Sie sind auf Seite 1von 4

Design of two way slab

slab type continuous Fck


effective short span (Lx) 4.455 m fy
Long span (Ly) 6.145 m eff cover
Ly/Lx 1.379349046 OK Two way bar
concrete u
αx- 0.047 Refer code table 16
αx+ 0.098
αy- 0.047
αy+ 0.0515

depth calculation depth 139.21875 mm (required) 111.375


overall depth 175 mm (provided)
effective depth 155 mm

Load calculation self weight 4.375 kN/m2


floor finish 1 kN/m2
partition wall load 0 kN/m2
live load 2 kN/m2
total design load 11.0625 kN/m2

Areas calculation Moments (kNm/m) Mu/bd2 Ast (mm2)bar dia (mm) spacing (re
Along short span bottom +ve 21.5166559781 0.895594 401.7965 8 125.0384
top -ve 10.3192125609 0.42952 188.1996 8 266.9507
Along long span bottom +ve 11.3072222742 0.470644 206.635 8 243.134
top -ve 10.3192125609 0.42952 188.1996 8 266.9507

Shear Check
Max shear force 24.64171875 kN
nominal shear stres 0.1589788306 N/mm2
concrete shear stre 0.34 N/mm2 (Refer code table 19)
k 1.5
slab shear strength 0.51 N/mm2
OK

Deflection Check

α 26
β 1 (Refer code 23.2)
γ 1.8
δ 1
λ 1
Lex/d 28.7419354839
αβγδλ 46.8
OK
25 N/mm2
415 N/mm2
20 mm
8 mm
25 kN/m3

> 0.12 %

spacing pr Ast,prov Pt,prov (%)Pt,lim


150 334.9333 0.19139 Not Ok
150 334.9333 0.19139 Not Ok
150 334.9333 0.19139 Not Ok
150 334.9333 0.19139 Not Ok

fs 288.7512
simple
continuous
cantilever

Das könnte Ihnen auch gefallen