Voltage Drop Calculations


The voltage drop of any insulated cable is dependent upon the route length under consideration (in meters), the required current rating (in amperes) and the relevant total impedance
per unit length of the cable. The maximum impedance and voltage drop applicable to each cable at maximum conductor temperature and under a.c. conditions is given in the tables.
For cables operating under dc conditions, the appropriate voltage drops may be calculated using the formula.

“ 2 x route length x current x resistance x 10¯³.

The values detailed in the tables are given in m/V/Am, (volts/100 per ampere per metre), and the nominal
maximum acceptable volt drop specified by the IEE Regulations is 2.5% of the system voltage, i.e. 0.025 x 415
= 10.5 volts for 3 phase working or 0.025 x 240 = 6.0 volts for single phase working.

Consider a 3 phase system


The requirement may be for a load of 1000A to be transmitted over a route length of 150m, the cable to be
clipped to the wall and close protection provided. The rating tables in the IEE Regulations indicate that a
35mm copper conductor PVC SWA PVC cable would be suitable for the loading required, but the voltage drop
must be checked.

Volt drop = Y x current x length


= 1.1 x 100 x 150 millivolts
= 1.1 x 100 x 150 volts/1000
= 16.5 volts

Privacy & Cookies Policy


https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 1/15
9/2/2019 Voltage Drop Calculations

where Y = value from tables in mV/A/m Unless a particular value of voltage drop, acceptable to the user, is
specified, the IEE Regulations figure of 10.5 volts must be adhered to.

Thus: total volt drop = 10.5 volts


10.5 = Y x 100 x 150
Therefore Y = 10.5/100 x 150
= 0.7/1000 volts/ampere/meters

Reference to the voltage drop tables indicates that the cable size with a voltage drop of 0.7/1000 V/A/m
(0.7mV/A/m) OR LESS is a 70mm copper conductor.
Therefore, in order to transmit a 3 phase current of 100A per phase over a route length of 150m, with a total
voltage drop equal to or less than the statutory maximum 10.5 volts, the use would require a
70mm (cu.) multicore PVC.

Conversely
The user may have 150m of 35mm (Cu.) multicore PVC cable and require to know what maximum current
rating can be applied without exceeding the allowable voltage drop. The method is exactly the same as above,
viz:total drop = 16.6

= YxAxM
= 1.1 x A x 150/1000
from the tables Y = 1.1mV/A/m
=1.1/1000V/A/m
therefore A = 10.5 x 1000/1.1.x 150
=64 amperes

From the foregoing, it is apparent that knowing any two values of Y, A or m, the remaining, unknown value can
readily be calculated.
The advice is always available to check, clarify or suggest the most suitable size and type of cable for any particular, specified requirements.

Voltage Drop for Single Core LV Cables (mV / amp / metre)

Copper Conductor >Flat Arrangement Trefoil arrangement Aluminium conductor Flat arrangement Trefoil arrangement
4 7.83 7.770 16 3.343 3.283
6 5.287 5.226 25 2.161 2.100
10 3.184 3.124 35 1.602 1.542
16 2.086 2.008 50 1.222 1.162
25 1.357 1.297 70 0.890 0.830
35 1.034 0.971 95 0.686 0.623
50 0.793 0.732 120 0.569 0.509
70 0.595 0.534 150 0.490 0.430
Privacy & Cookies Policy
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 2/15
9/2/2019 Voltage Drop Calculations

95 0.469 0.408 185 0.420 0.360


120 0.410 0.349 240 0.353 0.293
150 0.354 0.294 300 0.312 0.252
185 0.312 0.252 400 0.274 0.214
240 0.272 0.211 400 0.245 0.185
300 0.247 0.187 630 0.222 0.162
400 0.224 0.164
500 0.208 0.148
630 0.194 0.134

VOLTAGE DROP PER AMPERE PER METER (mV). Conductor operating temperature: 70ºC

Conductor Cross Sectional Area Two Core Cable D.C. Two Core Cable SIngle Phase A.C. Three or Four Core Cable Three phase A.C.
mm mV mV mV
1.5 29 29 25
2.5 18 18 15
4 11 11 9.05
6 7.3 7.3 6.04
10 4.4 4.4 3.08
16 2.8 2.8 2.04
r x z r x z
25 1.75 1.75 0.170 1.75 1.50 0.145 1.50
35 1.25 1.25 0.165 1.25 1.10 0.145 1.10
50 0.93 0.93 0.165 0.94 0.80 0.140 0.81
70 0.63 0.63 0.160 0.65 0.55 0.140 0.57
95 0.46 0.47 0.155 0.50 0.41 0.135 0.43
120 0.36 0.38 0.155 0.41 0.33 0.135 0.35
150 0.29 0.30 0.155 0.34 0.26 0.130 0.29
185 0.23 0.28 0.150 0.29 0.21 0.130 0.25
240 0.180 0.190 0.150 0.24 0.165 0.130 0.21
300 0.145 0.155 0.145 0.21 0.136 0.130 0.185

Privacy400
& Cookies Policy 0.105 0.115 0.145 0.185 0.100 0.125 0.160

https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 3/15
9/2/2019 Voltage Drop Calculations

VOLTAGE DROP PER AMPERE PER METRE (mV). Conductor operating temperature: 70ºc

Conductor Cross-Sectional Area Two Core Cable D.C. TWo Core Cable Single Phase A.C. Three or Four Core Cable Three Phase A.C.
1 2 3 4
Mm Mv MV MV
16 4.5 45 3.9
25 2.9 29 0.175 2.9 2.5 0.150 2.5
35 2.1 2.1 0.170 2.1 1.80 0.150 1.80
50 1.55 1.55 0.170 1.55 1.35 0.145 1.35
70 1.05 1.05 0.165 1.05 0.90 0.140 0.92
95 0.77 0.77 0.160 0.79 0.67 0.140 0.68
120 – – 0.53 0.135 0.55
150 – – 0.42 0.135 0.44
185 – – 0.34 0.135 0.37
240 – – 0.26 0.130 0.30
300 – – 0.21 0.130 0.25

Tables derive from IEE copyright information

PVC INSULATED 600/1000 VOLT CABLES WITH COPPER CONDUCTORS SUSTAINED CURRENT RATING (AMP)
(50Hz) PARAMETERS

600/100 VOLT
Normal Conductor Area
THREE-PHASE SINGLE CORE CABLES IN TREFOIL ARRANGEMENT
mm Direct Armoured Duct Armoured Air Unarmoured Air Armoured
50 203 199 184 193
70 248 241 233 249
95 297 282 290 298
120 337 311 338 347
150 376 342 338 395
185 423 375 450 452
240 485 419 537 532
300 542 459 620 607
Privacy & Cookies Policy
700 600 489 722 690
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 4/15
9/2/2019 Voltage Drop Calculations

500 660 523 832 776


630 721 563 957 869
800 758 587 1083 937
1000 797 621 1260 1010

APPROXIMATE CURRENT PER LINE OR PHASE TAKEN AT FULL RATED HP BY MOTORS OF AVERAGE
EFFICIENCY AND POWER FACTOR

Motor Rating Direct Current Alternating Current


110V 220V 550V 240V 380V 415V 550V
HP amp amp amp amp amp amp amp
0.5 5.7 2.8 1.1 3
1 10 5 2 6 1.9 1.7 1.3
2 18 9 3.6 10 3.6 3.3 2.5
3 26 13 5.2 15 5.1 4.6 3.5
5 42 21 8.4 24 8 7.3 5.5
7.5 60 30 12 35 11.6 10.6 8
10 80 40 16 46 15.1 13.8 10.4
15 117 59 23 67 22 20 16
20 154 77 31 88 29 27 21
25 190 95 38 110 37 34 26
30 227 114 46 130 43 40 30
40 300 150 60 180 59 54 41
50 375 187 75 210 73 67 50
50 445 223 89 253 87 80 60
60 520 260 104 291 102 94 70
80 600 300 120 332 117 107 81
100 740 370 148 412 145 133 100
125 460 184 515 181 166 125
150 220 217 199 150
175 256 253 232 175
Privacy200
& Cookies Policy 292 288 264 199

https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 5/15
9/2/2019 Voltage Drop Calculations

250 353 323 244


300 421 385 291

Useful three phase formulae:


1. kW = kVA x power factor

Line amps x Line volts x 1.73 x p.f.


2. kW =
1000

kW
3. kVA =
p.f.

4. Line amps kW x 1000


= Line volts x 1.73 x p.f.

5. Line amps kVA x 1000


= Line volts x 1.73

h.p. x 746
6. Line amps
Line volts x 1.73 x Efficiency x
=
p.f.

Line amps x Line volts x 1.73


7. kVA =
1000

h.p. x 746
8. kW =
1000 x Efficiency

9. kVA = Line amps x Line volts x 1.73 x Efficiency x


Privacy & Cookies Policy
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 6/15
9/2/2019 Voltage Drop Calculations

p.f.
746

kW x 1000 x Efficiency
10. h.p. =
746

kVA x 1000 x Efficiency


11. h.p. =
746

CURRENT RATINGS OF CABLES CLIPPED DIRECT TO SURFACE OR TRAY BUNCHED AND UNENCLOSED

3 One-Core 1 Three Core


2 ONe-Core D.C. 1 Two Core DV
4 One-Core 1 Four Core
Conductor Size
One Phase A.C. Three Phase A.C. One-Phase A.C. Three Phase A.C.
R P R P R P R P
mm2 amp amp amp amp amp amp amp amp
1 16 13 15 12 14 12 12 10
1.5 21 16 19 15 18 15 15 13
2.5 29 23 26 20 24 21 21 18
4 38 30 34 27 31 27 27 24
6 49 38 45 34 40 35 35 30
10 67 51 60 46 56 48 48 41
16 90 38 81 61 72 64 64 54
25 115 89 105 80 96 71 84 62
35 145 109 130 98 115 87 100 72
50 205 175 185 160 170 140 150 125
70 260 220 235 200 210 175 185 155
95 320 270 285 240 255 215 225 190
120 370 310 335 280 300 250 260 215
150 420 355 380 320 335 285 300 250
185 480 405 435 365 385 325 345 280
Privacy & Cookies Policy
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 7/15
9/2/2019 Voltage Drop Calculations

240 570 480 520 430 450 385 400 335


300 660 560 600 500 520 445 460 390
400 770 680 700 610
500 890 800 800 710
630 1050 910 950 820

CURRENT RATINGS OF CABLES IN CONDUIT OR TRUNKING BUNCHED AND ENCLOSED

2 One Core D.C. 4 One Core D.C. Three Phase A.C.


Conductor Size
One Phase AC Three Phase AC One Phase AC
R P R P R P R P
mm2 amp amp amp amp amp amp amp amp
1 14 11 11 9 12 11 10 9
1.5 17 13 14 11 15 13 13 12
2.5 24 18 20 16 20 18 17 16
4 31 24 27 22 27 24 23 22
6 40 31 35 28 34 30 30 27
10 55 42 49 39 47 40 41 37
16 73 56 66 53 61 53 54 47
25 94 73 89 71 80 60 70 53
35 115 90 110 88 97 74 86 65
50 170 145 145 125
70 215 185 185 160
95 265 230 225 195
120 310 260 260 220
150 350 300

R = Heat-resisting rubber insulation


P = PVC insulation

MINIMUM SIZE OF EARTH CONDUCTOR (IF NOT CONTAINED IN CABLE)

Size of largest associated copper circuit


Size of Earthing Conductor Size of Earthing Continuity Conductor Size of Bonding Lead
conductor
Privacy & Cookies Policy
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 8/15
9/2/2019 Voltage Drop Calculations

1 6 1* 1#*
1.5 6 1* 1#*
2.5 6 1* 1#*
4 6 2.5 1#*
6 6 2.5 1#*
10 6 6 2.5
16 6 6 2.5
25 16 16 6
35 16 16 6
50 16 16 6
70 50 50 16
95 50 50 16
120 50 50 16
150 50 50 16
185 70 70 50
240 70 70 50
300 70 70 50
400 70 70 50
500 70 70 50
630 70 70 50

* 1.5 sq mm where earth conductor in unenclosed


# 2.5 sq mm for bonding other services at entry to premises.

DIAMETERS AND GLAND SIZES OF ARMOURED PVC INSULATED CABLES

Max. Diameter of Recommended Gland


Conductor Size No. of Cores Approximate Diameters Wire
Core Size#
Bedding Sheath Armour Oversheath
Sq. mm mm No. of Cores mm mm mm mm BS4121
14/8 26/8 2 7 9 11 6/8 7/8 5/8
3 73/8 9 3/8 12 2/8 7/8 5/8
4 8.1 10.1 13 0.9 3/4 S*
5 8.9 10.9 13.8 0.9 3/4 S
Privacy & Cookies Policy
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 9/15
9/2/2019 Voltage Drop Calculations

7 9.7 11.7 14.5 0.9 3/4 S


10 12 2/4 15 18 1 1/4 3/4
12 12 3/4 15 2/4 18 2/4 1 1/4 3/4
19 15.1 17.8 21.1 1.25 1
27 18.5 22 25.4 1.6 1
37 21 24 2/4 17 3/4 1 2/4 1 3/4
48 23 3/4 27 1/4 30 3/4 1 2/4 1 3/4
2.5 3.3 2 8.2 10.2 13.1 0.9 3 3/4 S*
3 8.7 10.7 13.6 0.9 3 3/4 S
4 9.6 11.6 14.5 0.9 3 3/4 S
5 10.5 12.5 15.4 0.9 3 3/4
7 11 2/4 12 2/4 16 2/4 1 3/4
10 14.8 17.5 20.9 1.25 1
12 15.3 18 21.4 1.25 1
19 18.5 22 25.4 1.6 1
27 22 25 2/4 29 1/4 1 2/4 1 3/4
37 25 28 2/4 32 2/4 1 2/4 1 3/4
48 29 33 1/2 37 1/2 2 1 1/2
4 4.3 2 10.2 12.2 15.1 0.9 3 3/4 S
3 11 13 16 1 3/4
4 12 14 3/4 17 3/4 1 1/4 3/4
5 12 1/4 16 19 1 1/4 3/4
7 14 2/4 17 1/4 20 2/4 1 1/4 1
10 19 1/4 22 3/4 26 1 2/4 1
12 19.8 23.3 26.8 1.6 1 3/4
19 12 2/4 27 30 2/4 1 2/4 1 1/4
27 28 1/2 33 37 2 1 1/2
6 5 2 11 2/4 13 2/4 16 2/4 1 3/4
3 12 1/4 12 1/4 18 1 1/4 3/4
4 13 2/4 13 2/4 19 1/4 1 1/4 3/4
10 61/4 2 14 16 3/4 20 1 1/4 3/4

Privacy & Cookies Policy 3 15 17 3/4 21 1/4 1 1/4 1

https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 10/15
9/2/2019 Voltage Drop Calculations

4 16 2/4 19 1/4 22 3/4 1 1/4 1


16 Shaped Conductors 2 13 15 2/4 19 1 1/4 3/4
3 14 2/4 14 2/4 20 2/4 1 1/4 1
4 19 3/4 16 3/4 24 1 1/4 1

#Glands Type BW, CW, D1W, D2W, E1W, E2W.


• A cable made to minimum tolerance may be accommodated in a gland one size smaller.

GLAND SIZING CHART PVC/SWA/PVC CABLES

Cores
Size MM Sq
1 2 3 4 5 7 10 12 19 27 37 48
1.5 16/20 16/20 20S 20S 20S 20L 20L 25S 25L 32 32
2.5 20S 20S 20S 20S 20L 25S 25S 25L 32 32 40S
4.0 20S 20L 20L 20L 20L 25L 32 32 40S
6.0 20L 20L 20L
10.0 25S 25S 25S
16.0 25S 25L 25L
25.0 25S 32 32
35.0 25L 32 32
50.0 32 32 40S
70.0 32 40S 40L
95.0 25S 40S 40S 50S
120.0 25L 40S 40L 50S
150.0 32 40L 50S 63S
185.0 32 50S 50L 63S
240.0 40S 50L 63S 63S
300.0 40L 63S 63L 75L
400.0 50S 63L 75S 75L
500.0 50S
630.0 50L

The gland sizes tabulated are intended as a guide only and are based on the approximate under armour and
overall diameters.

Cables with aluminium wire must have aluminium glands.


Privacy & Cookies Policy
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 11/15
9/2/2019 Voltage Drop Calculations

DERATING FACTORS

GROUND TEMPERATURE DERATING FACTORS

AIR TEMPERATURE DERATING FACTOR

Air Temperature oC 25 30 35 40 45 50 55
PVC cables rated at 70oC 1.22 1.15 1.08 1.00 0.95 0.82 0.71

Burial Depth Derating Factor

Ground Temperature oC 25 30 35 40 45 50 55
o
PVC cables rated 70 C 1.13 1.07 1.00 0.93 0.85 0.76 0.65

Cables Cross Section


Depth of laying mt up to 70 mm sq 95mm sq – 240 mm sq 300 mm sq and above
0.5 1.00 1.00 1.00
0.60 0.99 0.98 0.97
0.80 0.97 0.96 0.94
1.00 0.95 0.93 0.92
1.25 0.94 0.92 0.89
1.5 0.93 0.90 0.87
1.75 0.92 0.89 0.86
2.00 0.91 0.88 0.85

SOIL THERMAL RESISTIVITY DERATING FACTOR

Soil thermal resistivity in °C cm / watt 80 90 100 120 150 200 250


Rating factor 1.17 1.12 1.07 1.0 0.91 0.80 0.73

PVC Rated Temperature Derating Factor

Type of PVCPrivacy & Cookies oPolicy


rated temperature C 70 85 95 105
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 12/15
9/2/2019 Voltage Drop Calculations

Rating Factor 1.000 1.195 1.309 1.414

Follow Us

Buy On-Line

Technical Tables
Power Cable
Flexible Rubber Cable
Flexible Control Cable
High Temperature Cable
Events Cable
Data / Telephone Cable
Fire Resistant Cable
VFD Cable
Nexans Cables
Robotics and Crane Cables
Mining Cable
Fibre Optic Cable
Automotive Cable
Technical Tables / Useful Info
Table 4D1A
Table 4D2A
Table 4D2B
Table 4E1A
Table 4E1B
Table 4E2A
Table 4E2B
Privacy & Cookies Policy
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 13/15
9/2/2019 Voltage Drop Calculations

Table 4E3A
Table 4E3B
Table 4E4A
Table 4E4B
Table 4F1A
Table 4F1B
Table 4F2A
Table 4F2B
Table 4F3A
Table 4F3B
AWG/Metric Conversion
Stranding Chart
BS 5308 Colour Codes
Harmonised Cable Core Colours
Cable Certifications
Cable Colours
DIN 47100 European Colour Codes
Fire Performance Cable Standards
Voltage Drop Calculations

Cart
No products in the basket.

Buy On-Line Pay Securely with SagePay Follow Us


We process all our on-line shopping transactions with Sagepay.

Popular Links
Below are quick links to our most popular products:

Gewiss GW44 Enclosures


Policy Links H07RN-F Cable
Privacy
Privacy and Cookie Policy & Cookies Policy YY Cable
https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 14/15
9/2/2019 Voltage Drop Calculations

Terms and Conditions SY Cable

Cable Glands
CSE Cables Eldon Enclosures

CSE Cables is now incorporated within CSE


Distributors. Product Information
Cable

ABB Drives

Motor Control Gear

Circuit Protection

Switchgear

Danfoss Industrial Controls

Danfoss Drives

Cable Management

Control Gear

Tools & Accessories

Power Distribution

Enclosures

Copyright 2001-2016
CSE Southampton Branch : South UK : 023 8025 5757; Fax :023 8027 4082; Email : southampton@cseuk.com
CSE Industrial Electrical Distributors Ltd / CSE Cables; 01628 529448 Fax : 01628 810093; Email : sales@cseuk.com
Tel : International enquiries +44 (0)1628 529448, International Fax - +44 (0)1628 810093

Privacy & Cookies Policy


https://www.cse-distributors.co.uk/cable/technical-tables-useful-info/voltage-drop-calculations/ 15/15

Das könnte Ihnen auch gefallen