JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
JPX321series exchange side terminal modules are used to terminate PSTN intra-
office cable and connect jumper. It can be also used to test and open circuit, as well
as deploying DSL service and separate DSL signals from POTS signals at the office
end.
The DSL service can be deployed in expansion mode and new-building mode.
PSTN cable
User module terminal
line module 1
Existing equipment
Broadband
SPL
equipment at
the office end
DSLAM data cable
Exchange
side
External line jumper terminal
module 2
Figure 1.1
2
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
SPL
terminal equipment at
terminal the office end
PSTN cable
User module
line Exchange
side
terminal
module 1
DSLAM jumper
Figure 1.2
Table 2.1
SN Model Description
Table 2.2
SN Model Description
1 AS-7K DSL voice splitter –in an expansion office—applicable to back plug-in module
2 AS-5K DSL voice splitter –in an expansion office—applicable to front plug-in module
3 AS-6X DSL voice splitter –in a new-built office—applicable to front plug-in module
3
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
Table 2.3
SN Model Description
Table 2.4
SN Model Description
1 JPX321-BM2-128A 128-loop vertically installed module- 8 contact elements –front plug-in voice splitter
128 -loop horizontally installed module- 8 contact elements –front plug-in voice
2 JPX321-BM2-128B
splitter
Figure 1.3
The module is applicable to the mounting situation with the rows spacing 250 mm or
more, where the JPX321-BM-128A is a vertically installed series and the JPX321-BM-
128B is a horizontally one.
4
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
Table 3.1
Capacity
Application Description
(loop)
Used in deploying POTS service 256 Connect 4 group (8 pcs) cables in each loop.
Used in deploying DSL service in Connect 4 group(8 pcs) cables in each loop;
128
high-density mode Voice splitter is not plugged in.
128 pcs voice splitters are needed in full-configuration; the
Used in deploying DSL service
front plug-in voice splitter AS-5K is needed in expansion mode
with the front plug- in voice splitter
128 and front plug-in AS-6X voice splitter is needed in new-
(in new-building and expansion
building mode;
mode)
Connect 3 group (6 pcs) cables in each loop.
Table 3.2
5
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
Figure 1.4
1.3 Accessories
The accessories include IDC tool, testing plug, switching plug and open-circuit plug,
and etc.
Figure 1.5
6
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
Table 5.1
SN Model Description
Figure 1.6
The testing cord is 5 meters long, with 8 alligator clips corresponding to 8 contact
elements in each loop.
Table 6.1
SN Model Description
Figure 1.7
7
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
Note:
It has a similar appearance with AS-5K/AS-6X, but they are in different colors.
The module bar of JPX321 series exchange side terminal module is installed in
clasping mode and can be removed if required. Figure 2-1 shows a JPX321-BM2-
128B module bar installed on the support.
8
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
Figure 1.8
Note:
When installing a module bar , one side of it should be put in position appropriately first and then the
other side; as for removing , press one side of the module bar first till the clip withdrawing from the
installation hole, then the bar can be removed . The module bar may be damaged if overexerted.
Install the support onto the mounting pole in MDF with M6 bolts.
Mount module bars one by one on the support. The few bars which is colored
differently from the others should be installed on the left ( or the top) so that
different module bars can be distinguished.
Mount the ID mark.
The cabling management for PSTN cable and external line jumper is shown in Figure
2-4.
9
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
Figure 1.9
Note:
The external line jumper should be traced via the guide holes, and the others should be traced through
the space among the module bars.
The clamping relationship of POTS cable and the external line jumper is shown in
Figure 2-5.
4 2
1
10
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
Figure 1.10
II. Deploying DSL service with front plug-in voice splitter in expansion mode
The cabling management for DSLAM data cable , external line jumper and PSTN
jumper is shown in Figure 2-8.
Figure 1.11
Note:
The PSTN jumper should be traced via the guide holes, where as the others should be traced through
the space among the module bars.
The clamping relationship of DSLAM data cable , external line jumper and PSTN
jumper is shown in Figure 2-9.
11
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 2 Installation and Cabling
3 2
1
2
3
1. DSLAM data cable (triangle mark●) 2. External line jumper (square mark■)
3. PSTN jumper(round mark▲)
Figure 1.12
12
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 3 Usage
The AS-5K/6X voice splitter is plugged in the front of the JPX321-BM-128A/B series
modules or JPX321-BM-64B series modules. Anti-reverse plugging structure is set.
Plug the voice splitter into the slot of the 8-loop module bar. Make sure it is in
position, as shown in Figure 3-2 (a JPX321-BM-128A/B module bar is taken as an
example).
13
JPX321 Series Exchange Side Terminal Module and Voice Splitter
User Manual Chapter 3 Usage
1
2
Anti-reverse
plugging structure
14