OPERATOR MANUAL
CONTENTS
1. SYSTEM DESCRIPTION 5
1.1. Front side 5
1.2. keys functioning 5
1.2.1. PN Normal mode : normal pushing of a key. 5
1.2.2. PT temporized mode: pushing of a key for about two seconds . 5
1.3. Led Function 5
2. setting and selection 6
2.1. numerical setting method 6
2.2. selection method 6
2.3. password setting methode 6
3. Set Point 7
3.1. Visualisation 7
3.2. setting 7
4. set point configuration 8
4.1. Standard configuration sequence 8
4.2. Standard confguration methode 9
4.2.1. Contact normally open/ normally closed 9
4.2.2. Contact active positive/ negative / bipolar 9
4.2.3. Active contact on gross / net weight 10
4.2.4. relè intervention delay 10
4.2.5. normal contact / with hysteresis 10
4.3. Special configuration 10
4.3.1. Contacts always active / active with stable weight 10
4.3.2. Active / non active selecting function 11
5. peak function 11
5.1. positive peak activation 11
5.2. negative peak activation 11
5.3. Deletion of the peak value 12
5.4. Deactivation of the peak function 12
5.5. blocked peak function 12
5.6. released peak function 12
6. hold function 12
6.1. hold function activation 13
6.2. hold value delete 13
6.3. Deactivation of the hold function 13
6.4. Blocked hold function 13
6.5. Released hold function 13
7. Zero functions 13
7.1. Autotare or temporary zeroing 14
7.2. Memorised zeroing of the weight 14
8. Weighing calibration 14
8.1. Division value 14
8.2. Calibration 15
page 2 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
page 3 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
19. Connections 33
page 4 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
1. SYSTEM DESCRIPTION
11..11.. F
FRRO
ONNT
T SSIID
DEE
11..22.. K
KEEY
YSS FFU
UNNC
CTTIIO
ONNIIN
NGG
Each key can be pushed in two modes as follows:
1.2.1. PN NORMAL MODE : NORMAL PUSHING OF A KEY.
This way the most direct functions of use are accessed.
1.2.2. PT TEMPORIZED MODE: PUSHING OF A KEY FOR ABOUT TWO SECONDS .
The second-level functions are managed this way (setting and selection).
page 5 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
push and release in quick succession the Mode key, and the Zero key
visualises C00000 ,access code setting. By pushing the Mode key (pn)
with C00000 visualised, the weighing restarts.
set the code number by means of the arrow keys and push , if the code
is correct then the parameter setting will be accessed (if wrong push C
and write it again).
page 6 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
3. SEETTPO
OIIN
NTT
33..11.. V
VIISSU
UAAL
LIISSA
ATTIIO
ONN
33..22.. SSE
ETTT
TIIN
NGG
Push the key Set (pt) to visualise and modify the set point.
it is shown A ProG for about two seconds than the memorised set value
A which can be modified (see setting ).
A = set of loaded weight which commutes the relè output 1.
Push to go on without entering the setting.
page 7 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
it is shown b ProG for about two seconds than the memorised set value
b which can be modified (see setting ).
b = set of loaded weight which commutes the relè output 2.
Push to go on without entering the setting.
it shows c ProG for about two seconds than the memorised set value
set c which can be modified (see setting).
c = set of loaded weight which commutes the relè output 3
. Push to go on without entering the setting
it shows d ProG for about two seconds than the memorised set value
set d which can be modified (see setting).
4. ET
SSE TP
POOIIN
NTTC
COON
NFFIIG
GU RA
UR AT
TIIO
ONN
44..11.. SSTTAAN
NDDA
AR DC
RD CO
ONNFFIIG
GUUR
RAAT
TIIO
ONN SSE
EQQU
UE NC
EN CE
E
it shows b conF .
Push to terminate.
44..22.. SSTTAAN
NDDA
ARRD
DCCO
ONNFFG
GUUR
RAAT
TIIO
ONNM
MEET
THHO
ODDE
E
page 9 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
With active selecting function the sets must be set so that the following
one is always higher then the previous one; just one set each time will be
activate . For example: set1/10kg set2/100kg set3/200kg set4/300kg
relè1 active between 10kg and 100kg /relè2 between 100 and 200kg
/relè3 between 200 and 300kg /relè4 above 400kg.
vis. MEMOr (2 sec.) than restarts weighing
5. P
PEEA
AKKF
FUUN
NCCT
TIIO
ONN
The peak function (if available) allows the visualisation of the maximum value
reached by the display to be blocked. A zeroing control range is foreseen and within
it the peak function is not active. When the weight is out of the zero control, the
instrument keeps the highest, recent weight value memorised.
It is possible to state to keep such a value up to the zero control range reached
(released), or up to the F2 key is pushed F2 (blocked).
Input 3: it activates the peak function (if peak instrument option available).
Input 4: it deactivates the peak function (if peak instrument option available).
55..11.. PPO
OSSIIT VE
TIIV E PPE
EAAK
KAAC
CTTIIV
VAAT ON
TIIO N
Memorisation of the peak value is carried out with positive signal only.
Memorisation of the peak value is carried out with negative signal only
page 11 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
55..33.. D
DEELLEETTIIO
ONNO
OFF T
THHE
E PPE
EAAK
KVVA
ALLU
UEE
55..44.. D
DEEAACCTTIIVVAATTIIO
ONNO
OFF T
THHE
E PPE
EAAK
K FFU
UNNC
CTTIIO
ONN
The peak value is defined as blocked when it must be deleted with the
F2(PN) key.
6. H
HOOL
LDDF
FUUN
NCCT
TIIO
ONN
The hold function (if available) allows to keep blocked the visualisation of the value
reached by the display in the stable weight condition A zeroing control range is
foreseen and within it the peak function is not active. It is possible to state to keep
such a value up to the zero control range reached (released), or up to the F2 key is
pushed F3 (blocked).
Use 1: push hold with weight zero. When reaching a stable weight after loading, the
data has to be memorised.
Use 2: after loading push hold, when reaching a stable weight the data will be
page 12 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
The hold value is considered blocked when it must be deleted with the
F2(pn) key.
7. ZEERRO
OFFU
UNNC
CTTIIO
ONNSS
page 13 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
77..11.. A
AUUT
TOOT
TAAR
REEO
ORRT
TEEM
MPPO
ORRA
ARRY
YZZE
ERRO
OIIN
NGG
It allows the manual temporary zeroing of the weight (autotare)
push the Z (PN) key to make the zeroing of the weight (the same effect
can be obtained with the input 4)
77..22.. M
MEEM
MOOR
RIISSE
EDDZ
ZEER
ROOIIN
NGGO
OFF T
THHE
EWWE
EIIG
GHHT
T
It allows the permanent zeroing of the weighing system (the
same effect is obtained even with the input 3)
8. WEEIIGGH
HIIN
NGGC
CAAL
LIIB
BRRA
ATTIIO
ONN
Use the PASSWORD setting method
88..11.. D
DIIVVIISSIIO
ONNV
VAAL
LUUE
E
The display shows Unit for about 3 seconds and then shows the actual
value of the weight unit.
The minimum weight unit, also defined as "metric weight unit", is the
smallest weight change readable on the display and reèresents the
instrument sensibility. This information is essential to make the reading
on the display corresponding to the real weight.
The display shows d nnn where nnn can correspond to:
1/2/5 10/20/50 100/200/500
0,1/0,2/0,5 0,01 / 0,02 / 0,05 0,10 / 0,20 / 0,50
0,001/0,002/0,005 0,010/0,020/0,050 0,100/0,200/0,500
key to increase the visualised value as in the row without the comma.
page 14 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
key to decrease the visualised value as in the row without the comma.
key ⊳ to move the comma position to the leaft one place each time.
key to accept the value and proceede
88..22.. C
CAALLIIBBRRAATTIIO
ONN
shows CALIbr for about 3 seconds and then shows the actual weight
value as reading of the balance. This value is a number depending on the
weight and on the division value as above described, but not
corresponding to a real weight.
The calibration is an operation that allows the zero of the balance to
correspond to the visualised zero and the load weight to the reading on
the display.
shows t nnnn where nnnn represents the reading from the load cells.
8.2.1. ZERO CALIBRATION
It is needed to remove the tare value of the loading on the load cells
(plate of the balance, hopper and various accessories. In practice all the
constant loads must be annulled in order to have net weights.
on the balance has not to be present other weights except these
constant loads.
page 15 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
after the confirmation the display shows Calibr for 3 seconds and then the
calibrated weight is shown.
the displayed weight has to be corresponding to the weight effectively
loaded on the balance. If an error has been done and the weight does not
corresponds then the operation has to be repeated by pushing the key
again
N.B. If the instrument shown the “ERR DIV” error something is wrong in division value or the
connected sensor doesn’t work correctly (Wrong wiring, Mechanical bond, etc).
If the error persist try, in calibration function (CAL) pressing in succession th key SET-F1 and
ENTER, then retry to calibrate.
page 16 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
88..33.. CCAALLIIBBRRAATTIIO
ONNR
REESSE
ETT ((C
COOD
DEE 0000555555))
C00555 write the code C00555 press Mode (pn) to confirm it.
dAti It displays data for 3 sec. Then shows the first value.
where X is related to gravity correction and can be 0 – 1 – 2 .
Xnnnnn 0 = gravity correction not set (no relative data displayed)
1 = gravity correction with one set value (one value displayed)
2 = gravity correction with two set values (two values displayed)
PRIMO DATO
FIRST VALUE 0 1 2
GRAV-1
GRAV-2
ZERO
1-SPAN
2-SPAN
page 17 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
88..44.. F
FIIRRSSTT AAU
UTTO
OMMA
ATTIIC
CCCA
ALLIIB
BRRA
ATTIIO
ONN ((C
CO D..0044000000))
OD
Warning: this calibration mode does not allow the same accuracy as that
of the previous paragraphs. It is only used in cases when a sample weight
cannot be loaded or when tanks are already full and cannot be emptied.
Use the PASSWORD setting mode (paragraph Errore. L'origine
riferimento non è stata trovata.)
C04000 Write the code C04000 press Mode (pn) to confirm it.
8.4.1. CELL FULL SCALE
FS CEL is displayed for about 2 seconds, then the following text will appear:
which matches the previously set full-scale value. Using the setting
Fxxxxx method, write the total capacity of all of the cells.
page 18 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
Monopolar is used any time there is a tare on the cells and a traditional
weighing session is performed. Bipolar is used when there is no tare and
either a positive or a negative load can be read.
10. C
COON
NVVE
ERRT
TE R’SS E
ER ERRR
ROOR
RSS
The converter’s reception errors are displayed as follows:
OVEr the signal exceeds the positive full scale.
test cells and connections.
UndEr The signal exceeds the negative full scale.
test cells and connections. If you want to read positive and negative
signals, make sure the converter is set to bipolar.
11. WAARRN
NIIN
NGG: C
CEEL
LLLT
TE TSS(C
ESST COOD
DEE02001)
Through this option, you may read the signal received by the instrument
from the loading cells. PASSWORD code 02001. when the code is
M n.nn confirmed, the mill Volts read by the converter will be displayed.
1111..11.. CCEELLLL TTEESSTT AASSSSEESSSSM
MEEN
NTT
the signal from the cells shall range between the max value of 0,00 mV
and 10,00 mV ( or -10,00 mV in the presence of bipolarity). Higher
signals indicate an overload or a damage. Press on the cells to make sure
the signal moves.
Cell totally empty: (with neither weight nor tare) mV from 0,00 to 0,20. Zero offset
values up to 2,00 mV can however be deemed to be acceptable for proper operation.
Cell with tare weight: (value not normally read on the instrument after the zero
setting) the read mV shall match the following equation:
{10,00 : max cell capacity = nn,nn : tare weight } Tare = cell p.max x nn,nn : 10,00
Cell with net weight loaded: (on the instrument, after calibration, only the net weight
will be read) {10,00 : max cell capacity = nn,nn : net weight + tare}
Net weight + Tare = cell p.max x nn,nn : 10,00
12. OTTH
HEER
RPPA
ARRA
AMME
ETTE
ERRSS
1122..11.. E
ENNA
ABBL
LIIN
NGGT
THHE
ETTA
ARRE
EKKE
EYY ((C
COOD
DEE 1100009999))
This setting allows for enabling or inhibiting the instrument’s tare key so as to avoid
having it pressed by mistake.
1122..22.. D
DIISSPPLLAAYYIIN
NGG IIN
NDDE
EXXIIN
NGGT
TEEN
NT H ((C
TH COOD
DEE 0011000000))
This parameter allows the weight to be displayed with a definition that is 10 times
greater that the calibration.
page 19 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
Press ↵ to confirm the entered code and enter the selection stage.
GrAVit The text GRAVIT will be displayed for 2 seconds
Gr SI Gr no Change over the selection through the key to enable
or inhibit the gravity correction function.
13. AN
NAAL
LOOG
GOOU
UTTP
PU T(C
UT COOD
DEE00531)
In case of analog output present, it is available factory configured as 0-10 Volt, -5/+5
Volt, 0-20 mA or 4-20 ma.
Use the PASSWORD setting method
OFFSET is shown for about 3 seconds and then the display shows the
zero offset value.
shows o 00 allowing the offset setting
page 20 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
percentage value of the positive offset required for the zero value of the
analog output (99 corresponds to the 5% of the full scale value).
Use the numerical setting method.
1133..22.. F
FUUL
LLL SSC
CAAL
LEEC
CAAL
LIIB
BRRA
ATTIIO
ONN
FS A is shown for about 3 seconds and then the display shows the full
scale value.
shows A00000 allowing the full scale setting.
weight value corresponding to the full scale value of the analog output.
Use the numerical setting method.
14. SEERRIIAALLO
OUUT
TPPU
UTTSSE
ETTT
TIIN
NGG
The RS232/RS485 SERIAL output is factory configured.
page 21 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
1144..22.. P
PAARRAAM
MEET
TEER
RSS
PArAM PArAM is displayed for about 3 seconds.
P 8n1 P 8n1 (Def)- 8 bit, parity none and 1 stop
P 7E1 P 7E1 7 bit, even parity and 1 stop
P 7o1 7 bit, odd parity and 1 stop
P 701
701
Note: modes other than 8,n,1 will be implemented at a future
time. At the moment, their selection has no effect.
1144..33.. T
TRRAAN MIISSSSIIO
NSSM ONNM
MOOD
DEE
14.3.1. CONTINUOUS TRANSMISSION
Cont Cont is displayed = continuous transmission
page 22 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
1 4 . 3 . 1 . 6 . C us t o m p r o t o c o l
This protocol allow to customize the serial output string with a SDSerial.exe program that may be
required to NBC
page 23 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
CAnA
CAnALE
page 24 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
page 25 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
(*) the checksum is calculated starting from the character coming after the STX
character, performing an XOR among the characters, except for character ETX [3].
The resulting decimal number shall be transformed into hexadecimal, and split into
two Ascii characters that will be transmitted (CC).
e.g. STX 129 [R] [P] CC ETX
[129] xor [R] xor [P] = 129 xor 82 xor 80 = 131 into hexadecimal 83H
The checksum will be [8] [3] the string to be transmitted will be:
STX 129 [R] [P] [8] [3] ETX
1 4 . 3 . 5 . 1 . ( R e a d W e i gh t )
page 26 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
STX [n°c] [WSn] [pppppp] CHK ETX where n of WSn = set no.
STX (CHR$(6)) ETX (OK) STX (CHR$(21)) ETX
(ERROR)
page 27 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
page 28 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
15. IN
NSSTTR
RUUM
MEEN
NTT’SSIIN
NNNE
ERRSSE
ELLE
ECCT
TIIO
ONNSS(C
COOD
DEE
00011)
These functions are instrument’s inner functions and divide into software
and hardware functions.
The software functions peak, hold or special are not all enabled at the
same time. The functions with additional hardware (serial output,
analogue output or parallel binary output) are factory presets.
1155..11.. F
FUUN
NCCT
TIIO
ONND
DIISSP
PLLA
AYY
Use the PASSWORD setting method
C00011 Write the code C00011 press Mode (pn) to confirm it.
SEtUP is displayed for about 3 seconds, then the next datum is displayed.
Set UP
15.1.1. PEAK FUNCTION
PEAC 0 PEAC 0 (Def)- peak function inhibited
PEAC 1 PEAC 1 - peak function enabled
page 29 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
1155..22.. SSEETTTTIIN
NGG FFU
UNNC
CTTIIO
ONNSS
Use the PASSWORD setting method
C11011 Write the code C11011 press the Mode key (pn) to confirm it.
ü SEtUP id displayed for about 3 seconds, then the next datum will show
up.
Proceed as for Function display (paragraph 15.1), considering that the
displayed function can be modified.
The software functions (peak, hold or special) do not use any additional
hardware, but shall not be set all together.
The functions with additional hardware (serial, analogue or parallel binary
output) shall be set according to the present hardware.
The RS232 serial output can be contemporary to analogue or binary.
1155..33.. F
FIIRRM
MWWA
ARRE
EUUPPG
GRRA
ADDE
E
Is possible to update the firmware machine at the last version by the serial port.
After connect the PC to the instrument, run the update program “Megaflash.exe”
page 30 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
16. IN
NSST
TRRU
UMME
ENNT
TPPA
ARRA
AMME
ET ER
TE RSS
These are internal instrument parameters to be used, only in such particular cases, by trained
personnel only. PASSWORD Setting method using the code C00022.
AUTO 0 AUTOZERO AT SWITCHING ON. This parameter define a weight interval around the zero so
that if the weight is inside this interval during the switching on the visualisation of the value 00000
is forced. This forcing does not introduce any error in the weighing. If during the switching on the
weight does not fall within this interval it is correctly displayed. This parameter is define with the same
unit as the weight. Assigning the value 00000 to this parameter the function is disabled.
It is normally used when there is the possibility that on the balance will remain some material that
could be considered as an additional tare.
CONT 0 ZERO CHECK. This parameter represents the weight range inside which the weight is considered in
minimum weighing. The unit is the same as the visualised weight.
ZERO TRACKING This function allow the display to be maintained at 00000 even when alterations in the time
due to accumulations of material as well as system drifts are present. The zero forcing does not
introduce any error during weighing. The zero tracking is carried out by setting the parameters TIME
and RANGE afterwards described. When the weight remains within of the zero tracking range for a
time lower than the zero tracking time an automatic zeroing is carried out.
T 0 TR ZERO TRACKING TIME. This parameter defines a time interval that, when elapsed, any
variations of zero must be compensated. It is coupled with the next zero tracking range parameter.
The unit of this parameter is the tenth of second; to set a time of one second, it is therefore necessary
to write 10. The parameter is disabled by inserting the 0 value.
R 0 TR ZERO TRACKING RANGE. This parameter defines an interval of weight inside which any
variations of zero must be compensated. It is coupled with the previous zero tracking time. The unit
of this parameter is the under-division that corresponds to a tenth of the division of the visualised
weight.
P MASS MAXIMUM RANGE. This parameter defines a weight value above which the display locks the
weight reading and shows ------. The value has the same unit as the weight. Insert 0 or a value above
the full scale of the balance to disable this function. This parameter is used to avoid an overload of the
load cells.
STABLE WEIGHT. As Stable weight is intended the recognition of the condition of firm weight by the
instrument. By means of the stable weight time and stable weight range parameters the instrument
can detect this condition even if the weight is not perfectly firm. When the weight remain within the
stable weight range for a time higher of the stable weight time then the weight is considered
stationary. The detection of stable weight is used in automatically when the precise value of a weighing
has to be printed, memorised or transmitted on the serial line.
T PST STABLE WEIGHT TIME. This parameter defines a time interval that, when elapsed, a firm weight
is considered as stable. It is coupled to the following stable weight range. The unit of this parameter
is the tenth of second; to set a time of one second, it is therefore necessary to write 10. As normal
value is used 20. This value can be reduced if the recognition of stable weight has to be faster; anyway
the suggestion is not to set a value lower of 04.
R PST STABLE WEIGHT RANGE. This parameter defines an interval of weight inside which the weight
is considered stable. It is coupled with the previous stable weight time. As normal value is used 1
that corresponds to a stable weight detected within ± 1 minimum reading unit. If the recognition of
stable weight is required in not perfect stability conditions too (for external causes such as vibrations,
wind, etc.) then this value can be slightly increased.
MONOT MONOTONY. Monotony intends the recognition of the condition of weight in movement carried
out by the instrument. This parameter damps all weight variations caused by vibrations, wind etc. till
the weight is not recognised in movement, (that is to say, when the material is really loaded or
discharged). The unit of this parameter is the tenth of second; to set a time equal to a second, it will be
therefore necessary to write 10. As a normal value is used 4. It can be useful to increase it when the
visualisation at firm weight is not stable.
DIGITAL FILTER. Digital filter intends the software function which allows the reading of weight to be stabilised
and the oscillations which are not attenuated by the analog filter, to be damped. This damping can be
page 31 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
carried out by setting properly the digital filter range and digital filter average afterwards
described.
FIN DIGITAL FILTER RANGE. This parameter represents the interval of weight inside which the next
parameter of reading mean will be activated. In normal conditions the value is 50. In case of weights
which are subjected to oscillations, it is convenient to increase this value of some units. If the
instrument is used in optimum conditions and at the maximum resolution it is possible to decrease the
value at 5.
N LETT DIGITAL FILTER MEAN. This parameter defines a number of conversions which must be used
to calculate the internal averages for damping. As a normal value it has to be used 20. It can be useful
to increase it when there are slow oscillations only, since they make difficult the stability of weight (i.e.
with weighing on a crane).
TAUTO AUTOMATIC TARE. It enables or inhibits the automatic tare function ( with stable weight) below
a threshold value that can be set. If a value other than zero is entered in the parameter, the function is
enabled: when the weight falls below the set value, once stable, the weight will be set to zero.
BL nEG NEGATIVE WEIGHT BLOCK.
17. PAAN
NEEL
LCCU
UTTO
OUUT
T
68mm
18. MO
OUUN
NTTIIN
NGGA
ACCC
CEESSSSO
ORRIIE
ESS
page 32 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
19. CO
ONNN
NEEC
CTTIIO
ONNSS
An +
AL +
Bit 1
Bit 2
Bit 3
Bit 4
AL -
An -
Mod. SD
M3 IN/ANALOG
J2 Seriale
R1 R2 R3 R4
M1 Alim. M2 IN/OUT
L N
+ - 1 2 3 4 5 6 7 8 9 10 11 12
Com
In 1
In 2
In 3
In 4
In 5
J1 Load Cell
Com 1-2
Com 3-4
Set 1
Set 2
Set 3
Set 4
J1 LOAD CELL
M1 Power supply terminals CONNECTOR NB:
1 - Excitation (blue) make these two
L Line 2 - Reference (black) jumpers for
N Neutral 4 + Reference (white) 4 wires
5 + Excitation (red) connections
6 - Signal (green) to the load cells
M2 Input/Output terminal strip 9 + Signal (yellow)
1 Out. Set 1
2 Out. Set 2 J2 RS232 CONNECTOR
3 Common set 1,2
4 Out. Set 3 RS232 RS422
2 Rx 7 Rx-
5 Out. Set 4 3 Tx 9 Rx+
6 Common set 3,4 5 Gnd 4 Tx+
8 Cts 6 Tx-
7 In1 = autotare (temporary zero) 1 Rts
8 In2 = autotare delete
9 In3 = activate actual function (Peak o Hold) / Print M3 Input/Output
10 In4 = disactivate actual function (Peak o Hold) 1 Input Bit 1 (1)
11 In5 = weight block 2 Input Bit 2 (2)
12 common for inputs 3 Input Bit 3 (4)
4 Input Bit 4 (8)
5 Common positive inputs
6 Common negative inputs
7 Positive analogic output
8 Negative analogic output
page 33 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
SD
DECLARATION OF CONFORMITY
in accordance with:
• EN 50082-1 (Elettromagnetic compatibility - Generic immunity standard - Part 1:
Residential, commercial and light industry).
• EN 55011 (Limits and methods of measurement of radio disturbance
characteristics of industrial, scientific and medical (ISM) radio-frequency
equipment).
• IEC 801-2 (Electromagnetic compatibility for industrial process measurement and
control equipment - Part 2: Electrostatic discharge requirements).
• IEC 801-3 (Electromagnetic compatibility for industrial process measurement and
control equipment - Part 3: Radiated electromagnetic field requirements).
• IEC 801-4 (Electromagnetic compatibility for industrial process measurement and
control equipment - Part 4: Electrical fast transient/burst requirements).
Nemko
Alfla
Nemko
November 2010
NBC Elettronica srl
via Tavani 2/C
I 23014 Delebio
SONDRIO (Italy)
page 34 of 35
SD-01: set point version Manual N°SE0001E0 vers. 1.0
INFORMAZIONI AGLI
UTENTI
Ai sensi dell’art. 13 del Decreto Legislativo 25 Luglio 2005, n.151 “Attuazione delle direttive
202/95/CE, 2002/96/CE e 2003/108/CE, relative alla riduzione dell’uso di sostanze pericolose
nelle apparecchiature elettriche ed elettroniche, nonché allo smaltimento dei rifiuti”.
Il simbolo del cassonetto barrato sopra riportato sull’apparecchiatura o sulla sua confezione o
sul manuale istruzioni, indica che il prodotto alla fine della propria vita utile deve essere
raccolto in modo differenziato e separatamente dagli altri rifiuti come sancito dal D. Lgs.
151/2005.
Il presente apparecchio è conforme alla normativa RoHS.
According to the senses of the art. 13, Legislative Decree 25 July 2005, n.151 “Accomplishment
of the Directives 202/95/CE, 2002/96/CE and 2003/108/CE, regarding the reduction in the use
of dangerous substances in electric and electronics equipments, as well as the disposal of
waste material”.
The symbol of the crossed rubbish skip stamped on the equipment or on the package or on
the using manual indicates that at the end of the useful life the device must be collected in a
specific collection, separately from other waste material as sanctioned on the Legislative
Decree 151/2005.
RoHS compliant.
page 35 of 35