Sie sind auf Seite 1von 14

Arval Composite floor decks

Cofraplus 60

GEOMETRIC CHARACTERISTICS

Pre-painted surface
d

Thickness of
the concrete slab
from 100 to 280 mm

58

207 101 62
1035

APPLICATIONS
Cofraplus 60 is an open rib trapezoidal and nestable composite Cofraplus 60 is specially designed for structures with moderate
floor deck used for the construction of concrete slabs. live loads and medium spans.
Cofraplus 60 avoids removal of formwork, reduces the dead Flooring over crawlspaces must be accessible and ventilated.
weight of the floor and saves one layer of steel reinforcement.

DEFINITIONS / STANDARDS
Steel specification Versions
• Standard NF EN 10326 : “steel bands and sheets for construction Three versions are available :
with hot-dip coating”. • The standard version is called COFRAPLUS 60.
• Standard XP P 34-301 : “steel bands and sheets for construction,
galvanised pre-painted or coated with an organic calendereed
construction industry grade film”.
• Standard EN 10169-3 : “Flat products in steel continuously coated
in organic material (pre-painted) - part 3 : product for interior
applications in the construction industry”.
• Steel : S350 GD in accordance with standard NF EN 10326. • The version specially adapted for use as a composite beam
with Hilti or Nelson type conncetors fitted across the steel floor
Formwork deck is called COFRAPLUS 60 : special fabrication on request.
Cofraplus 60 serves as load-bearing formwork, between joists
for laying without props, or between lines of props and joists.
Its lightness faciliates the handling of large floor decks delivered COFRAPLUS 60 C
up to a length of 15 metres. (bottom of rib connector version)

Steel reinforcement
The lateral notching binds to the concrete to form a composite
floor slab.
As a steel reinforcement, Cofraplus 60, in 0,75 mm thickness adds
10,29 cm2/ml or 13,91 cm2/ml of steel with a thickness of 1,00 mm • COFRAPLUS 60 can be prepunched to enable welded studs to
in the span direction of the floor. be fitted in the workshop.
Coating This version is called COFRAPLUS 60 P :
• galvanised Z 275. Study and fabrication on request.
• pre-painted galvanised : (up to a thickness of 1,00 mm).
Interior 12 :
COFRAPLUS 60 P
- category II iaw. XP 34-301 (the prepunched layout drawing must be supplied)
- category CPI2 iaw. EN 10169-3
Haiplus® 25 :
- category IIIa iaw. XP 34-301
- category CPI3 iaw. EN 10169-3
• For other coatings contact us.

Regulation
• Technical Approval 3/03-390 and 3/03-390* 01 Add.

3
Photographs :
• Computer synthesised image (The Tower)
Sport City Tower, Doha (Qatar)
Architect : Concept Architect
Hadi Simaan, Florida (USA)
Structure : Arup, London (United Kingdom)
• Middle right
car park at La Pardieu
Main contractor : Lyon Park Auto
Architect : D. Richard
• Bottom right
Madou Tower, Brussels (Belgium)
Architects : Assar and Archi 2000
Photos : ArcelorMittal Constructions
Sport City Tower : Midmac - Sixco
Arval Composite floor decks
Cofraplus 60

MAXIMUM APPLIED LOAD TABLES in daN/m2 with details :


- Of the number of props in construction stage,
- Of the maximum and minimum value of the total section of the steel mesh reinforcement to be provided to the upper part of
the slab with a covering of 20 mm,

Single span e = 0,75 mm


L
Smini (cm2/m) 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80
Smax (cm2/m) 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80
Thickness Span L in cm
Slab in mm 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400
280 3000 2830 2600 2390 2200 2040 1890 1760 1640 1530 1430 1340 1260 1180 1110 1050 980 930 870 820 720
270 2980 2720 2500 2290 2120 1960 1820 1690 1570 1470 1370 1290 1210 1130 1070 1000 950 890 840 800 720
260 2860 2610 2390 2200 2030 1880 1740 1620 1510 1410 1320 1230 1160 1090 1020 960 910 850 810 760 720
250 2740 2500 2290 2110 1940 1800 1670 1550 1440 1350 1260 1180 1110 1040 980 920 870 820 770 730 690
240 2620 2390 2190 2010 1860 1720 1590 1480 1380 1290 1200 1130 1060 990 930 880 830 780 740 700 660
230 2500 2280 2090 1920 1770 1640 1520 1410 1320 1230 1150 1070 1010 950 890 840 790 740 700 660 630
220 2380 2170 1990 1830 1690 1560 1450 1340 1250 1170 1090 1020 960 900 850 800 750 710 670 630 600
210 2380 2060 1890 1730 1600 1480 1370 1270 1190 1110 1040 970 910 850 800 760 710 670 630 600 560
200 2380 1950 1790 1640 1510 1400 1300 1210 1120 1050 980 920 860 810 760 710 670 630 600 560 530
190 2260 1950 1690 1550 1430 1320 1220 1140 1060 990 920 860 810 760 720 670 630 600 560 530 500
180 2120 1950 1590 1460 1340 1240 1150 1070 1000 930 870 810 760 710 670 630 600 560 530 500 470
170 1990 1830 1590 1370 1260 1160 1080 1000 930 870 810 760 710 670 630 590 560 520 490 470 440
160 1850 1710 1580 1270 1170 1080 1000 930 870 810 760 710 660 620 590 550 520 490 460 430 410
150 1720 1580 1460 1270 1090 1010 930 870 810 750 700 660 620 580 540 510 480 450 430 400 360
140 1590 1460 1350 1250 1000 930 860 800 740 690 650 610 570 530 500 470 440 420 370 310 260
130 1450 1340 1240 1150 1000 850 790 730 680 630 590 550 520 490 460 430 390 320 260 210 170
120 1320 1210 1120 1040 970 850 720 660 620 580 540 500 470 440 380 330 270 210 170 120
110 1190 1090 1010 940 870 810 720 600 560 520 480 430 360 310 250 210 160
100 1060 970 900 830 770 720 680 600 490 410 340 280 230 180

Single span e = 0,75 mm


L
Smini (cm2/m) 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80
Smax (cm2/m) 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80
Thickness Span L in cm
Slab in mm 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590
280 670 630 590 550 510 470 430 400 370 340 310 280 260 230 210 190 140 120 100
270 650 610 570 530 490 450 420 380 350 320 300 270 250 220 200 180 140 120 100
260 650 580 550 510 470 430 400 370 340 310 290 260 240 220 190 170 140 120 100
250 650 560 520 490 450 420 390 350 330 300 270 250 230 210 190 170 140 120 100
240 620 560 500 470 430 400 370 340 310 290 260 240 220 200 180 160 140 120 100
230 590 560 500 450 410 380 350 330 300 280 250 230 210 190 170 150 140 120 100
220 560 530 500 450 400 370 340 310 290 260 240 220 200 180 170 150 130 120 100
210 530 500 480 450 400 350 320 300 270 250 230 210 190 170 160 140 110
200 500 480 450 430 400 350 310 280 260 240 220 200 180 140 110
190 470 450 420 400 380 350 310 280 250 220 190 150 120
180 450 420 400 380 360 320 270 220 180 160 120
170 420 390 370 330 280 230 190 150 120
160 390 350 290 240 200 160 120
150 300 250 200 160 130
140 210 170 130
130 130
120
110
100

no props 1 line of props during laying 2 lines of props during laying 3 lines of props during laying

Hypotheses used :
- Equal spans, - Deflection during laying = L/240,
- Distributed live load, - Active deflection in service = L/350 if L ≤ 350 cm and
- Permanent load nil, L/700 + 0,5 cm if L > 350 cm,
- Normal weight concrete 2400 daN/m3, - Réduction of maximum moment on support = 15 %.
- Steel reinforcement : yield point 500 MPa,

Nota : for all other assumptions, further calculations must be carried out.

7
Arval Composite floor decks
Cofraplus 60

APPLIED LOADS
The Technical Aproval of Cofraplus 60 takes account of the distributed, concentrated and linear loads.
It is formulated for load intensities not exceeding the following limits :
• static point load : < 20 kN • dynamic point load : < 15 kN • moving loads for vehicles
• static linear load : ≤ 10 kN par lm and spaced at at least 1,20 m where the maximum load per
from each other. axle does not exceed 30 kN.

These limitations are applied in the absence of a complete check of the distribution of the loads.

PERMISSIBLE SPANS L (cm) in the construction stage when fitting the standard version of Cofraplus 60
• In the construction stage, Cofraplus 60 thickness 0,75 mm can withstand spans to limits L according to the table below which takes
account of the deflection conditions L/240.
• When lines of props are required, they must divide the span into equal parts.

L L L

1 span 2 continuous bays


Thickness of slab in mm no props 1 lines of props 2 lines of props Thickness of slab in mm no props 1 lines of props 2 lines of props
100 273 330 330 100 360 360 360
110 262 363 363 110 348 396 396
120 252 396 396 120 336 432 432
130 244 429 429 130 326 468 468
140 237 462 462 140 316 504 504
150 231 495 495 150 306 540 540
160 225 525 528 160 295 525 576
170 220 509 561 170 285 509 612
180 215 495 594 180 276 495 648
190 210 481 617 190 268 481 684
200 206 469 637 200 260 469 703
210 203 457 657 210 253 457 686
220 199 446 670 220 247 446 670
230 196 436 654 230 241 436 654
240 193 427 640 240 235 427 640
250 190 418 627 250 230 418 627
260 187 410 615 260 225 410 615
270 184 402 603 270 219 402 603
280 182 394 591 280 214 394 591

L L L L L

2 rebated spans 3 continuous bays


Thickness of slab in mm no props 1 lines of props 2 lines of props Thickness of slab in mm no props 1 lines of props 2 lines of props
100 273 360 360 100 346 360 360
110 262 396 396 110 333 396 396
120 252 432 432 120 322 432 432
130 244 468 468 130 312 468 468
140 237 504 504 140 304 504 504
150 231 540 540 150 296 504 504
160 225 525 576 160 289 504 504
170 220 509 612 170 281 504 504
180 215 495 648 180 276 504 504
190 210 481 684 190 268 504 504
200 206 469 703 200 260 504 504
210 203 457 686 210 253 504 504
220 199 446 670 220 247 504 504
230 196 436 654 230 241 504 504
240 193 427 640 240 235 504 504
250 190 418 627 250 230 504 504
260 187 410 615 260 225 504 504
270 184 402 603 270 219 504 504
280 182 394 591 280 214 504 504

5
Arval Composite floor decks
Cofraplus 60

TECHNICAL CHARACTERISTICS OF THE STANDARD VERSION FLOOR


Properties of the floor deck
Nominal thickness of the sheet metal t mm 0,75 0,88 1,00 1,25
Weight per square metre daN/m2 8,53 10,00 11,37 14,22
Effective section : A cm2/ml 10,29 12,17 13,91 17,57
4
Second moment of area : i cm /ml 55,12 65,21 74,53 93,94
Neutral axis position : vi cm 3,33 3,33 3,33 3,33
Section modulus : I/vi cm3/ml 16,55 19,58 22,38 28,20

Nominal concrete consumption


Thickness d mm 100 110 120 130 140 150 160 180 200 240 280
Volume in litres l/m2 65 75 85 95 105 115 125 145 165 205 245
Theoretical weight
kN/m2 1,55 1,79 2,03 2,27 2,51 2,75 2,99 3,47 3,95 4,91 5,87
of concrete alone *
* To obtain the total weight of the slab, add the weight of the concrete due to deflection and the weight of the profile.
Bulk density of the concrete 2400 daN/m3.

Characteristics of the floor across the span


Thickness d mm 100 110 120 130 140 150 160 180 200 240 280
For t = 0,75 mm
cm 6,67 7,67 8,67 9,67 10,67 11,67 12,67 14,67 16,67 20,67 24,67
distance d-vi
Distance x cm 3,25 3,56 3,90 4,13 4,40 4,65 4,90 5,36 5,79 6,59 7,31
l 15 cm4/m 252 329 421 527 649 786 938 1289 1705 2731 4024
z cm 5,59 6,48 7,39 8,29 9,20 10,12 11,04 12,88 14,74 18,47 22,23

Thickness d mm 100 110 120 130 140 150 160 180 200 240 280
For t = 1,00 mm
cm 6,67 7,67 8,67 9,67 10,67 11,67 12,67 14,67 16,67 20,67 24,67
distance d-vi
Distance x cm 3,59 3,94 4,28 4,60 4,90 5,20 5,48 6,01 6,51 7,43 8,27
l 15 cm4/m 309 404 517 648 799 969 1159 1600 2123 3424 5073
z cm 5,47 6,36 7,24 8,14 9,04 9,94 10,84 12,67 14,50 18,19 21,91

Notation x
•d : thickness of the slab, including steel floor profile
• vi : distance of the neutral axis of the steel floor profile to its lower surface d
•x : distance of the neutral axis of the slab to its upper surface Vi
• l15 : equivalent combined inertia in steel corresponding to Ea/Eb = 15
•z : conventional lever arm (d-vi - x/3) The values of “m” et de “k” are given in
the unit system : length in cm, force in daN.
Permissible shear between metal sheet and concrete Slide
τ = T / 100 . z ≤ m . ρ d/L + k Strength Static Dynamic
with load load
ρ = ratio of the sheet metal section to the effective concrete section m 3238 1775 1420
(height d-vi) k 0,1286 0,5302 0,4242
L = calculation span in cm

Fire resistance
FR : fire resistance grade of the concrete subfloor. FR required 60’ 90’ 120’ 180’
A minimum thickness is required in order to meet the unexposed
d mini in cm 11 12 14 17
surface temperature criteria.
In the absence of special reinforcement Cofraplus floor achieves FR 30’ grade. For higher FR grades, the resistance of the floor for
the required fire exposure time must be justified by taking into account only the additional reinforcement provided to the slab.

Acoustic insulation
The acoustic behaviour of the subfloor corresponds to mass law. (values calculated by modelling)

Thickness d in mm 100 110 120 130 140 150 200 240 280

Rw (C;Ctr) 44 (-1;-3) 45 (-1;-4) 46 (-1;-4) 47 (-1;-4) 48 (-1;-5) 48 (-1;-4) 52 (-2;-6) 54 (-1;-7) 56 (-1;-7)

4
Arval Composite floor decks
Cofraplus 60

MESH REINFORCEMENT, SLAB DEPTH AND PROPPING REQUIREMENTS UNDER TYPICAL APPLIED LOADS
These tables apply to simple cases where there are distributed loads and equal spans.
Using the Cofra 4 software, our technical team can carry out composite floor deck studies in the shortest possible time.

Single span
L
2
q = 2.50 kN/m e = 0,75 mm q = 3,50 kN/m2 e = 0,75 mm
L Number AcM d TB L Number AcM d TB
(cm) of props (cm) (cm) of props (cm)
Up to 270 0 PAF-R 10 Up to 270 0 PAF-R 10
from 270 to 310 1 PAF-R 10 from 270 to 290 1 PAF-R 10
from 310 to 340 1 PAF-R 11 from 290 to 320 1 PAF-R 11
from 340 to 360 1 PAF-R 12 from 320 to 340 1 PAF-R 12
from 360 to 380 1 PAF-R 13 from 340 to 360 1 PAF-R 13
from 380 to 400 1 PAF-R 14 from 360 to 380 1 PAF-R 14
from 400 to 420 1 PAF-R 15 from 380 to 400 1 PAF-R 15
from 420 to 430 1 PAF-R 16 from 400 to 420 1 PAF-R 16
from 430 to 450 1 PAF-R 17 from 420 to 430 1 PAF-R 17
from 450 to 470 1 PAF-R 18 from 430 to 450 1 PAF-R 18
from 470 to 480 1 PAF-R 19 from 450 to 460 1 PAF-R 19
from 480 to 490 2 PAF-R 19 from 460 to 470 2 PAF-R 23
from 490 to 500 2 PAF-R 21 from 470 to 480 2 PAF-R 25
from 500 to 510 2 PAF-R 23 from 480 to 490 2 PAF-R 27
from 510 to 520 2 PAF-R 25
from 520 to 530 2 PAF-R 27

Single span
L
q = 5,00 kN/m2 e = 0,75 mm q = 8,00 kN/m2 e = 0,75 mm
L Number AcM d TB L Number AcM d TB
(cm) of props (cm) (cm) of props (cm)
Up to 270 0 PAF-R 10 from 200 to 230 0 PAF-R 10
from 270 to 290 1 PAF-R 11 from 230 to 250 0 PAF-R 11
from 290 to 310 1 PAF-R 12 from 250 to 270 1 PAF-R 14
from 310 to 320 1 PAF-R 13 from 270 to 280 1 PAF-R 15
from 320 to 340 1 PAF-R 14 from 280 to 290 1 PAF-R 16
from 340 to 350 1 PAF-R 15 from 290 to 300 1 PAF-R 17
from 350 to 360 1 PAF-R 16 from 300 to 310 1 PAF-R 18
from 360 to 370 1 PAF-R 17 from 310 to 320 1 PAF-R 19
from 370 to 390 1 PAF-R 18 from 320 to 330 1 PAF-R 20
from 390 to 400 1 PAF-R 19 from 330 to 340 1 PAF-R 21
from 400 to 410 1 PAF-R 20 from 340 to 350 1 PAF-R 22
from 410 to 420 1 PAF-R 21 from 350 to 360 1 PAF-R 24
from 420 to 430 1 PAF-R 22 from 360 to 370 1 PAF-R 25
from 430 to 440 2 PAF-R 26 from 370 to 380 1 PAF-R 26
from 440 to 450 2 PAF-R 28 from 380 to 390 1 PAF-R 27

AcM : Anti crack Mesh


TB : Top Bars

Basis of table Complementary assumptions :


q = imposed load • Normal weight concrete 2400 daN/m3
q = q1 + g1 L
q1 = imposed live load • Deflection at laying stage =
240
g1 = imposed permanent load L
(partition wall, floor covering, suspended ceilings) taken • Active deflection in service =
350
into account as operating loads.
e.g. : L = 3,50 m • Shrinkage = 4 x 10-4
q1 = 1,50 kN/m2 • Covering of top bars = 20 mm
g1 = 1,00 kN/m2 • Top Bars : yield point 500 MPa
Consult the table : q = 2,50 kN/m2.

12 = slab depth d
PAF-R 12
PAF-R = Anti Crack Mesh

6
Arval Composite floor decks
Cofraplus 60

MESH REINFORCEMENT, SLAB DEPTH AND PROPPING REQUIREMENTS UNDER TYPICAL APPLIED LOADS
These tables apply to simple cases where there are distributed loads and equal spans.
Using the Cofra 4 software, our technical team can carry out composite floor deck studies in the shortest possible time.

2 continuous bays
L L
2
q = 2,50 kN/m e = 0,75 mm q = 3,50 kN/m2 e = 0,75 mm
L Number AcM d TB L Number AcM d TB
(cm) of props (cm) (cm) of props (cm)
Up to 350 0 PAF-R 10 PAF-R Up to 300 0 PAF-R 10 PAF-R
from 350 to 360 0 PAF-R 10 ST 10 from 300 to 330 0 PAF-R 10 ST 10
from 360 to 370 1 PAF-R 11 ST 20 from 330 to 360 0 PAF-R 10 ST 20
from 370 to 390 1 PAF-R 11 ST 25 from 360 to 370 1 PAF-R 11 ST 25
from 390 to 430 1 PAF-R 12 ST 25 from 370 to 380 1 PAF-R 11 ST 30
from 430 to 440 1 PAF-R 13 ST 25 from 380 to 390 1 PAF-R 11 ST 35
from 440 to 460 1 PAF-R 13 ST 30 from 390 to 400 1 PAF-R 12 ST 30
from 460 to 470 1 PAF-R 14 ST 30 from 400 to 420 1 PAF-R 12 ST 35
from 470 to 500 1 PAF-R 14 ST 35 from 420 to 440 1 PAF-R 13 ST 35
from 500 to 520 1 PAF-R 15 ST 35 from 440 to 450 1 ST 10 13 ST 45
from 520 to 530 1 PAF-R 15 ST 50 from 450 to 470 1 PAF-R 14 ST 35
from 530 to 540 2 PAF-R 16 ST 35 from 470 to 490 1 PAF-R 15 ST 35
from 540 to 550 2 PAF-R 16 ST 45 from 490 to 500 1 PAF-R 16 ST 35
from 550 to 570 2 PAF-R 17 ST 45 from 500 to 510 1 PAF-R 16 ST 45
from 570 to 580 2 PAF-R 17 ST 60 from 510 to 520 1 ST 10 16 ST 50
from 580 to 590 2 PAF-R 18 ST 50 from 520 to 530 2 PAF-R 18 ST 45
from 590 to 600 2 PAF-R 18 ST 60 from 530 to 540 2 PAF-R 19 ST 45
from 540 to 550 2 PAF-R 20 ST 45
from 550 to 560 2 PAF-R 21 ST 45
from 560 to 570 2 PAF-R 22 ST 45
AcM : Anti crack Mesh from 570 to 580 2 PAF-R 23 ST 45
TB : Top Bars from 580 to 590 2 PAF-R 25 ST 45
from 590 to 600 2 PAF-R 26 ST 45

2 continuous bays
L L
q = 5,00 kN/m2 e = 0,75 mm q = 8,00 kN/m2 e = 0,75 mm
L Number AcM d TB L Number AcM d TB
(cm) of props (cm) (cm) of props (cm)
Up to 250 0 PAF-R 10 PAF-R Up to 210 0 PAF-R 10 ST 10
from 250 to 270 0 PAF-R 10 ST 10 from 210 to 240 0 PAF-R 10 ST 20
from 270 to 310 0 PAF-R 10 ST 20 from 240 to 250 0 PAF-R 10 ST 25
from 310 to 340 0 PAF-R 10 ST 25 from 250 to 260 0 ST 10 10 ST 20
from 340 to 350 1 PAF-R 12 ST 30 from 260 to 270 0 PAF-R 11 ST 25
from 350 to 360 1 PAF-R 12 ST 35 from 270 to 280 0 ST 10 11 ST 20
from 360 to 380 1 PAF-R 13 ST 35 from 280 to 290 0 PAF-R 12 ST 25
from 380 to 400 1 PAF-R 14 ST 35 from 290 to 310 0 PAF-R 13 ST 25
from 400 to 420 1 PAF-R 15 ST 35 from 310 to 320 1 PAF-R 15 ST 25
from 420 to 440 1 PAF-R 16 ST 35 from 320 to 330 1 PAF-R 16 ST 25
from 440 to 450 1 PAF-R 17 ST 35 from 330 to 340 1 PAF-R 16 ST 30
from 450 to 470 1 PAF-R 18 ST 35 from 340 to 350 1 PAF-R 17 ST 30
from 470 to 480 1 PAF-R 19 ST 35 from 350 to 360 1 PAF-R 18 ST 30
from 480 to 490 2 PAF-R 22 ST 35 from 360 to 370 1 PAF-R 19 ST 30
from 490 to 500 2 PAF-R 23 ST 35 from 370 to 380 1 PAF-R 19 ST 35
from 500 to 520 2 PAF-R 24 ST 35 from 380 to 390 1 PAF-R 20 ST 35
from 520 to 530 2 PAF-R 25 ST 35 from 390 to 400 1 PAF-R 21 ST 35
from 530 to 540 2 PAF-R 26 ST 45 from 390 to 410 1 PAF-R 22 ST 35
from 540 to 550 2 PAF-R 28 ST 35 from 410 v 420 1 PAF-R 23 ST 35
from 420 to 430 2 PAF-R 26 ST 35

Basis of table from 430 to 440 2 PAF-R 27 ST 35

q = imposed load from 440 to 450 2 PAF-R 28 ST 35

q = q1 + g1
q1 = imposed live load Complementary assumptions :
g1 = imposed permanent load
(partition wall, floor covering, suspended ceilings) taken • Normal weight concrete 2400 daN/m3
into account as operating loads. L
• Deflection at laying stage =
e.g. : L = 3,80 m 240
q1 = 1,50 kN/m2 L
g1 = 1,00 kN/m2 • Active deflection in service =
350
Consult the table : q = 2,50 kN/m2. • Shrinkage = 4 x 10-4
11 = slab depth d
PAF-R 11 ST 25 • Covering of top bars = 20 mm
PAF-R = Anti Crack Mesh
ST 25 = Top Bars (Mesh) • Top Bars : yield point 500 MPa
8
Arval Composite floor decks
Cofraplus 60

MAXIMUM APPLIED LOADF TABLES in daN/m2 with details :


- Of the number of props in construction stage,
- Of the maximum and minimum value of the total section of the steel mesh reinforcement to be provided to the upper part of
the slab with a covering of 20 mm,

2 continuous bays e = 0,75 mm


L L
Smini (cm2/m) 2,69 2,69 3,08 3,76 3,76 3,76 3,76 3,76 3,76 3,76 3,76 4,02 4,02 5,04 5,04 5,04 5,04 5,04 5,04 5,04 5,04
Smax (cm2/m) 3,76 3,76 3,76 3,76 4,02 4,02 4,02 4,02 5,04 5,04 5,04 5,04 5,04 5,04 5,04 5,43 5,43 5,43 6,22 6,22 6,22
Thickness Span L in cm
Slab in mm 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400
280 3000 3000 3000 3000 2970 2760 2570 2400 2250 2110 1990 1880 1770 1680 1590 1510 1430 1410 1340 1280 1130
270 3000 3000 3000 3000 2850 2650 2470 2310 2160 2030 1910 1800 1700 1610 1520 1450 1370 1350 1280 1220 1130
260 3000 3000 3000 2950 2730 2540 2370 2210 2070 1950 1830 1730 1630 1540 1460 1390 1320 1290 1230 1170 1120
250 3000 3000 3000 2950 2620 2430 2270 2120 1990 1870 1750 1650 1560 1480 1400 1330 1260 1240 1180 1120 1070
240 3000 3000 3000 2900 2500 2330 2170 2030 1900 1780 1680 1580 1490 1410 1340 1270 1200 1180 1130 1070 1020
230 3000 3000 2980 2770 2500 2220 2070 1930 1810 1700 1600 1510 1420 1350 1270 1210 1150 1130 1070 1020 980
220 3000 2970 2840 2630 2450 2110 1970 1840 1720 1620 1520 1430 1350 1280 1210 1150 1090 1070 1020 970 930
210 3000 2820 2690 2500 2330 2110 1870 1740 1630 1530 1440 1360 1280 1210 1150 1090 1030 1010 970 920 880
200 3000 2670 2550 2370 2200 2060 1870 1650 1550 1450 1360 1290 1210 1150 1090 1030 980 960 910 870 830
190 2830 2520 2410 2230 2080 1940 1770 1560 1460 1370 1290 1210 1140 1080 1020 970 920 900 860 820 780
180 2650 2370 2260 2100 1950 1830 1660 1560 1370 1290 1210 1140 1080 1020 960 910 870 840 810 770 740
170 2490 2220 2120 1970 1830 1710 1550 1460 1370 1200 1130 1070 1010 950 900 850 810 780 760 720 690
160 2330 2070 1980 1830 1710 1590 1450 1360 1320 1200 1060 990 940 890 840 800 760 730 710 670 640
150 2150 1920 1830 1700 1580 1480 1340 1260 1220 1160 1060 920 870 820 780 740 700 670 650 620 590
140 1990 1770 1690 1570 1460 1360 1240 1160 1130 1060 1010 920 800 760 720 680 640 610 600 570 550
130 1780 1620 1550 1440 1340 1250 1130 1060 1030 970 920 850 800 690 660 620 590 560 550 520 500
120 1590 1480 1410 1310 1210 1130 1030 960 940 880 840 770 730 690 590 560 530 510 500 480 450
110 1400 1320 1250 1180 1090 1020 920 870 840 790 750 690 650 540 590 510 480 460 440 420
100 1200 1140 1080 1020 970 910 820 770 750 700 660 610 580 570 540 510 480

2 continuous bays e = 0,75 mm


L L
Smini (cm2/m) 5,04 5,04 5,04 5,04 5,43 5,43 5,83 5,83 5,83 5,83 5,83 5,83 5,83 5,83 5,83 5,83 5,83 6,16 6,16 6,16 6,16
Smax (cm2/m) 6,22 6,22 6,22 6,22 6,22 6,22 6,22 6,22 6,22 6,55 6,22 6,22 6,16 6,16 6,16 6,16 6,16 6,16 6,16 6,16 6,16
Thickness Span L in cm
Slab in mm 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600 610
280 1070 1020 970 930 890 850 810 770 740 710 680 640 610 570 540 510 470 450 420 370 340
270 1030 980 930 890 850 810 780 740 710 680 650 620 580 550 520 490 470 440 420 370 330
260 1030 940 890 850 810 780 740 710 680 650 620 590 560 530 500 480 450 430 400 370 330
250 1020 900 860 820 780 740 710 680 650 620 590 570 540 510 480 460 430 410 390 360 330
240 980 900 820 780 740 710 680 650 620 590 570 540 520 490 460 440 410 390 370 350 330
230 930 890 820 740 710 680 650 620 590 560 540 520 490 470 440 420 400 370 350 330 320
220 890 850 810 740 670 640 610 590 560 540 510 490 470 450 420 400 380 360 340 320 300
210 840 800 770 730 670 610 580 560 530 510 490 470 450 420 400 380 360 340 320 300 290
200 790 760 730 690 660 610 550 530 500 480 460 440 420 400 380 360 340 320 310 290 270
190 750 710 680 650 630 600 550 530 470 450 430 410 400 380 360 340 320 310 290 270 260
180 700 670 640 610 590 560 540 520 470 430 410 390 370 360 340 320 310 290 270 260 230
170 660 630 600 570 550 530 510 480 470 430 380 360 350 330 320 300 280 250 230 200 180
160 610 580 560 530 510 490 470 450 430 420 380 350 320 290 270 240 220
150 570 540 520 490 470 450 440 420 380 340 310 280 250 230
140 520 500 480 460 440 410 370 330 300 270
130 480 450 430 400 360 320
120 430 390 340
110
100

no props 1 line of props during laying 2 lines of props during laying 3 lines of props during laying

Hypotheses used :
- Equal spans, - Deflection during laying = L/240,
- Distributed live load, - Active deflection in service = L/350 if L ≤ 350 cm and
- Permanent load nil, L/700 + 0,5 cm if L > 350 cm,
- Normal weight concrete 2400 daN/m3, - Réduction of maximum moment on support = 15 %.
- Steel reinforcement : yield point 500 MPa,

Nota : for all other assumptions, further calculations must be carried out.

9
Arval Composite floor decks
Cofraplus 60

MESH REINFORCEMENT, SLAB DEPTH AND PROPPING REQUIREMENTS UNDER TYPICAL APPLIED LOADS
These tables apply to simple cases where there are distributed loads and equal spans.
Using the Cofra 4 software, our technical team can carry out composite floor deck studies in the shortest possible time.

2 rebated spans
L L
q = 2,50 kN/m2 e = 0,75 mm q = 3,50 kN/m2 e = 0,75 mm
L Number AcM d TB L Number AcM d TB
(cm) of props (cm) (cm) of props (cm)
Up to 270 0 PAF-R 10 PAF-R Up to 270 0 PAF-R 10 PAF-R
from 270 to 280 1 PAF-R 10 PAF-R from 270 to 280 1 PAF-R 10 ST 10
from 280 to 310 1 PAF-R 10 ST 10 from 280 to 310 1 PAF-R 10 ST 20
from 310 to 350 1 PAF-R 10 ST 20 from 310 to 340 1 PAF-R 10 ST 25
from 350 to 360 1 PAF-R 10 ST 25 from 340 to 350 1 PAF-R 10 ST 30
from 360 to 370 1 PAF-R 11 ST 20 from 350 to 360 1 PAF-R 10 ST 35
from 370 to 390 1 PAF-R 11 ST 25 from 360 to 370 1 PAF-R 11 ST 30
from 390 to 420 1 PAF-R 12 ST 25 from 370 to 390 1 PAF-R 11 ST 35
from 420 to 430 1 PAF-R 12 ST 30 from 390 to 420 1 PAF-R 12 ST 35
from 430 to 450 1 PAF-R 13 ST 30 from 420 to 440 1 PAF-R 13 ST 35
from 450 to 460 1 PAF-R 13 ST 35 from 440 to 460 1 PAF-R 14 ST 35
from 460 to 490 1 PAF-R 14 ST 35 from 460 to 470 1 ST 10 14 ST 50
from 490 to 500 1 PAF-R 14 ST 50 from 470 to 480 1 PAF-R 15 ST 35
from 500 to 510 1 PAF-R 15 ST 35 from 480 to 490 1 ST 10 15 ST 50
from 510 to 520 1 PAF-R 15 ST 50 from 490 to 500 1 PAF-R 16 ST 45
from 520 to 530 2 PAF-R 16 ST 35 from 500 to 510 1 ST 10 16 ST 50
from 530 to 540 2 PAF-R 16 ST 45 from 510 to 520 2 PAF-R 18 ST 45
from 540 to 550 2 PAF-R 16 ST 60 from 520 to 530 2 PAF-R 18 ST 45
from 550 to 560 2 PAF-R 17 ST 45 from 530 to 540 2 PAF-R 19 ST 45
from 560 to 570 2 PAF-R 17 ST 50 from 540 to 550 2 PAF-R 20 ST 45
from 570 to 590 2 PAF-R 18 ST 50 from 550 to 560 2 PAF-R 21 ST 45
from 590 to 600 2 PAF-R 18 ST 60 from 560 to 570 2 PAF-R 22 ST 50
from 570 to 580 2 PAF-R 24 ST 45
from 580 to 590 2 PAF-R 25 ST 45
AcM : Anti crack Mesh
from 590 to 600 2 PAF-R 27 ST 45
TB : Top Bars

2 rebated span
L L
q = 5,00 kN/m2 e = 0,75 mm q = 8,00 kN/m2 e = 0,75 mm
L Number AcM d TB L Number AcM d TB
(cm) of props (cm) (cm) of props (cm)
Up to 250 0 PAF-R 10 PAF-R jusque 210 0 PAF-R 10 ST 10
from 250 to 270 0 PAF-R 10 ST 10 from 210 to 240 0 PAF-R 10 ST 20
from 270 to 300 1 PAF-R 10 ST 25 from 240 to 250 0 PAF-R 10 ST 25
from 300 to 310 1 PAF-R 10 ST 30 from 250 to 260 0 ST 10 10 ST 20
from 310 to 320 1 PAF-R 10 ST 35 from 260 to 280 1 PAF-R 12 ST 25
from 320 to 330 1 PAF-R 11 ST 30 from 280 to 290 1 PAF-R 13 ST 25
from 330 to 340 1 PAF-R 11 ST 35 from 290 to 300 1 PAF-R 14 ST 25
from 340 to 360 1 PAF-R 12 ST 35 from 300 to 310 1 PAF-R 14 ST 30
from 360 to 380 1 PAF-R 13 ST 35 from 310 to 320 1 PAF-R 15 ST 30
from 380 to 390 1 PAF-R 14 ST 35 from 320 to 330 1 PAF-R 16 ST 30
from 390 to 410 1 PAF-R 15 ST 35 from 330 to 340 1 PAF-R 16 ST 35
from 410 to 430 1 PAF-R 16 ST 35 from 340 to 350 1 PAF-R 17 ST 35
from 430 to 440 1 PAF-R 17 ST 35 from 350 to 360 1 PAF-R 18 ST 35
from 440 to 460 1 PAF-R 18 ST 35 from 360 to 370 1 PAF-R 19 ST 35
from 460 to 470 1 PAF-R 19 ST 35 from 370 to 380 1 PAF-R 20 ST 35
from 470 to 480 2 PAF-R 21 ST 35 from 380 to 400 1 PAF-R 21 ST 35
from 480 to 490 2 PAF-R 22 ST 35 from 400 to 410 1 PAF-R 22 ST 35
from 490 to 500 2 PAF-R 23 ST 35 from 410 to 420 1 PAF-R 23 ST 35
from 500 to 510 2 PAF-R 24 ST 35 from 420 to 430 2 PAF-R 26 ST 35
from 510 to 520 2 PAF-R 24 ST 45 from 430 to 440 2 PAF-R 27 ST 35
from 520 to 530 2 PAF-R 25 ST 45 from 440 to 450 2 PAF-R 28 ST 35
from 530 to 540 2 PAF-R 27 ST 45
from 540 to 550 2 PAF-R 28 ST 45

Basis of table Complementary assumptions :


q = imposed load e.g. : L = 3,50 m • Normal weight concrete 2400 daN/m3
q = q1 + g1 q1 = 1,50 kN/m2 • Deflection at laying stage = L
q1 = imposed live load g1 = 1,00 kN/m2 240
g1 = imposed permanent load Consult the table : q = 2,50 kN/m2. • Active deflection in service = L
(partition wall, floor covering, 350
PAF-R 10 ST 20
10 = thickness of slab d • Shrinkage = 4 x 10-4
suspended ceilings) taken into PAF-R = Anti Crack Mesh • Covering of top bars = 20 mm
account as operating loads. ST 20 = Top Bars (Mesh) • Top Bars : yield point 500 MPa
10
Arval Composite floor decks
Cofraplus 60

MESH REINFORCEMENT, SLAB DEPTH AND PROPPING REQUIREMENTS UNDER TYPICAL APPLIED LOADS
These tables apply to simple cases where there are distributed loads and equal spans.
Using the Cofra 4 software, our technical team can carry out composite floor deck studies in the shortest possible time.

3 span system
L L L
q = 2,50 kN/m2 e = 0,75 mm q = 3,50 kN/m2 e = 0,75 mm
L Number AcM d TB L Number AcM d TB
(cm) of props (cm) (cm) of props (cm)
Up to 340 0 PAF-R 10 PAF-R Up to 310 0 PAF-R 10 PAF-R
from 340 to 360 1 ST 10 10 PAF-R from 310 to 330 0 PAF-R 10 ST 10
from 360 to 370 1 PAF-R 11 ST 20 from 330 to 340 0 ST 10 10 PAF-R
from 370 to 390 1 ST 10 11 ST 20 from 340 to 360 1 ST 20 10 PAF-R
from 390 to 430 1 ST 10 12 ST 20 from 360 to 370 1 ST 10 11 ST 20
from 430 to 450 1 ST 10 13 ST 20 from 370 to 380 1 ST 10 11 ST 25
from 450 to 460 1 ST 10 13 ST 25 from 380 to 390 1 ST 10 12 ST 20
from 460 to 480 1 ST 10 14 ST 25 from 390 to 400 1 ST 10 12 ST 25
from 480 to 500 1 ST 10 15 ST 25 from 400 to 410 1 ST 20 12 ST 25
from 410 to 420 1 ST 10 13 ST 25
from 420 to 430 1 ST 20 13 ST 20
from 430 to 440 1 ST 10 14 ST 25
from 440 to 450 1 ST 20 14 ST 20
from 450 to 460 1 ST 10 15 ST 25
from 460 to 470 1 ST 20 15 ST 20
from 470 to 480 1 ST 20 15 ST 35

AcM : Anti crack Mesh from 480 to 490 1 ST 20 16 ST 25

TB : Top Bars from 490 to 500 1 ST 20 16 ST 35

3 span system
L L L
q = 5,00 kN/m2 e = 0,75 mm q = 8,00 kN/m2 e = 0,75 mm
L Number AcM d TB L Number AcM d TB
(cm) of props (cm) (cm) of props (cm)
Up to 260 0 PAF-R 10 PAF-R Up to 200 0 PAF-R 10 PAF-R
from 260 to 280 0 ST 10 10 PAF-R from 200 to 220 0 ST 10 10 PAF-R
from 280 to 300 0 ST 10 10 ST 10 from 220 to 240 0 ST 10 10 ST 10
from 300 to 320 0 ST 10 10 ST 20 from 240 to 250 0 ST 20 10 PAF-R
from 320 to 340 0 ST 20 10 ST 10 from 250 to 260 0 ST 20 10 ST 10
from 340 to 360 1 ST 20 12 ST 20 from 260 to 270 0 ST 20 11 PAF-R
from 360 to 380 1 ST 20 13 ST 20 from 270 to 280 0 ST 20 11 ST 10
from 380 to 400 1 ST 20 14 ST 20 from 280 to 290 0 ST 20 12 PAF-R
from 400 to 410 1 ST 20 15 ST 20 from 290 to 300 0 ST 20 12 ST 10
from 410 to 420 1 ST 20 15 ST 25 from 300 to 310 0 ST 20 13 ST 10
from 420 to 430 1 ST 20 16 ST 20 from 310 to 320 1 ST 20 15 ST 10
from 430 to 440 1 ST 20 17 ST 20 from 320 to 330 1 ST 20 16 ST 10
from 440 to 450 1 ST 20 17 ST 25 from 330 to 340 1 ST 20 16 ST 20
from 450 to 470 1 ST 20 18 ST 25 from 340 to 350 1 ST 20 17 ST 20
from 470 to 480 1 ST 20 19 ST 25 from 350 to 360 1 ST 20 18 ST 20
from 480 to 490 2 ST 10 22 ST 30 from 360 to 380 1 ST 20 19 ST 20
from 490 to 500 2 ST 10 23 ST 30 from 380 to 390 1 ST 20 20 ST 20
from 390 to 400 1 ST 20 21 ST 20
from 400 to 410 1 ST 20 22 ST 20
Basis of table from 410 to 420 1 ST 20 23 ST 20
from 420 to 430 2 ST 10 26 ST 25
q = imposed load
from 430 to 440 2 ST 10 27 ST 25
q = q1 + g1
from 440 to 450 2 ST 10 28 ST 25
q1 = imposed live load
g1 = imposed permanent load
(partition wall, floor covering, suspended ceilings) taken Complementary assumptions :
into account as operating loads. • Normal weight concrete 2400 daN/m3
e.g. : L = 4,00 m
q1 = 1,50 kN/m2 • Deflection at laying stage = L
240
g1 = 1,00 kN/m2
• Active deflection in service = L
Consult the table : q = 2,50 kN/m2. 350
12 = slab depth d • Shrinkage = 4 x 10-4
ST 10 12 ST 20
ST 10 = Anti Crack Mesh • Covering of top bars = 20 mm
ST 20 = Top Bars (Mesh) • Top Bars : yield point 500 MPa

12
Arval Composite floor decks
Cofraplus 60

MAXIMUM APPLIED LOAD TABLES in daN/m2 with details :


- Of the number of props in construction stage,
- Of the maximum and minimum value of the total section of the steel mesh reinforcement to be provided to the upper part of
the slab with a covering of 20 mm,

2 rebated spans e = 0,75 mm


L L
Smini (cm2/m) 2,69 3,08 3,08 3,76 3,76 3,76 3,76 3,76 4,02 4,02 4,02 5,04 5,04 5,04 5,04 5,04 5,04 5,04 5,04 5,04 5,04
Smax (cm2/m) 3,76 3,76 3,76 3,76 4,02 5,04 5,04 5,04 5,04 5,04 5,04 5,04 5,04 5,04 5,43 5,43 6,22 6,22 6,22 6,22 6,22
Thickness Span L in cm
Slab in mm 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400
280 3000 3000 3000 3000 2940 2730 2540 2380 2230 2090 1960 1850 1740 1650 1570 1530 1450 1380 1310 1250 1120
270 3000 3000 3000 3000 2830 2620 2440 2280 2140 2010 1890 1780 1680 1580 1510 1470 1390 1320 1260 1200 1120
260 3000 3000 3000 2930 2710 2520 2340 2190 2050 1920 1810 1700 1610 1520 1440 1410 1340 1270 1210 1150 1090
250 3000 3000 3000 2800 2600 2410 2250 2100 1960 1840 1730 1630 1540 1450 1380 1350 1280 1210 1150 1100 1050
240 3000 3000 2900 2680 2480 2300 2150 2000 1880 1760 1650 1560 1470 1390 1320 1290 1220 1160 1100 1050 1000
230 3000 3000 2770 2560 2370 2200 2050 1910 1790 1680 1580 1480 1400 1320 1250 1230 1160 1100 1050 1000 950
220 3000 2870 2640 2430 2250 2090 1950 1820 1700 1600 1500 1410 1330 1260 1190 1170 1110 1050 1000 950 910
210 3000 2720 2500 2310 2140 1980 1850 1730 1610 1510 1420 1340 1260 1190 1130 1110 1050 1000 950 900 860
200 3000 2580 2370 2190 2020 1880 1750 1630 1530 1430 1350 1270 1200 1130 1070 1050 990 940 900 850 810
190 2830 2520 2240 2060 1910 1770 1650 1540 1440 1350 1270 1200 1130 1060 1010 990 940 890 840 800 770
180 2650 2370 2100 1940 1800 1670 1550 1450 1350 1270 1190 1120 1060 1000 950 930 880 830 790 750 720
170 2490 2220 2100 1820 1680 1560 1450 1360 1270 1190 1120 1050 990 940 890 870 820 780 740 710 670
160 2330 2070 1980 1700 1570 1460 1350 1260 1180 1110 1040 980 920 870 820 810 770 730 690 660 630
150 2150 1920 1830 1700 1460 1350 1260 1170 1100 1030 970 910 860 810 760 750 710 670 640 610 580
140 1990 1770 1690 1570 1340 1250 1160 1080 1010 950 890 840 790 740 700 680 650 620 590 560 530
130 1780 1620 1550 1440 1340 1140 1060 990 930 870 810 770 720 680 640 620 600 570 540 510 490
120 1590 1480 1410 1310 1210 1130 970 900 840 790 740 700 660 620 580 560 540 520 490 470 440
110 1400 1320 1250 1180 1090 1020 920 810 760 710 670 630 590 560 530 500 490 460 430 400
100 1200 1140 1080 1020 970 910 820 770 670 630 590 550 500 470 430 400 370

2 rebated spans e = 0,75 mm


L L
Smini (cm2/m) 5,04 5,04 5,04 5,43 5,83 5,83 5,83 5,83 5,83 5,83 5,83 5,83 5,83 5,83 6,16 6,16 6,16 6,16 6,16 6,16 6,16
Smax (cm2/m) 6,22 6,22 6,22 6,22 6,22 6,22 6,22 6,22 6,55 6,55 6,55 6,16 6,16 6,16 6,16 6,16 6,16 6,16 6,16 6,16 6,16
Thickness Span L in cm
Slab in mm 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600 610
280 1070 1010 970 920 880 840 800 770 730 700 670 630 600 570 540 510 470 440 420 360 340
270 1020 970 930 880 840 810 770 730 700 670 640 610 580 550 520 490 460 440 410 360 330
260 1020 930 890 850 810 770 740 700 670 640 620 590 550 520 500 470 440 420 400 360 330
250 1000 890 850 810 770 740 710 670 640 620 590 560 530 500 480 450 430 400 380 360 330
240 950 890 810 770 740 700 670 640 610 590 560 540 510 480 460 430 410 390 360 340 320
230 910 870 810 740 700 670 640 610 590 560 540 510 490 460 440 410 390 370 350 330 310
220 860 820 790 740 670 640 610 580 560 530 510 490 470 440 420 390 370 350 330 310 300
210 820 780 750 710 670 610 580 550 530 500 480 460 440 420 400 380 360 340 320 300 280
200 770 740 710 670 650 610 550 520 500 480 460 440 420 400 380 360 340 320 300 290 270
190 730 700 670 640 610 580 550 520 470 450 430 410 390 380 360 340 320 300 290 270 260
180 690 650 620 600 570 550 520 500 470 420 400 390 370 350 340 320 300 290 270 250 230
170 640 610 580 560 530 510 490 470 450 420 380 360 340 330 320 300 270 240 220 200 180
160 600 570 540 520 500 480 450 440 420 400 370 330 320 290 260 230 210
150 550 530 500 480 460 440 420 400 360 320 290 260 230 210
140 510 490 460 440 420 390 350 320 280 250
130 470 440 420 380 340 310
120 420 370 330
110
100

no props 1 line of props during laying 2 lines of props during laying 3 lines of props during laying

Hypotheses used :
- Equal spans, - Deflection during laying = L/240,
- Distributed live load, - Active deflection in service = L/350 if L ≤ 350 cm and
- Permanent load nil, L/700 + 0,5 cm if L > 350 cm,
- Normal weight concrete 2400 daN/m3, - Réduction of maximum moment on support = 15 %.
- Steel reinforcement : yield point 500 MPa,

Nota : for all other assumptions, further calculations must be carried out.

11
Arval Composite floor decks
Cofraplus 60

MAXIMUM APPLIED LOAD TABLES in daN/m2 with details :


- Of the number of props in construction stage,
- Of the maximum and minimum value of the total section of the steel mesh reinforcement to be provided to the upper part of
the slab with a covering of 20 mm,

3 span system e = 0,75 mm


L L L
Smini (cm2/m) 2,38 2,38 2,69 3,08 3,08 3,08 3,78 3,78 3,78 3,78 3,78 3,78 3,76 3,76 4,46 3,78 3,78 4,46 4,46 4,46 4,46
Smax (cm2/m) 3,08 3,78 3,78 3,78 3,78 3,78 3,78 3,78 3,78 4,46 4,46 4,46 4,46 4,46 4,46 4,46 4,46 5,14 5,14 5,14 5,14
Thickness Span L in cm
Slab in mm 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400
280 3000 3000 3000 3000 2980 2770 2580 2410 2260 2120 1990 1880 1770 1680 1590 1500 1430 1360 1330 1270 1120
270 3000 3000 3000 3000 2860 2660 2480 2320 2170 2040 1910 1800 1700 1610 1520 1440 1370 1300 1280 1220 1120
260 3000 3000 3000 2960 2750 2550 2380 2220 2080 1950 1840 1730 1630 1540 1460 1390 1310 1250 1230 1170 1120
250 3000 3000 3000 2960 2630 2440 2280 2130 1990 1870 1760 1660 1560 1480 1400 1330 1260 1200 1170 1120 1070
240 3000 3000 3000 2930 2510 2330 2180 2030 1900 1790 1680 1580 1490 1410 1340 1270 1200 1140 1120 1070 1020
230 3000 3000 3000 2790 2510 2230 2070 1940 1810 1700 1600 1510 1420 1340 1270 1210 1150 1090 1070 1020 970
220 3000 3000 2870 2660 2480 2120 1970 1840 1730 1620 1520 1430 1350 1280 1210 1150 1090 1040 1010 970 920
210 3000 2940 2720 2520 2350 2120 1870 1750 1640 1540 1440 1360 1280 1210 1150 1090 1030 980 960 920 880
200 3000 2780 2570 2390 2220 2080 1870 1660 1550 1450 1370 1290 1210 1150 1090 1030 980 930 900 870 830
190 2860 2630 2430 2250 2100 1960 1840 1560 1460 1370 1290 1210 1150 1080 1020 970 920 870 850 820 780
180 2690 2470 2280 2120 1970 1840 1730 1560 1370 1290 1210 1140 1080 1020 960 910 870 820 800 770 730
170 2520 2320 2140 1990 1850 1730 1620 1520 1370 1210 1130 1070 1010 950 900 850 810 770 740 720 690
160 2350 2160 2000 1850 1720 1610 1510 1420 1330 1130 1060 1000 940 890 840 790 750 720 690 670 640
150 2180 2000 1850 1720 1600 1490 1400 1310 1240 1130 980 920 870 820 780 740 700 660 630 620 590
140 1990 1850 1710 1580 1470 1380 1290 1210 1110 1070 980 850 800 760 720 680 640 610 580 570 540
130 1790 1690 1570 1450 1350 1260 1180 1110 1040 980 930 850 740 690 650 620 590 560 530 520 500
120 1590 1510 1420 1320 1230 1140 1070 1000 950 890 840 800 740 630 600 560 530 510 480 460 410
110 1400 1320 1250 1190 1100 1030 960 900 850 800 760 720 680 630 540 510 480 450 390 340
100 1200 1140 1080 1020 970 910 850 800 750 710 670 640 600 570 540 420 360

3 span system e = 0,75 mm


L L L
Smini (cm2/m) 4,46 4,46 4,46 4,46 4,46 4,46 4,46 4,46 4,46 4,46
Smax (cm2/m) 5,14 5,14 5,14 5,74 5,74 5,74 5,74 5,74 5,74 5,74
Thickness Span L in cm
Slab in mm 410 420 430 440 450 460 470 480 490 500
280 1070 1020 970 920 880 840 800 770 730 700
270 1030 980 930 890 840 810 770 730 700 670
260 1030 940 890 850 810 770 740 700 670 640
250 1020 900 850 810 770 740 710 670 640 620
240 970 900 810 780 740 710 670 640 610 590
230 930 890 810 740 700 670 640 610 590 560
220 880 840 800 740 670 640 610 580 560 530
210 840 800 760 730 670 610 580 550 530 500
200 790 750 720 690 660 610 550 520 500 480 Length greater than 15 metres.
190 740 710 680 650 620 600 550 520 470 450
180 700 670 340 610 580 560 540 510 470 420
170 650 620 600 570 550 520 500 480 460 430
160 610 580 560 530 510 490 470 430 390 350
150 560 540 510 490 470 430 390 350 310 280
140 520 500 470 420 380 340 300 270 240 210
130 470 420 370 330 290 260
120 360 320 280
110
100

no props 1 line of props during laying 2 lines of props during laying 3 lines of props during laying

Hypotheses used :
- Equal spans, - Deflection during laying = L/240,
- Distributed live load, - Active deflection in service = L/350 if L ≤ 350 cm and
- Permanent load nil, L/700 + 0,5 cm if L > 350 cm,
- Normal weight concrete 2400 daN/m3, - Réduction of maximum moment on support = 15 %.
- Steel reinforcement : yield point 500 MPa,

Nota : for all other assumptions, further calculations must be carried out.

13
Arval Composite floor decks
Cofraplus 60

ADDITIONAL SERVICES
Cofraplus 60 P (prepunched) : the permissible performance in the construction phase must be checked by our technical
assistance department.
Specific design notes established by the Cofra 4 software.

Formwork for edges Openings


The formwork for the edges is made up of galvanised steel • Space reserved for small openings
edging trims bent at right angles. (50 x 50 cm maximum)
Common lengths 2 to 4 metres. Openings can be formed before pouring the concrete with
preformed edge trims manufactured and assembled to the
Floor thickness d Minimum plating thickness
in mm in mm required dimensions.
≤ 110 1,20
from 120 to 140 1,50
≥ 150 2,00 • Larger openings
A system made up of transverse and longitudinal edging and
If necessary (slab depth > 15 cm) restraint straps must be support brackets can be used.
provided on the site. This system incorporated into the slab, can served as a
trimming to reinforce the slab around the opening.
d d

6 cm mini. 6 cm mini.

• Foam closures : see drawing below.


- thickness 40 mm
- length 1035 mm
- adhesive part

Adhesive

1035

Section S E D Number Length Nominal Surfac Mass


Designation S s e d of wires width mass 1 roll 1 panel
N L or
ADETS l 1 panel
cm2/m cm2/m mm mm m kg/m2 m2 kg
0,80 200 4,5 12 3,60
PAF-R 0,80 0,53 300 4,5 12 2,40 1,042 8,64 9,00
1,19 200 5,5 12 4,80
ST 10 1,19 1,19 200 5,5 24 2,40 1,870 11,52 21,54
1,89 150 6 16 6,00
ST 20 1,89 1,28 300 7 20 2,40 2,487 14,40 35,81
2,57 150 7 16 6,00
ST 25 2,57 1,28 300 7 20 2,40 3,020 14,40 43,49
2,83 100 6 24 6,00
ST 30 2,83 1,28 300 7 20 2,40 3,326 14,40 46,46
3,85 100 7 24 6,00
ST 35 3,85 1,28 300 7 20 2,40 4,026 14,40 57,98
4,24 150 9 16 6,00
ST 45 4,24 1,68 300 8 20 2,40 4,643 14,40 66,86
5,03 100 8 24 6,00
ST 50 5,03 1,68 300 8 20 2,40 5,267 14,40 75,84
6,36 100 9 24 6,00
ST 60 6,36 2,51 200 8 30 2,40 6,965 14,40 100,30
7,70 100 7 24 6,00
2 x ST 35 7,70 2,56 300 7 20 2,40 8,052 14,40 57,98
8,48 150 9 16 6,00
2 x ST 45 8,48 3,32 300 8 20 2,40 9,286 14,40 66,86
10,06 100 8 24 6,00
2 x ST 50 10,06 3,36 300 8 20 2,40 10,534 14,40 75,84
12,72 100 9 24 6,00
2 x ST 60 12,72 5,02 200 8 30 2,40 13,930 14,40 100,30

14
Arval Composite floor decks
Cofraplus 60

Date :

QUESTIONNAIRE

YOUR CONTACT DETAILS


Company :

Applicant : Mrs, Mr.

Site : Surface /Area :

Telephone : Fax :

E-mail address :

SPAN : YOUR CASE


2 supports l l: m
3 supports l1 l2 l1: m l2: m
4 supports l1 l2 l3 l1: m l2: m l3: m
• Imposed load : kN/m2
• Permanent load : kN/m2 (excluding self-weight of floor)
• Total thickness of floor required : mm
• Possibility of props during laying Yes No
• Fire resistance
• For all other load cases, enclose a detailed drawing.

ARVAL EXPORT DEPARTMENT - Tel. +33 3 29 78 85 42 - Fax +33 3 29 79 84 23