CLINICAL OUTPUT

HIGH FREQUENCY
RADIOGRAPHY & FLUOROSCOPY X-RAY SYSTEMS
50 kW, 65 kW, 80 kW, 100 kW

SALIENT FEATURES
Cost effective for all Radiographic applications (Hospitals, Medical Clinics, Chiropractic and Veterinary applications)
Field upgradable for your Future Imaging requirements.
Small, Compact & Light Weight.
Anatomical Programs available in many languages that are easily edited by the Operator Membrane Control Console.
Technique Selection :
1. kV with AEC
2. kV / mAs
3. kV / mA / Time
4. Patient / Body Part Thickness
(Membrane Control Console)
Low kV ripple - maximizes image quality by providing constant potential performance.
Automatic Tube Calibration
Service Software allows fast and easy set up as well as system diagnostics for off-site analysis
Collimator Power Supply

ROOM Dimensions as per AERB Guidelines - L 4.5 x B 4.0 x H 2.75 meters.


Single Leaf Door All wall of the Examination Room
lined with 2.0 mm lead. are 23 cm (9”) thick made of bricks.
GENUINE X-RAY & RADIOLOGICAL
X- Ray Examination Room
EQUIPMENTS PVT. LTD.
REVOLUTION IN RADIOLOGY
Plot No. 3, Radhe Industrial Estate, Block No. 497 (P),
Tajpur Road, Sarkhej - Bavla Road, Changodar, Ta. Sanand,
Ahmedabad - 382 213. Gujarat, India
MPB With Lead Glass
viewing Window of 2.0
Phone : +91 - 2717 - 298934
mm Lead equivalence E-mail : genuinexray@rediffmail.com
Table Centre info@genuinexray.com
Examination
Table Website : www. genuinexray.com
400 cm

X-Ray
Tube Head
Chest
Spot
Film Stand
CONTROL PANEL
Device Autho. Dealer :
Control
Unit

Tube Column
Stand
Certified & Approved by :
Unit AERB APPROVED
Electronics Column Center IS:7620

450 cm PART-1
CM/L - 3950571

All Machine Design / Technical Specifica ons shown in catalogue are subject to change without any prior no ce as standard procedure and constant improvement.
GOVERNMENT OF INDIA
REVOLUTION IN RADIOLOGY
HIGH FREQUENCY RADIOGRAPHY & FLUOROSCOPY X-RAY SYSTEMS TECHNICAL SPECIFICATION
GXL-HF 50 / GXL-HF 65 / GXL-HF 80 / GXL-HF 100 GENERAL SPECIFICATION 50 kW 65 kW 80 kW 100 kW
Generator Type High Frequency Output (Maximum 400 kHz)
TECHNOLOGY Rotor Supply Low Speed Starter (Op onal Dual Speed Starter)
HF Generator Series offers advanced high quality Radiographic capabilities with unmatched performance Input Phase / Voltage 3Ф / 400 - 480 VAC
and reliability resulting in the lowest cost of ownership over the product lifetime. This Generator is suitable for Film and CR - Power De-Ra ng <360 VAC Line De-Ra ng Required
Based Radiographic systems and features leading edge micro-processor based controls to minimize patient doze and Compa ble X-Ray Tubes >300 tube models
maximize image quality while demonstrating excellent reproducibility with user-friendly operator controls.
Anatomical Programs (APR) 1024 / 20,000 + techniques
Image Receptors Up to 6
LED MONITOR
Technique Selec on kV / AEC, kV / mAs, kV / mA / ms or kV / cm thickness (requires standard console)
Communica on Ports USB, CAN, Ethernet, RS485, RS232, RS422
Auxiliary Collimator Power Supply Standard Feature
GenWare Service So ware WEB - based diagnos c and technical support
RADIOGRAPHY 50 kW 65 kW 80 kW 100 kW
kVp Range 40 - 150 kV in 1 kV increments
kVp Accuracy ±2% for 90 - 110 kV; ±(5% + 1kV) for 40 - 150 kV
High Voltage Ripple <1kV @ 110 kV with 21 m (70 ) cables
Rise Time (10% - 90%) <0.75 ms (0.5 ms typical)
mA Range / Steps (1 mA / 0.1 mA 10 - 630 mA / 10 - 800 mA /
10 - 1000 mA / R’10 or R’20
Steps op onal) R’10 or R’20 R’10 or R’20
mA Accuracy ±(5% + 1 mA) measured a er 5 ms for exposures > 5 ms ±20% for exposures < 5 ms or ≤ 0.5 mAs
Exposure Timer Range 1 - 6300 ms in 1 ms increments (up to 99 s op onal - consult factory)
Exposure Timer Accuracy
(measured at 75% points of kV waveform) ±(2% +0.5 ms) for 5 - 6300 ms ± (10% + 1 ms) for < 5 ms or < 0.5 mAs
mAs Range (non-AEC) / Steps 0.1 - 1000 mAs / R’10
mAs Accuracy ±(10% + 0.2 mAs)
FLUOROSCOPY 50 kW 65 kW 80 kW 100 kW
kVp Range 40 - 125 kV in 1 kV steps
kVp Accuracy ±2% for 90 - 110 kV; ±(5% + 1kV) for 40 - 125 kV
High Voltage Ripple <1kV @ 110 kV & 5 mA with 21 m (70 ) cables
mA Range / Steps 0.5 - 20 mA in 0.1 mA steps
mA Accuracy ±(5% + 1 mA) ; ±20% for exposures < 6.7 mA
RADIOGRAPHY & FLUOROSCOPY X-RAY SYSTEMS

POSITIONS

H.V. Cable

X - Ray Tube

-15 Degree 45 Degree 90 Degree

All R & F Systems come with Floor to Ceiling Column Tube Stand fully counter balanced.
Control Unit Control Panel Vertical Bucky
Optional Ceiling Free Column Tube Stand available on demand.
X- RAY GENERATOR OPTIONAL