Sie sind auf Seite 1von 1

§ 1926.704 29 CFR Ch.

XVII (7–1–11 Edition)

strength to support its weight and su- § 1926.705 Requirements for lift-slab
perimposed loads. construction operations.
(2) Reshoring shall not be removed (a) Lift-slab operations shall be de-
until the concrete being supported has signed and planned by a registered pro-
attained adequate strength to support fessional engineer who has experience
its weight and all loads in place upon in lift-slab construction. Such plans
it. and designs shall be implemented by
the employer and shall include detailed
APPENDIX TO § 1926.703(a)(1)
instructions and sketches indicating
GENERAL REQUIREMENTS FOR FORMWORK the prescribed method of erection.
These plans and designs shall also in-
(This appendix is non-mandatory.) clude provisions for ensuring lateral
This appendix serves as a non-mandatory stability of the building/structure dur-
guideline to assist employers in complying ing construction.
with the formwork requirements in (b) Jacks/lifting units shall be
§ 1926.703(a)(1). Formwork which has been de- marked to indicate their rated capac-
signed, fabricated, erected, braced, supported ity as established by the manufacturer.
and maintained in accordance with Sections (c) Jacks/lifting units shall not be
6 and 7 of the American National Standard loaded beyond their rated capacity as
for Construction and Demolition Oper- established by the manufacturer.
ations—Concrete and Masonry Work, ANSI (d) Jacking equipment shall be capa-
A10.9–1983, shall be deemed to be in compli-
ance with the provision of § 1926.703(a)(1).
ble of supporting at least two and one-
half times the load being lifted during
[53 FR 22643, June 16, 1988, as amended at 61 jacking operations and the equipment
FR 5510, Feb. 13, 1996] shall not be overloaded. For the pur-
pose of this provision, jacking equip-
§ 1926.704 Requirements for precast ment includes any load bearing compo-
concrete.
nent which is used to carry out the lift-
(a) Precast concrete wall units, ing operation(s). Such equipment in-
structural framing, and tilt-up wall cludes, but is not limited, to the fol-
panels shall be adequately supported to lowing: threaded rods, lifting attach-
prevent overturning and to prevent col- ments, lifting nuts, hook-up collars, T-
lapse until permanent connections are caps, shearheads, columns, and foot-
completed. ings.
(b) Lifting inserts which are embed- (e) Jacks/lifting units shall be de-
ded or otherwise attached to tilt-up signed and installed so that they will
precast concrete members shall be ca- neither lift nor continue to lift when
pable of supporting at least two times they are loaded in excess of their rated
the maximum intended load applied or capacity.
transmitted to them. (f) Jacks/lifting units shall have a
(c) Lifting inserts which are embed- safety device installed which will cause
ded or otherwise attached to precast the jacks/lifting units to support the
concrete members, other than the tilt- load in any position in the event any
up members, shall be capable of sup- jack/lifting unit malfunctions or loses
porting at least four times the max- its lifting ability.
imum intended load applied or trans- (g) Jacking operations shall be syn-
mitted to them. chronized in such a manner to ensure
(d) Lifting hardware shall be capable even and uniform lifting of the slab.
of supporting at least five times the During lifting, all points at which the
slab is supported shall be kept within 1/
maximum intended load applied or
2 inch of that needed to maintain the
transmitted to the lifting hardware.
slab in a level position.
(e) No employee shall be permitted (h) If leveling is automatically con-
under precast concrete members being trolled, a device shall be installed that
lifted or tilted into position except will stop the operation when the 1⁄2inch
those employees required for the erec- tolerance set forth in paragraph (g) of
tion of those members. this section is exceeded or where there
[53 FR 22643, June 16, 1988, as amended at 54 is a malfunction in the jacking (lifting)
FR 41088, Oct. 5, 1989] system.

410

VerDate Mar<15>2010 15:51 Sep 16, 2011 Jkt 223116 PO 00000 Frm 00420 Fmt 8010 Sfmt 8002 Q:\29\29V8.TXT ofr150 PsN: PC150

Das könnte Ihnen auch gefallen