Certified Accessories Technical Specifications

Device Manufacturer Power supply Value


USB contact interface Ontrak Nominal voltage 230V AC
OpenStage Xpert handset with mute/PTT Unify Voltage range 100 – 240 V AC, 50-60 Hz, 1.5A
(Push To Talk) key and rocker with cradle Power consumption max. 65 W
OpenStage Xpert handset VC with volume Unify Bridging of voltage gaps 10ms
control, mute/PTT key and rocker
Output voltage 12V DC
OpenStage Xpert handset with PTM key CLEARTEL
Max. output current 5.0A
(Push To Mute)
OpenStage Xpert handset with PTT key and CLEARTEL Standby power consumption max. 1 W
rocker OpenStage Xpert 6010p V1R1 max. 25 W
without additional USB devices
OpenStage Xpert handset with PTT key and CLEARTEL
rocker; PJ7 connector OpenStage Xpert 6010p V1R1 with max. 45 W
additional USB devices
OpenStage Xpert handset with PTT key CLEARTEL
OpenStage Xpert handset with PTT rocker CLEARTEL Environmental Conditions Value
OpenStage Xpert handset CLEARTEL Storage climate -25...+55°C
Headset CA12CD-PTT DECT wireless PLANTRONICS Transport climate -25...+70°C
Headset PRO GN9470 DECT wireless JABRA/GN-Netcom Operation climate +5...+40°C

DHSG supported GN Jabra Pro 9470 Dect JABRA/GN-Netcom Mechanical data Value
wireless headset Width × Depth × Height ca. 338x193x60 mm
DHSG supported GN Jabra Pro 9450 Dect
wireless headset
JABRA/GN-Netcom Fastening Stand alone,
Inclination of angle adjustable, OpenStage Xpert
DHSG supported GN Jabra Go 6470 Dect
wireless headset
JABRA/GN-Netcom
Weight
75mm VESA support
ca. 2.6 kg 6010p V1R1
Gooseneck microphone for mounting on the CLEARTEL Communication Value
OSXpert6010p/Speaker Module without
LED light-ring GOSSIE07
Ethernet 2 x 10/100/1000 First Installation Guide
USB 6 x V2.0, 480Mbps, max.
Gooseneck microphone with LED light-ring CLEARTEL
Audio 1 x DHSG
(USB controlled) for mounting on the This First Installation Guide is addressed to Service
5 x Output
OSXpert6010p/Speaker Module GOSSIE09 Technicians. It is intended to support for setting up the
3 x Handset
Multimedia speaker Companion® 2 Series II BOSE device and getting started. For more detailed information
PSU 100-240 V AC/12V, 60W, Model No. Kaga Electronics Display Value on your device and its features, refer to the corresponding
KTPS65-1250DT-3P (USA) Inc. Technology TFT Display with touch screen documentation on www.unify.com
OSXpert Speaker Module (up to 2 pcs.) Unify function
Resolution SVGA (800 x 600)
Important: Diagonal 10,4"
• Connect only certified accessories! Color depth 24 bit
• For more information about accessories please contact Backlighting LED
your country-specific Unify organization. Processor Value
CPU Intel Atom E3845 1.91 GHz
quad core processor
Working storage 2 GByte
© Unify Software and Solutions GmbH & Co. KG
Mass storage Compact Flash 8 GByte Mies-van-der-Rohe-Str. 6, 80807 Munich/Germany
All rights reserved. 03/2017
Reference No.: A31003-X2040-J102-5-7631

unify.com
General Information First: Prepare for Installing Second: Interconnect the Device
Scope of Delivery • Place the device on a non-slip, insensible base. Position When connecting the OpenStage Xpert 6010p V1R1 it is
the device in such a way that it is stable and that the ven- important to strictly follow the given order of the instructions
Open the packaging carefully and verify the components tilation slots are not covered. and to observe the notes about place of use!
delivered match the components listed below. • The two stand elements and the embedded ratchet lever Note:
• OpenStage Xpert 6010p V1R1 device allow to arrange the device in the desired tilt angle in a Do not connect any lines to the device’s loudspeaker input
• Power supply range between 20° and 60°. jacks since otherwise circuits required are deactivated!
• Power cord • As an alternative, the device can be mounted on a monitor 1. Connect to the customer network (LAN 1 jack).
Important Information bracket arm (system VESA 75 mm). Moreover the device 2. Connect USB keyboard and USB mouse to the USB 3
can be integrated in a table provided that there is sufficient und USB 4 jacks (recommended during installation).
Never open the device. If you encounter any problems, air circulation. 3. Connect handsets and loudspeakers, add-on devices
contact System Support. Clean the touch screen and the • Note: according to the requirements. Only certified accesso-
housing only with special cleaning wipes for TFT displays. The removal/assembling of the stand elements is carried ries may be connected!
Before installing the device please read carefully the safety out in hinged position (see figure). 4. Choose a position where no reflections appear on the
instructions in the OpenScape Xpert Service Manual. touch screen and the keys can be operated in a conve-
Keep the documentation together with the device. If you nient way.
pass the device on to a third party, be sure to pass this doc-
ument too. 5. Connect the power supply.

Marks
The compliance of the equipment according to EU directives is
confirmed by the CE mark. This Declaration of Conformity and,
where applicable, other existing declarations of conformity as well
as further information on regulations that restrict the usage of
substances or affect the declaration of substances used in 6. With the ATX button the OpenStage Xpert 6010p V1R1
products can be found in the Unify Expert WIKI at http:// can be switched on (see Third: Initial Operation).
wiki.unify.com under the section “Declarations of Conformity”. 7. Later on the OpenStage Xpert 6010p V1R1 can be
All electrical and electronic products should be disposed of switched off using the ATX button on the rear side or
separately from the municipal waste stream via designated via the Diagnosis tool.
collection facilities appointed by the government or the local Notes about place of use
authorities. The correct disposal and separate collection of your old
appliance will help prevent potential negative consequences for • The device should be operated in a controlled environment
the environment and human health. It is a precondition for reuse
and recycling of used electrical and electronic equipment. For
with an ambient temperature between 5 °C and 40 °C
(41 °F and 104 °F) and a humidity between 5% and 85%.
Third: Initial Operation
more detailed information about disposal of your old appliance,
please contact your city office, waste disposal service, the shop • Because the device is cooled passively, the waste heat After switching on the first time the OpenStage Xpert 6010p
where you purchased the product or your sales representative.
The statements quoted above are only fully valid for equipment generated is channelled off via the rear side of the casing. V1R1 is not yet ready to use. The following steps have to
which is installed and sold in the countries of the European Union The rear side of the casing and the whole device can heat be taken:
and is covered by the directive 2002/96/EC. Countries outside the up. Ensure an adequate distance (minimum 200 mm) to 1. Load the runtime image:
European Union may have other regulations regarding the
disposal of electrical and electronic equipment. other objects to provide sufficient ventilation. • Remote method:
• Do not expose the device to direct sunlight or any other After switching on the device, the pre-installed operat-
Note (U.S.A. and Canada only): source of heat, as this is liable to damage the electronic ing system ("tiny linux") starts up and requests an IP
This device has been tested and found to comply with the limits for equipment and the plastic casing. address from a pre-configured DHCP server. OSX Di-
a Class B digital device, pursuant to Part 15 of the FCC Rules. agnosis tool can be used to load the 6010p V1R1 run-
These limits are designed to provide reasonable protection against Connectors time Linux image. Please refer to the OpenScape Xpert
harmful interference when the equipment is operated in a Service Manual - Central Image Distribution section.
residential installation. This device generates, uses, and can All connectors are located on the rear side of the equipment.
• USB stick method:
radiate radio frequency energy and, if not installed and used in USB restore stick can be used to load the 6010p V1R1
accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that runtime Linux image.
interference will not occur in a particular installation. If this • USB1...6: Jacks for peripheral equipment USB 2.0 Note: The required drivers and application specific settings
equipment does cause harmful interference to radio or television • HS4: Jack for Headset (DHSG) have been provided ex works.
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by • HS1...3: Jacks for handsets/microphone. 2. Software installation via the OSX Diagnosis tool is
one or more of the following measures: • LineOUT -/3: Jack for external loudspeaker required before the OpenStage Xpert 6010p V1R1 is
• Realign or move the receiving antenna • LineOUT R/L (LS int.) Line in for internal loudspeakers ready for operation. Please refer to the Service Manual
• Adjust the distance between the device and receiver • LineOUT 1/2: Jack for external loudspeakers for initial software installation on Linux clients.
• Consult the dealer or an radio/TV technician for help
This product is UL listed for U.S.A. and Canada. This equipment • LAN1, 2: Jacks for network cable 10/100/1000 BT System Manager is used for any subsequent software up-
also complies with the Part 68 of the FCC Rules and the Industry • 12 V 5A: Power supply (power adapter) grade. Please contact the system administration for soft-
Canada CS-03. ware installation and configuration.