Sie sind auf Seite 1von 4

MAX TANK VOLUME SELECTION TABLE

Series
Process
MF MS
3 3
simple mixing 5m 70 m

reagent preparation 3m
3
30 m
3

neutralisation 2m
3
20 m
3
G

A
sludge suspension 50 ÷ 80 g/l 1.7 m
3
15 m
3

3 3
0 ÷ 100 g/l 1.5 m 15 m
lime 3
100 ÷ 200 g/l ----- 15 m E
C

3
polyelectrolyte 0 ÷ 10 g/l ----- 15 m
B

POSITIONING MIXER
G > 100 for MF series if 0.5 < A / B <1.1 single propeller C = 0.5 ÷ 2 x E
G > 200 for MS series
IMPORTANT! If the mixer is centred in the tank, it is necessary to install 3 if 1.1 < A / B < 1.6 double propeller D = 2 x E (MS series)
antirotation baffles positioned at 120° for MF series, 4 baffles positioned at 90° for D = 5 x E (MF series)
MS series
A = liquid height
B = tank diameter CHOICE OF THE PROPELLER/TANK DIAMETER RATIO
C = distance between propeller and bottom of the tank
D = distance between two propellers E = B x 0.3 for serie MS series
E = propeller diameter E = B x 0.2 for serie MF series

MOTOR POWER REQUIREMENT TABLE OF VISCOSITY COEFFICIENTS


Mixer are mounted with a motor of adequate power. To calculate the necessary
motor power use the following formulas:

Preal = Pneeded x liquid density x viscosity coefficient viscosity cps correction coefficient
(Pneeded = power in water: read from the table of each mixer) 20 1.10
30 1.20
It is necessary to verify that motor power is:
Ÿ equal to Preal + 5% for MF series 40 1.25
Ÿ equal to Preal + 25% for MS series 50 1.30
100 1.40
Keep in mind that: 200 1.50
Ÿ if speed is increased by 50%, motor power must be increased by ~ 3 times 300 1.60
Ÿ if propeller diameter is increased by 50%, motor power must be increased ~7 500 1.70
times 700 1.75
Example: MF series with 950 rpm - propeller Ø 120 - motor 0.25 kW
1000 1.85
Ÿ to move to 1400 rpm it is necessary to use a motor with 1 kW
Ÿ to use a propeller of Ø 180 it is necessary to choose a motor with 1.5 kW 2000 2.00

Power conversion formula: hp = kW x 0.75


To be used with low viscosity liquids
in medium capacity tank or basin to
mix or prepare chemical solution.

MOTOR
Ÿ Single-phase / 3-phases - IP55
Ÿ 0.12 kW - 4 poles

other motor powers


available on request

PROPELLER NEEDED POWER


Ÿ PVC / AISI 316L - 2 blades Power Real Speed -
Power
in water rpm
Ÿ diameter: 90 mm 0.12 kW 0.07 kW 1360
0.18 kW 0.11 kW 1350
other diameters 0.25 kW 0.15 kW 1350
available on request

SPARE PARTS AVAILABLE


Ÿ Motor + flange
Ÿ Propeller
Ÿ Shaft
To be used in water treatment field
to flocculation or polyelectrolyte
preparation.

MOTOR + GEAR
Ÿ Single-phase / 3-phases - IP55
Ÿ 0.12 kW - 4 poles

other motor powers


available on request

Reduction ratio:
Ÿ 1:7 ( 200 rpm - 4 poles motor )
Ÿ 1:20 ( 70 rpm - 4 poles motor )

other reduction ratio


available on request

PROPELLER
Ÿ PVC / AISI 316L
Ÿ 2 / 3 / 6 blades
( filled / unloaded )
Ÿ diameter: 90 mm
150 mm
220 mm

other diameters
available on request

SPARE PARTS AVAILABLE NEEDED POWER


Ÿ Motor + flange + support Power Real Speed -
Power
in water rpm
Ÿ Propeller
nd 0.12 kW 0.06 kW 194
Ÿ 2 Propeller 0.18 kW 0.08 kW 193
Ÿ Additional blades ( only PVC ) 0.25 kW 0.11 kW 193

Ÿ Shaft
MIXER IDENTIFICATION TABLE

M S 1 1 2 T 4 A 0 9 D 1 2 0 0

1° Product
2° TYPE
3° Ratio
4° 5° Motor power
6° Power supply
7° Motor poles number
8° Contact materials
9° 10° Shaft length

11° Blades number / holes


12° 13° Propeller diameter
14° 15° OPTIONAL

Product Contact materials


M Mixer A Aisi 316
P PVC
TYPE
F Fast (without reduction gear) Shaft length
S Slow (with reduction gear)
06 00 mm
Ratio 08 00 mm
0 1:1 - ( Fast Speed ) 09 00 mm
1 1:7 - 200 rpm ( with 4 poles motor ) 11 00 mm
2 1:20 - 70 rpm ( with 4 poles motor )
Blades number / holes
Motor power A 2 / filled
0,12 kW B 3 / filled
0,18 kW C 6 / filled
0,25 kW
0,37 kW
Propeller diameter
Power supply 09 0 mm
M monofase 230 Vac 15 0 mm
T trifase 230 / 400 Vac 22 0 mm

Motor poles number OPTIONAL


2 2 poli 0 standard
4 4 poli 0 standard

Das könnte Ihnen auch gefallen