Development of Concrete Roof Tile using Coir Fiber as Reinforcement and Bamboo Charcoal as Thermal Insulator

Development of Concrete Roof Tile using Coir


Fiber as Reinforcement and Bamboo Charcoal
as Thermal Insulator (March 2019)
Advisers: Engr. Edgardo S. Legaspi & Engr. Juan Paulo L. Bersamina
Authors: Roxete S. Alonzo, Ellaine Joyce M. Beljot, Rozalliene C. Homigop, Angelica P. Macaspac,
Arvin L. Nicolas, Angelo Paul O. Torreno

sheet that is lightweight but they give a poor indoor climate


Abstract— This project study is concerned in evaluating the (Darsana et al., 2016).
effects of bamboo charcoal as thermal insulator and coir fiber as Concrete roof tiles can be a great option of materials for
reinforcement in concrete roof tile. Properties of concrete roof roofing system however, there are number of drawbacks
tile was evaluated such as water absorption, permeability,
transverse breaking strength and by thermal experimental setup. encountered while in the process of installation and even while
Chemical composition of bamboo charcoal was done. 4 design in the time of its use.
mixes with controlled value of coir fiber, cement, sand, water and The primary downside of using concrete roof tiles is its
varying amount of bamboo charcoal were prepared and tested. difficulty in installation. It is heavy so the roofing system will
Three trials of physical properties of the concrete roof tile has been require to be well reinforced prior to the tile being laid. Along
done while the transverse breaking strength of the concrete roof to the fact that it is too heavy, the concrete roof tile being
tile had been verified after 7, 14 and 28 days. The specimens were
breakable, although hard and compact, they are also brittle that
also subjected to a thermal experimental setup to determine the
effects and role of bamboo charcoal to the temperature of the they will likely break if a person should stand on them in times
concrete roof tile. It was observed that the water absorption of repair and maintenance.
increases and the concrete roof tile becomes permeable as the One of the components of the concrete roof tile is the
amount of bamboo charcoal increases and this is due to its porous Portland cement concrete. Portland cement is a brittle material
structure. Addition of bamboo charcoal to the concrete roof tile and possess a very low tensile strength, limited ductility and
reduces the transverse breaking strength of the concrete roof tile.
little resistance to cracking. For this reason, a solution would be
The thermal experimental setup shows that the addition of
bamboo charcoal reduces the temperature beneath the tile. From the addition of small, closely spaced and uniformly dispersed
the results, it can be concluded that the concrete roof tile with coir fibers to concrete. This is known as fiber reinforced concrete.
fiber as reinforcement and bamboo charcoal as thermal insulator Natural fibers are cheap and locally available in many
has a significant effect to the mechanical, permeability and countries and as a construction material, costs very little since
thermal properties of the concrete roof tile. they are renewable, eco-friendly, economical and production
cost is also low (Vajje et al., 2013). Natural fibers have been
Index Terms—concrete roof tile, thermal experimental setup,
coir fiber, bamboo charcoal
recommended to be used in concrete to improve the strength
and durability of brittle materials due to its lignocellulosic
I. INTRODUCTION properties. This certain property will give more strength to the
concrete roof tile due to the crack control capability of the fiber
T HE Philippines, being a tropical country, is known to have
only two weathers: the dry and the rainy season. According
to PAGASA, temperatures are continuing to rise across the
(Sethunarayanan et al., n.d.).
Among the natural fibers, it has been studied that coir fibers
is reported to be most compatible with concrete. Coconut fiber
country. An example of this would be the heat index felt by the
or coir fiber, is one of the natural fibers that are abundantly
Filipino people last summer. The heat index data recorded by
available in tropical regions and is extracted from the husk of
PAGASA within those months ranges from 32 – 41 degrees,
the coconut fruit. It has many advantages, like for example, they
which are classified as dangerous as it could cause various
are moth-proof, resistant to fungi and rot, unaffected by
health hazards such as heat cramps, heat exhaustion and maybe
moisture and dampness, tough and durable, resilient, springs
even a stroke. They also defined this range as the “human
back to shape even after constant use, totally static free and easy
discomfort index” (Vera-Ruiz, 2018).
to clean (Darsana et al., 2016).
Extreme temperatures like these can be felt inside or outside
In a research study, bamboo has been widely acknowledged
our home, pushing the construction industry to innovate
and appreciated as an environmental building material for its
existing materials that can help to lessen the heat induced.
growing speed and mechanical properties (Huang, et al., 2013).
Roofing and walls, as the primary protection against weather
In terms of energy saving, charcoal has been given attention in
elements, must have a good resistance and durability like
the recent years because of its special microporous and
concrete roof tile, in contrast to the use of the conventional GI
R. Alonzo, E.J. Beljot, R. Homigop, A. Macaspac, A. Nicolas, A.P. Torreno

biological characteristics (Zhao et al., 2008). According to charcoal was then cooled and crushed. The sand that was used
Zhao, the surface area of bamboo charcoal is ten times more in the research was bought from construction supply store The
than wood charcoal. Also, the pores in the bamboo charcoal has cement used was a Type – IP (Ordinary Portland Cement) and
about four times more cavities which traps the air, keeping it was bought on the construction supply store. The supply for the
still and making it a good insulator. coir fiber was obtained from Philippine Eco Fiber in San Pablo,
Due to coir fiber’s excellent resistance to cracking and Laguna. The fiber was cleaned and was cut into 37.5 mm length.
bamboo charcoal’s extremely large surface area and its unique
A. Chemical Composition Analysis
microporous structure, combining these would be a promising
composite material in making concrete roof tiles which are less The chemical composition testing was done at DOST FPRDI
brittle and more effective in reducing heat in structures. This in Los Banos, Laguna. The research institute assessed the
research will develop the concrete roof tile in three different structural components of the bamboo charcoal such as fixed
ways: (i) to improve its design (ii) to improve its thermal carbon, volatile combustible matter, ash and moisture content.
properties by using bamboo charcoal and lastly, (iii) to develop Fixed carbon determines the amount of non-volatile carbon
the roofing material by adding fiber coir that will serve as a that remaining in a coal sample after combustion. Volatile
reinforcement to the concrete roof tile to prevent it from easily combustible matter determines the amount of non-water gases
breaking. released by combustion of a sample. Ash content determines the
amount of non-combustible material. Moisture content
II. SCOPE AND LIMITATIONS OF THE STUDY determines the amount of water that exists in the coal.
The study involve producing a concrete roof tile, made from B. Cement and Sand
cement, sand, bamboo charcoal and coconut coir fiber wherein The density of cement in connection with the design of
the properties are required to be determined as per ASTM. The Portland cement concrete mixtures was conducted according to
volume percentage for cement, fine aggregates and coir fiber the standard procedure of ASTM C 188-95. Le Chatelier Flask
will be constant but the amount of bamboo charcoal varies was filled with kerosene a little over 1 cc mark and then
which gives different mix designs. immersed in a water bath with temperature remain at 20 degree
The study will also focus on the contribution of bamboo Celsius for about 40 minutes. The kerosene level after
charcoal and coir fiber in thermal properties, strength and immersion was recorded as the initial reading. The cement
durability of the designed concrete roof tile, respectively. sample was added in the flask and then immersed in the bath
To observe the response of concrete roof tile when exposed for 40 minutes and the level of kerosene after the immersion
to the weather, it will be investigated from an experimental was recorded as the final reading.
setup developed in previous studies done by Halwatura et al.
and Silva et al. Specific gravity test was done using the standards procedure
The bamboo to be used was limited to waste bamboo that will of ASTM C128-01. The fine aggregates were set into its SSD
be collected in furniture shops in Cavite. Bamboos used was condition. SSD condition was confirmed when the sand was put
cleaned removing dirt from it by brushing. in the cone mold and tampered for 10 times and the slump of
The coir fiber to be used was bought in Pilipinas Ecofiber in the aggregate was observed. The sample weighing 500 grams
San Pablo, Laguna. The coir was used in the condition received were poured into the Chapman’s flask and was immersed in
from the manufacturers. It was cut to a certain length. Dirt and water bath at a temperature of 20 degrees Celsius for three
other materials were removed from it manually. No chemical hours. Datas were then collected and used for calculating the
treatment was done to the coir fiber used. specific gravity of sand. IEEE will do the final formatting of
The cement to used was Ordinary Portland Cement without your paper. If your paper is intended for a conference, please
any other additive and/or mixture. observe the conference page limits.
The properties of the developed product includes water
absorption, permeability, transverse breaking strength and an C. Mix Design
experimental setup for temperature observation. The 3.4. Mix Design
comparison of various mix design is presented through a Table 1 shows the four mix designs used which varies in
graphical analysis for variation of temperature beneath the tile bamboo charcoal. Water, cement, sand and coir fiber are
specimens done by experimental setup and a 7, 14 and 28-day constant. The mixed design was based on a study done by
basis for water absorption and transverse breaking strength and Ghana et al. in 2016, a concrete roof tile manual written by Bo
lastly, an acceptance criteria will be the basis for permeability Johannson and for the fiber length would be based from the
test. study done by Cook et al.
D. Concrete Roof Tile
III. METHODOLOGY
Proper mixing of raw materials such as water, cement and
The bamboo was obtained from Imus, Cavite, The aggregates was done to attain uniformity. Then, the mixture was
Department of Science and Technology – Forest Products placed in a mold to produce a concrete roof tile. The principle
Research and Development Institute (DOST-FPRDI) provided for making concrete roof tiles are based on simple technology
technical assistance in burning the bamboo into charcoal. The and equipment. After the right quantities of the raw materials
Development of Concrete Roof Tile using Coir Fiber as Reinforcement and Bamboo Charcoal as Thermal Insulator

was chosen and mix, the concrete roof tile mortar was put on coarser wire mesh, removing visible surface water with a damp
the mold until it is completely filled. The excess concrete roof cloth; weigh and record as Ws (saturated weight). For drying,
tile mortar was scraped off until a smooth surface is achieved. subsequent to saturation, all specimens were dried in a
Specimens were stored immediately after finishing until the ventilated oven at 212 to 239°F (100 to 115°C) for not less than
removal of the molds to prevent loss of moisture from the 24h. The weight of dried specimens were recorded as Wd
specimens. It was stored on a cool place and was kept damp. (oven-dry weight). Absorption will be calculated as follows:
𝑊𝑠 − 𝑊𝑑
TABLE I 𝐴𝑏𝑠𝑜𝑟𝑝𝑡𝑖𝑜𝑛, % = [ ] 𝑥 100 (1)
𝑊𝑑
DESIGN MIX PROPORTIONS
F. Permeability Test
CONCRETE MIXTURE ADDITIVE
The permeability test was used to determine whether the
MIXTURE C:S W/C Ratio Coir Fiber Coir Fiber BAMBOO water can pass through the concrete roof tile in given span of
SET 1:2.5 0.55 37.5 mm Length CHARCOAL time. The frame was constructed 3 ft (1 m) by 3 ft (1 m) at a
pitch not to exceed 30° without nails or roofing felt.
(g) (g) (g) (mm) (g)
The tiles were installed as would be installed during field
MIX A 563 1408 253 37.5 0 application for tile headlap without the use of nails. A 1⁄2 in.
MIX B 563 1408 253 37.5 5
diluge pipe (12 mm) inside diameter with 1⁄16 in. (2 mm) holes
on 11⁄2 in. (38 mm) was placed over the top course of the roof
MIX C 563 1408 253 37.5 10
to simulate run down from the higher course. A spray nozzle
MIX D 563 1408 253 37.5 15 was placed over the center of the tile to simulate direct rainfall
and such that every tile on the roof received an equal volume of
water. The acceptable criteria for the concrete roof tile to pass
will be: (i) when the free water has not formed on the underside
of the tile and (ii) not more than 25% of the visible underside of
any one tile shall show dampness.
G. Transverse Breaking Strength
The transverse breaking strength of tiles was determined as
described in the Modulus of Rupture Test in ASTM C 67-03.
Test specimen were supported flatwise unless specified and
reported otherwise (that is, apply the load in the direction of the
(a) (b) depth of the unit) on a span approximately 1 in. (25.4 mm) less
than the basic unit length and loaded at midspan. If the
Fig. 1. From left (a) Production Process, (b) Concrete roof output specimens will have recesses (panels or depressions) place
them so that such recesses are on the compression side. The load
was applied to the upper surface of the specimen through a steel
bearing plate ¼ in. (6.35 mm) in thickness and ½ in. (38.10 mm)
in width and of a length at least equal to the width of the
specimen. The supports for the test specimen were free to rotate
in the longitudinal and transverse directions of the test specimen
and will be adjusted so that they will exert no force in the
directions. For the speed of testing, the rate of loading shall not
exceed 2000 lbf (8896 N)/min. But this requirement will be
considered as being met if the speed of the moving head of the
testing machine immediately prior to application of the load is
not more than 0.05 in. (1.27 mm)/min. Modulus of rupture of
Fig. 2. Concrete roof tile specimens each specimen was calculated and reported to the nearest 1 psi
(0.01 MPa) as follows:
E. Water Absorption Test 𝑙
( − 𝑥)
This test is used to determine the capacity of concrete roof 𝑆 = 3𝑊 2 2 (2)
tile to absorb water when it is subjected to heavy rain. For 𝑏𝑑
saturation, the test specimens were immersed in water at a
temperature of 60 to 80°F (15.6 to 26.7°C) for 24 h. The Where S is the modulus of rupture of the specimen at the
specimens were weighed while suspended by a metal wire and plane of failure, lb/in2 (Pa), W is the maximum load indicated
completely submerged in water and record Wi (immersed by the testing machine, lbf (N), l is the distance between the
weight). The specimens were remove from the water and allow supports, in (mm), b is the depth of the specimen at the plane of
to drain for 1 min by placing them on a 3⁄8-in. (9.5-mm) or v, failure, in mm and x is the average distance from the midspan
of the specimen at the plane of failure measure in the direction
R. Alonzo, E.J. Beljot, R. Homigop, A. Macaspac, A. Nicolas, A.P. Torreno

of the span along the centerline of the bed surface subjected to B. Chemical Analysis of Bamboo Charcoal
tension, in mm. The chemical analysis of bamboo charcoal was included in
H. Thermal Experimental Setup the study to further understand the effects of bamboo charcoal
to the concrete roof tile and to also know what the coal ranking
The thermal properties of the roof tiles were investigated
of the sample would be. The analysis done was the proximate
from an experimental setup, similar to the set ups developed in
chemical analysis which includes determining the fixed carbon,
previous studies. Roof tiles were covered with an insulating
volatile combustible matter, ash and moisture content.
material in all surfaces except the top surface. Space between
the insulating material and the tile was filled with Styrofoam to TABLE I
avoid heat transferring from other surfaces except the top PROXIMATE ANALYSIS RESULTS
surface. Two Temperature MAX 6675 thermocouple amplifier TEST RESULTS (%)
module with Type K thermocouple were placed on the top and Fixed Carbon 63.37 ± 0.33
the bottom surfaces at the middle of the tile. The temperature
Volatile Combustible Matter 22.47 ± 0. 83
was measured in every 30 mins from 8:00 am to 5:00 pm. The
amplifier measured the output of the K thermocouple and Ash 14.15 ± 0.17
provided the results to Arduino via SPI. Moisture Content 2.50 ± 0.31

Based on the results, the bamboo charcoal used can be ranked


as a medium rank coal, specifically, a bituminous coal.
The moisture content together with the ash content are
important charcoal’s chemical properties that define its quality.
Moisture lowers the calorific value of charcoal. The ash content
(c) determines the amount of non-combustible matter. Based from
the results shows, the ash content and moisture content is low
which shows that the bamboo charcoal’s carbonization has been
done properly.
C. Water Absorption

(a)

Fig. 4 Water absorption


(b)
(d)
The required maximum water absorption values for
lightweight concrete roof tile to 18%. The maximum average
water absorption recorded was 12.28% which is mix D.
As shown from Fig. 4, it can be observed that the water
absorption is directly proportional to the increase in bamboo
charcoal due to charcoal’s porous structure.
Fig. 3. From left (a) and (b) water absorption, (c) permeability test, (d) Water absorption is used as an indicator for assessing the
transverse breaking strength, (e) thermal experimental setup durability of concrete it also determines the capacity of concrete
roof tile to absorb water when it is subjected to heavy rain.
IV. RESULTS AND DISCUSSION Bamboo charcoal has an effect on the water absorption due to
A. Cement and Sand its porous structure. The void spaces were filled with water
In accordance to ASTM procedures, the cement has a when submerged.
specific gravity of 2.936 while sand has a specific gravity of D. Permeability
2.513. The density of coir fiber was determined by volume
displacement method and was recorded as 0.9 g/mL. Fig. 4 Water absorption
(1)
On 7th day, Mix A (0% bamboo charcoal) and Mix B (2.5%
Development of Concrete Roof Tile using Coir Fiber as Reinforcement and Bamboo Charcoal as Thermal Insulator

bamboo charcoal) have passed the permeability test as water did concrete roof tile increases, the water absorption also increases.
not penetrate beneath the tile and showed no dampness. Mix C The maximum average water absorption was 12.28 % of the
(5% bamboo charcoal) and Mix D (7.5% bamboo charcoal) mix D which contains 7.5% bamboo charcoal content. (2)
have become more permeable because adding bamboo charcoal Permeability was also found to be directly proportional to the
increased the porosity of the roof tile showing gradual amount of bamboo charcoal content. As the amount of bamboo
dampness on the underside of the tile but on the 14th day and charcoal increase, the roof tile becomes permeable. (3)
28th day, all roof tile have shown no freewater formed and less Addition of bamboo charcoal to the concrete roof tile affects the
dampness were found on it. early strength of the concrete roof tile as it retards the cement
hydration and prolonging the setting time of the cement. (4) The
E. Transverse Breaking Strength
thermal experimental shows that the addition of bamboo
charcoal reduces the temperature beneath the tile which causes
the indoor environment cooler. When the humidity or the
moisture level of the surrounding is higher than of the bamboo
charcoal, the bamboo charcoal adsorbs the mass of moisture in
the air, vice versa. (5) The specimen with 2.5% bamboo
charcoal content is the governing mix having a modulus of
rupture of 4.25 MPa ,water absorption of 9.08%, passing the
permeability test and lowers the temperature indoors by 2.35°C.
Fig. 5 Modulus of Rupture The proponents would like to present the following
recommendations for further development of the study.
Fig 5 shows that incorporating bamboo charcoal in concrete Addition of admixtures is recommended to improve the flexural
roof tile has an effect in the early flexural strength. Strength of strength of the tile. Further study of the effect of fineness of
the roof tile increases as time progresses. Bamboo charcoal bamboo charcoal to the strength of the roof tile by scanning
decreases the strength of the roof tile. Mix A was able to reach electron microscope. For an increase in the amount of bamboo
its strength faster than Mix B, C and D, which shows that the charcoal in order to attain a cooler indoor environment, the use
charcoal retards the cement hydration and prolonging the of water proofing agent is highly recommended. When it comes
setting time of the cement. to production, it is better that the water, sand and cement will
be mixed first and bamboo charcoal will be added after because
F. Thermal Experimental Setup
bamboo charcoal has an effect on the workability of the
concrete roof tile. A suitable mold is recommended other than
the use of GI sheet to better control the thickness of the
specimen.

REFERENCES
[1] PAGASA-DOST. (n.d.). Climatology and Agrometeorology.
Retrieved from Philippine Atmospheric, Geophysical and
Astronomical Services Administration:
Fig. 6 Modulus of Rupture https://www1.pagasa.dost.gov.ph/index.php/27-climatology-and-
agrometeorology
The addition of bamboo charcoal to the concrete roof tile [2] Vera-Ruiz, E. D. (2018, May 2). Metro Manilans Experience
shows a significant effect on the thermal performance of the Hottest Day of the Year. Retrieved from Manila Bulletin:
tiles. Mix A (0% bamboo charcoal) shows the highest https://news.mb.com.ph/2018/05/02/metro-manilans-
temperature value beneath the tile, while Mix D (7.5%) which experience-hottest-day-of-the-year/
has the highest content of bamboo charcoal shows the lowest [3] Dietz, M. E. (2007). Low Impact Development Practices: A
temperature beneath the tile. On average, mix A, mix B, mix C Review of Current Research and Recommendations for Future
and mix D has reduced the temperature beneath the tile by about Directions. Water, Air, Soil Pollution, 186:351-363.
1.62°C, 2.35°C, 3.15°C and 4.78°C, respectively. The reduction [4] Ahiablame, L. M., Engel, B. A., & Chaubey, I. (2012).
Effectiveness of Low Impact Development Practices:
in the temperature beneath the tile is due to the improved porous
Literature Review and Suggestions for Future Research.
nature of the tile that is caused by the mixing of bamboo
Water, Air and Soil Pollution, 4253-4273.
charcoal
[5] Bankoff, G. (2003). Constructing Vulnerability: The Historical,
Natural and Social Generation of Flooding in Metropolitan
V. CONCLUSIONS AND RECOMMENDATIONS Manila. Disasters, 224-238.
Based on the results of the experiments, the following [6] Davis, A. P. (2005). Green Engineering Principles Promote
conclusions were derived: (1) Water absorption is directly Low-Impact Development. Environmental and Science
proportional to the amount of the bamboo charcoal that was Technology, 338A-344A.
being added in the concrete roof tile mixture. As the amount of [7] Martin-Mikle, C. J., Beurs, K. M., Julian, J. P., & Meyer, P. M.
(2015). Identifying Priority Sites for Low Impact Development
R. Alonzo, E.J. Beljot, R. Homigop, A. Macaspac, A. Nicolas, A.P. Torreno

(LID) in a Mixed-Use Watershed. Land and Urban Planning, Heat Index. Retrieved from
29-41. https://www.weather.gov/safety/heat-index
[8] Dietz, M. E. (n.d.). Effectiveness of Low Impact Development [27] What are the Mechanical Properties of Bamboo? (n.d.).
Practices: Literature Review and Suggestions for Future Retrieved from https://www.bambooimport.com/en/blog/what -
Research. are-the-mechanical-properties-of-bamboo
[9] Chang, C. L. (2008, June 20). Production of Thermal Insulation [28] Activated charcoal. (n.d.). Retrieved from https://medical-
Composites Containing Bamboo Charcoal. Textile Research dictionary.thefreedictionary.com/activated charcoal
Journal, 555-560. [29] Kabir, H. (2017, April 14). What is Bamboo Tree Its Uses and
[10] Flatow, I. (2008, April 11). Charcoal May Help Improve Soil Benefits. Retrieved from
Quality. (D. M. Guo, Interviewer) http://bambooproductsdepot.com/bamboo-tree-uses-benefits/
[11] Ronda, R. A. (2017, May 10). High Quality Charcoal Produced
From Bamboo. Retrieved from The Philippine Star:
https://www.philstar.com/business/science-and-
environment/2017/05/10/1698654/high-quality-charcoal-
produced-bamboo
[12] (n.d.). Retrieved from http://www.protile.co.za/material.html
Advantages of Building with Bamboo. (n.d.). Retrieved from
https://www.guaduabamboo.com/construction/advantages-of-
building-with-bamboo
[13] Bamboo Anatomy. (n.d.). Retrieved from
https://lewisbamboo.com/bamboo-anatomy/
[14] Britannica, T. E. (2018, April 03). Coconut palm. Retrieved
from https://www.britannica.com/plant/coconut-palm
[15] Concrete roof tiles. (n.d.). Retrieved from
http://www.build.com.au/concrete-roof-tiles
[16] How do thermocouples work? (2018, January 18). Retrieved
from
https://www.explainthatstuff.com/howthermocoupleswork.html

[17] Li, Z., Wang, L., & Wang, X. A. (2007, 06). Cement
Composites Reinforced with Surface Modified Coir Fib ers.
Journal of Composite Materials, 41(12), 1445-1457.
doi:10.1177/0021998306068083
[18] Malasig, J. (2018, April 26). It's getting hot in here: Manila's
'extreme' heat index level. Retrieved from
http://www.interaksyon.com/extreme-heat-index-levels-
manila-2018/
[19] Natural Fiber. (n.d.). Retrieved from
https://www.sciencedirect.com/topics/materials-
science/natural-fiber
[20] P. (2016, October 13). 8 Different Types of Roofing Tiles:
Roof Tile Material Options. Retrieved from
http://phoenixroofingteam.com/blog/types-roofing-tiles/
[21] Portland Cement. (n.d.). Retrieved from
http://www.pavementinteractive.org/portland -cement/
[22] Roof tiles. (2018, July 10). Retrieved from
https://en.wikipedia.org/wiki/Roof_tiles
[23] S, S. (2014, August 10). Coir Fiber Reinforced Concrete.
Retrieved from https://www.omicsonline.org/open -access/coir-
fiber-reinforced-concrete-2165-8064.1000163.php?aid=30263

[24] Thermal Insulation. (n.d.). Retrieved from


http://performativedesign.com/definition/thermal-insulation/

[25] Thermal insulation performance of bamboo- and wood-based


shear walls in light-frame buildings. (2018, March 10).
Retrieved from
https://www.sciencedirect.com/science/article/pii/S037877881
7305960
[26] US Department of Commerce, & NOAA. (2018, April 10).