Nokia AirScale Macro FDD-LTE Radios Nokia AirScale Radio Description
7 Nokia AirScale Macro FDD-LTE Radios
7.1 Descriptions of RF modules
7.1.1 Nokia AirScale RFM 6T6R B3 480 W (AREA)
| AREA is introduced by LTE#208: Nokia AirScale RFM 6TER B3 460 W (AREA).
Functional description
Table § AREA functional specification
Property Vale
‘Output power exeoW
‘GAN modulation 258 QAM DL)
Joa can uty
‘Number of TXRX [BTXORK
‘Outdoor instalation ves
‘SW supported echnologios| [SM FODLTE,
Datrequency range
[1605 — 1880 MAE
RX frequency range
1710 1785 Ne
Di instentansous bandwidth
Se
UL instantaneous bandwidth
Fe ne
Di fiter banda
rs Me
UL iter Banca
7S
‘Supported bandwidths
14,3,5,10, 15, 20M
Pn canesiiation
Yes
Interfaces
Figure 3 AREA interfaces
ANT6 ANTS ANT4 ANT3 _ANT2 ANT?Nokia AirScale Radio Description Nokia AirScale Macro FDD-LTE Radios
Table9 AREA interfaces
Interface |Labelonthe HW] Number af | Connector type | Additional info
Interfaces
Power Connector [DC IN 1 pole Screw
orminal for 25
nun? shielded
cable
‘Anienna ANT 6 10
‘connector
Remote Eleotrical [RET Fr apn ercular [R485
Tit
‘La (Local EAC 1 oR26
Management
Interface and
EAC)
Optical interface OPT 3 SFP fe aGaits CPRE
Nokia IP sea
‘Grounding TL 7 lax NS screw
Antenna Line Devices (ALDs) support
Table 10 AREA ALD support
‘ALD support via RS486i8-pin circular ports Value
AISG. JANT, ANTS, ANTS: AISG 2.08.0
JANT2, ANTS, ANTS: AISG 3.0 ping receiver
RET AISG 30
Vvotage RET 45V)
Power per port [sow
Functional block diagramNokia AirScale Macro FDD-LTE Radios Nokia AirScale Radio Description
Figure 4 AREA functional block diagram
RF Mode
Electrical specifications
Table 11 AREA electrical specifications
Property Value
Nominal supply volta -a8.0 ve
‘Nominal input valage range
pans VOC STOVE
‘Exlanded inpul voltage range [80 V Det 405 VDE
-57.0 VDC 10-600 DeInstallation and mechanical specifications
Table 14 AREA installation and mechanical specifications
Property Value
Installation options + Pole installation (vertical)
+ Wall installation (vertical)
+ Stack
+ Inside cabinet
IP rating PES,
‘Surge protection [Class 11 SKA
Related optional items + FMFA Flexi Mounting Kit for Floor, Wall and
Pole (4701494)
EMHA Flexi 3) Mouting Cover (470316A)
EMHH Flexi 3U High Mouting Cover
(4731874)
FMHA Flexi Side Covers (4715244)
FPKA Flexi Pole Mounting Kit (30-120 mm)
(a71649)
FPKC Flexi Pole Mounting Kit (60-300 mm)
(4728214)
ASAA AirScale 2 MDR26-open EAC cable
5m (474288)
FIRC RET cable assembly 1 m (4750564)
FIRD RET cable assembly 2 m (4750574)
FIRE RET cable assembly § m (4750584)
FIRE RET cable assembly 10 m
(4750594)
Dimensions and weightNokia AirScale Macro FDD-LTE Radios Nokia AirScale Radio Description
Table 15 AREA dimensions and weight
Property vaue ‘Dimensions orientation
Height 118 mm (4.65 in.)
Depth [402 mm (15.831)
wath [441 mm (1736) ht
Weraht <25 49 (65 1216) wa fon
Environmental specifications
Table 16 AREA environmental specifications
Property value
Maximum operational outdoor temperature n_[55°C (131°F)
the shade)
Maximum operational outdoor temperature in [55°C (131°F)
the sun)
‘Maximum indoor temperature asc (11°F)
‘Minimum operational temperature -a0°c (40°F)
LTE4208 feature interdependencies
‘The LTE4208: Nokia AirScale RFM 6TER 83 480W (AREA) feature is impacted by the
following features:
+ LTET12: Cell Bandwicth - 20 MHZ
Needs to be enabled to use LTE 20 MHz carriers.
+ LTET13: Cell Bandwicth - 15 MHZ
Needs to be enabled to use LTE 15 MHz carriers.
+ LTE114: Cell Bandwidth - 10 MHz
Needs to be enabled to use LTE 10 MHz carriers.
+ LTET15: Cell Bandwidth - 5 MH2
Needs to be enabled to use LTE 5 MHz carriers.
+ LTET16: Cell Bandwidth - 3 MH2
Neads to be enabled to use LTE 3 MHz carriers.
+ LTEII7: Cell Bandwiath - 1.4 Mhz
Needs to be enabled to use LTE 1.4 MHe carriers,
+ With LTE614: Distributed Site,
AREA can be used in distributed sites with up to 23 km fiber length to the system
module.
+ LTE1103: Load based Power Saving for multi-layer networks
Needs to be enabled to use Load based Power Saving for multi-layer networks.
+ LTE1203: Load based Power Saving with Tx path switching off
Needs to be enabled to use Load based Power Saving with Tx path switching off
+ LTE2428: Nokia CPRI in FDD-LTE
Provides support for CPRI interfaNokia AirSeale Radio Description Nokia AirScale Macro FDD-LTE Radios
+ LTE2508: BTS Embedded Power Meter for Energy Efficiency Monitoring
Needs to be enabled to use BTS Embedded Power Meter for Energy Efficiency
Monitoring,
+ LTE2541; Nokia CPRI RRH/RFM chaining
Provides support for chaining,
+ LTE2553: OBSAI chaining to 9.8G CPRI link
AREA supports chaining of legacy OBSA radio units with Nokia CPRI radio
modules.
+ LTE3036: Micro DTX extension
Needs to be enabled to use Micro DTX extension
Warnings, cautions or notes related to the product
Z\ WARNING! Risk of electric shock.
Before turning RF power on, RF ports have to be terminated by nominal 50 0 load (for
‘example, feeder with antenna). However, if these conditions are not met, the plastic
caps that are delivered within the unused RF ports should remain in place. The plastic
caps isolate RF port from the environment, and thus provide electric shock security in
case RF power is accidentally on
Note: The minimum start-up voltage is -40.5 V DC. if the input voltage is below/beyond
the extended limits, the unit might shut down,