occurrence


Phenomena When there was an error in the extension parameter specified in an
HPF I/O (Prefix (xE7)) command, a file protector error (FM=x00)
occurred (SSB=6788) instead of a parameter error (FM=x04).
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe host connection
(2) HPF PP (Compatible High Performance Connectivity for FICON)
is already installed.
(3) There is an error in the extension parameter specified in an HPF I/O
(Prefix (xE7)) command.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 28 of 71
59 Invalid display of device encryption status
Phenomena Even though encryption was enabled for a device, when DEVSERV
QDASD command was executed from a Mainframe host,
ENCRYPTION (YES/NO) = "N" was displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe connection
(2) Encryption is enabled for a device.
(3) DEVSERV QDASD command is executed from the Mainframe
host to the device.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

60 Failed to enable Read/Write OFFLINE VOL function


Phenomena In TPF configuration, if a TCz/URz pair was created using a VOL that
received a command from a host or a VOL that processed the
command, Read/Write OFFLINE VOL function could not work.
If the former VOL was used for a TCz/URz pair, SSB=4F36 was
output.
If the latter VOL was used for a TCz/URz pair, SSB=4F37 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a TCz/URz pair is created using one of the
following volumes.
(1) A VOL that receives a command from a host.
(2) A VOL that processed the command.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-36-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

61 SSB=3941 output even when command ends normally


Phenomena When a raidcom modify journal command was executed from CCI, the
command ended normally but SSB=3941 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a raidcom modify journal command is
executed from CCI while specifying one of the following options.
- Data overflow monitoring time
- Cache mode
- Timer type
- Path block watch
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-33-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN

HDS Confidential 29 of 71
62 Display failure when Multi-Tier Pool setting changed to
Enable
Phenomena Phenomenon1
When a DP pool was selected and Multi-Tier Pool setting was
switched to Enable on Edit Pools window of Storage Navigator, Buffer
Space for New page assignment and Buffer Space for Tier relocation
were displayed in blank.
Phenomenon2
When a DP pool and a DT pool were selected and Multi-Tier Pool
setting was switched to Enable on Edit Pools window of Storage
Navigator, Cycle Time, Monitoring Period, Monitoring Mode, Buffer
Space for New page assignment, and Buffer Space for Tier relocation
were displayed in blank.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following operations were performed on
Edit Pools window of Storage Navigator.
Phanomenon1
A DP pool is selected and Multi-Tier Pool setting is switched to
Enable.
Phenomenon2
A DP pool and a DT pool are selected and Multi-Tier Pool setting is
changed to Enable.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-53/00 and higher (DP, DPz and DT), 70-03-01/00 and
higher (DTz)
Fixed Product/Version SVP: 70-04-01/00
Category Dynamic Provisioning, Dynamic Provisioning for Mainframe,
Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part SVP

63 No display of write I/O "Received"


Phenomena When a write I/O was issued to a UR S-VOL while the pair was
suspended and "Enable" was set to S-VOL Write, "Received" for the
write I/O did not appear on Storage Navigator or BCM.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Universal Replicator for Mainframe pair
(2) The URz pair between P-VOL and S-VOL is suspended.
(3) SOM20 is set to ON or S-VOL Write is "Enable".
(4) A write I/O is issued to the S-VOL.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 30 of 71
64 Failure of Detail button
Phenomena When a task of Stop Shrinking in Failed status was selected on Tasks
window of Storage Navigator and then task status was displayed,
"Detail" button did not work.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a task of Stop Shrinking in Failed status is
selected, task status is displayed, and then Detail button is clicked.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP for Open: All
SVP for Mainframe: 70-02-53/00 and higher (DPz), 70-03-01/00 and
higher (DTz)
Fixed Product/Version SVP: 70-04-01/00
Category Dynamic Provisioning, Dynamic Provisioning for Mainframe,
Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part SVP

65 Delay in response due to conflict between I/O and processing


for monitoring
Phenomena When a conflict occurred between a host I/O and a processing while
monitoring status was During Computation, the response was delayed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Dynamic Tiering or Dynamic Tiering for Mainframe is used.
(2) Monitoring status of the pool is “During Computation”.
Affected Products/Version DKCMAIN for Open: All
DKCMAIN for Mainframe: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN

66 Incorrect pool information display


Phenomena The displayed pool information of tier relocation function was
incorrect.
In particular;
Storage Navigator: Scale of IOPH (vertical axis) of frequency
distribution graph was enormously large.
CCI: The displayed TL_Range that was a result of command to refer to
the pool information (raidcom get dp_pool -key opt) was different
from the actual value.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) In multiple tiers configuration, the drive type of tier1 is SSD.
(2) SOM901 is set to ON.
(3) The number of used pages of DP-VOL whose tier level is 1 is
larger than the capacity threshold of tier1.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN

HDS Confidential 31 of 71
67 Indirect (two-step) page relocation from tier3 to tier1
Phenomena During page migration from tier3 to tier1 in tier relocation processing,
pages might be migrated from tier3 to tier2 and then tier2 to tier1
(taking 2 steps) in some cases.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) 3-tier configuration
(2) A DP-VOL whose tier policy setting is level2.
(3) Pages in tier3 are relocated to tier1.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN

68 Failure of command execution after interruption by MP reset


Phenomena After asynchronous commands were executed in series from CCI, if
the processing was interrupted by a rest, the specified command could
not be executed and the following commands which were received
were not executed too.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when an MP reset occurs while asynchronous
commands are executed in series.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN

69 ICC and CHK2 by execution of RD TRAKCK DATA


command
Phenomena When RD TRACK DATA command was executed with 16CCW or
more data chains, ICC with HTLOG=1870 and CHK2 with SSB=5865
may occur.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe
(2) RD TRACK DATA (command code: A6) is executed with 16CCW
or more data chains.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 32 of 71
70 SSB=5321/5322 output at CMF PCB installation
Phenomena When a CMF PCB was installed, SSB=5321 and 5322 were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when a CMF PCB is installed on a system
where no CMF PCB is installed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

71 Failure of sending test message to syslog server


Phenomena A syslog server setting was done with "Send a test message" checked
on Edit SIM Syslog Server Settings window of Storage Navigator, but
a test message was not sent to the syslog server and SIM Syslog of
Service was not logged.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when any operation is performed without
changing syslog server setting.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-53/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP

72 Write PIN slot occurrence when SSW of the 2nd DKU BOX
is removed
Phenomena When SSW of the 2nd DKU-BOX was removed while SOM797 was
set to ON, a write PIN slot occurred and SIM=EF4X-XX
(XX=LDEV#) and SSB=1B10, 1B60, and A4C2 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SOM797 is set to ON.
(2) An SSW failure occurs in one of DKU boxes from the 2nd to the
last.
(3) I/O overload.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 33 of 71
73 Frequent SIM output when SSW is removed during I/O
processing
Phenomena When an SSW was removed during I/O processing, SIM=DF7X-YY
(X-YY=C/R#) indicating a drive port temporary failure was output 26
times.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) An SSW failure occurs in DKU boxes from the 2nd to the last.
(2) I/O overload.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN

74 Invalid MP usage rate displayed


Phenomena When MP usage rate was displayed on the performance monitor, the
rate during the time period of power OFF was displayed as 0%.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The monitoring switch is turned ON and performance monitoring
data is collected.
(2) During (1), there is a time period that the performance monitoring
data cannot be collected due to power outage.
(3) One of the following is performed. (a time period that the
performance monitoring data cannot be collected is essential in the
display hours)
(a) MP usage rate is displayed on the performance monitor of Storage
Navigator.
(b) Monitoring data is displayed by using Export tool while “group
PhyProc” described in the command file at activation.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Performance Monitor
Changed Part SVP

75 Unable to confirm SAS port blockage


Phenomena After a SAS port on CL1/ST was blocked with failure without data
I/O, if failure blockage occurred in a SAS port on CL2/ST, the latter
blockage of the SAS port on CL2/ST could not be confirmed.
SIM=CF11-XX, CF12-XX (XX=SAS port number)
SSB=A4B0, A491, A06B
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) No data I/O
(2) Both CL1 and CL2 sides of pair SAS ports are blocked.
(3) A SAS port failure except the top port between DKA and DKU
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 34 of 71
76 SSD model name erased after replacement
Phenomena While an SSD without model name was mounted on a CPK, when
another SSD in the same CPK was replaced and then the CPK was
replaced, the model name of latter SSD was erased.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The CMBK version is earlier than 70-72-55
(2) An SSD in a CPK that contains another SSD without model name
is mounted is replaced.
(3) The SSD or CPK is replaced.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

77 Pair suspend again after resync operation following pair


suspend
Phenomena Immediately after suspend operation was performed for a TC/TCz pair
or failure suspend occurred in the pair, if a resync operation was
performed, the pair was suspended again.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TrueCopy or TrueCopy for Mainframe.
(2) Immediately after pair suspend, a resync operation is performed for
the suspended pair.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy, TrueCopy for Mainframe
Changed Part DKCMAIN

78 SSB=DDA6 output during I/O processing in AIX host


connection environment
Phenomena During I/O processing in AIX host connection environment,
SSB=DDA6 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) An AIX host is connected.
(2) An event by which Check Condition is returned to the host occurs.
(Such as that results in SSB=D051 output)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 35 of 71
79 SSB=5AD2 output at recovery of pool associated with TSE-
VOL
Phenomena After operations from pool initialization through pool recovery were
performed in accordance with the procedures of WEB03-170 and
TRBL20-100, and a TSE-VOL became normal condition, when
VOLSER was set, SSB=5AD2 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when a pool with which a TSE-VOL is associated
is recovered.
Affected Products/Version DKCMAIN: 70-02-70-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Flash Copy SE
Changed Part DKCMAIN

80 Repeated link-up and link-down with SIM/SSB output in


HTP by link failure
Phenomena When a link failure occurred and link-up and link-down repeatedly
occurred in an HTP port that was linked up, the HTP port might be
blocked and SIM=21A3XX and SSB=7A39, 7A30, and 5331 were
output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe host connection.
(2) A path is connected to an HTP port and the port is linked up.
(3) In the HTP port, a link failure (such as cable failure, cable
connection failure and SFP failure) occurs and link-up and link-down
repeatedly occur.
Affected Products/Version HTP: All
Fixed Product/Version HTP: 70-04-06
Category Mainframe
Changed Part HTP

81 Host message IOS071I output when host PAV mode is


changed
Phenomena When host PAV mode is changed, IOS071I (START PENDING) was
output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe host connection.
(2) Host PAV mode is set to Compatible PAV mode or Hyper PAV
mode.
(3) One of the following commands to switch PAV mode is executed
from the host during I/O processing.
- SETIOS HYPERPAV=NO (Switching to Compatible PAV mode)
- SETIOS HYPERPAV=YES (Switching to Hyper PAV mode)
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 36 of 71
82 Failure of Create LDEVs with Storage Navigator error 3305-
001035
Phenomena When Create LDEVs was performed from Storage Navigator, the
processing failed and Storage Navigator error 3305-001035 occurred.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Delete LDEVs is performed to delete all LDEVs in a CU#.
(2) Before the completion of the above task, Create LDEVs including
the same CU# is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP

83 Failure in option cache PCB replacement performed after


power outage and PS ON
Phenomena During an internal processing associated with an Option Cache PCB
failure, a power outage occurred in DKC. After that, when the Option
Cache PCB was replaced following PS ON, the replacement failed and
SVP message [ONL2288W] and [ONL2412E] was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Basic Cache PCB is in normal condition.
(2) Option Cache PCB or any of Cache Module Group is blocked.
(3) An internal processing such as destaging the data on the cache, or
recreation of directory is in progress.
(4) PS ON after the power outage.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

84 SSB=3332 after installation or removal of parity group from


Install window of SVP
Phenomena When installation or removal of a parity group was performed from
Install window of SVP, SSB=3332 might be output in rare cases.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur in rare cases when all the following conditions
are met.
(1) Installation or removal of a parity group is performed from Install
window of SVP.
(2) Within a few seconds after closing the Install window, the window
is opened again.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-03-01/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 37 of 71
85 Incorrect message display when invalid value is entered for
WWN name
Phenomena When an invalid value was entered in a text field for WWN name on
Add New Monitored WWNs window or Edit WWN window and then
a user focused out (selected another item), the following Storage
Navigator message was displayed.
"The form of Host Group Name is wrong. Please input the
alphanumeric character and the
sign (except \ / : , ; * ? " < > |) within 64 characters."
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an invalid value is entered in a text field for
WWN name on Add New Monitored WWNs window or Edit WWN
window and then a user focuses out. (Select another item)
Causes and Updates The micro-program has been modified to fix the problem.
The message is corrected as follows.
"The form of WWN name is wrong. Please input the alphanumeric
character and the
sign (except \ / : , ; * ? " < > |) within 64 characters."
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP

86 Read command EQC indicating Write command rejection.


Phenomena When a TSE VOL (or FCSE VOL) pool was full, a read processing
might turn out to be EQC (SSB=5AD2, F48D, and F48C) indicating
Write command rejection.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
[TSE VOL (Simplex)]
(1) Mainframe
(2) TSE VOL
(3) TSE VOL pool is full.
(4) A read command is issued to the TSE VOL.

[FCSE]
(1) Mainframe
(2) FCSE pair is created.
(3) Target VOL (T-VOL) pool is full.
(4) A read command is issued to the T-VOL.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-70-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 38 of 71
87 No output of SSB=B6BE and no change of time-out value
even when HMO67 is ON
Phenomena Even though HMO67 was set from OFF to ON, SSB=B6BE was not
output and the E_D_TOV value was not changed from 2sec to 20sec.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) HMO67 setting is changed for other than host group#0.
(2) A port whose HMO67 setting is changed is Target or RCU_Target.
(3) Fabric of a port whose HMO67 setting is changed is OFF.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-80-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

88 SSB=E703 output
Phenomena SSB=E703 might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when one of the following operations is
performed during relocation or a processing to fix monitoring data.
(1) Pool shrink
(2) Pool expansion (only cases that the number of tiers increases.)
(3) Setting change of multiple tier pools from ON to OFF
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN for Open: All
DKCMAIN for Mainframe: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN

89 Taking time to display expanded Ports/Host Groups tree


Phenomena When logging into Storage Navigator from a user with meta resource
allocated and [Ports/Host Groups] tree was expanded, it took 1 minute
or longer to display.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs
(1) There are many ports and host groups.
(2) A user with resource allocated logs into Storage Navigator.
(3) [Ports/Hosts Groups] tree is expanded.
At the customer site where the problem occurred, the number of ports
was 128, and the number of host groups is 31590.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 39 of 71
90 Audit log information file initialization at SVP activation
Phenomena At SVP activation, SSB=3359 was output and an audit log information
file was initialized.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a conflict of accesses to an audit log
information file occurs at SVP activation.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

91 No output of error code in audit log


Phenomena When [AOU-VOL option information setting] was executed, if an
error occurred with Storage Navigator message 3005-6036 output, the
error code was not output in the representative log of audit log.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when V-VOL option setting is performed and
Storage Navigator error message 3005-6036 is output.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP for Open: 70-02-53/00 and higher
SVP for Mainframe: 70-03-01/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part SVP

92 No display of "Total" for total error count on Threshold


Counter Display dialog box
Phenomena On Threshold Counter Display dialog box of Information, "Total" for
the total error count was not displayed above the column of threshold.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Threshold Counter Display dialog box of
Information is displayed.
Affected Products/Version SVP: 70-03-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

93 Misaligned display of binary data and its contents


Phenomena On Content-SSB dialog box of Information, positions of binary data
display and "CTRL Data", "SSB Data" and "Internal Data" which
indicated the contents of the binary data were not correctly aligned.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Content-SSB dialog box is displayed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 40 of 71
94 Inconsistency between item and content
Phenomena On "Threshold Counter Display" dialog box of Information, items and
their contents did not match as follows.
(1) For "Mechanical error (unrecovered)", error count and threshold of
"SAS I/F error Port 0" were displayed.
(2) For "Media error (unrecovered)", error count and threshold of
"Mechanical error (unrecovered)" were displayed.
(3) For "Read/Write error (unrecovered)", error count and threshold of
"Media error (unrecovered)" were displayed.
(4) For "Drive I/F error (unrecovered)", error count and threshold of
"Read/Write error (unrecovered)" were displayed.
(5) For "Controller hardware error (unrecovered)", error count and
threshold of "Drive I/F error (unrecovered)" were displayed.
(6) For "SAS I/F error Port 0", error count and threshold of "Controller
hardware error (unrecovered)" were displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when communication to DKC executed when
displaying Threshold Counter Display dialog of Information fails.
(When the communication fails, "Unknown" is displayed for the
"Today" error count and threshold)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-03-33/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

95 Unintentional cancel function by pressing "C" key on


keyboard
Phenomena During DKCMAIN offline micro-program exchange, when "C" key
was pressed on a keyboard while a message "Now MP Rebooting ---
1/1" was displayed, SVP message SMT2681 ([Cancel] was selected.
Do you want to stop microprogram exchange?) appeared.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) DKCMAIN micro-program exchange is performed. (online or
offline)
(2) "C" key is pressed on a keyboard while a message "Now MP
Rebooting ----" is displayed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 41 of 71
96 TPF host message CYED0061W output when MPLF
function is used
Phenomena While MPLF function of TPF was used, TPF host message
CYED0061W might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TPF host connection
(2) MPLF function is used.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-36-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

97 Abend of zero data page reclamation or rebalance due to


WCHK1/CHK1
Phenomena If WCHK1 or CHK1 occurred during zero data page reclamation or
rebalance processing (pool expansion, pool shrink, or tier relocation),
the processing might end abnormally. (SSB=AF70)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Zero data page reclamation or rebalance (pool expansion, pool
shrink, or tier relocation) is performed.
(2) WCHK1 or CHK1 occurs during the above processing.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN for Open: All
DKCMAIN for Mainframe: 70-02-54-00/00 and higher (DPz), 70-03-
01-00/00 and higher (DTz)
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Provisioning, Dynamic Provisioning for Mainframe,
Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN

98 Unable to perform PPC control at the setting rate


Phenomena When 0x80000000 (2147483648) or higher was specified for transfer
rate at PPC control setting, the PPC control was not performed at the
expected transfer rate.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A PPC setting is performed from Raid Manager LIB.
(2) The upper limit value for PPC control is specified by using the
transfer rate.
(3) 0x80000000 (2147483648) or higher is specified for the upper limit
value.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 42 of 71
99 Incompletion of CLPR setting
Phenomena CLPR setting (capacity change) did not finish. (A dialog box of
Loading …..remained displayed.)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) There is a blocked MPB.
(2) CLPR capacity is changed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

100 Incomplete configuration change disabling other operations


Phenomena Cache capacity of CLPR was changed from Virtual Partition Manager
on Storage Navigator sub window, but an MP was blocked and the
change was not completed. Due to the event, the window remained in
the status of waiting for the completion of configuration change and
could not be terminated, which disabled other operations including
maintenance.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when cache capacity is changed on Virtual
Partition Manager window while an MP is blocked.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Virtual Partition Manager
Changed Part SVP

101 SSB=AFE1 output during micro-program exchange


Phenomena During micro-program exchange, SSB=AFE1 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SOM872 is set to ON.
(2) Online micro-program exchange or MPB replacement is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Volume Manager
Changed Part DKCMAIN

HDS Confidential 43 of 71
102 Registered task disappears
Phenomena On Tasks window of Storage Navigator, a registered task disappeared.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) One of tasks listed below, which is being executed or in wait status,
is registered.
(2) SVP is rebooted.
- Format
- Shredding
- Edit encryption to request format operations
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open Volume Management, Virtual LVI
Changed Part SVP

103 Incorrect display for source VOL and target VOL when
FCv2/FCSE pairs exist
Phenomena In [CopyType-FCv2] and [CopyType-FCSE] columns on Replica
LDEVs window, and in [Compatible FlashCopy(R) V2] and
[Compatible Software for IBM(R) FlashCopy(R) SE] on LDEV
Properties window, "S" for source VOL (S-VOL) and "T" for target
VOL (T-VOL) such as "S-Normal", "T-Normal", and "ST-Normal"
were displayed as "P" and "S" respectively like "P-Normal", "S-
Normal", and "PS-Normal".
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when there is any FCv2 pair or FCSE pair.
Affected Products/Version SVP: 70-03-33/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP

104 Failure of CM replacement after MPB replacement in highly


loaded condition
Phenomena After MPB replacement in highly loaded condition (Write Pending
Rate was high), when CM was replaced, the replacement failed
because an MPB that could not reserve CM became the bottleneck.
(SVP message ONL2788E)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) An operation with ownership migration (MPB maintenance/failure,
LUSE combination/release, SI/SIz pair creation/release, Snapshot pair
creation/deletion, JNL VOL addition/deletion, ownership migration by
CCI/Storage Navigator) is performed.
(2) After the above operation, Write Pending Rate remains 70% or
higher.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

HDS Confidential 44 of 71
105 SSB=137E output and decrease in available cache capacity
Phenomena SSB=137E was output and available cache capacity might decrease.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Ownership migration is performed manually.
(2) Offline micro-program or volatile PS ON is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

106 Abend of DKAF micro-program exchange with SSB=1C26


output
Phenomena When DKCMAIN and DKAF were selected and then micro-program
exchange was performed, SSB=1C26 was output during DKAF micro-
program exchange and the exchange ended abnormally.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when one of the following conditions is met.
(1) DKCMAIN and DKAF are selected at the same time and micro-
program exchange is performed.
(2) DKCMAIN micro-program exchange fails and then back-end
maintenance is performed (such as DKA, SSW or PDEV replacement,
DKA, DKU, or PDEV installation, or DKA, SSW, or Exp micro-
program exchange)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

107 Failure of graph display of long-range usage rate


Phenomena When usage rate in long range of Performance Monitor was displayed,
a line of graph was not displayed even in a time period when an
operation was being performed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Monitor data is collected in long-range.
(2) Data is not collected in some time period. (such as power outage
and maintenance)
(3) To display usage rate in long-range on Performance Monitor of
Storage Navigator, the specified start time is in the above time period.
(the time specified is in the above time period for Export Tool too.)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Performance Monitor
Changed Part SVP

HDS Confidential 45 of 71
108 SSB=5600 output during I/O processing
Phenomena During I/O processing, SSB=5600 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe connection
(2) Compatible PAV is installed.
(3) An alias is added.
(4) An I/O is in process.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

109 Unable to identify in which relationship a failure occurs,


FCv2 or FCSE
Phenomena When a source VOL (S-VOL) of FCv2 and a source VOL (S-VOL) of
FCSE were the same VOL, if a failure occurred in FCv2 or FCSE
relationship, in which relationship the failure occurred could not be
identified on Storage Navigator FCv2/FCSE main and sub windows.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) FCv2 S-VOL and FCSE S-VOL are the same VOL.
(2) A failure (full or failed) occurs in FCv2 or FCSE relationship.
(3) The status of VOL which is used as an S-VOL of FCv2 and FCSE
is confirmed on Storage Navigator FCv2/FCSE display window.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category FlashCopy version2, FlashCopy SE
Changed Part DKCMAIN

110 Unfinished task that restarts after SVP reboot


Phenomena When SVP was rebooted while a task was executed in Storage
Navigator, the task that restarted after the reboot could not finish.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when SVP is rebooted during one of the following
tasks is executed in Storage Navigator.
- LDEV creation (only when other than [No Format] is specified for
format type.)
- Tier relocation initiation
- Pool shrink
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 46 of 71
111 Session interrupted after SN message 20121-107025 output
Phenomena When a user logged into Storage Navigator and performed any window
operation, Storage Navigator message 20121-107025 was displayed
and a session was interrupted.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs in rare cases when any window operation of
Storage Navigator is performed.
Affected Products/Version SVP: 70-03-01/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

112 Imbalanced LDEV assignment


Phenomena When an ECC was added, LDEVs were not assigned to MPBs equally.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Before ECC installation, ownership is equally balanced in the
storage system.
(2) LDEVs are installed in the ECC in other than ascending order at
ECC installation.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

113 Failure suspend of delta UR/URz pair after TC/TCz pair


SSWS
Phenomena In 3DC multi-target configuration, when suspend was performed for
TC/TCz pairs with S-VOL specified, and an I/O was issued to L site
(TC/TCz S-VOL), the I/O stopped and delta UR/URz pair was
suspended with a failure. (SSB=EDD8 was frequently output.)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) 3DC multi-target delta configuration
(2) Following operations are performed in that order.
(a) An I/O is issued to P site.
(b) Suspend (SSWS) is performed for TC/TCz pairs with S-VOL
specified.
(c) An I/O is issued to L site.
(d) Reserve Resync is performed to TC/TCz pairs.
(e) Takeover is performed to TC/TCz pairs.
(f) Suspend (SSWS) is performed for TC/TCz pairs with S-VOL
specified. (The status of TC/TCz pairs is changing to SSWS and some
pairs still in Duplex status.)
(g) An I/O is issued to L site.
(h) An I/O is issued to P site.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 47 of 71
114 Link-down due to hardware failure during HMO51 setting
operation
Phenomena At HMO51 setting operation, if a hardware failure occurred (MPB,
CHT PCB failure, MP failure (CHK1B)), an access to internal
resources was disabled and link-down occurred. (SSB=B6FB)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) TC/TCz configuration.
(2) HMO51 is set to ON or OFF in RCU Target port.
(3) During the above setting operation, a failure occurs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-31-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy, TrueCopy for Mainframe
Changed Part DKCMAIN

115 Unable to stop Diagnosis


Phenomena When diagnosis was executed with Loop Limitless checkbox was
checked while A3 routine of Path INLINE was in progress, a dialog to
stop the processing could not be displayed because the Path INLINE
window was grayed out, and the operation was disabled.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SVP is set to Modify mode.
(2) Path INLINE is opened from Diagnosis.
(3) Diagnosis with A3 routine specified is executed while Loop
Limitless checkbox is checked.
Affected Products/Version SVP: 70-02-06/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

116 SN message modification


Phenomena When a pair resync operation was performed from primary data VOL
after forcible pair deletion was performed with secondary data VOL
specified, Storage Navigator message [6505-8701] was output but the
message did not contain information about a case that S-VOL was in
SMPL status.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Forcible pair deletion is performed from the secondary data VOL.
(2) A pair resync operation is performed from primary data VOL to a
pair whose secondary data VOL becomes SMPL status by the above
operation (1).
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part SVP

HDS Confidential 48 of 71
117 Failure of cache DIMM removal
Phenomena Cache DIMM removal failed with SVP message ONL2788E output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The message occurs when all the following conditions are met.
(1) DKC 1-module configuration.
(2) PS ON is performed while MPB is mounted on an added DKC
(operation mistake).
(3) Maintenance related to basic CM PCB is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open and Mainframe
Changed Part DKCMAIN

118 Reserve command takes 1 or more seconds to finish


Phenomena When a reserve command was issued during Flash Copy operation, the
processing might take 1 or more seconds to finish. In that case,
SSB=506F was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) A Flash Copy operation is in progress.
(3) A reserve command is received.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

119 SSB=1548/1588 output at creation of HDD-less configuration


Phenomena While Cache Residency Manage (DCR) was set, when an HDD-less
configuration was created by Define Configuration and Install,
SSB=1548 and 1588 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when one of the following conditions is met.
(1) From a configuration with Cache Residency Manage (DCR)
setting, an HDD-less configuration is created by Define Configuration
and Install.
(2) In an HDD-less configuration while DCR is set to an external
VOL, Define Configuration and Install is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Cache Residency Manage (Open or Mainframe)
Changed Part SVP

HDS Confidential 49 of 71
120 No guard for incorrect operation on the window
Phenomena At CM installation/removal, if CM capacity, Cache Residency Manage
(DCR) capacity, or the number of extents of CLPR1 to 31 was changed
without changing CM capacity, the operation was not guarded on the
window. After that, SVP message ONL0870I was output during the
later processing and the operation was disabled without operation
target.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) CM installation or removal is performed.
(2) One of the following operations is performed.
(a) At CM removal, CM capacity, Cache Residency Manage (DCR)
capacity, or the number of extents of CLPR1 to 31 is reduced without
reducing the CM capacity.
(b) At CM installation, CM capacity, DCR capacity, or the number of
extents of CLPR1 to 31 is increased after CM capacity is increased,
and then the CM capacity is turned back to the previous.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

121 TC/TCz pair operation time-out during operation to 2,048 or


more UR/URz pairs
Phenomena When a TC/TCz pair operation was performed to 2,048 or more
UR/URz pairs that were in a group operation, SSB=DDAF or D035
was output and the TC/TCz pair operation turned time-out.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TC/TCz or UR/URz
(2) A group operation, such as suspend, resync, pair deletion, is
performed to 2,048 or more UR/URz pairs.
(3) A TC/TCz pair operation is performed during (2).
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy, TrueCopy for Mainframe, Universal Replicator, Universal
Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 50 of 71
122 Blockage of MP at offline micro-program exchange or SM
volatile power ON
Phenomena Phenomenon1
During offline micro-program exchange of DKCMAIN, WCHK1
occurred, some MPs were blocked, and the exchange failed. (SVP
message SMT2433E and SSB=0005/0006 were output.)
Phenomenon2
When SM volatile power ON was performed, the system was activated
with some MPs blocked. (SSB=0005/0006 was output.)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The total capacity of DP/DPz/DT/DTz pools is 3.5PB or larger.
(2) Offline micro-program exchange or SM volatile power ON is
performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Provisioning, Dynamic Provisioning for Mainframe,
Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN

123 SSB=50C4 output at cache removal in TCz/FCv2


combination
Phenomena When cache was removed in configuration of TCz and FCv2
combination, SSB=50C4 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) TCz and FCv2 combination
(2) A cache failure occurs or cache maintenance is performed.
(3) A write or read I/O is issued to FCv2 source or target VOL.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy for Mainframe
Changed Part DKCMAIN

HDS Confidential 51 of 71
124 Page allocation to inadequate tier
Phenomena Even when the total capacity of tiering policy level1 could be
contained in Tier1, pages were allocated in Tier2 in some cases.
Even when the total capacity of tiering policy level3 could be
contained in Tier2, pages were allocated in Tier3 in some cases.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when any of the following conditions is met.
[When the number of tiers is 3]
(1) There are settings for Tiering Policy Level1, and Level2 or ALL in
a pool, and the following formula works:
The total capacity of level1 < tier1 capacity x depletion threshold < the
total capacity of level1 + the total capacity of level2 or ALL
(2) There are settings for Tiering Policy Level3, and Level4 or ALL in
a pool, and the following formula works:
The total capacity of level3 < tier2 capacity x depletion threshold < the
total capacity of level3 + the total capacity of level4 or ALL
(3) There are settings for Tiering Policy Level2 (which can be included
in Tier1) and ALL in a pool, and the following formula works:
The total capacity of Level2 < tier1 capacity × depletion threshold <
the total capacity of Level1 + the total capacity of ALL
(4) There are settings for Tiering Policy Level4 (which can be included
in Tier2) and ALL in a pool, and the following formula works:
The total capacity of Level4 < tier2 capacity x depletion threshold <
the total capacity of Level3 + the total capacity of ALL
[When the number of tiers is 2]
(5) There are settings for Tiering Policy Level1 and ALL in a pool,
and the following formula works:
The total capacity of level1 < tier1 capacity x depletion threshold < the
total capacity of level1 + the total capacity of ALL
Affected Products/Version DKCMAIN for Open: 70-02-54-00/00 and higher
DKCMAIN for Mainframe: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN

125 SAS port blockage with SIM and SSB output


Phenomena During a DKA electrostatic test, a SAS port was blocked and then SIM
for a temporary drive port failure was output.
SIM=CF12XX (X=SAS port#)
SIM=DF6XYY (X=CDEV#, YY=RDEV#)
SIM=DF7XYY (X=CDEV#, YY=RDEV#)
SSB=A40B
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) There is a data I/O.
(2) A DKA failure occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 52 of 71
126 Failure of dump collection
Phenomena At dump collection, an SVP message "Dump of the following
processors could not be done." appeared and the collection was
disabled.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the operation (2) is performed without
replacing the blocked CHA/DKA after the operation (1).
(1) Volatile activation while CHA/DKA are not inserted.
(2) Non-volatile power outage or non-volatile PS OFF and then power
ON while inserting the above CHA/DKA
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

127 Device file blockage with SSB=D055 output by Check


Condition response
Phenomena By a Check Condition response when a host I/O was received while a
DP pool was blocked, a device file was blocked on the host side and
SSB=D055 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A host I/O is issued to a DP VOL.
(2) The above DP pool VOL is blocked.
Causes and Updates New Host Mode Option 71 is available to switch sense key/sense code
to avoid device file blockage.

Public Mode – No Permission Required to Use


Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

128 SSB=9C88 output at page reclamation when cache is


overloaded
Phenomena When cache was overloaded, if page reclamation (such as an ERASE
command or batch page reclamation) was performed, SSB=9C88
might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Dynamic Provisioning for Mainframe
(2) Cache is overloaded.
(3) Page reclamation is performed. (such as an ERASE command or
batch page reclamation)
(4) VOL of CU#DEV#=00:00 is not mounted.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Provisioning for Mainframe
Changed Part DKCMAIN

HDS Confidential 53 of 71
129 Wrong Reservation Conflict response
Phenomena In Non Disruptive Migration (NDM) configuration, Reservation
Conflict wrongly occurred for a TestUnitReady, StartStopUnit, or
XCOPY command, and SSB=D5A8 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) NDM configuration
(2) An environment where Reserve is used. (Both of SCSI-2 Reserve
and Persistent Reserve)
(3) One of the following operations is performed.
(a) A TestUnitReady command is issued while Host Mode Option2 is
set to ON.
(b) A StartStopUnit command is issued while Start bit is ON.
(c) An XCOPY command is issued while Host Mode Option62 is set
to OFF.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

130 Delay in response to host when time-out occurs


Phenomena When a write request turned time-out while SOM15 or SOM862 was
set to ON, response to a host might be delayed.
(SSB=A4C2)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) SOM15 or SOM862 is set to ON.
(2) There is a data I/O.
(3) A command time-out failure occurs in a write request.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN

131 [EX_CMDIOE] Control command I/O error


Phenomena When a CCI command was executed, "[EX_CMDIOE] Control
command I/O error" occurred and all of CCI commands were rejected
by the same error.
SSB=1699 and 16A1
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met..
(1) Server Priority Manager control setting is performed.
(2) A command device is included in the targets of upper limit control.
(3) During I/O processing from the host of upper limit control target, a
CCI command is executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 54 of 71
132 Failure of filtering Total or Used capacity by cylinder
Phenomena On V-VOL tab on the top window displayed when an individual pool
was selected from Pool on Storage Navigator, when Capacity Total or
Used column was filtered by cylinder for capacity unit, it was not
filtered by cylinder.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs all the following conditions are met.
(1) A pool of Mainframe is displayed on V-VOL tab on the top
window displayed when a pool is selected from Pool on Storage
Navigator.
(2) Capacity Total or Used is filtered with cylinder specified for
capacity unit.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-53/00 and higher (DPz), 70-03-01/00 and higher (DTz)
Fixed Product/Version SVP: 70-04-01/00
Category Dynamic Provisioning for Mainframe, Dynamic Tiering for Mainframe
Changed Part SVP

133 Failure of DKCMAIN micro-program exchange in DKU-less


configuration
Phenomena When DKCMAIN micro-program was exchanged in DKU-less
configuration, SVP message SVP0732W appeared and the exchange
failed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) DKU-less configuration
(2) Maintenance window has never been opened.
(3) DKCMAIN micro-program is exchanged.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

134 WCHK1 in multiple existing MPs after MPB installation


failure
Phenomena At MPB addition, if the MPB was installed before SVP message
ONL0869I appeared, the installation failed and the MPB was blocked.
After that, if maintenance to recover the MPB was not performed,
WCHK1 (SIM=3180XY) might occur in multiple MPs in another
MPB.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) At MPB addition, the MPB is installed in the time period from 1
minute before a message (Download File [DKCMAIN]) appears on
SVP to 1 minute before the message disappears.
(2) Without recovering the MPB, the system is used.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

HDS Confidential 55 of 71
135 Devices unrecognized from host after Shut/No shut is
performed
Phenomena After Shut/No shut (to enable or disable port) was performed on a
switch port, login to a host failed and devices could not be recognized.
(SSB=BC29)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when Shut/No shut is performed on a switch port
connected with a CHG PCB (FCoE port).
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

136 WCHK1 with SSB=1644 output due to failure during I/O


processing
Phenomena When a failure occurred during I/O processing, WCHK1 occurred and
SSB=1644 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when any of the following failures occurs during
I/O processing.
- CHK1B
- CHK3
- CHK4
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-31-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

137 Host time-out with SSB=7A20 output at PDEV installation


during I/O processing
Phenomena When a PDEV was installed during I/O processing, ICC host time-out
occurred and SSB=7A20 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) There is a data I/O from a host.
(2) A PDEV is installed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 56 of 71
138 Unsupported platform contained in Readme file and
directory for Export Tool
Phenomena Unsupported platforms were mentioned in Readme file for
Performance Monitor Export Tool. A folder of HP-UX that was not
supported existed in the directory of PP media.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Export Tool of Performance Monitor is used
on Unix.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Performance Manager
Changed Part SVP

139 PIN slot display failure


Phenomena When PIN was displayed from SVP Maintenance window;
(1) HDEV# where PIN slots occurred was not displayed, or
(2) SSB=1609/13DE was output and PIN display failed when HDEV#
with PIN slots was selected and then Details was displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem (1) and (2) may occur when the following conditions (1)
and (2) are met respectively.
(1) There are PIN slots. The problem is more likely to occur if there are
many PIN slots.
(2) PIN slots exist in a HDEV with capacity of over 3TB.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

140 Failure of command to cancel SPM setting


Phenomena When delete spm_wwn was executed while the license of Server
Priority Manager (SPM) expired, a message "The program product is
not installed" appeared and the command failed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Server Priority Manager is not installed or its license is expired.
(2) The SPM setting is canceled from CCI.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 57 of 71
141 Performance degradation of TC/TCz, UR/URz, LDEV
Phenomena When TC/TCz or UR/URz was used or LDEV format was performed,
if an MP failure such as CHK3 repeatedly occurred in the same MP,
performance of I/O processing, TC/TCz, UR/URz, and LDEV format
might degrade and SSB=1042 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TC/TCz or UR/URz is used or LDEV format is performed.
(2) A failure reset (such as CHK3, CHK1B, CHK4 and hang-up reset)
occurs in an MP in an MPB having ownership of the LDEV used in
(1).
(3) The above failure reset repeatedly occurs in the same MP.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy, TrueCopy for Mainframe, Universal Replicator, Universal
Replicator for Mainframe
Changed Part DKCMAIN

142 Continuous ICC occurrence during read I/O from host


Phenomena During read I/O processing from a host, ICC might continuously occur.
In this case, SSB=1602 and 7A20 (HTP EC=4131 and 3301) were
output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) HPF on host side is ON.
(3) HPF is installed on RAID700 side.
(4) Ownership of each LDEV is distributed to multiple MPBs.
Affected Products/Version HTP: All
Fixed Product/Version HTP: 70-04-06
Category Mainframe
Changed Part HTP

143 WCHK1 due to LA error for P-VOL of SI/SIz pair


Phenomena When an LA error occurred during I/O processing to a P-VOL that was
a DP-VOL used in an SI/SIz pair in split copy processing, WCHK1
occurred and SSB=32FE, B2CB and SIM=3073 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) UVM is used.
(2) ShadowImage or ShadowImage for Mainframe is used.
(3) DP-VOL that is an external VOL is used as a pool VOL.
(4) An SI/SIz pair whose P-VOL is the above DP-VOL.
(5) Split copy is performed for the above SI/SIz pair.
(6) During the above processing, an I/O is issued to the SI/SIz P-VOL.
(7) During the above I/O processing, an ECC/LRC error occurs.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

HDS Confidential 58 of 71
144 SSB=14DC and 14FF output when external VOL is used
Phenomena When an external VOL was used, SSB=14DC and 14FF (waiting
timeout for resource) were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Volume Manager is used.
(2) Cache mode is ON in an external VOL.
(3) System Option Mode872 is set to ON.
(4) Sequential write I/O and random write/read I/O are issued to the
same VOL.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Volume Manager
Changed Part DKCMAIN

145 Failure of cache PCB replacement with SVP message


ONL2288W
Phenomena After cache PCB installation failed, replacement of the blocked cache
PCB failed and SVP message ONL2288W was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Cache PCB installation except Basic cache PCB.
(2) Before the target cache PCB on CL1 is recovered, a failure of Basic
cache PCB on CL1 occurs.
(3) Cache PCB installation on CL2 is stopped due to a CUDG error
that occurs because a required part fails or is not added.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

146 Continuous SSB=C470 output at TCz initial copy


Phenomena When TCz initial copy was performed while using a DP-VOL as a P-
VOL, SSB=C470 was continuously output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TrueCopy for Mainframe
(2) P-VOL is a DP-VOL.
(3) TCz initial copy is performed.
(4) Page reclamation is performed. (such as an ERASE command or
batch page reclamation)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy for Mainframe
Changed Part DKCMAIN

HDS Confidential 59 of 71
147 Invalid display of HDEV (DP) on result window when Verify
error occurs
Phenomena When a Verify error occurred in "Verify" processing for a pool VOL,
if the result window was displayed, an item of HDEV (DP) was
displayed by hyphen. It was also displayed by hyphen for a text file
output by Archive function.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Verify function is executed on Maintenance window.
(2) The above operation is performed for a pool VOL of Open
emulation to which DP-VOL is allocated.
(3) A Verify error occurs in the above pool VOL.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

148 MIH or host job time-out occurs with SIM=3073XX output


Phenomena During online micro-program exchange, if an MPB failure occurred
and resource in DKC could not be released, SIM=3073XX (MP
blockage) was output and MIH (MISSING CHANNEL AND DEVICE
END) or host job time-out occurred.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Online micro-program exchange is performed.
(2) An MPB failure occurs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

149 SSB=13F3 output and performance degradation


Phenomena SSB=13F3 was output and performance degraded.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when one of the following is included in
configuration.
(1) Mainframe system environment.
(2) SATA-E drives are used.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

HDS Confidential 60 of 71
150 Failure of CCI activation from remote command device
Phenomena When CCI was activated using a remote command device,
SSB=D07B/B98E or D07B/B98F were output and the activation
failed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Instance of CCI connected to a remote command device is
activated.
(2) Multiple CCI instance numbers or multiple server connection
WWNs are used.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN

151 SSB=992B output at drive failure during I/O processing


Phenomena During Mainframe I/O processing, if a drive failure occurred,
SSB=992B might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) An I/O is issued to a Mainframe VOL.
(2) RAID5 or RAID6
(3) SSD drives are used or MP usage rate is 80% or higher.
(4) A drive failure occurs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

152 Failure of PS OFF with SIM=338F-00 output


Phenomena After MPB removal, PS OFF might fail and SIM=338F-00 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) After PS ON, an MPB has been removed.
(2) MP stop by MPB removal and communication between SVP and
DKC occur at the same time. (extremely-low probability)
(3) PS OFF is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN

HDS Confidential 61 of 71
153 Inadequate Storage Navigator message
Phenomena At a pair addition from Storage Navigator, if a serial number different
from that corresponding to a registered mirror# was registered, Storage
Navigator message 6505 58040 (An internal error occurred.) appeared,
but the error could not be identified from the message. SSB=E8A2 was
also output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) UR Open or Mainframe
(2) The following operations are performed in that order.
(a) Creation of 2 or more pairs with the same JNLG# and same
mirror# is preset from Storage Navigator, and one of the two creating
operations is intentionally ended in failure.
(b) Another pair is successfully registered and the failed creation
remains in the preset.
(c) The pair in preset is edited to replace the serial number with an
invalid value and then pair registration is retried.

* JNLG# and mirror# set in (c) are the same as those in (a), and other
parameters are correct.
Causes and Updates The micro-program has been modified to output the correct Storage
Navigator message as follows in this case.
(6505-78270) Pair creation failed because the serial number, the
controller ID, and the path type of the specified secondary storage
system are invalid.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
SVP: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
SVP: 70-04-01/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

154 Invalid display state on CVS setting window


Phenomena While the maximum number of LDEVs (65280) was set in a storage
system, when free space was selected on CVS setting window, [Add]
button on the window wrongly became active. But if the [Add] was
clicked, LDEV could not be created.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Define Configuration and Install, PDEV installation, or CVS
(LDEV installation) is performed.
(2) The maximum number of LDEVs (65280) is set in a storage
system.
(3) Free space is selected on CVS setting window.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 62 of 71
155 No guard of reverse resync operation between I and R site
Phenomena In 3DC cascade configuration with 3 UR/URz sites, a reverse resync
operation for a pair between I site and R site after a pair between P site
and I site was suspended was not guarded.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Open or Mainframe
(2) 3DC cascade configuration with 3 UR/URz sites
(3) A pair between P site and I site is suspended.
(4) Reverse resync operation performed for a pair between I and R site.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

156 ICC occurs when MIH occurs in Mainframe environment


Phenomena When MIH occurred in Mainframe environment, ICC occurred. (HTP
LOG=1870)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) MIH occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

157 Failure suspension in UR/URz pair between P site and I site


by resync operation for the UR/URz pair
Phenomena In 3DC cascade configuration with 3 UR/URz sites, when a UR/URz
pair between P site and I site was suspended, a reverse resync
operation was performed for UR/URz pair between I site and R site,
and then a resync operation is performed for the UR/URz pair between
P site and I site, failure suspension occurred in the UR/URz pair
between P site and I site.
(SSB=ED00, ED2A, and ED2B)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Open or Mainframe
(2) 3DC cascade configuration with 3 UR/URz sites
(3) A reverse resync operation is performed for a UR/URz pair
between I site and R site while a UR/URz pair between P site and I site
is suspended.
(4) After the above operation (3), a resync operation is performed for
the UR/URz pair between P site and I site.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 63 of 71
158 Failure of IP address setting
Phenomena When an IP address was changed to 126.255.255.15 by Install-
SetIPAddress of SVP, if SVP was rebooted, the IP address became
169.254.xxx.xxx. After that, Storage Navigator could not be activated.
If the Maintenance window of SVP was opened, SVP message
STA0117E (An error occurred in the Communication between the SVP
and DKC.) appeared and DKC information could not be obtained.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when the same IP address exists on the same
network.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP

159 Failure of SSW replacement with SSB=4ACX/4A0X output


Phenomena SSW replacement failed and SSB=A4CX and A40X were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when an HDD failure occurs during SSW or DKA
replacement.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN

160 Increase in MP usage rate with SSB=14FF, 14DC, and 8956


output
Phenomena During I/O processing to a DP/DPz or DT/DTz VOL with which an
external VOL was associated as a pool VOL, if a pool VOL that was
an external VOL was added to the DP/DPz or DT/DTz VOL, MP
usage rate increased and SSB=14FF, 14DC, and 8956 were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Universal Volume Manager configuration
(2) An external VOL is used as a pool VOL.
(3) An I/O is issued to a DP/DPz or DT/DTz VOL associated with the
above pool.
(4) The type of the I/O is sequential write.
(5) System Option Mode872 is set to ON.
(6) A pool VOL that is an external VOL is added to the DP/DPz or
DT/DTz VOL during I/O processing.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Volume Manager
Changed Part DKCMAIN

HDS Confidential 64 of 71
161 Excessive time for status transfer at delta resync operation
Phenomena When a pair for delta resync was created and then a delta resync
operation was executed in 3DC cascade configuration with 3 UR sites,
the delta resync operation succeeded but some pairs took a longer time
for status transfer from Copy to PAIR compared to other pairs in the
mirrors.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open
(2) 3DC cascade configuration with 3 UR sites
(3) In a different configuration (other than above), the following
operations are executed.
(a) UR pair creation
(b) Suspend
(c) An I/O
(d) UR pair deletion
(4) After the above operations of (3), a UR pair for delta resync is
created in the configuration of (2).
(5) A delta resync operation is executed.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN

162 SSB=DD09 output at ABTS occurrence


Phenomena When ABTS occurred, SSB=DD09 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Host Mode Option51 is set to ON on MCU and RCU sides.
(2) There is a TC/TCz pair and TC/TCz path.
(3) ABTS occurs due to missing data frames and so on.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy, TrueCopy for Mainframe
Changed Part DKCMAIN

163 Unable to decrease JNL usage rate at S-site


Phenomena In 3DC multi-target (delta resync) configuration with 3 UR sites, even
when a host I/O to P-site was stopped, JNL usage rate at each S-site
did not decrease.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open
(2) 3DC multi-target (delta resync) configuration with 3 UR sites
(3) An operation to allocate remote command devices to all mirrors of
each P-site and S-site is executed on Journal Operation window.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN

HDS Confidential 65 of 71
164 SSB=D055 output every 10 minutes
Phenomena When a UNMAP command was issued to an area where a pool VOL
with DP/DT VOL allocated was blocked, SSB=D055 was output every
10 minutes.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a pool area of DP/DT-VOL that receives a
UNMAP command is blocked.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Provisioning, Dynamic Tiering
Changed Part DKCMAIN

165 Failure of FCSE relationship creation, leading to


Startpending/MIH
Phenomena FCSE relationship creation or deletion failed and SSB=F489, 96AF,
and 9617 were output.
If a TSE VOL was accessed while leaving the condition as was,
Startpending/MIH occurred and SSB=1602 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) FCSE relationship creation or deletion
(3) A target VOL is a TSE VOL.
(4) LDEV ownership is migrated.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-70-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN

166 SSB=48B3 and 481E output at update I/O


Phenomena When an update I/O was issued from a Mainframe host to a VOL that
was used as an FCv2 source VOL and as a UR primary VOL,
SSB=48B3 and 481E were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) A configuration in which FCv2 source VOL and UR primary VOL
share the same VOL.
(2) An update I/O that is a sequential access is executed for an un-
copied area of FCv2 source VOL.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category FlashCopy version2
Changed Part DKCMAIN

HDS Confidential 66 of 71
167 Failure of Long Range monitoring data backup
Phenomena For Long Range monitoring data of Performance Monitor, the
following phenomena (1) and (2) alternately occurred for each set of
monitoring data for 3 months.
(1) The data was not backed up in standby SVP.
(2) The data at 0:00 every day was not backed up.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Dual SVP configuration.
(2) Monitoring data of Performance Monitor is obtained. (Monitoring
switch is ON.).
(3) Switching between the master and standby SVPs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Performance Monitor
Changed Part SVP

168 Invalid pair status at restore copy for CoW Snapshot pair
Phenomena When a restore copy was performed for a CoW Snapshot pair, the pair
status did not become Suspend.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A restore copy is requested for a CoW Snapshot pair.
(2) A failure that disables the restore copy is detected.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Copy-on-Write Snapshot
Changed Part DKCMAIN

169 Failure suspension of UR/URz pair with SSB=EF25 output


Phenomena After a failure blockage of MPB occurred, a UR/URz pair with JNLG#
0x00 output SSB=EF25 and was suspended with failure.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator or Universal Replicator for Mainframe
(2) JNLG ownership on UR/URz secondary site belongs to multiple
MPBs.
(3) A failure blockage occurs in an MPB with JNLG ownership on
UR/URz secondary site.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator or Universal Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 67 of 71
170 Frequent output of SSB=50CC at I site
Phenomena When a cache PCB failure blockage occurred at I site in a URxUR
cascade configuration and a failure suspension occurred between I site
and R sites (SSB=EFCB & ECE6), SSB=50CC was output at I site.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open UR/UR cascade configuration
(2) Cache PCB failure blockage occurs at I site.
(3) Suspension occurs between I and R site. (SSB=EFCB and ECE6)
Affected Products/Version DKCMAIN: 30-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN

171 Abend of UVM VOL format with SSBs output


Phenomena LDEV format of a UVM VOL ended abnormally and SSB=8B90,
88F1, AD05, AD11, AD10, 7B0A, and 7B97 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open UVM VOL
(2) An ECC group is of size that is not divisible by 256KB.
(3) Multiple LDEVs are defined in the ECC group.
(4) The end LDEV in the ECC group is formatted.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN

172 No progress of copy processing after ownership migration


Phenomena In 3DC delta configuration, if ownership migration occurred after a
delta resync was performed or a delta pair status changed to HLDE,
copy processing of UR did not make progress.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) JNL that supports UR multi (*)
(2) 3DC multi-target configuration with delta resync (TC and UR),
3DC multi-target configuration with delta resync (UR only), or 3DC
cascade configuration with delta resync
(4) A delta resync operation is performed.
(5) HLDE status of delta UR is changed to HOLD status.
(6) A delta pair status changes to HLDE.
(7) After the operation (6), allocation of the processor blade of LDEV
used by a JNL VOL is changed. (Maintenance, failure, or allocation
from CCI or Storage Navigator)
* A JNLG of JNLG# with (M) on Journal Operation window of
Storage Navigator.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN

HDS Confidential 68 of 71
173 Unable to correct parameters for UR/URz pair creation
Phenomena During UR/URz pair creation for the 2nd mirror UR/URz pair on the
Universal Replicator window of Storage Navigator, an incorrect
parameter was specified.
To correct the parameter, when some pairs displayed in Preview were
selected and then pair creation window was opened again, parameters
such as serial number were fixed and could not be changed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when some pairs displayed on the Preview list are
selected and pair creation window is opened at UR/URz pair creation
for the 2nd mirror UR/URz pair.
The problem does not occur if all of the displayed pairs are selected.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part SVP

174 Incorrect status display of FCSE pair on Storage Navigator


Phenomena The status of an FCSE pair became Faildstate but it was normal on
Storage Navigator.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) FCSE pair configuration
(2) Pair status is Faildstate.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category FlashCopy SE
Changed Part DKCMAIN

175 Failure suspension at delta UR pair deletion with SSB and


SIM output
Phenomena When a delta UR pair was deleted in TCxUR multi-target delta
configuration, URxUR multi-target delta configuration, or URxUR
cascade delta configuration, a failure suspension occurred and
SSB=EC42 and EC01, and SIM=DC1XXX were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TCxUR multi-target delta configuration, URxUR multi-target delta
configuration, or URxUR cascade delta configuration.
(2) A delta UR pair is deleted.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN

HDS Confidential 69 of 71
176 Invalid UR pair status at pair deletion/suspend
Phenomena When a pair deletion was performed for a pair between P site and R
site in UR 3DC (URxUR cascade or URxUR multi-target) delta
configuration, the pair status remained Deleting.
In the case of a pair suspend operation, the pair status remained
Suspending.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator
(2) An old delta configuration of URxUR cascade delta configuration
or URxUR multi-target delta configuration (without UR control path
registration)
(3) UR pair deletion or suspend is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN

177 Failure suspension of unexpected UR pair with SSB=EDD4


Phenomena In UR 3DC (URxUR cascade or URxUR multi-target) delta
configuration, a failure suspension might occur in an unexpected UR
pair and SSB=EDD4 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator
(2) URxUR cascade configuration (I site), URxUR multi-target
configuration (P site), URxUR cascade delta configuration (P site, I
site and R site) or URxUR multi-target delta configuration (P site, L
site, and R site)

* The problem occurs only when sending message for job activation
fails (internal condition), and therefore the probability is low.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN

HDS Confidential 70 of 71
178 Failures of relationship status display on Storage Navigator
Phenomena Phenomenon1
When an FCv2 relationship was created while sharing the source VOL
(S-VOL) with an already-created FCSE relationship, the S-VOL of
FCv2 did not become Normal status on Storage Navigator.
Phenomenon2
When an FCSE relationship was created while sharing S-VOL with an
already-created FCv2 relationship, the S-VOL of FCSE did not
become Normal status on Storage Navigator.
Phenomenon3
When an FCv2 relationship was deleted while FCSE and FCv2 shared
S-VOL, the S-VOL of FCv2 remained in Normal status on Storage
Navigator.
Phenomenon4
When an FCSE relationship was deleted while FCSE and FCv2 shared
S-VOL, the S-VOL of FCSE remained in Normal status on Storage
Navigator.
Phenomenon5
When FCSE and FCv2 shared S-VOL and both relationships were in
Suspend status, if the relationship in Suspend status was deleted, the
status remained SUS on Storage Navigator.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
Phenomenon1
(1) FCSE relationship configuration
(2) An FCv2 relationship is created by using S-VOL of the FCSE
relationship.
Phenomenon2
(1) FCv2 relationship configuration
(2) An FCSE relationship is created by using S-VOL of the FCv2
relationship.
Phenomenon3
(1) FCSE and FCv2 relationships share the same S-VOL.
(2) The FCv2 relationship is deleted.
Phenomenon4
(1) FCSE and FCv2 relationships share the same S-VOL.
(2) The FCSE relationship is deleted.
Phenomenon5
(1) FCSE and FCv2 relationships share the same S-VOL and the both
relationships are in Suspend status.
(2) Other than the above, there is another FCSE/FCv2 relationship that
uses the same S-VOL and the relationship is not in Suspend status.
(3) The FCSE/FCv2 relationship in suspend status is deleted.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category FlashCopy version2, FlashCopy SE
Changed Part DKCMAIN

HDS Confidential 71 of 71