Sie sind auf Seite 1von 6

www.

cuk
13 - 2500 kVA standby
12 - 2255 kVA prime

www.cukurovapower.com

Cukurova CJ series PN
Diesel Generators VS
CN
VL
VN
CJ series PN
VS
CN
VL
VN

Cukurova CJ series Diesel Generators


Cukurova CJ series is leading the market with The generators are factory built and production tested.
ultimately engineered high performance power Certificates
solutions providing low cost services during ISO 9001:2008 Quality Management System
product life-cycle for its customers worldwide for ISO 14001:2004 Environmental Management Sys.
more than 30 years. OHSAS 18001 Health&Safety Management Sys.

Perkins engines
400 series 3 and 4 cylinder mechanical governor Electrical system
1100 series 3,4 and 6 cylinder mechanical/electronic 12/24 volt starter motor and 35-55 amp
1500 series 6 cylinder electronic governor alternator with integral regulator and DC output
2000 series 6 cylinder electronic governor 12/24 volt combined high coolant temperature/
4000 series 6,8,12 and 16 cylinder birim enjektörlü low oil pressure switch
12/24 volt stop solenoid (energised to run)
Volvo engines Standards & Compliance
500 series 4 cylinder mechanical/electronic governor ISO 8528/1, ISO 3046/1, BS5514/1.
700 series 6 cylinder mechanical/electronic governor Fuel specification: BS2869: Class A2
1300 series 6 cylinder electronic governor Fuel system
1600 series 6 cylinder electronic governor Governing to ISO 8528-5 class G2/G3
Full-flow spin-on fuel oil filters
Cummins engines Lubrication system
S series 3 cylinder mechanical governor Wet sump with filler and dipstick
B series 6 cylinder mechanical governor Full-flow spin-on oil filters
QSL series 6 cylinder electronic governor Cooling system
QSX series 6 cylinder electronic governor Gear driven circulating pump
VTA series 12 cylinder electrical fuel control Crankshaft pulley for fan drive
KTA series 12 and 16 cylinder electrical fuel control Tropical Radiator assemblies comprising:
QSK series 6 and 16 cylinder electronic governor water radiator; air charge cooled radiator;

Stamford, Leroy Somer ve Sincro series alternator


Synchronous single bearing alternator, brushless Insulation/Impregnation
with rotating field, self excited, self-ventilated, Class H insulation meets the requirements of
50Hz, 231/400V, pf 0.8, 4 poles, UL1446
Voltage regulation over than 800kVA Standards & Compliance
Excited by PMG, Permanent Magnet Generator Meets the requirements of BS EN 60034 and
Shaft mounted pilot exciter providing a constant the relevant sections of BS5000, VDE 530,
supply of clean power via the AVR, Automatic NEMA MG1-32, IEC60034, CSA C22.2-100,
Voltage Regulator AVR having features; AS1359.
soft start voltage build up Dynamically balanced better than BS6861:Part1
built in protection against over-excitation Grade 2.5 for minimum vibration in operation.
underspeed protection, UFRO
Windings&Electrical performance
Stator 2/3 pitch design winding
eliminates triplen harmonics
trouble-free supply of non-linear loads
avoids excessive neutral currents
very low levels of waveform distortion
13-2500kVA Standby
12-2255kVA Prime
9-1804kVA Continuous

AMF Control Panel


The DSE 7320/AMF3.4L is operated via START, Programmable protective functions
STOP,AUTO, MANUAL and TEST buttons with Generator phase sequence
LCD display. Over/Under generator voltage
Generator instruments Over/Under generator frequency
Volts, Hz, Amps, kW, kVA, pf, kWh, kVAr, kVArh, Reverse power
kVAh Overcurrent
Engine instruments Battery charger failure
RPM, Oil Pressure, Coolant Temperature, Hours Mains out of limits
Run, Charging Voltage, Battery Volts. Loss of speed signal
Enhanced instrumentation and Engine ECU Maintenance alarm
diagnostics via electronic engine interface. Generator short circuit protection
Mains/Utility instruments Fails to close Generator/Mains circuit breaker
Volts, Frequency, Amps Over/Under battery voltage
Communication capabilities Light Load Operation
SMS messaging kW overload
Remote communications Fuel Usage Alarm
Remote control Low Fuel Level Alarm
Building management
PC software
Warnings/Shutdowns Environmental testing standards
Low oil pressure Electrical Safety BS EN 60950
High coolant temperature Electromagnetic Comp. BS EN 61000-6-2
Overspeed/ Underspeed Industrial Environment BS EN 61000-6-4
Emergency stop Temperature Operating BS EN 60068-2 1&2
Failure to start (overcrank) Vibration BS EN 60068-2-6
Low coolant level Humidity BS EN 60068-2-30
Earth fault Shock BS EN 60068-2-27
ISO 9001 worldwide operations over than 30 years
ISO 14001
OHSAS 18001

Equipments & Services

Standard Optionals
Diesel engine, industrial type Transfer Panels & Load Control Systems
Tropical radiator complete with fan & guards Synchronisation Panel & Load Control Systems
Batteries, Charging alternator Remote Applications and Communication Systems
Air, lube oil and fuel filters
Engine block heater
Alternator, brushless, industrial type
Control Panel
AMF control module, Auto-Manual-Test-Stop
Shutdown alarms & warnings
Emergency stop button, Battery charger
Exhaust silencer with Flexibles & ANSI type flanges Protection Circuit Berakers
Anti-vibration mountings Oversize components & equipments
Daily fuel tank, for 8hr running at 75% load Alternator, Circuit Breaker, Battery Charger
Services Extra fuel tank with additional accessories
Factory full load and function tests Manual/Auto, fuel & lube oil drain pumps
At site commissioning & start-up Spare Parts recommended for any operation period
Customer trainings at Cukurova factory Enclosures
Documentation Weather & sound proof
Factory Full Load & Function Test Reports Container type
Operation & Maintenance Manuals Applications that need customised manufacture
Spare Parts Book
Installation Instructions

Silencers, Exhaust
Residential, Critical, Super Critical
Ratings Catalytic Converter, Spark Arrester
All 3phase units are rated at 0.8 power factor and the Ratings Silencers, Air Inlet & Outlet
are in accordance with ISO-8528-1 and ISO-3046-1. Services
Standby Ratings The standby rating is applicable to varying Installation at site w/o construction works
loads for the duration of a power outage. There is no overload Periodical Maintenances & Services
capability for this rating. Engine & Alternator Factory Visits & Trainings
Prime Ratings At varying load, the number of generator set 3rd Party Inspection & Services
operating hours is unlimited. A 10% overload capacity is available

for one hour in twelve.

For limited running time and continuous ratings, consult our

Cukurova Applications Dept. to obtain technical information for

rating guidelines, complete rating definitions and site condition

derates by a mail to

applications@cukurovapower.com
The generator set manufacturer reserves the right to change Consult Cukurova Sales to obtain more information about our

the design or specs without notice and without any obligation optionals and any demand other than listed above, by a mail to

or liability whatsoever. sales@cukurovapower.com


13-2500kVA Standby
12-2255kVA Prime
1500rpm, 380/415V, 50Hz, pf 0.8, 3phase
ENGINE ALTERNATOR ENGINE ALTERNATOR
MODEL MODEL
BRAND MODEL BRAND MODEL BRAND MODEL MARKA MODEL

CJ15PN Perkins 403A-15G1 Stamford PI044F CJ90VL Volvo TAD530GE Leroy Somer TAL044B

CJ16PN Perkins 403A-15G2 Stamford PI044G CJ110VL Volvo TAD531GE Leroy Somer TAL044D

CJ22PN Perkins 404A-22G1 Stamford PI144D CJ140VL Volvo TAD532GE Leroy Somer TAL044H

CJ33PN Perkins 1103A-33G Stamford PI144G CJ165VL Volvo TAD731GE Leroy Somer TAL044J

CJ50PN Perkins 1103A-33TG1 Stamford UC224D CJ200VL Volvo TAD732GE Leroy Somer TAL046A

CJ65PN Perkins 1103A-33TG2 Stamford UC224E CJ220VL Volvo TAD733GE Leroy Somer TAL046B

CJ70PN Perkins 1104A-44TG1 Stamford UC224F CJ275VL Volvo TAD734GE Leroy Somer TAL046D

CJ90PN Perkins 1104A-44TG2 Stamford UC224G CJ350VL Volvo TAD1341GE Leroy Somer TAL046G

CJ110PN Perkins 1104C-44TAG2 Stamford UCI274C CJ400VL Volvo TAD1342GE Leroy Somer TAL046H

CJ150PN Perkins 1106A-70TG1 Stamford UCI274E CJ415VL Volvo TAD1343GE Leroy Somer TAL047A

CJ165PN Perkins 1106A-70TAG2 Stamford UCI274F CJ450VL Volvo TAD1344GE Leroy Somer TAL047A

CJ200PN Perkins 1106A-70TAG3 Stamford UCI274G CJ500VL Volvo TAD1345GE Leroy Somer TAL047B

CJ220PN Perkins 1106A-70TAG4 Stamford UCD274H CJ550VL Volvo TAD1641GE Leroy Somer TAL047C

CJ250PN Perkins 1506A-E88TAG2 Stamford UCD274J CJ650VL Volvo TAD1642GE Leroy Somer TAL047E

CJ275PN Perkins 1506A-E88TAG3 Stamford UCD274K CJ700VL Volvo TAD1643GE Leroy Somer TAL047F

CJ300PN Perkins 1506A-E88TAG4 Stamford S4L1D-D CJ715VL Volvo TAD1644GE Leroy Somer TAL047F

CJ330PN Perkins 1506A-E88TAG5 Stamford S4L1D-D CJ770VL Volvo TAD1645GE Leroy Somer TAL049B

CJ400PN Perkins 2206A-E13TAG2 Stamford S4L1D-E

CJ450PN Perkins 2206A-E13TAG3 Stamford S4L1D-F CJ140VN Volvo TAD532GE Stamford UCI274E

CJ500PN Perkins 2506A-E15TAG1 Stamford HCI544C CJ165VN Volvo TAD731GE Stamford UCI274F

CJ550PN Perkins 2506A-E15TAG2 Stamford HCI544D CJ200VN Volvo TAD732GE Stamford UCI274G

CJ670PN Perkins 2806A-E18TAG1A Stamford HCI544E CJ220VN Volvo TAD733GE Stamford UCI274H

CJ720PN Perkins 2806A-E18TAG2 Stamford HCI544F CJ275VN Volvo TAD734GE Stamford UCD274K

CJ800PN Perkins 4006-23TAG2A Stamford HCI634G CJ350VN Volvo TAD1341GE Stamford S4L1D-D

CJ900PN Perkins 4006-23TAG3A Stamford HCI634H CJ400VN Volvo TAD1342GE Stamford S4L1D-E

CJ1100PN Perkins 4008TAG2A Stamford HCI634J CJ415VN Volvo TAD1343GE Stamford S4L1D-F

CJ1250PN Perkins 4008-30TAG3 Stamford HCI634K CJ450VN Volvo TAD1344GE Stamford S4L1D-F

CJ1400PN Perkins 4012-46TWG2A Stamford PI734B CJ500VN Volvo TAD1345GE Stamford HCI544C

CJ1500PN Perkins 4012-46TWG3A Stamford PI734B CJ550VN Volvo TAD1641GE Stamford HCI544D

CJ1650PN Perkins 4012-46TAG2A Stamford PI734C CJ650VN Volvo TAD1642GE Stamford HCI544E

CJ1900PN Perkins 4012-46TAG3A Stamford PI734E CJ700VN Volvo TAD1643GE Stamford HCI544F

CJ2000PN Perkins 4016-61TRG1 Stamford PI734E CJ770VN Volvo TAD1645GE Stamford HCI634G

CJ2020PN Perkins 4016TAG1A Stamford PI734E

CJ2250PN Perkins 4016TAG2A Stamford PI734F CJ90VS Volvo TAD530GE Sincro SK225MS

CJ2250PN Perkins 4016-61TRG2 Stamford PI734F CJ110VS Volvo TAD531GE Sincro SK225ML

CJ2500PN Perkins 4016-61TRG3 Stamford PI734H CJ140VS Volvo TAD532GE Sincro SK225LS

CJ165VS Volvo TAD731GE Sincro SK250SL

CJ45CN Cummins S3.8G4 Stamford PI144J CJ200VS Volvo TAD732GE Sincro SK250MS

CJ55CN Cummins S3.8G6 Stamford UCI224D CJ225VS Volvo TAD733GE Sincro SK250ML

CJ110CN Cummins 6BTA5.9G5 Stamford UCI274C CJ275VS Volvo TAD734GE Sincro SK250LS

CJ170CN Cummins 6BTAA5.9G7 Stamford UCI274F CJ350VS Volvo TAD1341GE Sincro SK315SS

CJ350CN Cummins QSL9G5 Stamford S4L1D-D CJ400VS Volvo TAD1342GE Sincro SK315SS

CJ450CN Cummins QSX15G4 Stamford S4L1D-F CJ415VS Volvo TAD1343GE Sincro SK315SM

CJ550CN Cummins QSX15G8 Stamford HCI544D CJ440VS Volvo TAD1344GE Sincro SK315SM

CJ700CN Cummins VTA28G5 Stamford HCI544F CJ500VS Volvo TAD1345GE Sincro SK315SL

CJ860CN Cummins QSK23G3 Stamford HCI634G CJ550VS Volvo TAD1641GE Sincro SK355MS

CJ1100CN Cummins KTA38G5 Stamford HCI634J CJ650VS Volvo TAD1642GE Sincro SK355LS

CJ1350CN Cummins KTA50G3 Stamford PI734A CJ700VS Volvo TAD1643GE Sincro SK355LM

CJ1400CN Cummins KTA50G3 Stamford PI734B CJ715VS Volvo TAD1644GE Sincro SK355LM

CJ2250CN Cummins QSK60G4 Stamford PI734F CJ770VS Volvo TAD1645GE Sincro SK355WL
Cukurova Jenerator San.Tic.A.S.
Izmir Factory Istanbul Export Sales Management
Boss Sk. No:11 ESB-Gaziemir E5 yan yol üzeri Kanuni Sokak
Izmir-Turkey No:1 Soğanlık Kartal-İstanbul-Türkiye
Tel : +90 232 252 2026 Tel : +90 216 625 1500
Mail: applications@cukurovapower.com Mail: sales@cukurovapower.com
www.cukurovapower.com

Manufactures high performance customised power systems and provides ultimate services during life-cycle of the products
with low cost availability for customer's operations worldwide.

Das könnte Ihnen auch gefallen