PCASSG1601B

Product Lineup 1 phase 3 phase

Product Series 50 60 71 100 125 140


CEILING MOUNTED CASSETTE TYPE
NEW NEW NEW
Round Flow FCQ50LUV1 FCQ60LUV1 FCQ71LUV1
FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA
Indoor unit

NEW NEW NEW NEW NEW


RZR50LVVM RZR60LVVM RZR71LVVMG
Page 10 RZR100MVMG RZR100MYM RZR125MVMG RZR125MYM RZR140MYM
Outdoor unit

DUCT CONNECTION MIDDLE


NEW NEW NEW NEW NEW NEW
and HIGH STATIC PRESSURE TYPE
FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
Indoor unit

NEW NEW NEW NEW NEW


RZR50LVVM RZR60LVVM RZR71LVVMG
Page 12 RZR100MVMG RZR100MYM RZR125MVMG RZR125MYM RZR140MYM
Outdoor unit
Pair

CEILING SUSPENDED TYPE


NEW NEW NEW
FHQ50BVV1G FHQ60BVV1G
FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA
Indoor unit

NEW NEW NEW


RZR50LVVM RZR60LVVM
Page 14 RZR100MYM RZR125MYM RZR140MYM
Outdoor unit

WALL MOUNTED TYPE


FAQ100CVEA
Indoor unit

NEW
Page 16 RZR100MYM
Outdoor unit

OUTDOOR UNIT

NEW NEW NEW NEW NEW


Outdoor unit RZR50LVVM RZR60LVVM RZR71LVVMG RZR100MVMG RZR100MYM RZR125MVMG RZR125MYM RZR140MYM

ENERGY SAVING LABEL

2 3
OPTIONAL
Outdoor unit operating
sound can be reduced
by 4dB(A).
CEILING MOUNTED CASSETTE TYPE Round Flow

Cassette Air Conditioner with 360° Compact Body for Quick & Easy Drain Pump is Equipped as
Installation in Tight Ceiling Standard Accessory with 850 mm
Uniform Airflow sets The Standard
(50LU-71LU) Lift.

256 mm *1 266 mm *2
850 mm

175 mm
*1 298 mm high with 100–140 KA/LU
*2 308 mm high with 100–140 KA/LU

Comfort Enhanced by Round Flow!


360° airflow Air movement is gentle with Easy Maintenance
With uniform temperature Round Flow
The condition of the drain pan and
distribution Enhanced Comfort he
drain water can be checked by pen t
360° airflow can Just o n grille!
removing the drain plug and o
maintain comfort sucti
even if air suction grille. Drain plug
Airflow
distribution discharge speed is
Creates uniform lower.
comfort throughout
If you raise the set With Ultra long-life filters (option), maintenance is not required in normal shops or offices for up to four years.
the space
temperature by 1 to
1.5°C,and velocity is
decreased by 25%, SPECIFICATIONS
Greater comfort you still obtain the 50 60 71 100 125 100 125 140
Improved energy saving same feeling
Model Indoor unit FCQ50LUV1 FCQ60LUV1 FCQ71LUV1 FCQ100KAVEA FCQ125KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA
temperature and
Name Outdoor unit RZR50LVVM RZR60LVVM RZR71LVVMG RZR100MVMG RZR125MVMG RZR100MYM RZR125MYM RZR140MYM
comfort.
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz

Adapts Easily to The Installation


Cooling capacity1,2 kW 5.0 (2.3-5.6) 6.0 (2.6-6.3) 7.1 (3.2-8.0) 9.5 (4.5-11.2) 10.8 (5.4-14.0) 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4)
Rated (Min. - Max.) Btu/h 17,100 (7,900-19,100) 20,500 (8,900-21,500) 24,200 (10,900-27,300) 32,400 (15,400-38,200) 36,900 (18,400-47,800) 34,100 (17,100-38,200) 42,700 (19,500-47,800) 47,800 (21,200-52,600)
Power consumption Cooling1 kW 1.03 1.40 1.80 2.51 3.22 2.78 4.31 5.62

Space. COP
Indoor Colour Decoration panel
W/W 4.85 4.29 3.78 3.79
Fresh white
3.35 3.60 2.90 2.49

unit Airflow rate (H/M/L) m3/min 21/-/13.5 32/26/20 33/28/22.5 32/26/20 33/28/22.5
Because air flows out from corner outlets, comfort Sound level (HH/H/M/L)3 dB(A) (-/35/-/28) (43/37.5/-/32) (44/39/-/34) (-/43/37.5/32 (-/44/39/34) (-/44/40/36)
spreads more widely. Dimensions
(HXWXD)
Unit mm 256X840X840 298X840X840
Decoration panel mm 50X950X950
Machine Unit kg 21 24
weight 5.5
Typical flow patterns Decoration panel kg
Certified Operation range Cooling °CWB 14 to 25
Outdoor Colour Ivory white
There are a total of 23 flow patterns. unit Compressor Type Hermetically sealed swing type Hermetically sealed swing type
Motor output kW 1.12 1.35 1.76 2.03 2.03 1.92 1.92
L-shaped Opposite Refrigerant charge (R-410A) 1.6 1.9 1.9 1.9
All-round flow 3-way flow 2-way flow 2-way flow kg (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m)
Sound level3 Cooling dB(A) 48 49 52 49 52 54
Night quiet mode dB(A) 44 45 45
Dimensions (HXWXD) mm 595X845X300 990X940X320 990X940X320
Machine weight kg 43 65 73
(E.g., installed in (E.g., installed (E.g., installed in (E.g., installed in Certified Operation range Cooling °CDB 21 to 46
Quiet Operation at 28** dB(A)
middle of ceiling) near a wall) a corner) a long room)
Piping Liquid (Flare) mm o/ 9.5
4-way flow also possible. connections Gas (Flare) mm o/ 15.9
**Selected models only Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow,
Drain Indoor unit mm VP25 (I.D o/ 25XO.D o/ 32)
Outdoor unit mm o/ 26.0 (Hole)
Note : Anechoic chamber conversion value, measured according to JIS an air discharge outlet sealing material (option) must be used to close each unused outlet. Operation sound
Max. interunit piping length m 50 (Equivalent length 70)
parameters and criteria. During operation these values are some what increases when using 2-way or 3-way flow.
Max. installation level difference m 30
higher owing to ambient conditions.
Heat insulation Both liquid and gas piping

Optimal Comfort and Convenience


Easy Cleaning with Coated
1Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
Note :
2Capacities are net, including a deduction for cooling for indoor fan motor heat.

Assured by 2 Air Discharge Modes


3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

External Panels. OPTIONS


1 Setting to prevent soiling
Treated Untreated Air direction Standard setting Name of option Remark
Kit name
of ceiling 2 (field setting) FCQ50/60/71LUV1 FCQ100/125/140KAVEA
surface surface Decoration panel BYCP125K-W1
Standard position to Recommended for shops with
Desired Sealing material of air discharge outlet KDBH55K160F
light coloured ceilings that
situation prevent draft. Panel spacer KDBP55H160FA
must be kept spotless. Fresh air Chamber Without T-joint pipe and fan KDDP55B160
Resists intake kit type With T-joint pipe, without fan KDDP55B160K
soiling Direct installation type KDDP55X160
Auto-swing Auto-swing between Auto-swing between KDDFP55B160
Grimy Filter chamber
15° and 60° 25° and 60° Replacement long-life filter KAFP551K160
surface
Ultra long-life filter unit (including filter chamber) KAFP55B160
5-levels
Replacement ultra long-life filter KAFP55H160H
air direction Settable to 5 different Settable to 5 different Chamber connection kit1 KKSJ55KA160
• Condition after exposure to
setting levels between 15° and 60° levels between 25° and 60° Wireless type Cooling only BRC7F633F BRC7F635F
the smoke of 600 cigarettes Remote controller
The air direction is set automatically to the memorised Wired type2 BRC1C61
Silver ion anti-bacterial drain pan in 1 m3 enclosed space.
Auto air position of the previous air direction. Navigation Remote Controller Wired type2 BRC1E62
direction control
Non-flocking flaps Wiring adaptor for electrical appendices (2)3 KRP4AA53
Installation box for adaptor PCB KRP1H98
Filter has anti-mould and antibacterial Note:
1 Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed Note: 1Required for installing high-efficiency filter unit and ultra long-life filter unit.
treatment
2
Wiring for wired remote controller to be procured locally.
from the remote controller. 3
Installation box for adaptor PCB (KRP1H98) is necessary.
2 Closing of the corner discharge outlets is recommended.

10 11
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

Thinner Design Allows Greater Airflow rate auto adjustment function


Controls the airflow rate using a remote controller during test run.
Installation Flexibility It is automatically adjusted to approximately ±10% of the rated H tap
airflow.

Interlock control by outside system Interlock


Enables control by hotel key card system acting as master ON/OFF
for room electricity.

Enables central control of room ventilation and lighting by


Design and Installation third-party building management system.

Flexibility SPECIFICATIONS
With a height of only 245 mm, installation is possible 50 60 71 100 125
even in buildings with narrow ceiling spaces Model Indoor unit FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE
Name RZR50LVVM RZR60LVVM RZR71LVVMG RZR100MVMG RZR125MVMG
Outdoor unit

Power supply Indoor unit


1 Phase, 220-240 V, 50 Hz
Outdoor unit

245mm Cooling capacity1,2


Rated (Min. - Max.)
kW
Btu/h
5.0 (2.3-5.6)
17,100 (7,900-19,100)
6.0 (2.6-6.3)
20,500 (8,900-21,500)
7.1 (3.2-8.0)
24,200 (10,900-27,300)
9.5 (4.5-11.2)
32,400 (15,400-38,200)
10.8 (5.4-14.0)
36,900 (18,400-47,800)
Power consumption Cooling1 kW 1.39 1.69 2.22 2.51 3.22
COP W/W 3.60 3.56 3.20 3.79 3.35
Indoor Fan Airflow rate (H/M/L) m3/min 18/15/12.5 23/19.5/16 32/27/22.5 36/30.5/25
One of the industry’s most compact bodies in the unit External static pressure3 Pa Rated 50 (50-150)
mid-static pressure range. Sound pressure level (H/M/L) 4
dB(A) 35/33/31 38/35/33 38/35.5/33 40/37.5/35
Dimensions (HXWXD) mm 245X1,000X800 245X1,400X800
Machine weight (indoor) kg 37 47
Indoor unit 71E 100/125/140E Sound pressure Cooling dB(A) 48 49 52
Outdoor
level4 Night quiet mode dB(A) 44 45
Height (mm) 245 unit
Dimensions (HXWXD) mm 595X845X300 990X940X320
Machine weight (outdoor) kg 43 65
Width (mm) 1,000 1,400 Liquid mm o/ 9.5 (Flare)
Piping
Depth (mm) 800 connection Gas
Indoor unit
mm o/ 15.9 (Flare)
Drain mm VP25 (I.Do/ 25×O.Do/ 32
Outdoor unit mm o/ 26 (Hole)
Max interunit piping length mm 50 (Equivalent length 70m)
Higher lift is realized by utilising built-in DC drain pump Heat insulation Both liquid and gas piping

with standard accessory


100 125 140

Model Indoor unit FBQ100EVE FBQ125EVE FBQ140EVE


Name RZR100MYM RZR125MYM RZR140MYM
Outdoor unit
1 Phase, 220–240 V, 50 Hz
850 mm
Power supply Indoor unit
Outdoor unit 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 kW 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4)
Rated (Min. - Max.) Btu/h 34,100 (17,100-28,200) 42,700 (19,500-47,800) 47,800 (21,200-52,600)
Power consumption Cooling1 kW 2.82 4.58 5.85
COP W/W 3.55 2.73 2.39
Fan Airflow rate (H/M/L) m /min
3
38/35.5/33 36/30.5/25
Indoor
unit External static pressure3 Pa Rated 50 (50-150)

High Efficiency Sound pressure level (H/M/L)4


Dimensions (HXWXD)
Machine weight (indoor)
dB(A)
mm
kg
40/37.5/35
245X1,400X800
47
40/37.5/35

DC Fan motor and DC drain pump are utilised to Outdoor Sound pressure
level4
Cooling dB(A) 49 52 54
unit Night quiet mode dB(A) 45
improve energy efficiency Dimensions (HXWXD) mm 990X940X320
Machine weight (outdoor) kg 73
Piping Liquid mm o/ 9.5 (Flare)
connection Gas mm o/ 15.9 (Flare)

Clean
Indoor unit mm VP25 (I.Do/ 25×O.Do/ 32)
Drain
Outdoor unit mm o/ 26 (Hole)
Max interunit piping length m 50 (Equivalent length 70m)

Silver ion anti-bacterial drain pan Heat insulation Both liquid and gas piping

A built-in antibacterial treatment that uses silver ion in the drain


1
Note: Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
pan prevents the growth of slime, bacteria, and mould that cause 3
External static pressure is changeable in 11 stages by remote controller.

Easy Maintenance smells and clogging. 4


Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
5
Air filter is not standard accessory, but please mount it in the dust system of the suction side. Select its duct collection efficiency(gravity method)50% or more.

Position of drain pan inspection opening has Using a DC fan motor, the external static pressure
been modified for easier inspection work OPTIONS
can be controlled to within a range of 50 Pa to 150 Pa Kit name
Name of option Remark
Drain pan maintenance check window FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
Adjustable external static pressure Remote controller Wireless type Cooling only BRC4C66
This makes it possible to inspect for drain pan dirt and to Wired type1 BRC1C61
confirm drainage during installation without the use of Navigation Remote Controller1 BRC1E62
Adaptor for wiring KRP1C64
tools.
50 Pa 150 Pa Wiring adaptor for electrical appendices(2)
Remote sensor
KRP4AA51
KRCS01-4B
Mounting plate for adaptor PCB.2,3,4 KRP4A98
Inspection opening for Central remote controller5 DCS302CA61
drain pan Unified ON/OFF controller5 DCS301BA61
Set to low static Set to high static pressure for
pressure when ducts advanced needs such as when Schedule timer5 DST301BA61
Drain pan maintenance
are short. using dampers and long ducts. intelligent Touch Controller5 DCS601C51
check window
1
Note: Wiring for wired remote controller to be procured locally. 4
Only one mounting plate can be installed for each indoor unit.
2 5
Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series.
Comfort airflow is achieved in accordance with conditions such as 3
Up to 2 adaptors can be fixed for each mounting plate. The Interface adaptor for SkyAir series is not necessary for this indoor unit since it is equipped as standard.
Easy maintenance because the drain pan can be duct length.
removed
12 13
CEILING SUSPENDED TYPE

Comfortable Airflow Travels


Throughout The Room SPECIFICATIONS
50 60

Model Indoor unit FHQ50BVV1G FHQ60BVV1G


Name Outdoor unit RZR50LVVM RZR60LVVM
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz
Cooling capacity1 kW 5.0 (2.3-5.6) 6.0 (2.6-6.3)
Rated (Min. - Max.) Btu/h 17,100 (7,900-19,100) 20,500 (8,900-21,500)
Power consumption Cooling1 kW 1.39 1.69

Benefits of DA series
COP W/W 3.60 3.56
Colour White
Indoor
Airflow rate (H/L) m3/min 17/-/14
unit
Sound level (H/L)2 dB(A) 39/-/35
Dimensions (HXWXD) mm 195X1,160X680
The technology of the DC fan motor, wide sirocco fan, Machine weight kg 27
and large heat exchanger combine for greater airflow Certified operation range °CWB 14 to 25
and quiet operation. Outdoor
Colour Ivory white
unit Compressor Type Hermetically sealed swing type
High/Middle/Low : 46/42/38 dB(A) Motor output kW 1.12 1.35
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m)
Sophisticated design Sound level Cooling
3 dB(A) 48
Night quiet mode dB(A) 44
Flap neatly closes when Dimensions (HXWXD) mm 595X845X300
not in use. Machine weight kg 43
Certified operation range °CDB 10 to 46
Fresh white colour. Piping Liquid (Flare) mm o/ 9.5
connections Gas (Flare) mm o/ 15.9
Drain Indoor unit mm VP20 (I.D o/ 20XO.D o/ 26)
Installable on ceilings 4.3 m high Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping

100 125 140


Model Indoor unit FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA
3 fan speeds: High/Middle/Low Name Outdoor unit RZR100MYM RZR125MYM RZR140MYM
Connection to a centralised control system Power supply Outdoor unit 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2
is available, without option. Rated (Min. - Max.)
kW 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4)
Btu/h 34,100 (17,100-38,200) 42,700 (19,500-47,800) 47,800 (21,200-52,600)
Power consumption Cooling1 kW 3.03 4.42 5.55
COP W/W 3.3 2.83 2.52
Colour Light Ivory
Comfortable
Indoor
unit Airflow rate (H/M/L) m3/min 28/24/20 31/27/23 34/29/24
Sound level (H/M/L)2 dB(A) 42/38/34 44/41/37 46/42/38
Auto swing (up and down) and louvers (left and right Dimensions (HXWXD) mm 235X1,590X690
Machine weight kg 38
by hand) bring comfort to the room Certified operation range °CWB 14 to 25
Colour Ivory white
Outdoor
Louver manually adjusts unit Compressor Type Hermetically sealed swing type

for straight or wide angle Refrigerant charge


Motor(R-410A)
output kW 1.92
Refrigerant charge (R-410A) 1.9
airflow kg (Charged for 30 m)
Cooling dB(A) 49 52 54
Sound level3
Night quiet mode dB(A) 45 46
Programme “Dry” Dimensions (HXWXD) mm 990X940X320
Machine weight kg 73
Dehumidification is a microprocessor controlled to prevent Certified operation range °CDB 21 to 46
abrupt and uncomfortable changes in air temperture. Piping Liquid (Flare) mm o/ 9.5
connections Gas (Flare) mm o/ 15.9
Drain Indoor unit mm VP20 (I.D o/ 20XO.Do/ 26)

Easy Maintenance
Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Long-life filter (standard) requires no maintenance for Heat insulation Both liquid and gas piping
Quiet Operation at 32** dB(A) about 1 year* Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
**Selected models only 2
The filter is washable and reused after 1 year. Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3
* For dust concentration of 0.15 mg/m

Uses quiet stream fan and other quiet Two time settings (2500 hrs and 1250 hrs) are available to match the installation
technologies.
environment. Maintenance time warning is displayed on the remote controller OPTIONS
(filter sign).
(FHQ50-125BV) Kit name
Easy-clean, flat surfaces Name of option Remark
FHQ50/60BVV1G FHQ100BVV1B FHQ125BVV1B FHQ100/125/140DAVMA
Replacement long-life filter Resin net KAF501DA80 KAF501DA112 KAF501DA160 KAFP501A160
Drain pump kit KDU50N125VE KDU50P140VE
Turbulent flow
is reduced
Straightening plate Quiet stream fan Drain pump kit can be easily Remote controller Wireless type
Wired type1
Cooling only BRC7EA66
BRC1C61
BRC7GA56

incorporated
Navigation Remote Controller Wired type1 BRC1E62
Wiring adaptor for electrical appendices2 KRP4AA52

Oil Resistant Grille Drain pump kit (option) includes 600


Interface adaptor for SkyAir series
Installation box for adaptor PCB
DTA112BA51
KRP1CA93
N/A
KRP1D93A

Oil-resistant plastic is used for the air suction grille.


1
Note: Wiring for wired remote controller to be procured locally.
a silver ion antibacterial agent mm 2
Installation box for adaptor PCB (KRP1D93A) is necessary.
This satisfies durability in restaurants and other similar that assists in preventing the
environments. growth of slime, bacteria and Drain pump kit
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification mould that cause smells and (built inside
is not suitable for kitchens or other harsh environments. main unit)
clogging.
14 15
WALL MOUNTED TYPE

Compact Design and Easy Installation SPECIFICATIONS


100
Model Indoor unit FAQ100CVEA
Name
Outdoor unit RZR100MYM
Power supply Outdoor unit 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 kW 10.0 (5.0-11.2)
Rated (Min. - Max.) Btu/h 34,100 (17,100-38,200)
Power consumption Cooling1 kW 3.37
COP W/W 2.97
Colour Fresh white
Indoor
Airflow rate (H/M/L) m3/min 26/23/19
unit
Sound level (H/M/L)3 dB(A) 49/45/41
Dimensions (HXWXD) mm 340X1,200X240

Comfortable
Machine weight kg 17
Certified Operation range °CWB 14 to 25
Colour Ivory white
Outdoor
• Auto swing unit Compressor Type Hermetically sealed swing type
Motor output kW 1.92
Refrigerant charge (R-410A) kg 1.9 (Charged for 30 m)
Wide-angle louvers Sound level 3 Cooling dB(A) 49
Night quiet mode dB(A) 45
(by hand) Dimensions (HXWXD) mm 900X940X320
Soft material louver Machine weight kg 73
Certified Operation range °CDB 21 to 46
bends airflow over mm o/ 9.5
Piping Liquid (Flare)
a wider area connections Gas (Flare) mm o/ 15.9
Drain Indoor unit mm VP13 (I.D o/ 13 X O.D o/ 18)
Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70m)
Auto-swing 5-level air direction setting Max. installation level difference m 30
Heat insulation Both liquid and gas piping

Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Gettable to 5
different levels

OPTIONS
Kit name
Name of option Remark
FAQ100CVEA
Drain-up kit K-KDU572EVE
Remote controller Wireless type Cooling only BRC7EB519
Wired type1 BRC1C61
Navigation Remote Controller Wired type1 BRC1E62
• Switchable fan speed : High / Middle / Low Wiring adaptor for electrical appendices KRP4AA51
Installation box for adaptor PCB KRP4AA93
Compact & Sophisticated Design • Auto airflow rate (When BRC1E62 is used) Note: 1Wiring for wired remote controller to be procured locally.

• FAQ100 • Programme "Dry"


Dehumidification is microprocessor controlled to prevent
9kg lighter FAQ100BV FAQ100C abrupt and uncomfortable changes in air temperature.
Height 360mm 340mm
340
mm Width 1,570mm 1,200mm

1,200mm
Depth 200mm 240mm Drain Pump Kit is Available as
Weight 26kg 17kg Option.
Installs onto side of unit.

Easy Cleaning Height of drain up


Refrigerant
• Removable and washable grille piping
1,000 mm

Indoor unit
Drain pump kit

Connection to a centralised control system


• Flat panel, easy to wipe dust off is available without option

16 17
Functions
Functions
CEILING MOUNTED CASSETTE TYPE DUCT CONNECTION MIDDLE and CEILING SUSPENDED TYPE WALL MOUNTED TYPE
Round Flow HIGH STATIC PRESSURE TYPE

overview
overview NEW NEW FHQ50/60BVV1G NEW
Cooling only Indoor unit FCQ50-71LUV1 FCQ100-140KAVEA FBQ50-140EVE FHQ100-140DAVMA FAQ100CVEA
RZR50-60LVVM RZR50-60LVVM,RZR71LVVMG
RZR100-125MVMG,
Outdoor unit RZR100-125MVMG, RZR50-60LVVM RZR100-140MYM RZR100MYM
RZR71LVVMG RZR100-140MYM RZR100-140MYM
Auto swing
Swing pattern selection
Independent up-and-down airflow
DC fan motor (Indoor unit)
Switchable fan speed 2step 3step 3step 2step 3step for DA 3step
Auto airflow rate *1
Comfort
High fan speed mode
Program “Dry”
High ceiling application *6 *6
Two selectable temperature-sensors *2

Year-round cooling applicable


Night quiet operation *3

Setpoint auto reset *1


Setpoint range set *1
Remote Weekly schedule timer *1
Controller
Off timer (programmed) *1
On/Off timer *4

Anti-bacterial air filter *8


Mould-proof air filter
Cleanliness
Silver ion anti-bacterial drain pan
Mould-proof drain pan

Drain pump mechanism *8 *8 *8


Pre-charged for up to 30 m *3

Pre-charged for up to 10 m *3

Long-life filter *8
Work & Filter sign
servicing
Ceiling soiling prevention
Low gas pressure detection *3

Emergency operation
Self-diagnosis function

Auto-restart
Control by 2 remote controllers
Group control by 1 remote controller
Control External command control *8 *8 *8 *8 *8 *8
features *8 BV series
Central remote control needs option
Interlock control with Heat Reclaim Ventilator
DIII-NET communication standard Only for DA series

High-efficiency filter
Options Ultra long-life filter
Fresh air intake kit Only for DA series

Others Anti corrosion treated heat exchangers *3 *10 *10 *10

Note: *1 : Applicable when BRC1E62 is used *3 : For outdoor units *5 : Applicable for FVQ50-100 *7 : Installable on max. 4.3 m high ceiling *9 : Applicable for 60/71 class indoor unit
*2 : Applicable when wired remote controller is used *4 : Applicable when BRC1C61 is used *6 : Installable on max. 3.5 m (50-71) *8 : Option *10 : Applicable for RZR50-71M, RZR-LV and RZR-LU
and 4.3 cm.(100-140 ) high ceiling

18 19
Work and Servicing
Drain pump mechanism Ceiling soiling prevention function
Comfort Steeper gradient realises more Daikin's innovative air discharge mechanism keeps airflow
efficient condensate drainage. away from the ceiling. Ceiling cleaning is less frequently
Auto-swing Programme "Dry" High-lift is especially useful for required.
Delivers comfortable The air flow direction can be Dehumidification is microprocessor controlled to prevent long lengths of drain piping.
air-conditioning to all areas, near fixed at your desited angle abrupt and uncomfortable changes in air temperature. Useful Low gas pressure detection
to and far from the by the remote controller. for reducing uncomfortable humidity without uncomfortable
air-conditioner. cooling of the room. Pre charged for up to 30 metres Insufficient gas charging is normally hard to detect. During
post-installation trials and regular inspection procedures, the
Swing pattern selection If refrigerant piping length does not exceed 30 m, there is no refrigerant level is monitored by microprocessor to maintain
High-ceiling application need for on-site gas charging. proper gas pressure. Reliability is assured and maintenance
You can freely set air discharge setting by remote controller.
*Applicable to RZR50-140. and inspection can be carried out more quickly.
Delivers air-conditioning comfort all
(1) Air direction (2) Air direction in (3) Air direction in RXS50FA/60F/71F,RKS25A/35A : 10 m
the way down to the floor in
in standard
setting
draft prevention
setting
ceiling soiling
prevention setting
air-conditioning zones with high Emergency operation
ceilings. Long-life filter If there is a malfunction elsewhere in the system, the fan or
Maintenance is not required for one year*. compressor can still be operated.
The filter is washable and can be reused.
Note: When units are installed on high ceilings, depending on the model,
various restrictions concerning maximum height, air discharge direction,
*For dust concentration of 0.15 mg/m3 Self diagnosis function
and choice of options may apply.
The operating parameters of indoor and outdoor units, and
Independent up-and-down airflow Filter sign sensor data at critical locations throughout the system, are
Independently adjust (manually) the eight horizontal blade Two selectable temperature-sensors The filter sign warns you when it is time to clean the filter. constantly monitored using a microcomputer. To facilitate
louvers in both up and down directions to achieve an airflow that Temperature-sensors are included in the indoor unit and *When using a wired remote controller the sign is displayed in the LCD. quick response in the event of a malfunction, a message
reduces uneven room temperature. optional wired remote controller. Temperature sensing closer When using a wireless remote controller the filter sign lamp illuminates on appears on the LCD of the remote controller and an LED on
the signal receiver unit. the unit illuminates.
to target area is possible to further increase the comfort level.
Switchable fan speed Use the temperature-sensor in
the indoor unit when controlling
High setting provides maximum reach while low setting minimises drafts. air conditioning from another
room. Control features
Auto airflow rate Note: Wireless remote controllers have no
temperature-sensor.
Auto-restart External command control
Airflow rate is automatically controlled in accordance with the
difference between room temperature and set temperature. If there is a power outage while the equipment is operating, Operation and surveillance is carried out using the contact signal from
operations will restart in the same mode as before the power the operation control box in the building surveillance (security) room.
Night quiet operation cut when electricity is restored. *An option is required.
High fan speed mode The Automatic night quiet mode will initiate 8 hours after the
You can increase fan speed approximately 10% higher than the peak temperature is reached in the daytime, and normal Central remote control
"high" setting. operation will resume 10 hours after that. Control by 2 remote controllers
Optional central remote controller enables centralised control of
Using 2 remote controllers you can operate the equipment up to 1024 indoor units (64 groups) from up to 1 kilometer away.
locally or from a remote location.

Remote Controller Note: It is not possible to use two wireless remote controllers.
Interlock control
Enables interlocking control with external equipment such as
Setpoint auto reset Off timer (programmed) Group control by 1 remote controller Heat Reclaim Ventilator.
Even if the set temperature is changed, it returns to the preset Sets and saves setting for an increment of time that You can turn up to 16 indoor units on/off with a single remote
temperature after a preset period of time. automatically turns off air conditioner after a preset period of controller. (When using connected indoor units, the settings DIII-NET communication standard
time for each time operation starts. must all be the same and on/off will be simultaneous.) Standardly equipped interface enables connection to
Setpoint range set centralised control system without need of an adaptor.

Saves energy by limiting the minimum and maximum set On/Off timer
temperatures. Avoids excessive heating and cooling.
Operation starts when the preset time of the ON timer elapses
and stops when the preset time of the OFF timer elapses.
Options
Weekly schedule timer
High-efficiency filter unit Fresh-air intake kit
Up to five operation ON/OFF settings can be programmed per
day for each day of the week. Not only can the time be set for Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside.
the operation ON setting, but also the temperature. Convenient for places where a ventilation fan cannot be
installed.
Ultra long-life filter
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required,
Requires no maintenance for about 4 years* (10,000h) in be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is

Cleanliness stores and offices.


*For dust concentration of 0.15 mg/m3
required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited to
10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will
increase the operating noise and may also influence temperature sending.

Anti-bacterial air filter Mould-proof air filter


The Air filter has a anti-bacterial treatment to help prevent the
growth of bacteria and mould on it.
Sanitary filter has mould-resistant treatment.
Others
Mould-proof drain pan Silver ion anti-bacterial drain pan Anti corrosion treated heat exchangers
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat
Mould-proof drain pan prevents growth of mould in highly Mould-proof drain pan includes a silver ion antibacterial agent
exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
humid conditions. that assists in preventing the growth of slime, bacteria, and
In high corrosive areas, regular maintenance needs to be carried out.
mould that cause smells and clogging.

20 21
LCD REMOTE CONTROLLER Optional accessory

Wired LCD remote controller


Easy-to-read LCD remote controller allows various system control configurations
and can control multiple indoor units.
Easy to read because of large LCD screen.
Navigation Remote Controller (Wired Remote Controller BRC1E62)
The rubber switch and the oil-resistant plastic
casing are adopted for durability.
Only 17 mm thick. Can be installed either recessed
or exposed.
This simple, modern designed remote controller with
fresh white colour matches your interior design. BRC1C61
Operation is much easier and smoother, just follow
the indications on the navigation remote controller.

LCD wireless remote controller

The wireless remote controller is supplied


Clear Display with Backlight Convenience
in a set with a signal receiver.
Backlight Weekly Signal receiver unit is contained inside
display schedule decoration panel or indoor unit
BRC7GA56 Shape of signal receiver unit differs
Signal receiver unit
(For FHQ140CA)
according to the indoor unit.
Note: The signal receiver unit shown in the photograph is for mounting inside the decoration
panel of the ceiling suspended type.

Wireless remote
Energy saving controller

Setpoint auto reset


- Even if the set temperature is changed, it returns to the preset temperature after apreset period of time.
- Period selectable from 30min/60min/90min/120min. Easily adaptable to large-scale, high-function, centralised remote control system.
Restaurant sample

Restaurant opened Full tables at lunchtime After 30 minutes* Central remote controller Unified on/off controller Schedule timer
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset
crowded room temperature (27ºC) DCS302CA61 (Option) DCS301BA61 (Option) DST301BA61 (Option)
Returns to DCS601C51 (Option)

27°C 24°C 27°C


automatically

*Setting possible for after 30, 60, 90, and 120


minutes.

Off timer (programmed)


- Sets and saves setting for an increment of time that automatically turns off air
Centralised control, with setting Centralised control of on/off by Unified control of weekly With its high functionality, the
conditioner after a preset period of time for each time operation starts.
as simple as it is with a standard group or all at once for up to schedule for up to 1,024 indoor full colour “all-in-one” graphic
- Period can be preset from 30 to 180 minutes in10-minute increments. remote controller, of up to 64 256 indoor units. units. controller facilitates
groups (1,024 indoor units) is Schedule timer sets on/off time in 1 minute management of SkyAir System
units to be executed twice a day for a week
possible. in a variety of ways.
Setpoint range set at a time.

- Saves energy by limiting the min. and max. set temperature.


- Avoids excessive heating or cooling. Interface adaptor for SkyAir series
- This function is convenient when the remote controller is installed at a place where DTA112BA51 (Option) Enables centralised control via connection to a The interface adaptor for the SkyAir series is optional except
any number of people may operate it. high-speed, DIII-NET communication system, adopted for for the ceiling mounted cassette type < Round Flow >,
the Daikin VRV system. duct connection middle static (CA/DA series) pressure type,
Necessary for interface adaptor for SkyAir series with the central remote wall mounted type and floor standing type.
control units shown at above.

22 23