CBA25UH
MERIT® Series
R-410A - Upflow / Horizontal - 60 Hz
Bulletin No. 210814
RESIDENTIAL August 2019
P R O D U C T S P E C I F I C AT I O N S Supersedes March 2019
CB A 25 UH - 030 - 230 - 10
Refrigerant Type
Voltage
A = Aluminum Coil/R-410A
230 = 208/230V-1 phase-60hz
Series
1. Quantum™ Coil E
2. Refrigerant Line Connections
3. Check and Expansion Valve
4. Blower Motor
5. Heavy Gauge Steel Cabinet
6. Anti-Microbial Dual Position Drain Pans
7. Air Filter B
8. Transformer and Blower Relay
9. Electric Heat (option)
F
D
H C G
CON T ENTS
CONTROLS Thermostat
• Thermostat is not furnished with unit
I Transformer and Blower Cooling Relay
• Lennox Price Book for selection
• 24 volt transformer and blower cooling relay furnished
as standard OPTIONAL ELECTRIC HEAT
• Factory installed in the unit control box
J • ETL listed
• Terminal strip furnished • Field install internal to unit cabinet
Optional Accessories • Available in several kW sizes
iComfort® M30 Smart Wi-Fi Thermostat • See Electric Heat tables
• Wi-Fi-enabled, electronic 7-day, universal, multi-stage, • Helix wound nichrome heating elements exposed
programmable, touchscreen thermostat directly in air stream resulting in instant heat transfer,
• 4 Heat/2 Cool low element temperatures and long service life
• Auto-changeover • Each element equipped with accurately located limit
control with fixed temperature off setting and automatic
• Dual-fuel control with reset
optional outdoor sensor
• Thermal sequencer relay brings elements on and off
• Controls dehumidification line, in sequence and equal increments, with time delay
during cooling mode and between each
humidification during
heating mode • Initiates and terminates blower operation
• Offers enhanced capabilities including humidification / • Heating control relay(s) furnished as standard
dehumidification / dewpoint measurement and control, • Factory assembled with controls installed and wired
Humiditrol® control, and equipment maintenance • Electric heat control wiring plugs into mating connector
reminders on air handler unit
• Easy to read 4.3 in. color touchscreen (measured diagonally)
Circuit Breaker (CB) Models
• LCD display with backlight shows the current and set • All “CB” model heaters are equipped with circuit breakers
temperature, time, inside relative humidity, system for overload and short circuit protection
status (operating mode and schedules) and outside
temperature (optional outdoor sensor required) • Factory wired and mounted on electric heat unit
• Smooth Setback Recovery starts system early to • Current sensitive and temperature actuated
achieve setpoint at start of program period • Manual reset
• Compressor short-cycle protection (5 minutes) • Flexible plastic circuit breaker cover protects circuit
• Up to four separate schedules are available plus breaker in areas with high humidity or unconditioned
Schedule IQ™ areas to prevent nuisance tripping
• One-Touch Away Mode - A quick and easy way to set the • Circuit breakers qualify as disconnect means at unit
cooling and heating setpoints while away in many areas, eliminate the need for field provided
disconnect
• Smart Away™ - Uses geo-fencing technology
to determine when the homeowner is within a • Consult local electrical code in your area
predetermined distance from the home to operate the Optional Accessories
system when leaving, away and arriving
• Wi-Fi remote monitoring and adjustment through a Single-Point Power Source Control Box
home wireless network for desktop PCs, laptops and • Control Box may be used with optional electric heat
apps for smartphones or tablets when single power supply is connected to multi-circuit
electric heat
• Smart home automation compatible with Amazon
Alexa®, Google Assistant and IFTTT • Field installs external to the unit cabinet on either side or
top
NOTE - See the iComfort® M30 Smart Wi-Fi Thermostat
Product Specifications bulletin in the Controls • Constructed of heavy gauge steel, baked enamel finish,
section for more information. prepunched mounting holes, electrical inlet knockouts,
and terminal strip
Remote Outdoor Temperature Sensor • Removeable cover provides easy access
• Used with the iComfort® M30 Smart Thermostat
• Dimensions (H x W x D) - 7 x 7 x 4 in.
• Outdoor sensor allows thermostat to
display outdoor temperature
NOTE - Sensor is required for the
Enhanced Dehumidification
Accessory (EDA).
S P ECIFICAT IONS
General Model Number CBA25UH-042 CBA25UH-048 CBA25UH-060
Data Nominal tonnage 3.5 4 5
Connections Suction/Vapor line (o.d.) - in. sweat 7/8 7/8 7/8
Liquid line (o.d.) - in. sweat 3/8 3/8 3/8
Condensate - in. fpt (2) 3/4 (2) 3/4 (2) 3/4
Indoor Net face area - ft.2 5.66 6.13 7.08
Coil Tube outside diameter - in. 3/8 3/8 3/8
Number of rows 3 3 3
Fins per inch 15 15 15
Blower Wheel nominal diameter x width - in. 10 x 8 12 x 10 12 x 10
Blower motor output - hp 1/2 1 1
1
Filters Size of filter - in. 18 x 20 x 1 18 x 20 x 1 18 x 20 x 1
Shipping Data -1 package - lbs. 169 179 190
ELECT RICAL DATA
Voltage - 1 phase (60 hz) 208/230V 208/230V 208/230V
2
Maximum overcurrent protection (unit only) 15 15 15
3
Minimum circuit ampacity (unit only) 5.0 9.5 9.5
Blower Motor Full Load Amps 2.5 7.6 7.6
1
Disposable filter.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.
CBA25UH-018 PERFORMANCE
CBA25UH-024 PERFORMANCE
CBA25UH-030 PERFORMANCE
CBA25UH-036 PERFORMANCE
CBA25UH-042 PERFORMANCE
Volt kW 1
Btuh Amps Ckt 1 Ckt 2 Ckt 1 Ckt 2 Circuit Overcurrent
Ampacity Protection
7.5 kW ECBA25-7.5 (16Y37) 208 5.6 19,200 7.6 43 --- 45 --- --- ---
Terminal Block
ECBA25-7.5CB (16Y41) 220 6.3 21,500 7.6 45 --- 45 --- --- ---
45A Circuit Breaker
230 6.9 23,500 7.6 47 --- 4
50 --- --- ---
10 kW ECBA25-10 (16Y38) 208 7.2 24,600 7.6 53 --- 60 --- --- ---
Terminal Block
ECBA25-10CB (16Y42) 220 8.0 27,500 7.6 55 --- 60 --- --- ---
60A Circuit Breaker
230 8.8 30,000 7.6 57 --- 60 --- --- ---
1 (25)
DETAIL OF PIPING PLATE
3/4 (19) 4-3/4
(121)
SUCTION
LINE
SUPPLY AIR
LIQUID
OPENING LINE CONDENSATE
14-1/2
DRAINS (2)
(368) 2-3/8 (Horizontal)
(60)
1 (25) C 1 (25) CONDENSATE
DRAINS (2)
4-3/8
(Upflow and
(111)
2-3/4 Downflow)
LOW VOLTAGE (70)
INLETS
(Top and Right Side) 3-1/2
LINE VOLTAGE 1-3/4 (89)
INLETS (44)
(Top and Left Side)
TOP VIEW
3/4
(19) B 22
(559)
LINE VOLTAGE
INLETS
(Top and Right Side)
AIR FLOW
PIPING
PLATE
1/2
1-1/8
(29)
D 1-1/8
(29) (13)
20-3/8
(518)
1-1/8
(29)
OPENING
OPENING
1-1/8
(29)
DETAIL OF PIPING PLATE
CONDENSATE
CONDENSATE DRAINS (2)
DRAINS (2) (Upflow and
4-3/4 (Horizontal)
(121) Downflow) 3-1/2
(89)
20-3/8
22 (518)
(559) OPENING
1-3/4
3/4 (44)
(19)
SUCTION 2-3/4
LINE LIQUID (70)
LINE 2-3/8 4-3/8
(60) (111)
LOW VOLTAGE INLETS
LINE VOLTAGE INLETS 1/2
(Either Side)
(Top and Right Side) (13)
SUCTION LIQUID
TOP VIEW LINE LINE
CONDENSATE DRAIN
PIPING PLATE (3)
LOW VOLTAGE (2-1/4 x 3-3/4) 1-1/8
FILTER
INLETS (29)
1 (25) ACCESS
(Top and Right Side)
C
SUPPLY AIR
OPENING B D
CIRCUIT AIR FLOW PIPING
PLATE OPENING
BREAKER
COVER
14-1/2
1 (25)
(368)
1 (25)
LINE VOLTAGE
3/4 A 1-1/8
(19) (29)
INLETS
(Top and Left Side)
16
(406)
6
(152)
E
SID
FRONT
ADJUSTABLE
21-1/4 20 (508) to
(540) 25 (635)
ALL UNITS
R EVISIONS
Sections Description of Change
Added Circuit Breaker Cover as standard for all Electric Heat Circuit Breaker (CB)
Electric Heat
models.
Visit us at www.lennox.com
For the latest technical information, www.LennoxPros.com
Contact us at 1-800-4-LENNOX
NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. ©2019 Lennox Industries, Inc.