CALCUALATE CAPACITY FOR CURING POOL

6th. November 2015


Quantity Quantity Quantity of Quantity day for
No Iterm Type of product Shift
of line Sam./1line sample for 1day curing

A B C D=A*B*C E F=D*E

1 Old workshop W500,W600,…,W940 2 6 2 24 28 672

2 New workshop Sleeper 1 6 2 12 28 336

3 Out side W400 1 6 2 12 28 336

4 Another produce in the future 336


Total samples 1 1680
Square meter/ 1samples 2 0.018
Square need for curing pool m2 3=1*2 30
We can curing sample with 2layer so square need for curing pool is 15m 2 + 5m2 serveve 20m2
- Calcualate capacity of curing pool with 2 work of shift/ 1day, all line production on day and every line curing 6 samples:
3 for 7days and 3 for 28days