Sie sind auf Seite 1von 2

Lenth of beam 4 mtr

Factored moment = 6 Kn m
factored shear force = 6 Kn
Provide section 96x48x3.2
fy= 310
A = 8.54 cm2 = 854 mm2
h = 96 mm
b = 48 mm

t = 3.2 mm
tw = 3.2 mm

Iz = 98.61 X 10 4 mm4
Iy = 33.28 X 10 4 mm4
Zez = 20.54 X 10 3 mm3
Zey = 13.87 X 10 3 mm3
Zpz = 25.85 X 10 3 mm3
rz = 3.4 cm = 34 mm
ry = 1.97 cm = 19.7 mm
zpy = 15.91 X 10 3
mm 3

2) Cross section classification


Ꞓ = sqrt(250/fy) = 0.90

D/t = Err:511
= 30 <42 hence Flange is plastic

d = h-2 tf
= Err:511
= 89.6
B/tw = Err:511
28 <67 <42 hence Flange is plastic

Check for local capacity of the cross section for combined effect
Vp=Avfyw/(sqrt(3)ymo) Av=Ah(b+h)=854x96/(96+48) = 569.33 mm2
Vp=

92634.43 = 92.63

0.6 Vp = 55.58 kn shoud be greater than 6 kn

Design bending strength due to bending about Z-Z axis

Mdz=BbZpz fy/ymo Bb=1 for Plastic section


=
= 7.29 Knm

Minimum limiting moment for simply supported beam=


Mlt=1.2Zez fy/ymo

6.95

so bending strength of the section will be


= 6.95 Kn m
Designed moment is greater than applied moment and
hence section is safe

Das könnte Ihnen auch gefallen