Fan Circuit
SUMITOMO (S.H.I) CONSTRUCTION MACHINERY MANUFACTURING CO.,LTD
Why the hydraulic fan system needed?
Key SW : ON
③ Reverse SW : ON ④ Dust
Dust
Buzzer : ON
Key SW : Start
Throttle : Max
Pump
P – From pump
T – Tank line
Tc – Secondary tank line
Cooling Fan Motor
Pump
Proportional Solenoid
SUMITOMO (S.H.I) CONSTRUCTION MACHINERY MANUFACTURING CO.,LTD
Reversible Fan Circuit - Outline
Outline
When the following error codes are generated, the output current value to
proportional solenoid valve from the controller is adjusted to 0mA (Back-up
operation). There is no way to by-pass the backup operation when the
following error codes have been generated, because of loose connection
etc. might make fan rotation speed instability.
The fan reversing signal is output from the main computer to the on-off solenoid valve
when fan reversing switch (in operators cab) is turned on.
A 24v signal is output to the lever lock relay by the main computer PNP out, the lever lock
solenoid valve is than turned off, and the machine cannot be operated. At this time,
the output current value of main computer PWM out becomes 0mA from 600mA.
When the key switch is turned on in the above, the engine is started in fan reversal mode,
and the fan rotation becomes the maximum speed because the output current
value of main computer PWM out is 0mA.
Note: Please make sure the auto-idle function is off when the fan reverses because the
auto-idle function will still engage. Please open the engine hood to secure the
amount of the air required when the fan reverses.
When the key switch is turned off in the position of the fan reversing mode, the last data is
reset. Therefore, when the key switch is turned on again, it will be the normal mode.
The output current of main computer PMW out can be set to an arbitrary
current value by "OUT" of "RST1 (Reset)" in the monitor between
100mA and 500mA at intervals of 10mA.
Fan speed (min-1)
1400
1200
1000
800
600
400
0 100 200 300 400 500 600
Input current (mA)
BRK RPM AU
AI SEC OUT
RST MODE 2 H
1 PA
BRK RPM AU
AI SEC OUT
For Hydraulic Fan RPM Inspection Mode, the previous data, which you
selected, is reset automatically. Even if the Key switch is switched OFF with
some current value set, the next time the Key switch is switched ON, the
mode is changed to normal mode automatically.
Fan pump
1. Constant displacement gear pump
2. Displacement volume :43.7 cm3
3. Installation Location:Engine PTO
Fan motor
1. Constant displacement piston motor
2. Displacement volume:40.0 cm3
3. Rating pressure:17.8 MPa
4. Maximum speed:1600min-1
Radiator
Mounted the fan motor bracket
Fan
800LX fan
Motor
Relief Valve
Tc T
SUMITOMO (S.H.I) CONSTRUCTION MACHINERY MANUFACTURING CO.,LTD
Reversible Fan Circuit - Motor
Relief Valve
RELIEF VALVE
PROPOTIONAL VALVE
REVERSE VALVE
Pump