Beruflich Dokumente
Kultur Dokumente
Ameejee Chambers Campbell Street Near City Courts Off. M.A. Jinnah Rd
Karachi-74200
Tel 021-32625492 (5 Lines) Fax 021-32627817 Email chint@avs.com.pk
Sr. Description
1250 A *
for motorized 500 ~ 1250A T7S 1250 M ELECTRONIC 100% 215,000
1600 A *
for motorized 640 ~ 1600A T7S 1600 M ELECTRONIC 100% 290,000
1250 A *
for motorized 500 ~ 1250A T7S 1250M ELECTRONIC 100% 305,000
1600 A *
for motorized 640 ~ 1600A T7S 1600M ELECTRONIC 100% 335,000
* Spring Charging Motor can be installed in T7H1250M and T7H1600M on request.
PRICE LIST 2015
MADE IN ITLAY
3 POLE ADJUSTABLE
MADE IN ITLAY
Rated Service Voltage (Ue) 690V
Rated insulation voltage (Ui) 1000V
Rated impulse withstand voltage (Uimp) 12KV
Frequency 50-60Hz
Isolation behavior IEC 60947-2
Operation Temperature -25C……+70C
PROTECTIONS
L: Against over load.
S: Against short-circuit with delay trip
I: Against short-circuit with instantaneous trip
G: Against earth fault (on request)
UNIT PRICE
ACCESSORY DESCRIPTION
PKR
Under Voltage Release YU 240…250V AC/DC 30,000
Made in FRANCE
Ith
OPERATIONAL
AUXILIARY CAPACITY THERMAL UNIT PRICE
MODEL AMPERE
CONTACTS KW/HP AMPERE PKR
AC-3
AC-1
Made in FRANCE
AF9-40-00-13 4 25 8,000
AF16-40-00-13 9 30 8,000
AF26-40-00-13 11 45 11,000
AUXILIARY CONTACTS:
1 NO CA4-10 800
Front AF9----------AF38
1 NC CA4-01 800
1 NO CA5-10 800
Front A9------------A110
1 NC CA5-01 800
THERMAL OVER
Thermal Over Load Relays
The thermal overload relays are three pole relays with bimetal tripping elements. The
motor current flows through the bimetal tripping elements and heats them directly and
indirectly. In case of an overload (over current), the bimetal elements bent as a result of
the heating. This leads to a release of the relay and a change of the contacts switching
position (95-96 / 97-98).
–– Manual or automatic reset selectable
–– Phase loss sensitive acc. to IEC/EN 60947-4-1
–– TEST and STOP function – Trip indication on the front
–– Temperature compensation
–– Suitable for three- and single-phase applications
For direct coupling to AF09 ... AF38 3-pole contactors
UNIT
MODEL AMPERE RANGE PRICE
PKR
TF42-3.1 2.30 ... 3.10A 4,800
TF42-4.2 3.10 ... 4.20A 4,800
TF42-7.6 5.70 ... 7.60A 4,800
TF42-10 7.60 ... 10.0A 4,800
TF42-13 10.0 ... 13.0A 4,800
TF42-16 13.0 ... 16.0A 5,500
TF42-24 20.0 ... 24.0A 5,500
TF42-29 24.0 ... 29.0A 7,200
TF42-35 29.0 ... 35.0A 7,200
Mounting Kits
DB 42 TF 42 3,600
DB 80 TA 42 DU , TA 75 DU , TA 80 DU 4,100
2 POLE
1A~6A 3,400
10A~25A SH 202 2,500
2 Pole / 6KA
32A~40A 2,700
50A, 63A S 202 5,200
80A, 100A S 282 9,000
3 POLE
1A~6A 5,800
SH 203
10A~25A 3,700
3 Pole / 6KA
32A~40A 4,300
50A, 63A S 203 7,600
80A, 100A S 283 13,000
4 POLE
1A ~ 6A 10,500
SH 204
10A ~ 25A 9,000
4 Pole / 6KA
32A , 40A 10,000
50A, 63A S 204 18,600
80A, 100A S 284 20,000
PRICE LIST 2015
10 KA
According to IEC / EN 60898 / 60947-2
MADE IN GERMANY
2 POLE
1A ~ 6A 4,300
10A~25A 3,700
S 202
32A~40A 2 Pole / 10KA 4,200
50A, 63A 5,200
80A, 100A S 282 9,000
3 POLE
1A ~ 6A 6,000
10A~25A 5,000
S 203
32A~40A 3 Pole / 10KA 6,000
50A, 63A 7,500
80A, 100A S 283 13,000
4 POLE
1A ~ 6A 15,500
10A, 25A 12,500
S 204
32A, 40A 4 Pole / 10KA 14,500
50A, 63A 18,500
80A, 100A S 284 20,000
PRICE LIST 2015
MADE IN ITALY
MODEL POLE AMPERE CURRENT UNIT PRICE
SENSIVITY PKR