Sie sind auf Seite 1von 20

Datasheet

ACUSON P300
Ultrasound System
Release 1.5

Inc.
www.siemens.com/ultrasound
www.medicaldevicedepot.com
1-877-646-3300
ACUSON P300 Ultrasound System

Table of Contents
INTRODUCTION................................................................4 Stress Echo Package.......................................................8
Complete patient care solution.......................................4 Quality Intima Media Thickness (QIMT)...........................9
Portability with ease.......................................................4 Archiving Capabilities.....................................................9
Support you can count on..............................................4 Connectivity..................................................................9
Image File Formats.........................................................9
EXTENDING TECHNOLOGIES.............................................4 Video I/O.......................................................................9
High frequency imaging.................................................4 Printing.......................................................................10
TEI.................................................................................4 Video Requirements.....................................................10
XView............................................................................4 Video Tape Recorder.....................................................10
MView...........................................................................5 DICOM Classes.............................................................10
TPView..........................................................................5 Software......................................................................10
VPan..............................................................................5 Safety Requirements . ..................................................10
System .......................................................................10
APPLICATION USAGE........................................................5 Cart.............................................................................10
Power Supply (mains)...................................................10
SYSTEM OVERVIEW..........................................................5
Battery .......................................................................11
Control Panel.................................................................5
Power Cables...............................................................11
Cart Design....................................................................5
Operating Environment................................................11
Monitor.........................................................................5
Storage Environment....................................................11
Operating Modes...........................................................6
Image Display Modes.....................................................6 MEASUREMENTS AND REPORTING.................................11
Image Formats...............................................................6
System Packages – Standard.........................................11
Modularity.....................................................................6
Transducer Formats........................................................6 System Packages – Optional.........................................11

Operating Console.........................................................7 General Imaging .........................................................12

Transmit........................................................................7 Vascular.......................................................................13

Receive..........................................................................7 Cardiology...................................................................14

RF Signal processing.......................................................7 OB/GYN.......................................................................14

2D.................................................................................7
TRANSDUCERS................................................................16
M-mode.........................................................................7
Convex Array Transducers ............................................17
Color.............................................................................7
Linear Array Transducers . ............................................17
Doppler PW....................................................................7
Phased Array Transducers ............................................18
Doppler CW...................................................................8
Specialty Transducers ..................................................18
Echo Process Controls.....................................................8
Non-imaging Pencil Transducers ..................................19
ECG...............................................................................8
Disposable Needle Guides by Protek .............................19
Compass M-mode (CMM) ..............................................8
Disposable Needle Guides by CIVCO .............................20
Tissue Velocity Mapping (TVM).......................................8

2
ACUSON P300 Ultrasound System

INTEGRATING THE HEALTHCARE ENTERPRISE (IHE)........20

STANDARDS COMPLIANCE..............................................21

CE DECLARATION...........................................................21

EU AUTHORIZED REPRESENTATIVE..................................21

3
ACUSON P300 Ultrasound System

ACUSON P300
Ultrasound System
INTRODUCTION EXTENDING TECHNOLOGIES
The ACUSON P300™ ultrasound system is a high- High frequency imaging
performance, compact, diagnostic ultrasound
• Up to 18.0 MHz bandwidth on linear transducers
system that provides many advanced technologies
to provide detailed and precise imaging,
standard in the mainframe, and a broad transducer
especially in superficial investigations such as
suite to support individual and diverse practices;
MSK application
from traditional applications to specialty markets.
The system is ergonomically designed for comfort and • Multiple transmission frequencies to scan deeper
is backed by the Siemens service team for peace of structures without changing transducers
mind. TEI

Complete patient care solution • Harmonic imaging: Dedicated hardware and


software processing of the harmonic signals
• Standard package includes advanced image
improve B-mode image quality, especially in
optimization functionalities to support traditional
technically difficult patients
and specialty applications needs
• Available on all imaging transducers
• Optimized for applications in musculoskeletal
(MSK), breast, small parts, cardiology, vascular, • Three selectable frequencies; General,
general imaging and OB/GYN Resolution, Penetration

• Advanced cardiovascular capabilities including • Available in combination with Color Doppler (C),
Tissue Velocity Mapping, Compass M-mode, M-mode, Power Doppler
Stress Echo, Quality Intima Media Thickness XView
• Wide selection of Linear, Convex, Phased,
• Speckle reduction: Elaborates pattern of single
Laparoscopic, Intraoperative and
frame at the pixel level, eliminating speckle and
Endocavity transducers
noise artifacts for contrast resolution,
Portability with ease dynamically enhancing tissue margins, improving
tissue conspicuity
• Sleek design, easy to move and maneuver with
convenient cable management system • Customizable presets (X Smooth, X Detail, X
Enhancement) enable real-time optimization of
• Integrated power supply
the image process algorithm
• Two transducer ports

Support you can count on


• Backed by Siemens service and support
• Access to the Siemens global network of
technical and application expertise to ensure
optimal system performance
• A standard 2-year factory warranty* and flexible * Including system parts and system specific transducers,
service options to meet your unique needs excluding specialty transducers and accessories.

4
ACUSON P300 Ultrasound System

MView SYSTEM OVERVIEW


• Spatial compounding: combined contributions of Control Panel
standard and steered ultrasound beams to
• Ergonomically designed and illuminated for ease
optimize image quality and improve detection of
of use
anatomical structures
• Full alphanumeric QWERTY keyboard
• Up to 15 angles of view within the same image
• Logically grouped controls
TPView • Customizable keys
• Trapezoid imaging: enlarged field of view on all • Dedicated technology buttons; 2D, M-mode,
linear transducers, allowing scanning of extended C, PW, CW
structures without losing resolution • Dedicated function keys; Start/End exam, Menu,
• Specially suited for breast, vascular, Probe/User preset selection, Archive review,
musculoskeletal, and thyroid applications Exam review, Mark, Report, Measurement,
Line/Update (split modes), Dual imaging, Image
VPan
store, Clip store, Options key (Annotations, ECG,
• Panoramic view: dedicated software merging VTR, Power and Edit ID), Auto/Gain, Action,
multiple B-mode images into one panned image Rec/Print, Depth/Zoom, 8 TGC
displayed on the screen in real-time; auto-fit of • Siemens Select key (S) managing operation-
composite, image zoom, merging level, frame dependent software keys and special functions
marker, colorize, and distance measurement on screen
• Extended field of view supports visualization of • Integrated speakers
the entire organ. Areas of interest such as muscu-
• Dedicated footswitch connector
loskeletal and lesions associated with abdominal,
breast and small parts can be more easily studied Cart Design
• Ergonomic and compact for easy maneuverability
APPLICATION USAGE
• Four transducer holders plus one Pencil
The ACUSON P300 ultrasound system is specifically transducer holder
designed for the following applications:
• One gel holder
• Abdominal (Adult, Pediatric, Neonatal) • ECG cable holders
• Adult Transcranial • Transducer and ECG cable management system
• Breast • Multi-directional wheels with braking mechanism
• Cardiac (Adult, Pediatric, Neonatal) and locking levers
• Emergency • Height-adjustable for maximum ergonomics
• General Imaging • On-board peripheral storage
• Gynecology • Foot rest for added comfort
• Intraoperative/Interventional • Rubber bumpers to prevent wall contact
• Musculoskeletal
Monitor
• OB/GYN
• 15” XVGA LCD monitor (1024x768 aspect ratio)
• Small Parts
• Backlight type: CCFL
• Vascular
• Contrast ratio: 800 (typical)
• Viewing angle: R/L 140° (typical), U/D 140°
(typical)
5
ACUSON P300 Ultrasound System

• Contrast digital adjustment Operating Modes


• Information displayed on monitor: • 2D (B-mode)
– Application • B-mode steering
– Selected preset • B-mode AutoAdjust
– On-line help for measurements • Colorize 2D, M-mode and PW/CW
– Date & time • PW/CW Doppler
– Type of transducer • Non-imaging CW
– Transducer orientation • PW/CW Doppler AutoAdjust
– Operating frequency range • C (Color Doppler)
– Acoustic power output • TEI (Harmonic Imaging)
– Gray map • TPView (Trapezoid Imaging)
– Dynamic range • VPan (Panoramic Imaging)
– Compression • Bidirectional Power Doppler
– Persistence
Image Display Modes
– Enhancement
– XView • 256 gray levels or B-color levels

– MView • 32 bits Color levels

– Depth • Orientation: Left/Right, Up/Down

– Focus • Real-time Triplex mode

– Doppler angle • 2D+2D (with or without C or PWR D)

– Color & Spectral Doppler filter • 2D+M-mode (update or Real-time Duplex)

– Sample volume size • 2D+C+M-mode (update)

– PRF • 2D+Doppler (update or Real-time Triplex)

– Gain • 2D+Color+Doppler

– 2D • 2D+PWR D

– C • 2D+PWR D+Doppler (update or Real-time Triplex)

– PW/CW frame rate • Colorize on all combinations

– Biopsy line Image Formats


– Patient data • Imaging: Full, Split, Multiple, Left/Right, Up/Down
– Hospital data and annotations • Tracing: Split, Dual (scroll by line)
– Body markers
Modularity
– Remote digital printing and storage status
– Remote DICOM printing and storage status • Software options
– Heartbeat • Application license
– Timer Transducer Formats
– Sweep time indication on trace
• Multi-frequency electronic: Convex array, Phased
– Icons on top right for XView array, Linear array, and Pencil CW
– AutoAdjust
– Icons on top right for MView
6
ACUSON P300 Ultrasound System

Operating Console • Acoustic frame rate: > 200 Hz (200 fps)*


• Digital modular platform – Max 411 Hz (411 fps)*
• Dynamic range: up to 210 dB * transducer and FOV dependent

• User presets (unlimited customizable) for every • Maps: up to 5 post processing gray maps, up to
transducer and application 7 color tint scales
• Processing channels: up to 4,160 channels • Zoom: variable magnification up to 4x (Real-time)
and up to 32x (Frozen)
• Dual processor
• XView processing (Speckle Reduction Algorithm)
Front End • PRF: up to 11 KHz
• Biopsy kits and display lines
Transmit
• Gain and TGC auto-adjustment
• Ultrasound beam generation pulses with:
– Delay: up to 13µs (step ≤ 12.5 ns) M-mode
– Focal points: up to 8 for every transducer • Sweep time: 2 – 16 sec (step 1s)
– Bipolar wave • PRF: 1 KHz
– Frequencies: from 1.0 MHz up to 18.0 MHz
Color
– Programmable number of cycles
• Frequencies: 2.0 – 8.0 MHz (2.0, 2.5, 2.9, 3.3,
– CW generation capability
5.0, 6.6, 8.0 MHz)
– Programmable aperture
• Sampling PRF: 0.3 – 11.1 KHz (transducer
Receive dependent)

• Digital beam former • Wall filters: 4 levels, depending on PRF

• Dynamic receive focusing • Data dynamic: 10 bit (+5 for intensity)


• Maps: up to 16
RF Signal processing
• Frame rate: up to 40 Hz
• Interpolated data RF lines generation capability • Frame interpolation
• Up to 2 digital chain beam for each channel • Interleave: up to 16 lines
• Imaging filters up to 128 taps digital • Samples: up to 512/lines
dynamic filter
• Packet size: 4 – 28
• Second Harmonic Imaging (TEI)
• Format: ROI with/without wider b/w
• Size: 15-85% of max b/w size
Back End
• Velocity range: up to ± 4.01 m/s
2D
• Steering (linear transducers): 3 steps (6°/12°/18°)
• Field of view: 30° – 90° on Phased array
Doppler PW
– Transducer dependent formats: Phased array,
Linear array (with steering), Convex array • Frequencies: 2.0 – 8.0 MHz (2.0, 2.5, 2.9, 3.3,
• Depth: 20 – 360 mm depending on transducer 5.0, 6.6, 8.0 MHz)

• Digital scan converter with bilinear interpolation • PRF: 1.3 – 22.2 KHz (transducer dependent)
process (640x480x8) • Multigate HPRF
• Acoustic lines: up to 512 • Wall filters: 50 – 1800 Hz (8 step)
• Data dynamic: 8 bit • Stereophonic audio
7
ACUSON P300 Ultrasound System

• Sweep Time: 2 – 16 sec (step 1s) • DC max: 300 mV


• Spectrum: FFT with 128 frequencies, interpolated • Leakage current: < 10 µA
up to 512 points (analysis time: ≤1 ms) • Time constant: 3.3 s ± 10%
• Sample Size: 1 – 24 mm • H.R. detection range: 40 – 240 bpm
• Velocity range: up to ± 4.81 m/s
Compass M-mode (CMM)
• Angle correction : ±75°
• Steering (linear transducers): 3 steps (6°/12°/18°) • Anatomical M-mode: Allows angle-free M-mode
measurements in real-time
• Doppler gain and scale auto-adjustment
• Displays up to two independent lines and two
• Real-time Automatic Doppler Measurements (in
separate M-mode scans in real-time
non-cardiac applications)
• Available on all probes
Doppler CW
Tissue Velocity Mapping (TVM)
• Frequencies: 2.0 – 5.0 MHz (2.0, 2.5, 3.3,
5.0 MHz) • Doppler tissue imaging: quantitative evaluation
of heart wall motion to measure velocity
• Wall filters: 50 – 1800 Hz (8 steps)
distribution of moving myocardial tissue
• Data dynamic: 8 bit
• TVM can operate in:
• Stereophonic audio
– 2D imaging - TVM
• Sweep Time: 2 – 16 sec (step 1s)
– M-mode - MTVM
• Spectrum: FFT with 128 frequencies, interpolated
– PW/Doppler - TV
up to 512 points (analysis time: ≤1 ms)
• Factory and user programmable presets for TVM
• Velocity range: up to ±6.42 m/s (@ 2.0 MHz)
• TVM calculation package provides guided velocity
• Angle correction: ± 75°
and acceleration measurements and includes a
Echo Process Controls measurement reporting package
• Requires the Cardiology package
• Power: up to 30 dB
• Available on the PA230E
• Imaging compression: 30 – 60 dB
• Doppler compression: 20 – 40 dB Stress Echo Package
• Imaging gain: 60 dB (TGC + general) Stress echo provides tools for ECG-triggered
• C gain: 30 dB acquisition, including programmable protocols and
• Doppler PW gain: 25 dB multi-format reviewing capabilities during various
• Doppler CW gain: 25 dB stages of a stress echo examination for accurate
monitoring of cardiovascular pathologies.
• Pre-processing: 16 dynamic shapes in
imaging modality • Ability to customize studies with up to 8 stages,
• Post-processing: 5 steps imaging and Doppler 5 views per stage

• Persistence: 8 steps, depending on frame rate • Full screen or resize and move ROI (region of
interest) for acquisition
ECG • Prospective continuous capture (defined in
• Type CF applied part protocol) or Retrospective labeled capture
• Input impedance: > 10 MOhm (DC) • Customized standard and pharmacological stress
protocols
• CMMR: > 90 dB (50 Hz)
• Immediate review of acquired loops

8
ACUSON P300 Ultrasound System

• Able to pause and resume during acquisition • User-selectable filter for database searches
• Wall Motion Scoring: up to 17 segments, with • Still image and loop storage in DICOM formats
graphical display • Real-time still frames and video clips
• Full reporting capability • Stored data thumbnails always displayed on the
• Optional feature on the system side of the screen
• Measurement and Annotation on stored images
Quality Intima Media Thickness (QIMT)
• IHE Compliant
Radio frequency-based technology for semi-
automated measurement of intima media thickness Connectivity
in real-time for highly accurate and repeatable
• I/Os connectors
results.
– Serial RS-232
• Real-time measurements and feedback
– LAN RJ45
• Visual feedback for measuring quality,
– 3 USB (for image transfer)
reproducibility, and ECG sampling from artery
• Dedicated connectors
wall movements
– Audio input/output (stereo)
• Measurement based on 6 heartbeats
– ECG input
• ECG tracing not required
– Double foot switch
• Accurate up to 21 micrometers
– External trigger input
• Manheim IMT Consensus compliant
• Complete reporting with normal values (Howard) Image File Formats
and immediate visualization of the measurements
• Standard output: BMP, JPG, PNG, AVI
acquired in previous examination (vascular trend)
• Native and DICOM
• Optional feature on the system
• Clips characteristics
Archiving Capabilities • AVI Codec: Microsoft® MPEG4-V2 (highly
• Still image (full resolution) compressed), MS-WMV9 (improved compatibility)
and MS-Video1 (low level compression)
• Clip (full resolution)
• Still frames: lossy compressed (about 70% of
• Graphic overlays
quality) and not compressed : BMP, JPEG, PNG
• Reports
• Graphic overlays
• Offline capability
• Reports
• Compressed images and clips
• Cine Memory: 256 MB (store capacity is 400 Video I/O
frames) continuous loop with different modes • XVGA output (auxiliary monitor)
(single, dual, split), including Time/ECG triggered
• S-Video (S-VHS) input/output
loop and frame-by-frame feature
• C-Video (VHS) input
• PC: ≥ 512 MB local drive
• RGB (TV standard)
• Hard disk: ≥ 250 GB
• Video standard: PAL / NTSC (software controlled)
• DVD reader/writer
– DVD: write up to 8x; read up to 8x
– CD: write up to 24x; read up to 24x
• Internal patient database

9
ACUSON P300 Ultrasound System

Printing Software
• Ink jet color or Laser B/W & Color USB Printer • Operating system: WIN XP Embedded
(1,2,4 and 6 images printed out on A4 format- • Multi-language operation menus (English, Italian,
8.5x11 inch) French, German, Spanish)
• Thermal B/W and Color Video Printers • Reports, calculations and measurements
• Thermal Digital B/W and Color Printers (application dependent)
• Biometry (On/Off-line report)
Video Requirements
• DVD upgrading capability
RGB Printer
Safety Requirements
• Input: RGB SYNC
• RGB (analog): 0,7 Vp-p, 75 ohm • EN 60601-1
• SINC: 5 Vp-p • EN 60601-1-1
• Connectors: Standard BNC • EN 60601-1-2
• Safety standard: IEC 60950 or EN60601-1 • EN 60601-1-4
• EN 60601-2-37
B/W Printer
• ENISO 10993-1
• Input: Video Composite (1 Vp-p, 75 ohm)
• EN 61157
• Connectors: Standard BNC
• AIUM / NEMA UD-2 / UD-3 – FDA 510(k) Track 3
• Safety standard: IEC 60950 or EN60601-1
Dimensions and Weights
Video Tape Recorder
I/O video: YC System
• Y: 1 Vp-p, 75 ohm Dimensions
• C: 0,3 Vp-p Color burst, 75 ohm • Closed: 35 cm (L) x 18 cm (H) x 49 cm (D)
• Tape format: VHS, S-VHS • In working position: 35 cm (L) x 43 cm (H) x
• Audio traces: 2 49 cm (D)
• Video Conn: 4 pin connector
Weight
• Audio Conn: Jack
• 9 kg (w/o battery pack)
• SINC: 5 Vp-p
• Safety standard: IEC 60950 or EN60601-1 Cart

DICOM Classes • Dimensions: 51 cm (W) x 84-106.6 cm (H) x


65.4 (D) cm
• DICOM Media Storage
• Weight: 24 kg
• DICOM Store SCU
• DICOM Print Power Supply (mains)

• DICOM Modality Worklist (MWL) • Voltage operative range: 100 – 240 V


• DICOM Modality Performed Procedure Step (MPPS) • Working frequency range: 50 – 60 Hz
• DICOM Storage Commitment (SC) • Power consumption: ≤ 250 VA

10
ACUSON P300 Ultrasound System

Battery Storage Environment


• Two removable Li-ion batteries • Temperature: -20° – +60°C
• Operating time: 1 hour and 20 min • Humidity: 5 – 95% (not condensing)
• Recharging time: 100% = 3 hours and 30 min • Pressure: 700 – 1060 hPa
• After 300 cycles remains 80% of maximum
charge MEASUREMENTS AND REPORTING
• Nominal operating voltage is 14.4V System Packages – Standard
• Capacity: 6.6A • Abdomen
• Power: 95W • Breast
Power Cables • Pediatric
• Small Parts
CEE
• Thyroid
• Socket: 510 IEC 320/C13 type: 10A-250V
• Transcranial
• Plug: VII (7) VII type; 10A-250V
• MSK
• Conductors: 3
• Vascular
• Section: 1 mm2
• Standard biometry reports and user-customizable
• Length: 2.5 m
reports
CEI • All reports are automatically stored on the system
in the patient file
• Socket: 510 IEC 320/C13 type: 10A-250V
• Plug: I/3 CEI 23-16 type: 10A-250V System Packages – Optional
• Conductors: 3 • Cardiac
• Section: 1 mm2 • OB/GYN
• Length: 2.5 m • All reports are automatically stored on the system
NEMA in the patient file
• Archiving of structured reports requires the
• Socket type and amperage: 510 IEC 320/C13 type:
purchase of the DICOM module
13A-125V
• Refer to the operations manual for advanced
• Plug type: NEMA 5-15; 13A-125V
measurement and report detail
• Conductors: 3
• Section: AWG 16
• Length: 3 m

Operating Environment
• Temperature: 15° – 35°C
• Humidity: 15 – 95% (not condensing)
• Pressure: 700 – 1060 hPa
• Heat output: 853 BTU/hr

11
ACUSON P300 Ultrasound System

Generic Measurements M-mode

General Imaging Parameter Calculation Measure


The General Imaging license comes standard with the Distance Distance Distance
system and enables the abdominal, breast, thyroid,
Distance Distance Distance
small parts, musculoskeletal, and pediatric applications.
D-Ratio Distance ratio Two distances
B-mode
Time Time Time
Parameter Calculation Measure % Time Time ratio Two Times
Distance Distance Distance HR Heart rate Distances
D-Ratio Distance ratio Two distances Velocity Velocity Velocity
% Diam Diameter Two distances % Velocity Velocity ratio Two velocities
reduction
Vx-Length Length More distances Doppler
(rectilinear
approximation) Parameter Calculation Measure
Tr-Length Length (Profile) Distance Time Time Time
A-Ellipse Area (Ellipse) Distance, Area % Time Time ratio Two times
Vx-Area Area (rectilinear More distances Velocity Velocity Velocity
approximation)
% Velocity Velocity ratio Two velocities
Tr-Area Area (Profile) Profile
HR Heart rate Time
A-Ratio Areas ratio Two areas
(on a profile) FVI Vascular FVI Spectral
envelope
% Area Reduction area Two areas
(on a profile) PI Pulsatility index Spectral
envelope
EI-Volume Volume (Ellipse) Distance, Area
RI Resistive index Two velocities
Tri-Volume Volume (Profile) Profile, Distance
Tr-Flow Flow (Profile) Velocity, Profile
Bi-Volume Volume (Axes) Three distances
EI-Flow Flow (Ellipse) Velocity, Profile
D-flow Flow (Diameter) Velocity,
Distance

12
ACUSON P300 Ultrasound System

Vascular Doppler
The Vascular imaging license comes standard with Parameter Calculation Measure
the system.
Time Time Time
B-mode % Time Time ratio Two times
Parameter Calculation Measure Velocity Velocity Velocity
Distance Distance Distance % Velocity Velocity ratio Two velocities
D-Ratio Distance ratio Two distances HR Heart rate Time
% Diam Diameter Two distances FVI Vascular FVI Spectral
reduction envelope
Tr-Area Area (Profile) Profile PI Pulsatility index Spectral
envelope
A-Ratio Areas ratio Two areas (on a
profile) RI Resistive index Two velocities
% Area Area reduction Two areas (on a Tr-Flow Flow (Profile) Velocity, Profile
profile)
EI-Flow Flow (Ellipse) Velocity, Profile
Velocity Velocity Velocity
D-Flow Flow (Diameter) Velocity,
% Velocity Velocity ratio Two velocities Distance

M-mode

Parameter Calculation Measure


Distance Distance Distance
D-Ratio Distance ratio Two distances
Time Time Time
% Time Time ratio Two times
HR Heart rate Distances
Velocity Velocity Velocity
% Velocity Velocity ratio Two velocities
% Velocity Velocity ratio Two velocities

13
ACUSON P300 Ultrasound System

Cardiology OB/GYN
The Cardiology imaging license is an option The OB imaging license is an optional purchase.
purchase. Advanced measurements and reporting Advanced measurements and reporting can be found
can be found in the operations manual. in the operations manual.

B-mode B-mode

Parameter Calculation Measurement Parameter Calculation Measure


Distance Distance Distance Distance Distance Distance
Tr-Area Area (Profile) Profile D-Ratio Distance ratio Two distances
Tr-Volume Volume (Profile) Profile, Distance Vx-Length Length More distances
(approximately
E-Ratio Area ratio Two areas straight)
(ellipse based)
Tr-Length Length (Profile) Distance
M-mode A-Ellipse Area (Ellipse) Distance, Area
Parameter Calculation Measurement Vx-Area Area More distances
(approximately
Distance Distance Distance straight)
HR Heart rate Time Tr-Area Area (Profile) Profile
Velocity Velocity Velocity A-Ratio Areas ratio Two areas (on a
profile)
Doppler
EI-Volume Volume (Ellipse) Distance, Area
Parameter Calculation Measurement Tr-Volume Volume (Profile) Profile, Distance
Time Time Time Bi-Volume Volume (Axes) Three distances
Velocity Velocity Velocity E-Ratio Area ratio Two areas
HR Heart rate Time (ellipse based)

C-FVI FVI Spectral M-mode


envelope
Slope Slope Slope Parameter Calculation Measure

ME'P Peak velocity Velocity Distance Distance Distance


E' wave D-Ratio Distance ratio Two distances
MA'P Peak velocity Velocity Time Time Time
A' wave
% Time Time ratio Two times
E'/A' Peak velocity Velocity ratio
E' wave/Peak HR Heart rate Distance
velocity A' wave
Velocity Velocity Velocity
% Velocity Velocity ratio Two velocities

14
ACUSON P300 Ultrasound System

Doppler

Parameter Calculation Measure


Time Time Time
% Time Time ratio Two times
Velocity Velocity Velocity
% Velocity Velocity ratio Two velocities
HR Heart rate Time
C-FVI FVI Spectral
envelope
FVI Vascular VI Spectral
envelope
PI Pulsatility Spectral
index envelope
RI Resistive index Two velocities
Tr-Flow Flow (Profile) Velocity,
Profile
EI-Flow Flow (Ellipse) Velocity,
Profile
D-Flow Flow Velocity,
(diameter) Distance
D-Flow Flow Velocity,
(Diameter) Distance

15
ACUSON P300 Ultrasound System

TRANSDUCERS
The ACUSON P300 system supports the following transducers and applicable intended clinical uses:

ABD AC BRE CAR CP GYN MSK NC OB PED SP THY VAS

Curved Array

CA123         

CA431     

Linear Array

LA435          

LA522E          

LA523          

Phased Array

PA023E     

PA122E      

PA230E         

Specialty

EC1123  

IOE323          

LP323     

Doppler

2CW  

5CW 

ABD: Abdominal; AC: Adult Cephalic; BRE: Breast; CAR: Cardiac; CP: Cardiac Pediatric; GYN: Gynecologic;
MSK: Musculoskeletal conventional and superficial; NC: Neonatal; OB: Obstetric; PED: Pediatric;
SP: Small Parts; THY: Thyroid; VAS: Vascular.

16
ACUSON P300 Ultrasound System

Transducers Technical Specifications • B-mode, M-mode Selectable Frequencies: 5.0,


7.5, 10.0, 12.0 MHz
Convex Array Transducers
• TEI Frequencies: Penetration and Resolution
CA123
• C Doppler, PW Doppler Selectable Frequencies:
• Technology: Wideband Electronic Convex Array 3.3, 5.0 MHz
• Number of elements: 128 • Steered angle: 7 steps
• Depth: 0 – 140 mm • Biopsy: Multi angle reusable autoclave sterilized
• Footprint: 14 mm radius adaptor
• Field of view: 90° LA435
• Frequency Bandwidth: 3.0 – 9.0 MHz
• Technology: Wideband Electronic Linear Array
• B-mode, M-mode Selectable Frequencies: 5.0,
• Number of elements: 192
6.6, 8.0 MHz
• Depth: 0 – 90 mm
• TEI Frequencies: Resolution and Penetration
• Footprint: 40 mm x 5 mm
• C Doppler, PW Doppler Selectable Frequencies:
5.0, 6.6 MHz • Frequency Bandwidth: 6.0 – 18.0 MHz

• Biopsy: Disposable kit • B-mode, M-mode Selectable Frequencies: 10.0,


12.0, 15.0, 18.0 MHz
CA431 • TEI Frequencies: Penetration and Resolution
• Technology: Wideband Electronic Convex Array • C Doppler, PW Doppler Selectable Frequencies:
• Number of elements: 192 6.6, 8.0 MHz
• Depth: 0 – 360 mm • Steered angle: 7 steps
• Footprint: 40 mm radius • Biopsy: Multi-angle reusable autoclave
• Field of view: 30° – 85° sterilized adaptor

• Frequency Bandwidth: 1.0 – 8.0 MHz LA523


• B-mode, M-mode Selectable Frequencies: 2.5, • Technology: Wideband Electronic Linear Array
3.5, 5.0, 6.6 MHz
• Number of elements: 192
• TEI Frequencies: General, Penetration,
• Depth: 0 – 120 mm
and Resolution
• Footprint: 50 mm x 8 mm
• C Doppler, PW Doppler Selectable Frequencies:
2.5, 2.9 MHz • Frequency Bandwidth: 5.0 – 12.0 MHz

• Biopsy: Multi-angle reusable autoclave • B-mode, M-mode Selectable Frequencies:


sterilized adaptor 7.5, 10.0, 12.0 MHz
• TEI Frequencies: Penetration and Resolution
Linear Array Transducers
• C Doppler, PW Doppler Selectable Frequencies:
LA522E 5.0, 6.6 MHz
• Technology: Wideband Electronic Linear Array • Steered angle: 7 steps
• Number of elements: 192 • Biopsy: Multi-angle reusable autoclave sterilized
adaptor, disposable kit
• Depth: 0 – 120 mm
• Footprint: 50 mm x 8 mm
• Frequency Bandwidth: 3.0 – 12.0 MHz

17
ACUSON P300 Ultrasound System

Phased Array Transducers • Color Doppler, PW Doppler Selectable


Frequencies: 5.0 MHz
PA230E
• Biopsy: Not available
• Technology: Wideband Electronic Phased Array
• Number of elements: 128 Specialty Transducers
• Depth: 0 – 360 mm EC1123
• Footprint: 14 mm x 23 mm • Technology: Wideband Electronic end fire
• Field of view: 15° – 90° microConvex
• Frequency Bandwidth: 1 – 4 MHz • Number of elements: 192
• B-mode, M-mode Selectable Frequencies: 2.0, • Depth: 0 – 170 mm
2.5, 3.5 MHz • Footprint: 13 – 10 mm radius
• TEI Frequencies: General, Penetration, Resolution • Field of view: 30° – 195°
• Color Doppler, PW Doppler Selectable • Frequency Bandwidth: 3.0 – 9.0 MHz
Frequencies: 2.0, 2.5 MHz
• B-mode, M-mode Selectable Frequencies: 4.0,
• Biopsy: Not available 5.0, 6.6, 8.0 MHz
PA122E • TEI Frequencies: Resolution

• Technology: Wideband Electronic Phased Array • C Doppler, PW Doppler Selectable Frequencies:


5.0, 6.6 MHz
• Number of elements: 128
• Biopsy: Single and disposable use adaptor
• Depth: 0 – 270 mm
• Foot print: 10 mm x 16 mm IOE323
• Field of view: 15° – 90° • Application: Intraoperative
• Frequency Bandwidth: 3.0 – 8.0 MHz • Technology: Wideband Electronic Linear Array
• B-mode, M-mode Selectable Frequencies: 4.0, • Depth: 0 – 90 mm
5.0, 7.5 MHz • Footprint: 30 mm
• TEI Frequency: N/A • Frequency Bandwidth: 5.0 – 12.0 MHz
• C Doppler, PW Doppler Selectable Frequencies: • B-mode, M-mode Selectable Frequencies: 5.0,
3.3 – 5.0 MHz 7.5, 12.0 MHz
• Biopsy: Not available • TEI Frequency: N/A
PA023E • C Doppler, PW Doppler Selectable Frequencies:
5.0, 6.6 MHz
• Technology: Wideband Electronic Phased Array
• Biopsy: Multi-angle reusable autoclave sterilized
• Number of elements: 128
adaptor
• Depth: 0 – 270 mm
• Foot print: 6 mm x 13 mm
• Field of view: 15° – 90°
• Frequency Bandwidth: 4.0 – 11.0 MHz
• B-mode, M-mode Selectable Frequencies:
7.5, 10.0 MHz
• TEI Frequencies: N/A

18
ACUSON P300 Ultrasound System

LP323 Biopsy Kits


• Application: Laparoscopic The following kits are available:
• Technology: Wideband Electronic Linear Array
Biopsy adaptor Probe Kit contents
• Depth: 0 – 90 mm
ABS421 CA431 1 20° coupling,
• Frequency Bandwidth: 5.0 – 12.0 MHz
1 30° coupling+ 5
• B-mode, M-mode Selectable Frequencies: 5.0, needle guides
7.5, 12.0 MHz
ABS523 LA523 1 coupling (45° angle)
• TEI Frequency: N/A
LA522E + 5 needle guides
• C Doppler, PW Doppler Selectable Frequencies:
5.0, 6.6 MHz ABS424 LA435 1 coupling (45° angle)
+ 5 needle guides
• Articulation ± 90° up/down
• Articulation ± 90° right/left ABS15 IOE323 1 coupling (45° angle)
+ 5 needle guides
• Biopsy: Not available

Non-imaging Pencil Transducers Disposable Needle Guides by Protek1


All kits are provided with 12–23 gauge needle guides.
2 MHz CW Doppler
Each kit contains sterile transducer covers, sterile
• Number of elements: 2 needle guides, sterile gel and sterile elastic bands
• C Doppler, PW Doppler Frequencies: 2.0 MHz plus a non-sterile mounting bracket and a non-sterile
verification kit. The sterile needle guides are of
5 MHz CW Doppler different colors to match the needle to be used.
• Number of elements: 2 The needle guides are sterile, but they cannot be
• C Doppler, PW Doppler Frequencies: 5.0 MHz re-sterilized.

Probe Fixed Angle Manufacturer’s Kit P/N


CA123 15° 7356
20°
CA431 7352
30°
LA435 45° 7350
45°
LA522E
60° 7351
LA523
75°
EC1123 0° 6360

1
www.protekmedical.com
19
ACUSON P300 Ultrasound System

Disposable Needle Guides by CIVCO2 Free Insertion Angle Kits


Fixed Angle and Multi-Angle Kits The Infinity needle guide kits listed in the table below
allow the user to have a free insertion angle: this can
All kits are provided with 12–23 gauge needle guides.
be any angle within the range edged by the guide
Each kit contains sterile transducer covers, sterile
back wall, on one side, and by the transducer itself,
needle guides, sterile gel and sterile elastic bands
on the other side. The kit allows the user to keep the
plus a non-sterile mounting bracket and a non-sterile
needle on the same scanning plane of the transducer.
verification kit. The needle guides are sterile, but
they cannot be re-sterilized. All kits are provided with 14 and 18 gauge needle
guides. Each kit contains sterile transducer covers,
Manufacturer’s sterile needle guides, sterile gel and sterile elastic
Probe Fixed Angle Multi-Angle
Kit P/N bands plus a non-sterile mounting bracket and a non-
20° sterile verification kit. The needle guides are sterile
CA123 639-028 but cannot be re-sterilized.
35°
20° Probe Insertion Angle Range Manufacturer’s P/N
CA431 639-018
30° CA431 42° – 64° 639-014

50° LA435 42° – 80° 639-021

LA435 60° 639-023 LA522E


42° – 80° 639-016
70° LA523

40°
LA523 INTEGRATING THE HEALTHCARE
55° 639-022 ENTERPRISE (IHE)
LA522E
70° Having all relevant information at one’s fingertips is a
prerequisite for optimal and efficient patient care.
EC1123 3°, 8° 610-693
Seamless integration of the hospital’s IT and Imaging
EC1123 0° 639-012 Systems and their capabilities to exchange
information without restriction are key success
factors for facilitating daily work. This is why Siemens
has been instrumental in launching and advancing
the IHE (Integrating the Healthcare Enterprise)
Initiative. Our commitment and dedication enable us
to provide clinicians with the ACUSON P300 system
one of many innovative products embedded with the
building blocks necessary in supporting clinicians’
need for seamless health information exchange.
For more information on the ACUSON P300 system
and the Siemens commitment to the IHE initiative,
please visit www.siemens.com/IHE.

2
www.civcomedical.com
20

Das könnte Ihnen auch gefallen