Beruflich Dokumente
Kultur Dokumente
.0 4.0
11
11.0 40°
4.0
4.0 4.5 12° 4.5
4.0 mm Tricut® Straight 4.0 mm RAD® 12 Curved 4.0 mm RAD® 40 Curved Irrigation Tubing
Rotatable Blade with Rotatable Blade with Rotatable Blade with for Blades and Burs
Automated EM Tracking Automated EM Tracking Automated EM Tracking 1895522
1884080EM 1884012EM 1884006EM • For use with IPC® blades and burs
· 13.0 cm long with straight shaft · 11.0 cm long with curved shaft · 11.0 cm long with curved shaft • 5 each
· Rotates through 360° · Straightshot® M4 rotates blade · Straightshot M4 rotates blade
· Offset cutting surface cuts in tip 360° without shaft rotation tip 360° without shaft rotation
3 planes · Offset cutting surface cuts · Offset cutting surface cuts
· Application: ethmoidectomy, in 3 planes in 3 planes
sphenoid sinus surgery · Application: uncinectomy, · Application: uncinectomy,
· Operating speed: 5,000 rpm, oscillate ethmoidectomy ethmoidectomy
· 1 each, irrigation tubing separate · Operating speed: 5,000 rpm, oscillate · Operating speed: 5,000 rpm, oscillate
· 1 each, irrigation tubing separate · 1 each, irrigation tubing separate
2
Automated EM Tracking Blades
First and Only Factory-Calibrated Blades for Navigation
4.3
• Better engagement of the ethmoid 2.0 1.3 * Boone JL, Feldt BA, McMains KC, Weitzel EK. Improved
function of prototype 4.3-mm Medtronic Quadcut
bone microdebrider blade over standard 4.0-mm Medtronic
• Improved precision 0.0 Clogs Weight MRR Cut Score Tricut microdebrider blade. Int Forum Allergy Rhinol,
2011; 1:198-200.
· Operating speed: 5,000 rpm, oscillate
· 1 each with irrigation tubing Data collected from 4.3 mm Quadcut Blade 4
Straight Sinus Blades
M4-Rotatable
TRICUT® BLADES
LOREM IPSUM SERRATED BLADES
LOREM IPSUM SILVER BULLET®
LOREM IPSUM TURBINATE
LOREM IPSUM
4.0 mm Tricut® Blade 4.0 mm Serrated Blade 4.0 mm Silver Bullet® 2.9 mm Inferior
1884004HR 1884002HRE Blade Turbinate Blade
· 11.0 cm long with straight shaft · 11.0 cm with straight shaft 1884005HRE 1882940HR
· Rotates through 360° · Rotates through 360° · 11.0 cm long with straight shaft · 11.0 cm long
· Offset cutting surface cuts in · Application: ethmoidectomy · Rotates through 360° · Rotates through 360°
3 planes · Operating speed: 5,000 rpm, · Application: ethmoidectomy · Straight shaft with elevator
· Application: ethmoidectomy oscillate · Operating speed: 5,000 rpm, · Application: submucosal resection
· Operating speed: 5,000 rpm, · 1 each with irrigation tubing oscillate of inferior turbinate
oscillate · 1 each with irrigation tubing · Operating speed:
· 5 each with irrigation tubing · Developed in conjunction with 3,000 rpm, oscillate
Rodney Lusk, MD · 5 each with irrigation tubing
4.0 mm Tricut® Blade 3.5
· Developed in conjunction with
1884080HR 3.5 mm Serrated Blade Laurence O’Halloran, MD
· 13.0 cm long with straight shaft 1883502HRE 2.9
· Rotates through 360°
· 11.0 cm long with straight shaft
· Offset cutting surface cuts in
· Rotates through 360°
2.9 mm Silver Bullet® 2.0
3 planes
· Application: ethmoidectomy Blade
· Application: ethmoidectomy,
1882905HRE 2.0 mm Inferior
· Operating speed: 5,000 rpm,
sphenoid sinus surgery
oscillate Turbinate Blade
· Operating speed: 5,000 rpm, · 11.0 cm long with straight shaft
oscillate · 1 each with irrigation tubing · Rotates through 360° 1882040HR
· 5 each with irrigation tubing · Application: choanal atresia · 11.0 cm long
· Operating speed: 5,000 rpm, · Rotates through 360°
oscillate · Straight shaft with elevator
3.5 2.9
· 1 each with irrigation tubing · Application: submucosal resection
2.9 mm Serrated Blade of inferior turbinate
3.5 mm Tricut® Blade · Developed in conjunction with
Rodney Lusk, MD · Operating speed:
1883504HR 1882902HRE 3,000 rpm oscillate
· 11.0 cm long with straight shaft · 11.0 cm long with straight shaft · 5 each with irrigation tubing
· Rotates through 360° · Rotates through 360° · Developed in conjunction with
· Offset cutting surface cuts in · Application: pediatric sinus Laurence O’Halloran, MD
3 planes surgery
· Application: ethmoidectomy · Operating speed: 5,000 rpm,
· Operating speed: 5,000 rpm, oscil- oscillate
late · 1 each with irrigation tubing
· 5 each with irrigation tubing
2.9
5
Straight Sinus Blades
Non-Rotatable
TRICUT® BLADES SERRATED BLADES SILVER BULLET® BLADES INFERIOR TURBINATE
4.0 mm Tricut® Blade 4.0 mm Serrated Blade 4.0 mm Silver Bullet® 2.9 mm Inferior
1884004 1884002 Blade Turbinate Blade
· 11.0 cm long with straight shaft · 11.0 cm long with straight shaft 1884005 1882940
· Offset cutting surface cuts in · Application: ethmoidectomy · 11.0 cm long with straight shaft · 11.0 cm long
3 planes · Operating speed: 5,000 rpm, · Application: ethmoidectomy · Straight shaft with elevator
· Application: ethmoidectomy oscillate · Operating speed: 5,000 rpm, · Application: submucosal resection
·O perating speed: 5,000 rpm, · 5 each with irrigation tubing oscillate of inferior turbinate
oscillate · 5 each with irrigation tubing · Operating speed:
· 5 each with irrigation tubing 60-3,000 rpm, oscillate
· Developed in conjunction with
Rodney Lusk, MD · 5 each with irrigation tubing
3.5 · Developed in conjunction with
Laurence O’Halloran, MD
3.5 3.5 mm Serrated Blade
1883502 2.9
3.5 mm Tricut® Blade
· 11.0 cm long with straight shaft
1883504 · Application: ethmoidectomy
2.9 mm Silver Bullet® 2.0
6
Powered Inferior Turbinoplasty
Long-Term Results with One Treatment
8
• VAS scores dropped 82%, on average,
and were maintained for 3 years The underlying turbinate bone is not removed and the
7
• Straightshot M4, 2.9 mm IT Blade overlying mucosa is also preserved. This technique reduces
6 the size of the inferior turbinate with no damage to the
SYMPTOMS
• 60 patients
5
functional mucosal tissue, such as blanching or crusting.
4.0
4.0
11.0
.0
11
.0
18
11.0 40°
4.0
4.5 12° 4.5
90°
4.0 mm RAD® 12 Blade 4.0 mm RAD® 40 Blade 60°
1884012HR 1884006HR
· 11.0 cm long with curved shaft · 11.0 cm long with curved shaft 4.5 4.0
4.0
1883512HRE
3.5 mm RAD® 40 Blade
.0
2.9 mm Skimmer®
Angle-Tip Blade
1882979HRE
· 13.0 cm long double-curved blade
Speeds are suggested
· Application: rpm
pituitary (revolutions
tumor
per minute),
resection operated in oscillation
mode for blades and (forward) mode
· Operating speed: 60-500 rpm
for burs.
· Low-profile distal bend: 15°
Measurements are listed in millimeters
· 1 each with irrigation tubing
unless otherwise specified.
8
Curved Sinus Blades
Key-Rotatable*
LOREM12IPSUM
RAD® BLADE LOREM40IPSUM
RAD® BLADE LOREM60IPSUM
RAD® BLADE IRRIGATION
LOREM IPSUMTUBING
3.5
.0
18
.0 3.5
11
60°
11.0
3.5 40°
3.5 mm RAD® 12 Blade 3.5 mm RAD® 40 Blade 3.5 mm RAD® 60 Blade Irrigation Tubing
1883514RT 1883507RT 1883516RT for Blades and Burs
· 11.0 cm long with curved shaft · 11.0 cm long with curved shaft · 11.0 cm long with curved shaft 1895522
· Key rotates blade tip 360° without · Key rotates blade tip 360° without · Key rotates blade tip 360° without • For use with IPC® blades and burs
shaft rotation shaft rotation shaft rotation • 5 each
· Offset cutting surface cuts · Offset cutting surface cuts · Offset cutting surface cuts
in 3 planes in 3 planes in 3 planes
· Application: uncinectomy, · Application: uncinectomy, · Application: frontal sinus surgery
ethmoidectomy ethmoidectomy · Operating speed: 5,000 rpm,
·O perating speed: 3,000 rpm, · Operating speed: 5,000 rpm, oscillate
oscillate oscillate · 3 each, irrigation tubing separate
· 3 each, irrigation tubing separate · 3 each, irrigation tubing separate
9
Curved Sinus Blades
Non-Rotatable
LOREM12IPSUM
RAD® BLADE RAD® 40IPSUM
LOREM BLADE LOREM60IPSUM
RAD® BLADE RAD®
LOREM60IPSUM
BLADE
.0
18
.0
11
.0
18
60°
60°
11.0 40°
4.0 mm RAD® 12 Blade 4.0 mm RAD® 40 Blade 4.0 mm RAD® 60 Blade 2.9 mm RAD® 60 Blade
1884012 1884006 1884016 1882916
· 11.0 cm long with curved shaft · 11.0 cm long with curved shaft · 11.0 cm long with curved shaft · 11.0 cm long with curved shaft
· Offset cutting surface cuts · Offset cutting surface cuts · Offset cutting surface cuts · Offset cutting surface cuts
in 3 planes in 3 planes in 3 planes in 3 planes
· Application: uncinectomy, · Application: uncinectomy, · Application: frontal sinus surgery · Same inner lumen as wider
ethmoidectomy ethmoidectomy 3.5 mm blades
· Operating speed: 5,000 rpm,
·O perating speed: 5,000 rpm, · Operating speed: 5,000 rpm, oscillate · Application: frontal sinus surgery
oscillate oscillate
· 5 each, irrigation tubing separate · Operating speed: 1,500 rpm,
· 5 each, irrigation tubing separate · 5 each, irrigation tubing separate oscillate
· 3 each, irrigation tubing separate
4.0 mm RAD® 12 4.0 mm RAD® 40
Microscopy Blade
.0
Microscopy Blade
18
.0
11
· Application: uncinectomy, · Application: frontal sinus surgery 1883516
ethmoidectomy · Operating speed: 3,000 rpm, · 11.0 cm long with curved shaft
· Operating speed: 3,000 rpm, oscillate
· Offset cutting surface cuts
oscillate · 3 each, irrigation tubing separate in 3 planes
· 5 each, irrigation tubing separate · Application: frontal sinus surgery
.0 · Operating speed: 5,000 rpm,
11
oscillate
11.0
· 3 each, irrigation tubing separate 120°
40°
3.5 12° · Developed in conjunction with
3.5
William Bolger, MD
3.5 mm RAD® 12 Blade 4.0
10
Straight Sinus Burs
LOREMBUR
OVAL IPSUM ROUND BURS
LOREM IPSUM ROUTER BUR
LOREM IPSUM SINUS BUR
LOREM SETS
IPSUM
3.2 mm Oval Bur, 4.5 mm Round Bur, 4.5 mm Aggressive Mini-Trephination Set
High-Speed High-Speed Router Bur, High-Speed The complete set includes:
1883264HS 1884560HS 1884562HS · 1882900, 2.0 mm Drill
· 12.5 cm long with straight shaft · 12.5 cm long with straight shaft · 12.5 cm long with straight shaft · 1892001, Drill Guide
· Cannulated suction bur tip · Cannulated suction bur tip · Cannulated suction bur tip · 1892002, Guide Pin
· Application: sinus drilling · Application: sphenoid drilling · Application: sinus drilling · 1892003, Irrigation Cannula
· Operating speed: · Operating speed: · Operating speed: · 3717005, Instrument Tray
up to 12,000 rpm (forward) up to 12,000 rpm (forward) up to 12,000 rpm (forward) (not shown)
· 3 each, irrigation tubing separate · 3 each, irrigation tubing separate · 3 each, irrigation tubing separate · Irrigation tubing separate
· Developed in conjunction with
Barry Schaitkin, MD
3.2 DRILL
11
Selecting the Best Bur for the Job
Modified Lothrop Procedure
12
Papilloma Surgical Technique
Using Angled Skimmer® Blades for Papilloma Excision
Surgical Technique
The ability to successfully excise papillomas while
avoiding collateral epithelial damage to the vocal
fold serves as a model to the surgical management
of papilloma. The recurrent nature of papilloma
with resultant numerous surgeries often leads
to progressive scarring and poor voice outcomes
02
that may be prevented by the ability to avoid injury
to normal tissues with the microdebrider.
Even for bulky disease associated with airway
obstruction, the Skimmer blade rapidly removes
papilloma in a controlled fashion (Figure 02). In
the setting of acute distress, a single controlled pass
can rapidly relieve airway obstruction and ensure
that the child has a secure airway. Subsequently,
a complete excision can be completed in the manner 03
described above (Figure 03).
The development of longer Tricut® blades, coupled with
the ability to rotate the blade housing, allows access
to the distal airway down to the mainstem bronchi for
papilloma removal (Figure 04). A Tricut blade is safe
for use in the distal airway as the tracheal and bronchial
mucosa is less susceptible to injury than the vocal fold
epithelium. In patients with tracheostomies, a useful
approach is to pass the blade through the stoma while 04
directly visualizing the blade with a transoral endoscope.
Caution: Careful attention to the transition from
papilloma to vocal fold epithelium is requisite.
Particular concern is at the region of the anterior
commissure where consideration of a staged
resection is prudent. Bleeding is generally minimal and
self-limited. If visualization becomes compromised,
a pledget soaked with a vasoconstrictive agent invariably
controls bleeding and allows the surgery to proceed.
13
Curved Sinus Burs
Anterior Skull Base
LOREM
ASB CUTIPSUM
TING BUR LOREM
ASB DIAMOND
IPSUM BURS LOREM
ASB DIAMOND
IPSUM BURS SKIMMER® BLADE
LOREM IPSUM
3.2
.0
25
15° 6.0
15°
2.9 15°
4.0 mm Anterior Skull 5.0 mm Anterior Skull 3.2 mm Anterior Skull 2.9 mm Skimmer®
Base Cutting Bur,* 15° Base Diamond Bur,* 15° Base Diamond Bur,* 40° Angle-Tip Blade
1884075HSE 1885076HSE 1883277HSE 1882979HRE
· 15.0 cm long · 15.0 cm long · 15.0 cm long · 13.0 cm long double-curved blade
· Application: Removal of bone in · Application: Removal of bone in · Application: Removal of bone in · Application: pituitary tumor
and around sphenoid, sella, clivus, and around sphenoid, sella, clivus, and around sphenoid, sella, clivus, resection
and pterygoid plate and pterygoid plate and pterygoid plate · Operating speed: 60-500 rpm
· Operating speed: · Operating speed: · Operating speed: · Low-profile distal bend: 15°
up to 12,000 rpm (forward) up to 12,000 rpm (forward) up to 12,000 rpm (forward)
· 1 each with irrigation tubing
· 1 each, irrigation tubing separate · 1 each, irrigation tubing separate · 1 each, irrigation tubing separate
· Developed in conjunction · Developed in conjunction · Developed in conjunction
with PJ Wormald, MD, and Aldo with PJ Wormald, MD, and Aldo with PJ Wormald, MD, and Aldo
Stamm, MD Stamm, MD Stamm, MD 5.0
25.0 3.2
15°
14
Curved Sinus Burs
(continued)
TAPERED DIAMOND BURS ROUND DIAMOND BUR DCR BURS RAD® BURS
3.0
.0
25
25.0 5.0 25.0 4.0
15.0
4.0 40°
15° 15°
15°
4.0 mm Choanal Atresia 5.0 mm Curved Round 4.0 mm Curved DCR Bur, 3.0 mm RAD® Frontal
Bur, High-Speed Diamond Bur, High-Speed High-Speed Finesse Bur, High-Speed
1883673HS 1885061HS 1884068HS 1883070HS
· 13.0 cm long with curved shaft · 12.5 cm long with curved shaft · 11.0 cm long with curved shaft · 13.0 cm long with curved shaft
· Cannulated suction bur tip · Cannulated suction bur tip · Application: endoscopic drilling · 8 flutes
· Application: removal of vomer · Application: trans-sphenoidal of lacrimal bone · Cannulated suction bur tip
· Operating speed: surgery · Operating speed: · Application: frontal sinus drilling
up to 12,000 rpm (forward) · Operating speed: up to 12,000 rpm (forward) · Operating speed:
· 3 each, irrigation tubing separate up to 12,000 rpm (forward) · 3 each, irrigation tubing separate up to 12,000 rpm (forward)
· Developed in conjunction with · 3 each, irrigation tubing separate · Developed in conjunction with · 3 each, irrigation tubing separate
Gary Josephson, MD · Developed in conjunction with Michael Mercandetti, MD · Developed in conjunction with
David Kennedy, MD Donald Leopold, MD
4.0
3.6
16.0 2.5
0
15.
20°
SEPTOPLASTY BUR
0
70°
35.
2.5 mm Curved Diamond
DCR Bur, High-Speed 55°
15
Airway Blades
M4-Rotatable
SKIMMER® BLADES SKIMMER® BLADES TRICUT® BLADES TRICUT® BLADES
11.0 11.0
6.0 6.0
2.9 15° 2.9 15° 4.0 15° 4.0 15°
2.9 mm Skimmer® 2.9 mm Skimmer® 4.0 mm Tricut® Angle-Tip 4.0 mm Tricut® Angle-Tip
Angle-Tip Blade Angle-Tip Blade Laryngeal Blade Tracheal Blade
1882979HRE 1882924HRE 1884030HRE 1884033HRE
· 13.0 cm long double-curved blade · 27.0 cm long double-curved blade · 22.0 cm long double-curved blade · 37.0 cm long double-curved blade
· Application: papilloma and · Application: papilloma removal, · Angled tip allows better visibility · Angled tip allows better visibility
tumor removal, laryngomalacia, laryngomalacia, and with endoscopy with endoscopy
and pediatric trans-sphenoidal hypophysectomy · Application: tumor debulking and · Application: debulking tracheal
· Operating speed: 60-500 rpm · Operating speed: 60-500 rpm granulation tissue removal papilloma and lesions, tumor
· Low-profile distal bend: 15° · Low-profile distal bend: 15° · Operating speed: 500-1,200 rpm debulking, and granulation tissue
· 1 each with irrigation tubing · 1 each with irrigation tubing · 1 each with irrigation tubing removal
· Developed in conjunction · Operating speed: 500-1,200 rpm
2.9 mm Skimmer® with William Lunn, MD, and · 1 each with irrigation tubing
Angle-Tip Blade Armin Ernst, MD · Developed in conjunction
with William Lunn, MD, and
1882925HRE 4.0 mm Tricut® Angle-Tip Armin Ernst, MD
· 18.0 cm long double-curved blade Subglottic Blade
· Application: papilloma removal, 4.0 mm Tricut® Angle-Tip
1884031HRE
laryngomalacia, and Bronchial Blade
trans-sphenoidal hypophysectomy · 27.0 cm long double-curved blade
1884035HRE
· Operating speed: 60-500 rpm · Angled tip allows better visibility
· Low-profile distal bend: 15° with endoscopy · 45.0 cm long double-curved blade
· 1 each with irrigation tubing · Application: tracheal stenosis, · Rotating angled tip offers access
tumor debulking, and granulation to lateral, medial, and posterior
tissue removal bronchial lesions through a rigid
2.9 mm Skimmer® bronchoscope
· Operating speed: 500-1,200 rpm
Angle-Tip Blade · Application: debulking bronchial
· 1 each with irrigation tubing
1882923HRE · Developed in conjunction
papilloma and lesions, tumor
debulking, and granulation tissue
· 22.0 cm long double-curved blade with William Lunn, MD, and removal
· Application: papilloma removal, Armin Ernst, MD
· Operating speed: 500-1,200 rpm
laryngomalacia, and
trans-sphenoidal hypophysectomy · 1 each with irrigation tubing
· Operating speed: 60-500 rpm · Developed in conjunction
with William Lunn, MD, and
· Low-profile distal bend: 15° Armin Ernst, MD
· 1 each with irrigation tubing
13 cm long
SKIMMER
18 cm long
22 cm long
27 cm long
22 cm long
TRICUT
27 cm long
16
Airway Blades
Non-Rotatable
SKIMMER® BLADES SKIMMER® BLADES SKIMMER® BLADES TRICUT® BLADES
11.0
6.0 6.0 11.0
2.9 mm Skimmer® 3.5 mm Skimmer® 4.0 mm Skimmer® Angle- 4.0 mm Tricut® Angle-Tip
Angle-Tip Blade Angle-Tip Blade Tip Laryngeal Blade Laryngeal Blade
1882925 1883525 1884023 1884030
· 18.0 cm long double-curved blade · 18.0 cm long double-curved blade · 22.5 cm long double-curved blade · 22.5 cm long double-curved blade
· Inner suction path is the same · Application: recurrent respiratory · Application: recurrent respiratory · Application: tumor debulking
as larger curved blade papilloma (RRP) removal and papilloma (RRP) removal and · Operating speed: 1,500 rpm
· Application: recurrent respiratory trans-sphenoidal hypophysectomy trans-sphenoidal hypophysectomy · 3 each with irrigation tubing
papilloma (RRP) removal and · Operating speed: 60-500 rpm · Operating speed: 60-500 rpm · Developed in conjunction with
trans-sphenoidal hypophysectomy · Low-profile distal bend: 15° · Low-profile distal bend: 15° Paul Flint, MD, and John Little, MD
· Operating speed: 60-500 rpm · 3 each with irrigation tubing · 3 each with irrigation tubing
· Low-profile distal bend: 15° · Developed in conjunction with
4.0 mm Tricut® Angle-Tip
· 3 each with irrigation tubing 3.5 mm Skimmer® Angle- Charles Myer, III, MD; Paul Wilging, Subglottic Blade
· Developed in conjunction Tip Laryngeal Blade MD; Brian Wiatrak, MD; Paul Flint, 1884031
with Craig Derkay, MD, and MD; David Parsons, MD; and John
David Darrow, MD 1883523 Little, MD · 27.5 cm long double-curved blade
· 22.5 cm long double-curved blade · Application: tracheal stenosis
2.9 mm Skimmer® · Application: recurrent respiratory 4.0 mm Skimmer® Angle- · Operating speed: 1,500 rpm
Tip Subglottic Blade · 3 each with irrigation tubing
Angle-Tip Blade papilloma (RRP) removal and
trans-sphenoidal hypophysectomy 1884024
1882923
· Operating speed: 60-500 rpm · 27.5 cm long double-curved blade
· 22.5 cm long double-curved blade
· Low-profile distal bend: 15° · Application: recurrent respiratory 4.0
· Inner suction path is the same
as larger curved blade · 3 each with irrigation tubing papilloma (RRP) removal and
· Developed in conjunction with trans-sphenoidal hypophysectomy
4.0 mm Tricut® Straight-
· Application: recurrent respiratory
papilloma (RRP) removal and Charles Myer, III, MD; Paul Wilging, · Operating speed: 60-500 rpm
Tip Laryngeal Blade
MD; Brian Wiatrak, MD; Paul Flint, 1884020
trans-sphenoidal hypophysectomy · Low-profile distal bend: 15°
MD; David Parsons, MD; and John
· Operating speed: 60-500 rpm Little, MD · 3 each with irrigation tubing · 22.5 cm long
· Low-profile distal bend: 15° · Developed in conjunction with · Straight tip with curve
3.5 mm Skimmer® Angle- Charles Myer, III, MD; Paul Wilging, at handpiece
· 3 each with irrigation tubing
MD; Brian Wiatrak, MD; Paul Flint, · Application: debulking of RRP
· Developed in conjunction Tip Subglottic Blade lesions
with Craig Derkay, MD, and MD; David Parsons, MD; and John
1883524 Little, MD · Operating speed: 1,200 rpm
David Darrow, MD
· 27.5 cm long double-curved blade · 3 each with irrigation tubing
· Application: recurrent respiratory · Developed in conjunction with
papilloma (RRP) removal and Paul Flint, MD, and John Little, MD
trans-sphenoidal hypophysectomy
· Operating speed: 60-500 rpm
· Low-profile distal bend: 15°
· 3 each with irrigation tubing
· Developed in conjunction with
Charles Myer, III, MD; Paul Wilging,
MD; Brian Wiatrak, MD; Paul Flint,
MD; David Parsons, MD; and John
Little, MD
37 cm long
45 cm long
17
Airway Blades
Non-Rotatable (continued)
SERRATED BLADES SERRATED BLADES TRACHEAL BLADE
11.0
11.0
18
Tonsillectomy and Adenoidectomy Blades
RADENOID® BLADES
LOREM IPSUM RADENOID® BLADES
LOREM IPSUM TONSILLECTOMY
LOREM IPSUM BLADE LOREM
T&A IPSUM
BLADE SET
.0
25
40°
.0
18
4.0
45°
40°
4.5 mm RADenoid® 4.0 mm RADenoid® 4.0 mm Tonsillectomy Powered T&A Blade Set
Adult Blade Blade Blade 1884008TA
1884507 1884008 1884013 · 13.0 cm
· 13.0 cm long with curved 45° blade · 11.0 cm long with curved 40° blade · 11.0 cm · Removable inner cutting tube
· Application: adenoidectomy · Application: adenoidectomy · 12° blade · 40° outer blade designed for
· Allows better access into the choana · Operating speed: 1,500 rpm · Application: intracapsular powered adenoidectomy
· Operating speed: 1,500 rpm · 5 each, irrigation tubing separate tonsillectomy · 12° outer blade designed for
· 5 each, irrigation tubing separate · Operating speed: 1,500 rpm powered intracapsular tonsillectomy
· Designed in conjunction with
· Designed in conjunction with Max April, MD, and J. Lindhe · 5 each, irrigation tubing separate · Operating speed: 1,500 rpm
Max April, MD, and J. Lindhe Guarisco, MD · 5 each, irrigation tubing separate
Guarisco, MD · Developed in conjunction with
Peter J. Koltai, MD
The IPC® Powered T&A Blade Set for the PITA™ Technique
Clinical studies show that PITA™ surgery (Powered Intracapsular Tonsillectomy and Adenoidectomy)
offers significant advantages to most patients.6-22 With interchangeable 12° and 40° outer cutting
tubes, you can remove adenoids and tonsils in the traditional order.
19
Aesthetic Blades and Burs
FEATHERTOUCH®
LOREM IPSUM RASPS FEATHERTOUCH®
LOREM IPSUM RASPS OTHER
LOREM IPSUM OTHER
LOREM IPSUM
8.0 8.0
19.0 19.0 13.0
4.0 9.0
20
References
1. Nathan RA. The burden of allergic rhinitis. Presented at the Mid-Conference Symposium of the Eastern Allergy Conference, Naples, FL. May 2006.
2. Liu C-M, Tan C-D, Lee F-P, Lin K-N, Huang H-M. Microdebrider-assisted versus radiofrequency-assisted inferior turbinoplasty.
Laryngoscope 2009; 119:414-418.
3. Chen Y-L, Liu C-M, Huang H-M. Comparison of microdebrider-assisted inferior turbinoplasty and submucosal resection for children with
hypertrophic inferior turbinates. Intl J Ped Otorhinolaryn. 2007; 71:921-927.
4. Chen Y-L, Tan C-T, Huang H-M. Long-term efficacy of microdebrider-assisted inferior turbinoplasty with lateralization for hypertrophic inferior
turbinates in patients with perennial allergic rhinitis. Laryngoscope 2008; 118:1270-1274.
5. Lin H-C, Lin P-W, Friedman M, Chang H-W, Su Y-Y, Chen Y-J, Pulver T. Long-term results of radiofrequency turbinoplasty for allergic rhinitis refractory
to medical therapy. Arch Otolaryngol Head Neck Surg. 2010; 136(9):892-895.
6. Gallagher TQ, Wilcox L, McGuire E, Derkay CS. Analyzing factors associated with major complications after adenotonsillectomy in 4776 patients:
Comparing three tonsillectomy techniques. Otolaryngol Head Neck Surg 2010; 142:886-892.
7. Vaughan AH, Derkay CS. Microdebrider intracapsular tonsillectomy. ORL J Otorhinolaryngol Relat Spec 2007;69:358-63.
8. Schmidt R, Herzog A, Cook S, O’Reilly R, Deutsch E, Reilly J. Complications of tonsillectomy. A comparison of techniques.
Arch Otolaryngol Head Neck Surg 2007;133:925-8.
9. Derkay CS, Darrow DH, Welch C, Sinacori J. Post-tonsillectomy morbidity and quality of life in pediatric patients with obstructive tonsils and
adenoid: microdebrider vs electrocautery. Otolaryngol Head Neck Surg 2006; Jan; 134(1):114-20.
10. Sobol SE, Wetmore RF, Marsh RR, Stow J, Jacobs IN. Post-operative recovery after microdebrider intracapsular or monopolar electrocautery
tonsillectomy: a prospective, randomized, single-blinded study. Arch Otolaryngol Head Neck Surg 2006;132:270-4.
11. Lister MT, Cunningham MJ, Benjamin B, Williams M, Tirrell A, Schaumberg DA, Hartnick CJ. Microdebrider tonsillectomy vs electrosurgical
tonsillectomy: a randomized, double-blind, paired control study of postoperative pain. Arch Otolaryngol Head Neck Surg 2006;132:599-694.
12. Koltai PJ, Solares CA, Mascha EJ, Xu M. Intracapsular partial tonsillectomy for tonsillar hypertrophy in children. Laryngoscope 2002;112:17-19.
13. Koltai PJ, Solares A, Koempel JA, Hirose K, Abelson TI, Krakovitz PR, Chan J, Xu M, Mascha EJ. Intracapsular tonsillar reduction (partial tonsillectomy):
reviving a historical procedure for obstructive disordered breathing in children. Otolaryngol Head Neck Surg 2003;129:532-8.
14. Sorin A, Bent JP, April MM, Ward RF. Complications of microdebrider-assisted powered intracapsular tonsillectomy and adenoidectomy.
Laryngoscope 2004;114:297-300.
15. Bhayani R, Bent JP, April MM, Ward RF. Comparison of microdebrider assisted partial tonsillectomy with electrocautery tonsillectomy: retrospective
pilot study. Presented at: Seventeenth Annual Meeting of the American Society of Pediatric Otolaryngology; May 12-14, 2002; Boca Raton, FL.
16. Cook SP, O’Reilly RC, Bernat R, Otto T, Lawless ST, Reilly JS. Outcome and satisfaction of intracapsular tonsillectomy in children: one-year follow-up.
Presented at: Nineteenth Annual Meeting of the American Society of Pediatric Otolaryngology; May 2-4, 2004; Phoenix, AZ.
17. Bent JP, April MM, Ward RF, Sorin A, Reilly B, Weiss G. Ambulatory powered intracapsular tonsillectomy and adenoidectomy in children younger
than 3 years. Arch Otolaryngol Head Neck Surg 2004;130:1197-1200.
18. Darrow DH, Weiss DD. Management of sleep-related breathing disorders in children. Oper Tech Otolaryngol Head Neck Surg 2002;13:111-8.
19. Koltai PJ. Capsule sparing in tonsil surgery: the value of intracapsular tonsillectomy [letter]. Arch Otolaryngol Head Neck Surg 2003;129:1357.
20. Lister MT, Cunningham MJ, Benjamin B, Williams M, Tirrell A, Schaumberg DA, Hartnick CJ. Microdebrider partial tonsillectomy vs. electrosurgical
tonsillectomy: a randomized, double-blind, paired-control study of postoperative pain. Presented at: Twentieth Annual Meeting of the American
Society of Pediatric Otolaryngology; May 27-30, 2005; Las Vegas, NV.
21. Mixson C, Austin MB, Weinberger P. Comparison of microdebrider subcapsular tonsillectomy to Harmonic scalpel and electrocautery total
tonsillectomy. Presented at: Twentieth Annual Meeting of the American Society of Pediatric Otolaryngology; May 27-30, 2005; Las Vegas, NV.
22. Shnayder Y, April M, Willging J. Power-Assisted Adenoidectomy in the Treatment of Chronic Otitis Media with Effusion. Poster Presentation at:
American Society of Pediatric Otolaryngology, May 4, 2003, Nashville, TN.
21
Integrated Power Console (IPC®) System
· The innovative IPC® system is the only ENT powered surgery system with the widest range
of application-specific handpieces and accessories
· With fingertip control on the Straightshot® M4, the blade tip rotates 360° independently of the shaft
* Select a Power
Cord and a
System Manual
This literature is intended for the exclusive use of physicians. Rx only USA. © 2013, Medtronic, Inc.
official policy or position of the Department of the Navy, the Department of Defense, nor the U.S.
Fusion®, IntelliFlow®, Quadcut®, Endo-Scrub®, FeatherTouch®, HydroBrader®, IPC®, Micro-Planer®,
RAD®, RADenoid®, RhinoBur®, Silver Bullet®, Skimmer®, Straightshot®, Tardy MicroBur® and Tricut®
The views expressed in this document are those of the authors and do not necessarily reflect the