A key management server that supports Key Management Interoperability Protocol (KMIP),
which is in particular;
SafeNet KeySecure K460 (Software version: 6.1.0)
Changed Part Storage Navigator
For details, see CCI Command Reference Guide or manuals for each PP.
Changed Part DKCMAIN
HDS Confidential 1 of 71
1-5 Improvements to ease restrictions on maintenance
Description Improvements to ease restrictions on maintenance are implemented. In particular, the
following operations are allowed.
1- LDEV format for RAID groups other than those in copy processing during Dynamic
Sparing, Correction Copy, and Copy Back
2- Replacement of PDEVs other than ones in LDEV format processing during LDEV format
3- Online micro-program exchanges of other than DKU and SCHIP during Dynamic
Sparing, Correction Copy, and Copy Back.
4- Installation/removal of CHA, DKA, cache, MPB, and RAID group while data has been
backed up in a spare drive. However, a RAID group and spare drive which are in backup
process cannot be removed (current specification).
5- Installation/removal of external volumes and virtual volumes from Storage Navigator
while a PDEV is blocked.
Changed Part DKCMAIN, SVP
1-7 Support for rebalance of usage rate among parity groups with pool volumes
Description New System Option Mode 917 is available to average the usage rate among parity groups
with pool volumes defined to reduce drive load of the parity groups.
- Mode 917 = ON (default):
Usage rate is averaged among parity groups where pool volumes are defined.
- Mode 917 = OFF:
Usage rate is averaged among pool volumes without considering parity groups.
Public Mode – No Permission Required to Use
Changed Part DKCMAIN
HDS Confidential 2 of 71
1-9 Support for delta resync when TC/ UR and TCz /URz in same CTG
Description The Delta resync function is supported when TC/UR and TCz/URz pairs are in the same
CTG.
Changed Part DKCMAIN
New System Option Mode 909 is available to disable the UR/URz restore processing
improvement.
1-14 Support for SOM786 to report pair status of TC/TCz RCU side
Description System Option Mode 786 is available to report to MCU the pair status on TC/TCz RCU side
even when there is no RIO and the pair status on RCU changes after the remote copy path
between MCU and RCU is disconnected and then recovered.
HDS Confidential 3 of 71
1-16 SVP security enhancement
Description The following security enhancements are done for SVP.
- Unnecessary TCP ports of SVP are blocked.
- SSL certificates of RMI can be replaced. (For procedures to replace the certificates, see the
Storage Navigator User Guide.)
- Components of SSL Ciphersuite that contain vulnerability are excluded.
Changed Part SVP
1-17 Support for SOM600 and 601 to change UR initial copy pace
Description New System Option Modes 600 and 601 are available to change the UR initial copy pace
(MIDDLE mode) from125MB/s to 250MB/s or 500MB/s as follows.
When SOM600 is set to ON: 250MB/s
When SOM601 is set to ON: 500MB/s
- Restricted Mode – RSD Permission Required to Use
Changed Part DKCMAIN
2. Mainframe System
2-2 Support for z/OS FICON Discovery and Auto Configuration for System z
Description Z/OS FICON Discovery and Auto Configuration for System z function (zDAC) in
Mainframe (IBM host) environment are supported. The zDAC is a function to do the
following operations automatically.
-To detect new or updated devices
-To create configuration definition of I/O devices
This function enables to automate and simplify operations that rely on users, such as
reduction of the time required to set up new I/O devices, mitigation of requirements for
expertise skill, and keeping consistency of the entire system and storage system definitions,
so that management cost of users can be reduced drastically. This function is a z/OS
function. For the information of system environment, operating procedures, and notes, see
documents provided by IBM such as Readbook.
Changed Part DKCMAIN, HTP
HDS Confidential 4 of 71
2-4 Support for 3DC multi target and cascade of URz
Description In Mainframe environment, 3 data center (3DC) multi target and cascade configurations
using Universal Replicator for Mainframe only are supported.
-Multi target: A function to back up the data in a P-VOL (primary site) to 2 S-VOLs
(secondary site).
-Cascade: A function to back up the data in a P-VOL to an S-VOL (intermediate site), and
then back up the data in the S-VOL to another S-VOL (secondary site).
Changed Part DKCMAIN
3. OPEN System
3-1 Support for per-page allocation policy setting
Description Per-page policy setting is supported.
Tier allocation policy (Level1 only) can be set per page.
Per-page setting is prioritized over per-virtual VOL setting.
Frequency distribution information per lane of DT can be obtained from RAID Manager
Lib. The setting and reference are only available on Hi-Command.
Changed Part DKCMAIN
HDS Confidential 5 of 71
3-3 Support for HMO68
Description New Host Mode Option 68 is available to enable Linux to issue Write Same (16) command
so that pages that the host has used are released.
-Mode 68 = ON:
The Version field of Standard Inquiry is set to 05h.
LBPRZ and LBPME bit of Read Capacity (16) are set.
Block Limits VPD Page and Logical Block Provisioning VPD Page are supported.
-Mode 68 = OFF (default):
The Version field of Standard Inquiry is set to 02h.
LBPRZ and LBPME bit of Read Capacity (16) are not supported.
Block Limits VPD Page and Logical Block Provisioning VPD Page are not supported.
-Public Mode – No Permission Required to Use
Changed Part DKCMAIN
3-4 Support for Flash Acceleration for Simplex VOL and DP-VOL
Description The performance is improved at cache miss for Simplex VOL and DP-VOL in OPEN
environment by reducing micro-program processing. The PP license of Flash Acceleration
must be installed to enable this function.
Changed Part DKCMAIN
HDS Confidential 6 of 71
The change of contents for Version 70-04-01-00/00-M114
1 Failure suspension at Flush suspend for all UR pairs in
JNLG
Phenomena When a suspend operation was performed for all UR/URz pairs (8192
pairs) in a JNLG with LU specified, SSB=EDBF and SIM=DC0XXX
were output and the operation turned to a failure suspension.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator or Universal Replicator for Mainframe
(2) System Option Mode 449 is set to OFF.
(3) There are 2000 or more pairs in a JNLG.
(4) Flush suspend is performed for all the above pairs with LU
specified.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator or Universal Replicator for Mainframe
Changed Part DKCMAIN
HDS Confidential 7 of 71
3 Display of invalid dashed line in graph
Phenomena When "Maximum value display" or "Minimum value display" was
selected for [Display Option] on SVP and a graph for "Bad Received
Character Count. (Fibre)" was displayed, an invalid dashed line was
displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) "Port" is selected for Object in [Monitor Data Choice].
(2) "Loss Of Signal Count.(Fibre)", "Bad Received Character
Count.(Fibre)", "Loss Of Synchronization Count.(Fibre)", "Link
Failure Count.(Fibre)", "Received EOFs Count.(Fibre)", "Discarded
Frame Count.(Fibre)", "Bad CRC Count.(Fibre)", "Protocol Error
Count.(Fibre)", "Invalid Frame Count.", or "HTP/FNP Ex
Multiple.[Ex/sec.](FICON)" is selected for Item of [Monitor Data
Choice]. (Those are collectively called unsupported item.)
(3) "1 [min]" or "1 [hour]" is selected for [Sampling Rate(Display
Period)]
(4) "Maximum value display" or "Minimum value display" is checked
for [Display Option].
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
Operation (B)
(1) A CMF PCB is removed.
(2) At the location where the above CMF PCB removal is performed, a
DKA is installed.
Causes and Updates The micro-program has been modified not to output SSBs at DKA
installation.
Affected Products/Version DKCMAIN: All
SVP: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
SVP: 70-04-01/00
Category Open or Mainframe
Changed Part DKCMAIN, SVP
HDS Confidential 8 of 71
5 Failure of multiple SSBs output
Phenomena Even though multiple SSBs were supposed to be output, only one SSB
was output. (The problem occurred with SSBs created by SVP.)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when multiple SSBs are created by SVP in a
second.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 9 of 71
8 Unintentional change of Tier Management mode
Phenomena For DT where Tier Management mode was Auto, when tier capacity
ratio for new allocation was changed from CCI (raidcom modify pool
-pool <pool ID#> -tier <Tier number> <ratio>), the Tier Management
mode changed to Manual.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) DT where Tier Management mode is Auto.
(2) One of the following operations is performed from CCI.
(a) Change of tier capacity ratio for new allocation (raidcom modify
pool -pool <pool ID#> -tier <Tier number> <ratio>)
(b) Change of buffer rate of tier for relocation (raidcom modify pool -
pool <pool ID#> -tier <Tier number> -tier_buffer_rate <%>)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN
HDS Confidential 10 of 71
10 Invalid display of capacity unit
Phenomena Phenomenon 1:
Even though resources in a table list on the following windows were
for Open only, "cylinder" that was a display unit for Mainframe was
available in Options for display unit.
Phenomenon 2:
For a table list on the following windows, "Cylinder" and "Page"
which were display units for Mainframe and pool VOLs respectively
were displayed in a unit of GB.
Edit Pools, Restore Pools, Shrink Pool, Stop Shrinking Pool, Monitor
Pools, Stop Monitoring Pools, Start Tier Relocation, Stop Tier
Relocation, Create Pools, Delete Pools, Pool Property
Phenomenon 3:
For a table list on the following window, "Cylinder" which was a
display unit for Mainframe was displayed in a unit of GB.
Expand Pool
Severity (High, Medium, Low) Low
Conditions of Occurrence Phenomenon 1:
The problem occurs when at least one Mainframe parity group or
LDEV exists in the configuration.
Phenomenon 2:
The problem occurs when the target window is displayed while pools
are displayed in a unit of cylinder or page on the previous window.
Phenomenon 3:
The problem occurs when the target window is opened while pools are
displayed in a unit of cylinder on the previous window.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part Storage Navigator
HDS Confidential 11 of 71
11 Incorrect sort order of resources
Phenomena On the following windows, setting target resources were not sorted in
ascending order.
Create Pools, Add External Volumes, Add to Host Groups, Add Hosts,
Delete LUN Paths, Delete Pools, Expand Pool, Edit Pools, Edit
External WWNs, Edit Command Devices, Edit CU Monitor Mode,
Edit WWN Monitor Mode, Add New Monitoring WWNs, Delete
External Volumes, Disconnect External Paths, Reconnect External
Paths, Add to Ports, Add Resources, Disconnect External Volumes,
Delete Host Groups, Delete Reports, Restore Pools, Shrink Pool
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when resources are not added in ascending order
during a user operation on any of windows above.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part Storage Navigator
HDS Confidential 12 of 71
14 Inconsistent version number between basic information and
manual
Phenomena For the downloaded audit log information files, the version number in
basic information was different from that described in manual.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when SVP micro-program of version 70-03-01/00
or higher is installed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-03-01/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 13 of 71
17 ABEND of micro-program exchange when MP overload is
detected
Phenomena When micro-program exchange was started from FC WIZARD, if MP
overload was detected and the micro-program exchange was stopped, a
message (SVP Internal Error) was displayed on FC WIZARD window
and the operation ended abnormally.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Micro-program exchange is performed from FC WIZARD.
(2) MP load is 50% or higher.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 14 of 71
20 No response of Storage Navigator window
Phenomena Storage Navigator window became white and no response was
returned.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Flash Player does not respond at all when
Storage Navigator is being activated.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 15 of 71
23 Failure of license installation
Phenomena When a DT license key was installed, an error occurred (Storage
Navigator message 405-8204) and license status became [Installed
(Disable)].
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SM Function Install is performed on CL2.
(2) SVP reboot occurs during a period from when SVP message
ONL2370I appears and then [YES] is clicked until when INLINE
CUDG is completed.
(3) PS OFF and non-volatile PS ON are performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 16 of 71
26 No display of Attribute column in Parity Group table on
Resource Group Properties window
Phenomena The Attribute column was not displayed in Parity Groups table on
Resource Group Properties window.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Resource Group Properties window is
displayed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-03-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP
HDS Confidential 17 of 71
29 WCHK1 after LDEV installation when different versions
micro-program are used
Phenomena When an LDEV was installed while different versions of micro-
program were used, WCHK1 occurred after the installation was
completed. (SSB=32FE and SIM=3073XX)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Different versions of micro-program; V03 and higher and earlier
than V03, are used in a storage system.
(2) LDEV installation or removal is performed.
Causes and Updates The micro-program has been modified so that the LDEV installation or
removal will end abnormally in this case.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 18 of 71
32 ATS command time-out with SSBs output
Phenomena When an ATS command and an UNMAP command were executed for
the same page at the same time while SOM905 was set to ON, the ATS
command turned time-out and SSB=D034 which meant command
time-out and SSB=14DC which meant time-out to wait for internal
resource were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) SOM905 is set to ON.
(2) A DP-VOL is in Simplex status.
(3) An ATS command is issued to the DP-VOL.
(4) An UNMAP command is issued to a range that contains the target
page of the ATS command.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN
HDS Confidential 19 of 71
35 No data check error occurs for write I/O of invalid data for
Database Validator
Phenomena When volatile activation was performed after PS OFF while Database
Validator was set, a data check error did not occur for a write I/O of
invalid data for the Database Validator even though there was setting
information of Database Validator on CCI.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Database Validator is set to LDEV# 0x8000 to 0xfeff.
(2) One of the following operations is performed.
(a) PS OFF
(b) DKCMAIN configuration change
(3) One of the following operations is performed.
(a) Offline micro-program exchange
(b) Volatile activation
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN
HDS Confidential 20 of 71
37 Frequent link-down in host path with SSB=B60D output
Phenomena When a UVM path was blocked and then a UVM VOL was blocked,
link-down frequently occurred in a host path and SSB=B60D was
output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a large number of ABTSs from a host occur
due to disconnection of external path or volume blockage.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN
HDS Confidential 21 of 71
41 Failure of increase of the number of IU Pacings by Extended
Distance FICON
Phenomena Phenomenon1
During I/O processing with the micro-program of V03+1 while the
number of IU Pacings was increased to 64 by Extended Distance
FICON function, the number of IU Pacings decreased to 16.
Phenomenon2
When the micro-program was exchanged from earlier than V03+1 to
V03+1, the number of IU Pacings expanded by Extended Distance
FICON function was not increased to 64 but remained 16.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) There is a CMF PCB in the storage system.
(2) FNP attribute is set to the CMF PCB.
(3) One of the following operations is performed.
(a) Online micro-program exchange within V03+1 range or from
earlier than V03+1 to V03+1.
(b) MPB installation (Micro-program version is V03+1)
(c) MPB replacement (Micro-program version is V03+11)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN
HDS Confidential 22 of 71
43 Failure suspension of TCz/URz pair
Phenomena Phenomenon1
CMF PCB removal on RCU of TCz or URz was not guarded, and all
of CMF PCBs became blocked or unmounted, which might result in
failure suspension.
Phenomenon2
While all of CMF PCBs were blocked or not mounted, pair creation
was not guarded but enabled, which might result in failure suspension.
In both cases, SIM= D46X (TCz) and DC0X (URz), and SSB=ED6A
were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TrueCopy for Mainframe or Universal Replicator for Mainframe
(2) All CMF PCBs are blocked or removed.
(3) There is one of the following volumes in DKC.
(a) TCz S-VOL whose emulation type is 3390-A. (Common to DP and
non-DP)
(b) URz S-VOL.
(4) The pair status is not Suspend. (Mirror status is not Stop)
Causes and Updates The micro-program has been modified to fix the problem.
In the case of phenomenon 1, SVP message SVP4341E will be output.
In the case of phenomenon 2, Storage Navigator message 6005-78066
will be output.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy for Mainframe, Universal Replicator for Mainframe
Changed Part DKCMAIN
HDS Confidential 23 of 71
45 Unable to accept host I/O after recovery from system
configuration failure due to wrong cable connection
Phenomena When a system configuration failure due to incorrect cable connection
was recovered, an I/O from a host might not be accepted even though
SVP window showed that LDEV status was normal. SSB=D054 was
output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) PS ON is performed with a wrong cable connection between SSWs.
(2) The wrong connection is corrected and the system is recovered by
SSW or DKA replacement.
(3) After the above, a host I/O is issued without performing PS OFF
and ON.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 24 of 71
47 Failure of PDEV/SSW/DKA replacement
Phenomena If a type name of spare drive was displayed as "????????" on Refer
Configuration window, replacement of PDEV of the spare drive or that
of SSW/DKA to which the spare drive belonged failed and SSB=A7E1
was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) An SSD drive is used as a spare drive.
(2) Drive copy to the spare drive is executed.
(3) PS OFF and ON is performed while the spare drive is used as a
copy target of data drive.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 25 of 71
50 Temporary high MP usage rate
Phenomena Immediately after background copy started, the MP usage rate
temporarily went over 80% and I/O response degraded.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when the following condition is met.
(1) Background copy for multiple FC pairs is executed at the same
time. (Executing Withdraw while DDSW=YES is specified, or
Establish is executed in copy mode)
(The problem is more likely to occur if the volume size or the number
of FC pairs is large.)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category FlashCopy version2
Changed Part DKCMAIN
HDS Confidential 26 of 71
53 SSB=1479 output by CM failure blockage during CM
recovery processing
Phenomena During CM recovery processing, if CM failure blockage occurred on
the side being recovered, SSB=1479 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) CM recovery processing is executed.
(2) CM failure blockage occurs on the side being recovered.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 27 of 71
56 No display of some items on Detail dialog box
Phenomena When an SI, SIz, or Snapshot pair was selected and Detail dialog box
was opened on Storage Navigator sub-window, items that were
displayed on Pair Operation window such as copy pace and Svol mode
(SI)/Tvol mode (SIz) were not displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an SI, SIz, or Snapshot pair is selected and
Detail dialog box is opened on Storage Navigator sub-window.
Causes and Updates The micro-program has been modified to fix the problem.
ShadowImage: Copy pace and Svol mode are added to display on
Detail dialog box.
ShadowImage for Mainframe: Copy pace, Tvol mode, Relationship are
added to display on Detail dialog box.
Snapshot: Svol mode is added to display on Detail dialog box.
Affected Products/Version SVP: 70-03-33/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category ShadowImage, ShadowImage for Mainframe, Copy-on-Write Snapshot
Changed Part SVP
HDS Confidential 28 of 71
59 Invalid display of device encryption status
Phenomena Even though encryption was enabled for a device, when DEVSERV
QDASD command was executed from a Mainframe host,
ENCRYPTION (YES/NO) = "N" was displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe connection
(2) Encryption is enabled for a device.
(3) DEVSERV QDASD command is executed from the Mainframe
host to the device.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN
HDS Confidential 29 of 71
62 Display failure when Multi-Tier Pool setting changed to
Enable
Phenomena Phenomenon1
When a DP pool was selected and Multi-Tier Pool setting was
switched to Enable on Edit Pools window of Storage Navigator, Buffer
Space for New page assignment and Buffer Space for Tier relocation
were displayed in blank.
Phenomenon2
When a DP pool and a DT pool were selected and Multi-Tier Pool
setting was switched to Enable on Edit Pools window of Storage
Navigator, Cycle Time, Monitoring Period, Monitoring Mode, Buffer
Space for New page assignment, and Buffer Space for Tier relocation
were displayed in blank.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following operations were performed on
Edit Pools window of Storage Navigator.
Phanomenon1
A DP pool is selected and Multi-Tier Pool setting is switched to
Enable.
Phenomenon2
A DP pool and a DT pool are selected and Multi-Tier Pool setting is
changed to Enable.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-53/00 and higher (DP, DPz and DT), 70-03-01/00 and
higher (DTz)
Fixed Product/Version SVP: 70-04-01/00
Category Dynamic Provisioning, Dynamic Provisioning for Mainframe,
Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part SVP
HDS Confidential 30 of 71
64 Failure of Detail button
Phenomena When a task of Stop Shrinking in Failed status was selected on Tasks
window of Storage Navigator and then task status was displayed,
"Detail" button did not work.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a task of Stop Shrinking in Failed status is
selected, task status is displayed, and then Detail button is clicked.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP for Open: All
SVP for Mainframe: 70-02-53/00 and higher (DPz), 70-03-01/00 and
higher (DTz)
Fixed Product/Version SVP: 70-04-01/00
Category Dynamic Provisioning, Dynamic Provisioning for Mainframe,
Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part SVP
HDS Confidential 31 of 71
67 Indirect (two-step) page relocation from tier3 to tier1
Phenomena During page migration from tier3 to tier1 in tier relocation processing,
pages might be migrated from tier3 to tier2 and then tier2 to tier1
(taking 2 steps) in some cases.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) 3-tier configuration
(2) A DP-VOL whose tier policy setting is level2.
(3) Pages in tier3 are relocated to tier1.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN
HDS Confidential 32 of 71
70 SSB=5321/5322 output at CMF PCB installation
Phenomena When a CMF PCB was installed, SSB=5321 and 5322 were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when a CMF PCB is installed on a system
where no CMF PCB is installed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN
72 Write PIN slot occurrence when SSW of the 2nd DKU BOX
is removed
Phenomena When SSW of the 2nd DKU-BOX was removed while SOM797 was
set to ON, a write PIN slot occurred and SIM=EF4X-XX
(XX=LDEV#) and SSB=1B10, 1B60, and A4C2 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SOM797 is set to ON.
(2) An SSW failure occurs in one of DKU boxes from the 2nd to the
last.
(3) I/O overload.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN
HDS Confidential 33 of 71
73 Frequent SIM output when SSW is removed during I/O
processing
Phenomena When an SSW was removed during I/O processing, SIM=DF7X-YY
(X-YY=C/R#) indicating a drive port temporary failure was output 26
times.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) An SSW failure occurs in DKU boxes from the 2nd to the last.
(2) I/O overload.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category HDD
Changed Part DKCMAIN
HDS Confidential 34 of 71
76 SSD model name erased after replacement
Phenomena While an SSD without model name was mounted on a CPK, when
another SSD in the same CPK was replaced and then the CPK was
replaced, the model name of latter SSD was erased.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The CMBK version is earlier than 70-72-55
(2) An SSD in a CPK that contains another SSD without model name
is mounted is replaced.
(3) The SSD or CPK is replaced.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 35 of 71
79 SSB=5AD2 output at recovery of pool associated with TSE-
VOL
Phenomena After operations from pool initialization through pool recovery were
performed in accordance with the procedures of WEB03-170 and
TRBL20-100, and a TSE-VOL became normal condition, when
VOLSER was set, SSB=5AD2 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when a pool with which a TSE-VOL is associated
is recovered.
Affected Products/Version DKCMAIN: 70-02-70-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Flash Copy SE
Changed Part DKCMAIN
HDS Confidential 36 of 71
82 Failure of Create LDEVs with Storage Navigator error 3305-
001035
Phenomena When Create LDEVs was performed from Storage Navigator, the
processing failed and Storage Navigator error 3305-001035 occurred.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Delete LDEVs is performed to delete all LDEVs in a CU#.
(2) Before the completion of the above task, Create LDEVs including
the same CU# is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP
HDS Confidential 37 of 71
85 Incorrect message display when invalid value is entered for
WWN name
Phenomena When an invalid value was entered in a text field for WWN name on
Add New Monitored WWNs window or Edit WWN window and then
a user focused out (selected another item), the following Storage
Navigator message was displayed.
"The form of Host Group Name is wrong. Please input the
alphanumeric character and the
sign (except \ / : , ; * ? " < > |) within 64 characters."
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an invalid value is entered in a text field for
WWN name on Add New Monitored WWNs window or Edit WWN
window and then a user focuses out. (Select another item)
Causes and Updates The micro-program has been modified to fix the problem.
The message is corrected as follows.
"The form of WWN name is wrong. Please input the alphanumeric
character and the
sign (except \ / : , ; * ? " < > |) within 64 characters."
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP
[FCSE]
(1) Mainframe
(2) FCSE pair is created.
(3) Target VOL (T-VOL) pool is full.
(4) A read command is issued to the T-VOL.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-70-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN
HDS Confidential 38 of 71
87 No output of SSB=B6BE and no change of time-out value
even when HMO67 is ON
Phenomena Even though HMO67 was set from OFF to ON, SSB=B6BE was not
output and the E_D_TOV value was not changed from 2sec to 20sec.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) HMO67 setting is changed for other than host group#0.
(2) A port whose HMO67 setting is changed is Target or RCU_Target.
(3) Fabric of a port whose HMO67 setting is changed is OFF.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-80-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN
88 SSB=E703 output
Phenomena SSB=E703 might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when one of the following operations is
performed during relocation or a processing to fix monitoring data.
(1) Pool shrink
(2) Pool expansion (only cases that the number of tiers increases.)
(3) Setting change of multiple tier pools from ON to OFF
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN for Open: All
DKCMAIN for Mainframe: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN
HDS Confidential 39 of 71
90 Audit log information file initialization at SVP activation
Phenomena At SVP activation, SSB=3359 was output and an audit log information
file was initialized.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a conflict of accesses to an audit log
information file occurs at SVP activation.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 40 of 71
94 Inconsistency between item and content
Phenomena On "Threshold Counter Display" dialog box of Information, items and
their contents did not match as follows.
(1) For "Mechanical error (unrecovered)", error count and threshold of
"SAS I/F error Port 0" were displayed.
(2) For "Media error (unrecovered)", error count and threshold of
"Mechanical error (unrecovered)" were displayed.
(3) For "Read/Write error (unrecovered)", error count and threshold of
"Media error (unrecovered)" were displayed.
(4) For "Drive I/F error (unrecovered)", error count and threshold of
"Read/Write error (unrecovered)" were displayed.
(5) For "Controller hardware error (unrecovered)", error count and
threshold of "Drive I/F error (unrecovered)" were displayed.
(6) For "SAS I/F error Port 0", error count and threshold of "Controller
hardware error (unrecovered)" were displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when communication to DKC executed when
displaying Threshold Counter Display dialog of Information fails.
(When the communication fails, "Unknown" is displayed for the
"Today" error count and threshold)
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-03-33/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 41 of 71
96 TPF host message CYED0061W output when MPLF
function is used
Phenomena While MPLF function of TPF was used, TPF host message
CYED0061W might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TPF host connection
(2) MPLF function is used.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-36-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Mainframe
Changed Part DKCMAIN
HDS Confidential 42 of 71
99 Incompletion of CLPR setting
Phenomena CLPR setting (capacity change) did not finish. (A dialog box of
Loading …..remained displayed.)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) There is a blocked MPB.
(2) CLPR capacity is changed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 43 of 71
102 Registered task disappears
Phenomena On Tasks window of Storage Navigator, a registered task disappeared.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) One of tasks listed below, which is being executed or in wait status,
is registered.
(2) SVP is rebooted.
- Format
- Shredding
- Edit encryption to request format operations
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open Volume Management, Virtual LVI
Changed Part SVP
103 Incorrect display for source VOL and target VOL when
FCv2/FCSE pairs exist
Phenomena In [CopyType-FCv2] and [CopyType-FCSE] columns on Replica
LDEVs window, and in [Compatible FlashCopy(R) V2] and
[Compatible Software for IBM(R) FlashCopy(R) SE] on LDEV
Properties window, "S" for source VOL (S-VOL) and "T" for target
VOL (T-VOL) such as "S-Normal", "T-Normal", and "ST-Normal"
were displayed as "P" and "S" respectively like "P-Normal", "S-
Normal", and "PS-Normal".
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when there is any FCv2 pair or FCSE pair.
Affected Products/Version SVP: 70-03-33/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Storage Navigator
Changed Part SVP
HDS Confidential 44 of 71
105 SSB=137E output and decrease in available cache capacity
Phenomena SSB=137E was output and available cache capacity might decrease.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Ownership migration is performed manually.
(2) Offline micro-program or volatile PS ON is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 45 of 71
108 SSB=5600 output during I/O processing
Phenomena During I/O processing, SSB=5600 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe connection
(2) Compatible PAV is installed.
(3) An alias is added.
(4) An I/O is in process.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 46 of 71
111 Session interrupted after SN message 20121-107025 output
Phenomena When a user logged into Storage Navigator and performed any window
operation, Storage Navigator message 20121-107025 was displayed
and a session was interrupted.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs in rare cases when any window operation of
Storage Navigator is performed.
Affected Products/Version SVP: 70-03-01/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 47 of 71
114 Link-down due to hardware failure during HMO51 setting
operation
Phenomena At HMO51 setting operation, if a hardware failure occurred (MPB,
CHT PCB failure, MP failure (CHK1B)), an access to internal
resources was disabled and link-down occurred. (SSB=B6FB)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) TC/TCz configuration.
(2) HMO51 is set to ON or OFF in RCU Target port.
(3) During the above setting operation, a failure occurs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-31-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy, TrueCopy for Mainframe
Changed Part DKCMAIN
HDS Confidential 48 of 71
117 Failure of cache DIMM removal
Phenomena Cache DIMM removal failed with SVP message ONL2788E output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The message occurs when all the following conditions are met.
(1) DKC 1-module configuration.
(2) PS ON is performed while MPB is mounted on an added DKC
(operation mistake).
(3) Maintenance related to basic CM PCB is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open and Mainframe
Changed Part DKCMAIN
HDS Confidential 49 of 71
120 No guard for incorrect operation on the window
Phenomena At CM installation/removal, if CM capacity, Cache Residency Manage
(DCR) capacity, or the number of extents of CLPR1 to 31 was changed
without changing CM capacity, the operation was not guarded on the
window. After that, SVP message ONL0870I was output during the
later processing and the operation was disabled without operation
target.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) CM installation or removal is performed.
(2) One of the following operations is performed.
(a) At CM removal, CM capacity, Cache Residency Manage (DCR)
capacity, or the number of extents of CLPR1 to 31 is reduced without
reducing the CM capacity.
(b) At CM installation, CM capacity, DCR capacity, or the number of
extents of CLPR1 to 31 is increased after CM capacity is increased,
and then the CM capacity is turned back to the previous.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 50 of 71
122 Blockage of MP at offline micro-program exchange or SM
volatile power ON
Phenomena Phenomenon1
During offline micro-program exchange of DKCMAIN, WCHK1
occurred, some MPs were blocked, and the exchange failed. (SVP
message SMT2433E and SSB=0005/0006 were output.)
Phenomenon2
When SM volatile power ON was performed, the system was activated
with some MPs blocked. (SSB=0005/0006 was output.)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The total capacity of DP/DPz/DT/DTz pools is 3.5PB or larger.
(2) Offline micro-program exchange or SM volatile power ON is
performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Provisioning, Dynamic Provisioning for Mainframe,
Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN
HDS Confidential 51 of 71
124 Page allocation to inadequate tier
Phenomena Even when the total capacity of tiering policy level1 could be
contained in Tier1, pages were allocated in Tier2 in some cases.
Even when the total capacity of tiering policy level3 could be
contained in Tier2, pages were allocated in Tier3 in some cases.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when any of the following conditions is met.
[When the number of tiers is 3]
(1) There are settings for Tiering Policy Level1, and Level2 or ALL in
a pool, and the following formula works:
The total capacity of level1 < tier1 capacity x depletion threshold < the
total capacity of level1 + the total capacity of level2 or ALL
(2) There are settings for Tiering Policy Level3, and Level4 or ALL in
a pool, and the following formula works:
The total capacity of level3 < tier2 capacity x depletion threshold < the
total capacity of level3 + the total capacity of level4 or ALL
(3) There are settings for Tiering Policy Level2 (which can be included
in Tier1) and ALL in a pool, and the following formula works:
The total capacity of Level2 < tier1 capacity × depletion threshold <
the total capacity of Level1 + the total capacity of ALL
(4) There are settings for Tiering Policy Level4 (which can be included
in Tier2) and ALL in a pool, and the following formula works:
The total capacity of Level4 < tier2 capacity x depletion threshold <
the total capacity of Level3 + the total capacity of ALL
[When the number of tiers is 2]
(5) There are settings for Tiering Policy Level1 and ALL in a pool,
and the following formula works:
The total capacity of level1 < tier1 capacity x depletion threshold < the
total capacity of level1 + the total capacity of ALL
Affected Products/Version DKCMAIN for Open: 70-02-54-00/00 and higher
DKCMAIN for Mainframe: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Tiering, Dynamic Tiering for Mainframe
Changed Part DKCMAIN
HDS Confidential 52 of 71
126 Failure of dump collection
Phenomena At dump collection, an SVP message "Dump of the following
processors could not be done." appeared and the collection was
disabled.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the operation (2) is performed without
replacing the blocked CHA/DKA after the operation (1).
(1) Volatile activation while CHA/DKA are not inserted.
(2) Non-volatile power outage or non-volatile PS OFF and then power
ON while inserting the above CHA/DKA
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 53 of 71
129 Wrong Reservation Conflict response
Phenomena In Non Disruptive Migration (NDM) configuration, Reservation
Conflict wrongly occurred for a TestUnitReady, StartStopUnit, or
XCOPY command, and SSB=D5A8 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) NDM configuration
(2) An environment where Reserve is used. (Both of SCSI-2 Reserve
and Persistent Reserve)
(3) One of the following operations is performed.
(a) A TestUnitReady command is issued while Host Mode Option2 is
set to ON.
(b) A StartStopUnit command is issued while Start bit is ON.
(c) An XCOPY command is issued while Host Mode Option62 is set
to OFF.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN
HDS Confidential 54 of 71
132 Failure of filtering Total or Used capacity by cylinder
Phenomena On V-VOL tab on the top window displayed when an individual pool
was selected from Pool on Storage Navigator, when Capacity Total or
Used column was filtered by cylinder for capacity unit, it was not
filtered by cylinder.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs all the following conditions are met.
(1) A pool of Mainframe is displayed on V-VOL tab on the top
window displayed when a pool is selected from Pool on Storage
Navigator.
(2) Capacity Total or Used is filtered with cylinder specified for
capacity unit.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-53/00 and higher (DPz), 70-03-01/00 and higher (DTz)
Fixed Product/Version SVP: 70-04-01/00
Category Dynamic Provisioning for Mainframe, Dynamic Tiering for Mainframe
Changed Part SVP
HDS Confidential 55 of 71
135 Devices unrecognized from host after Shut/No shut is
performed
Phenomena After Shut/No shut (to enable or disable port) was performed on a
switch port, login to a host failed and devices could not be recognized.
(SSB=BC29)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when Shut/No shut is performed on a switch port
connected with a CHG PCB (FCoE port).
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Open
Changed Part DKCMAIN
HDS Confidential 56 of 71
138 Unsupported platform contained in Readme file and
directory for Export Tool
Phenomena Unsupported platforms were mentioned in Readme file for
Performance Monitor Export Tool. A folder of HP-UX that was not
supported existed in the directory of PP media.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Export Tool of Performance Monitor is used
on Unix.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Performance Manager
Changed Part SVP
HDS Confidential 57 of 71
141 Performance degradation of TC/TCz, UR/URz, LDEV
Phenomena When TC/TCz or UR/URz was used or LDEV format was performed,
if an MP failure such as CHK3 repeatedly occurred in the same MP,
performance of I/O processing, TC/TCz, UR/URz, and LDEV format
might degrade and SSB=1042 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TC/TCz or UR/URz is used or LDEV format is performed.
(2) A failure reset (such as CHK3, CHK1B, CHK4 and hang-up reset)
occurs in an MP in an MPB having ownership of the LDEV used in
(1).
(3) The above failure reset repeatedly occurs in the same MP.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category TrueCopy, TrueCopy for Mainframe, Universal Replicator, Universal
Replicator for Mainframe
Changed Part DKCMAIN
HDS Confidential 58 of 71
144 SSB=14DC and 14FF output when external VOL is used
Phenomena When an external VOL was used, SSB=14DC and 14FF (waiting
timeout for resource) were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Volume Manager is used.
(2) Cache mode is ON in an external VOL.
(3) System Option Mode872 is set to ON.
(4) Sequential write I/O and random write/read I/O are issued to the
same VOL.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-01-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Volume Manager
Changed Part DKCMAIN
HDS Confidential 59 of 71
147 Invalid display of HDEV (DP) on result window when Verify
error occurs
Phenomena When a Verify error occurred in "Verify" processing for a pool VOL,
if the result window was displayed, an item of HDEV (DP) was
displayed by hyphen. It was also displayed by hyphen for a text file
output by Archive function.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Verify function is executed on Maintenance window.
(2) The above operation is performed for a pool VOL of Open
emulation to which DP-VOL is allocated.
(3) A Verify error occurs in the above pool VOL.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 60 of 71
150 Failure of CCI activation from remote command device
Phenomena When CCI was activated using a remote command device,
SSB=D07B/B98E or D07B/B98F were output and the activation
failed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Instance of CCI connected to a remote command device is
activated.
(2) Multiple CCI instance numbers or multiple server connection
WWNs are used.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category CCI
Changed Part DKCMAIN
HDS Confidential 61 of 71
153 Inadequate Storage Navigator message
Phenomena At a pair addition from Storage Navigator, if a serial number different
from that corresponding to a registered mirror# was registered, Storage
Navigator message 6505 58040 (An internal error occurred.) appeared,
but the error could not be identified from the message. SSB=E8A2 was
also output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) UR Open or Mainframe
(2) The following operations are performed in that order.
(a) Creation of 2 or more pairs with the same JNLG# and same
mirror# is preset from Storage Navigator, and one of the two creating
operations is intentionally ended in failure.
(b) Another pair is successfully registered and the failed creation
remains in the preset.
(c) The pair in preset is edited to replace the serial number with an
invalid value and then pair registration is retried.
* JNLG# and mirror# set in (c) are the same as those in (a), and other
parameters are correct.
Causes and Updates The micro-program has been modified to output the correct Storage
Navigator message as follows in this case.
(6505-78270) Pair creation failed because the serial number, the
controller ID, and the path type of the specified secondary storage
system are invalid.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
SVP: All
Fixed Product/Version DKCMAIN: 70-04-01-00/00
SVP: 70-04-01/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN
HDS Confidential 62 of 71
155 No guard of reverse resync operation between I and R site
Phenomena In 3DC cascade configuration with 3 UR/URz sites, a reverse resync
operation for a pair between I site and R site after a pair between P site
and I site was suspended was not guarded.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Open or Mainframe
(2) 3DC cascade configuration with 3 UR/URz sites
(3) A pair between P site and I site is suspended.
(4) Reverse resync operation performed for a pair between I and R site.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN
HDS Confidential 63 of 71
158 Failure of IP address setting
Phenomena When an IP address was changed to 126.255.255.15 by Install-
SetIPAddress of SVP, if SVP was rebooted, the IP address became
169.254.xxx.xxx. After that, Storage Navigator could not be activated.
If the Maintenance window of SVP was opened, SVP message
STA0117E (An error occurred in the Communication between the SVP
and DKC.) appeared and DKC information could not be obtained.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when the same IP address exists on the same
network.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Open or Mainframe
Changed Part SVP
HDS Confidential 64 of 71
161 Excessive time for status transfer at delta resync operation
Phenomena When a pair for delta resync was created and then a delta resync
operation was executed in 3DC cascade configuration with 3 UR sites,
the delta resync operation succeeded but some pairs took a longer time
for status transfer from Copy to PAIR compared to other pairs in the
mirrors.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open
(2) 3DC cascade configuration with 3 UR sites
(3) In a different configuration (other than above), the following
operations are executed.
(a) UR pair creation
(b) Suspend
(c) An I/O
(d) UR pair deletion
(4) After the above operations of (3), a UR pair for delta resync is
created in the configuration of (2).
(5) A delta resync operation is executed.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN
HDS Confidential 65 of 71
164 SSB=D055 output every 10 minutes
Phenomena When a UNMAP command was issued to an area where a pool VOL
with DP/DT VOL allocated was blocked, SSB=D055 was output every
10 minutes.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a pool area of DP/DT-VOL that receives a
UNMAP command is blocked.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Dynamic Provisioning, Dynamic Tiering
Changed Part DKCMAIN
HDS Confidential 66 of 71
167 Failure of Long Range monitoring data backup
Phenomena For Long Range monitoring data of Performance Monitor, the
following phenomena (1) and (2) alternately occurred for each set of
monitoring data for 3 months.
(1) The data was not backed up in standby SVP.
(2) The data at 0:00 every day was not backed up.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Dual SVP configuration.
(2) Monitoring data of Performance Monitor is obtained. (Monitoring
switch is ON.).
(3) Switching between the master and standby SVPs.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Performance Monitor
Changed Part SVP
168 Invalid pair status at restore copy for CoW Snapshot pair
Phenomena When a restore copy was performed for a CoW Snapshot pair, the pair
status did not become Suspend.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A restore copy is requested for a CoW Snapshot pair.
(2) A failure that disables the restore copy is detected.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Copy-on-Write Snapshot
Changed Part DKCMAIN
HDS Confidential 67 of 71
170 Frequent output of SSB=50CC at I site
Phenomena When a cache PCB failure blockage occurred at I site in a URxUR
cascade configuration and a failure suspension occurred between I site
and R sites (SSB=EFCB & ECE6), SSB=50CC was output at I site.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open UR/UR cascade configuration
(2) Cache PCB failure blockage occurs at I site.
(3) Suspension occurs between I and R site. (SSB=EFCB and ECE6)
Affected Products/Version DKCMAIN: 30-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN
HDS Confidential 68 of 71
173 Unable to correct parameters for UR/URz pair creation
Phenomena During UR/URz pair creation for the 2nd mirror UR/URz pair on the
Universal Replicator window of Storage Navigator, an incorrect
parameter was specified.
To correct the parameter, when some pairs displayed in Preview were
selected and then pair creation window was opened again, parameters
such as serial number were fixed and could not be changed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when some pairs displayed on the Preview list are
selected and pair creation window is opened at UR/URz pair creation
for the 2nd mirror UR/URz pair.
The problem does not occur if all of the displayed pairs are selected.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-04-01/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part SVP
HDS Confidential 69 of 71
176 Invalid UR pair status at pair deletion/suspend
Phenomena When a pair deletion was performed for a pair between P site and R
site in UR 3DC (URxUR cascade or URxUR multi-target) delta
configuration, the pair status remained Deleting.
In the case of a pair suspend operation, the pair status remained
Suspending.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator
(2) An old delta configuration of URxUR cascade delta configuration
or URxUR multi-target delta configuration (without UR control path
registration)
(3) UR pair deletion or suspend is performed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN
* The problem occurs only when sending message for job activation
fails (internal condition), and therefore the probability is low.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category Universal Replicator
Changed Part DKCMAIN
HDS Confidential 70 of 71
178 Failures of relationship status display on Storage Navigator
Phenomena Phenomenon1
When an FCv2 relationship was created while sharing the source VOL
(S-VOL) with an already-created FCSE relationship, the S-VOL of
FCv2 did not become Normal status on Storage Navigator.
Phenomenon2
When an FCSE relationship was created while sharing S-VOL with an
already-created FCv2 relationship, the S-VOL of FCSE did not
become Normal status on Storage Navigator.
Phenomenon3
When an FCv2 relationship was deleted while FCSE and FCv2 shared
S-VOL, the S-VOL of FCv2 remained in Normal status on Storage
Navigator.
Phenomenon4
When an FCSE relationship was deleted while FCSE and FCv2 shared
S-VOL, the S-VOL of FCSE remained in Normal status on Storage
Navigator.
Phenomenon5
When FCSE and FCv2 shared S-VOL and both relationships were in
Suspend status, if the relationship in Suspend status was deleted, the
status remained SUS on Storage Navigator.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
Phenomenon1
(1) FCSE relationship configuration
(2) An FCv2 relationship is created by using S-VOL of the FCSE
relationship.
Phenomenon2
(1) FCv2 relationship configuration
(2) An FCSE relationship is created by using S-VOL of the FCv2
relationship.
Phenomenon3
(1) FCSE and FCv2 relationships share the same S-VOL.
(2) The FCv2 relationship is deleted.
Phenomenon4
(1) FCSE and FCv2 relationships share the same S-VOL.
(2) The FCSE relationship is deleted.
Phenomenon5
(1) FCSE and FCv2 relationships share the same S-VOL and the both
relationships are in Suspend status.
(2) Other than the above, there is another FCSE/FCv2 relationship that
uses the same S-VOL and the relationship is not in Suspend status.
(3) The FCSE/FCv2 relationship in suspend status is deleted.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-04-01-00/00
Category FlashCopy version2, FlashCopy SE
Changed Part DKCMAIN
HDS Confidential 71 of 71