Sie sind auf Seite 1von 1

Subject: Date: 04/30/2017

Client: Checked by:


NSCP 2015 SEISMIC ANALYSIS (STATIC FORCE PROCEDURE)
Building Data: Seismic Factors:
 

# suspended floors 5   Importance Factor, I 1   NSCP 2015 Section 208.4.2 (Table 208 1) ‐

Floor Height Dead Load Soil profile type, S SD   NSCP 2015 Section 208.4.3 (Table 208 2) ‐

Level (m) (kN) 0.4   NSCP 2015 Section 208.4.4.1 (Table 208 3)
Seismic Zone factor, Z ‐

5 3.1 4802.6   15.5   Siesmic source Type A   NSCP 2015 Section 208.4.4.2 (Table 208 4) ‐

4 3.1 4802.6   12.4   Near source factor, Na 1.2   NSCP 2015 Section 208.4.4.3 (Table 208 5) ‐

3 3.1 4321.4 9.3   Near source factor, Nv 1.6   NSCP 2015 Section 208.4.4.3 (Table 208 6) ‐

2 3.1 3602.7 6.2   Seismic coefficient, Ca 0.528   NSCP 2015 Section 208.4.4.4 (Table 208 7) ‐

1 3.1 4556.6 3.1   Seismic coefficient, Cv 1.024   NSCP 2015 Section 208.4.4.4 (Table 208 8) ‐

0 0   Structural System Factor, R 6   NSCP 2015 (Table 208 11A to 208 11D) ‐ ‐

‐1 0   Frame material factor, Ct 0.0488   NSCP 2015 Section 208.5.2.2


‐2 0   Base Shear Computation:
Shear  Computation:
‐3 0   Fundamental Period of Vibration:
of  Vibration:
3/4 3/4
‐4 0 TA = Ct(hn) =   0.38
0.381
1 sec
sec C t  (h n ) NSCP 2015 Sec 208.5.2.2 (Method  A)
 A)
‐5 0 TB= sec   (Method B,
(Method  B, Computed using
Computed using Rayleigh method)
‐6 0 T= 0.38 sec controls!
‐7 0   Total Design Base Shear:
‐8 0 V = (CvI/RT) x W = 0.447693
0.447693 W = 9887.70 kN
kN   NSCP 2015 Section 208.5.2.2 (Eq. 208 8)

‐9 0 The total design base shear need not exceed:


‐10 0 V = (2.5CaI/R) x W = 0.22
0.2200
00 W = kN (✔)   NSCP 2015 Section 208.5.2.2 (Eq. 208 9)
4858.90 kN ‐

‐11 0 The total base shear shall not be less than:


‐12 0 V = (0.11CaI) x W = 0.05808 W = 1282.75 kN
kN   NSCP 2015 Section 208.5.2.2 (Eq. 208 10)

‐13 0 For seismic Zone 4, the total base design shear shall not be less than:
‐14 0 V = (0.8ZNVI/R) x W =   0.085333 W = 1884.66 kN
kN   NSCP 2015 Section 208.5.2.2 (Eq. 208 11)

TOTAL:   15.
15.5
5 2208
22085.
5.9
9 The Total Base Design Shear = 0.22 W = 4858.9
4858.9 kN

Floor wh Force at top due to whiplash effect


w (kN) h (m) F (kN)
level (kN m)

for T ≤ 0.7 0
5 4802.6 15.5 74440.3 1717.11 for 0.7 < T <3.6 0.07TV =   129.66 Ft = 0 kN
4 4802.6 12.4 59552.2 1373.69 for T ≥ 3.6   0.25V =   1214.72
3 4321.4 9.3 40189 927.04
2 3602.7 6.2 22336.7 515.24
1 4556.6 3.1 14125.5 325.83   Vertical Distribution of forces:
of  forces:
0 0 0 0 0.00
‐1 0 0 0 0.00   Level n Fn
‐2 0 0 0 0.00   Level 8 F8
‐3 0 0 0 0.00   Level 7 F7
‐4 0 0 0 0.00   Level 6 F6
‐5 0 0 0 0.00   Level 5 F5   1717.11
1717.11 kN
‐6 0 0 0 0.00   Level 4 F4   1373.69
1373.69 kN
‐7 0 0 0 0   Level 3 F3   927.
927.04
04 kN
‐8 0 0 0 0   Level 2 F2   515.
515.24
24 kN
‐9 0 0 0 0   Level 1 F1   325.
325.83
83 kN
‐10 0 0 0 0
‐11 0 0 0 0
‐12 0 0 0 0 *n = uppermost  level (for 
level (for n>8)
n>8)
‐13 0 0 0 0   *Level 1
*Level  1 is the first 
the first suspended 
suspended  floor above
 floor above the ground 
‐14 0 0 0 0   *References: ∙National Structural 
National Structural Code
Code of the
of  the Philippines 201
Σ =   22085.9   210643.8 Uniform Building Code (UBC) 1997 

*Programmed  by: Kevin Saluague (kevinsaluague09@gmail.com) Wind and 


Wind  and Earthquake
∙ Earthquake Resistant Buildings
Resistant Buildings by Taranath,
by Taranath, Bungal 

Das könnte Ihnen auch gefallen