OPERATION RANGE
Suitable for customerʼs demand (*1 As option)
Temperature
Chilled water
leaving temperature Lower limit: −5 ºC *1
Low temperature use (Brine)
Cooling water
12 ºC
Cooling Centrifugal compressor
tower
entering temperature Lower limit: Motor Case of
supplying 45℃
Key
(Chilled water temperature: 7°C) Point
Cooling water
pump Condenser Evaporator
10 %( )
a continuous operation Constant
*1
100% – speed (Standard: 100%)
(Standard: 100%–20%)
Chilled water
flow rate control range 100% – 150% *1
(Standard: 100%)
Excess flow rate
1
MICROCOMPUTER CONTROL PANEL
More improved microcomputer
control panel
START STOP
Big
OIL TANK 61.0°C
7.2°C
MOTOR CHW Entering Temp REMOTE
Digital Display
COND. EVAP.
32.0°C
Save
CW ENTER 0.89MPa 0.23MPa CHW ENTER
32.0°C 12.5°C START
Condenser Press
Smooth
OIL
Quick Response
Evaporator Press
0.23MPa
CW LEAVE CHW LEAVE Vane Opening
36.8°C 7.2°C
80.9%
OTHER FEATURES
Application to Low Brine Temperature Cooling Maintenance
Applicable for industrial use and ice storage system by adopting Overhaul interval is 50,000 hour in operating time or 7 years in
two stage compressor. elapsed time, which comes earlier.
Control Function (Option) Water box with hinge is provided as standard scope of supply
for easier maintenance and inspection.
Meeting with BAS (Building Automation System) requirement. Please contact with MTH* about overhaul.
Meeting with control monitoring equipment The above overhaul time and operation time is for reference only.
In case of instantaneous power failure, chiller restarts automatically. Reliability
Stability of lubrication oil level and oil temperature improved with
oil-cooler for refrigerant and high efficient oil recovering system.
Chillers are produced at our factory certificated authentication
ISO 9001 and 14001.
Notes: Cable connection work between chiller and iSCT: customer's scope * 2 PLC: MELCO MELSEC or Modbus
2
Standard Ratings
Constant Speed AART series
Chilled water
Flow rate m3/h 136 163 193 231 Flow rate m3/h 138.8 168.9 193.1 223.2
No. of pass – 3 3 3 3 No. of pass – 3 3 3 3
Pressure drop kPa 105 110 105 111 Pressure drop kPa 107 120 103 103
Piping connection / Piping connection /
Nozzle size inch 6 6 6 8 Nozzle size A 150 150 150 200
Entering °C 29.4 Entering 32
temperature temperature °C
Leaving Leaving
temperature °C 34.5 temperature °C 37
Cooling water
Flow rate m3/h 171 205 243 291 Flow rate m3/h 164.2 199.1 227.4 262.1
Cooling water
No. of pass – 3 3 3 3 No. of pass – 3 3 3 3
Pressure drop kPa 94 109 112 116 Pressure drop kPa 85 79 98 94
Piping connection / Piping connection /
Nozzle size inch 6 6 8 8 Nozzle size A 150 150 200 200
kW(50Hz) 117 144 164 200 Motor output kW(50Hz) 118 141 161 184
Motor output
kW(60Hz) 117 144 164 200 Motor input kW(50Hz) 139 164 186 211
kW(50Hz) 138 167 189 230
Motor input
kW(60Hz) 142 171 192 233
Chilled water
Flow rate m3/h 136 163 193 231 Flow rate m3/h 138.8 156.9 217.2 223.2
No. of pass – 3 3 3 3 No. of pass – 3 3 3 3
Pressure drop kPa 105 110 105 111 Pressure drop kPa 107 101 134 103
Piping connection / Piping connection /
Nozzle size inch 6 6 6 8 Nozzle size A 150 150 150 200
Entering °C 29.4 Entering °C 32
temperature temperature
Leaving 34.5 Leaving
temperature °C temperature
°C 37
Cooling water
Flow rate m3/h 171 205 243 291 Flow rate m3/h 164.2 185.1 255.3 262.1
Cooling water
Starter Panel
Voltage 400 V class 3 kV class 6 kV class Service clearance Service clearance
Front side Back side
Width (W) m 0.8 0.8 (Space for opening door) D (Space for inspection)
W
Dimensions Depth (D) m 1.2 1.5
Height (H) m 2.35 2.35 Notes:
Shipping weight t 0.6 0.8 1. Refer to MTH* drawing “MACHINE LAYOUT”
and “STARTER PANEL OUTLINE”
Front side m H
Service 0.8 0.8 at installation.
Back cover knob
clearance 2. Shipping weight of starter panel is
Back side m 0.5 0.5 approximate weight of standard specification.
Starting method ー Star-delta Reactor (65% TAP)* 3. Design and specifications are subject
to change without notice.
Notes: Auto-transformer (65% TAP) starting as option Channel base
Inverter Panel
Chiller model AART- 25 I 30 I 35 I 40 I
Voltage — 400 V class 6 kV class 400 V class 6 kV class 400 V class 6 kV class 400 V class 6 kV class
Type of inverter panel — — A B — A B — A B — A B
Width (W) m 1.30 3.7 4.1 1.30 3.7 4.1 1.30 3.7 5.1 1.30 4.1 5.1
Dimensions Depth (D) m 0.97 1.3 0.9 0.97 1.3 0.9 0.97 1.3 0.9 0.97 1.4 0.9
Height (H) m 2.56 2.7 2.9 2.56 2.7 2.9 2.56 2.7 2.9 2.56 2.7 2.9
Shipping weight t 0.65 5.1 4.7 0.65 5.1 5.1 0.70 5.1 6.3 0.70 5.5 6.3
Front m 1.10 1.6 1.6 1.10 1.6 1.6 1.10 1.6 1.6 1.10 1.6 1.6
Service
clearance Back m 0.65 0.6 — 0.65 0.6 — 0.65 0.6 — 0.65 0.6 —
Overhead m 0.55 0.6 0.7 0.55 0.6 0.7 0.55 0.6 0.7 0.55 0.6 0.7
Notes:
1. MTH* have 2 type inverter panel in 6 kV and 3 kV class. 2. Please contact with MTH* about 3 kV class.
Type A: Small space type for width Type B: Small space type for depth
Service Service
Service clearance clearance
clearance Front side Back side
Front side (Space for (Space for
(Space for opening door) installation)
opening door)
H H
Notes:
1. Refer to MTH* drawing “MACHINE LAYOUT” and “INVERTER PANEL OUTLINE” at installation. 3. Shipping weight of inverter panel is approximate weight of standard specification.
2. Service clearance must be provided more than above. 4. Design and specifications are subject to change without notice.
No. of pass — 2 2 2 2
Pressure drop kPa 58 65 49 54 62 68 47 53
Piping connection / Nozzle size — 150 150 150 200
Entering temp. °C 30 32 30 32 30 32 30 32
Leaving temp. °C 33.7 / 33.8 37 33.8 37 33.7 37 33.8 37
Cooling water
Flow rate m3/h 185 / 182 192 / 189 257 / 254 272 / 268
No. of pass — 3 3 3 3
Pressure drop kPa 78 / 76 75 / 73 70 / 68 68 / 67 87 / 85 84 / 82 73 / 71 71 / 69
Piping connection / Nozzle size — 150 150 200 200
Voltage V 400V class / 3kV class/ 6kV class
System Flow 【Ice Charge Mode (Night)】 System Flow 【Chilled Water Mode (Day)】
Cooling tower Cooling tower
Centrifugal compressor Centrifugal compressor
Motor Motor
Cooling water pump Condenser Evaporator Cooling water pump Condenser Evaporator
P -5°C P 5°C 9.1°C
-2°C 9.1°C
Expansion valve
Centrifugal chiller Brine pump Ice Centrifugal chiller Brine pump Ice
P P
Storage Storage
Tank Tank
Chilled water pump Chilled water pump
P P
No. of pass — 3 3 3 3
Pressure drop kPa 105 93 106 100
Piping connection / Nozzle size — 150 150 150 200
Flow rate m3/h 181 / 180 187 196 / 194 202 253 / 251 261 290 / 289 297
No. of pass — 3 3 3 2 3
Pressure drop kPa 78 / 77 74 75 / 74 71 87 / 86 29 85 80
Piping connection / Nozzle size — 150 150 200 200
Voltage V 400V class / 3kV class/ 6kV class
Key
Point
Cooling water
pump Condenser Evaporator
Air handling unit
Chilled
P 7°C water
Notes:
P
P 1. Power source applicable : 400V class, 3kV class and 6kV class.
Hot water 12°C Chilled water 2. In case of there are two specifications in table,
pump 45°C pump
Left side : Specification of constant speed drive chiller (AART)
Expansion valve Right side : Specification of variable speed drive chiller (AART-I)
3. Design and specifications are subject to change without notice.
Centrifugal chiller
5
Scope of Supply
○: Standard scope of supply △: To be supplied as option
× : Not within scope of work of supply —: Not available
Item Specifications AART AART-I
Indoor type (including control panel) ○ ○
Chiller Assembly
Outdoor type (including control panel) △ △
Compressor Hermetic, two-stage, centrifugal type ○ ○
Compressor Motor Liquid refrigerant cooled, hermetic, squirrel cage, 3-phase, induction type motor, 2 pole, insulated grade B ○ ○
Step-up Gear Integrated inside compressor housing, single helical gear ○ ○
Trochoid pump with submerged motor, refrigerant cooled oil cooler, single oil filter, oil heater with temperature control ○ ○
Lubrication System
Double oil filter △ △
Japanese High Pressure Gas Safety Law and JIS ○ ○
Horizontal shell and tube type with copper tube (3/4"OD) Design pressure of water box: 1.0 MPa (G) ○ ○
Evaporator & Marine type water box with hinge ○ ○
Condenser Tube material other than copper (ex: cupronickel, admiralty brass, titanium) △ △
Tube sheet material other than steel (ex: naval brass clad steel, titanium clad steel) △ △
Design pressure of water box: Over 1.0 MPa (G) △ △
High condensing pressure, Low evaporating pressure, Low oil pressure, Low chilled water outlet temperature,
Safety Device Low chilled water flow rate, Low cooling water flow rate, High oil temperature, High compressor motor coil temperature, ○ ○
Low voltage, Compressor motor over load
Mounted on heat exchanger, indoor non hazardous type with color liquid crystal display,
Microcomputer
lamps and control switches on microcomputer operation board ○ ○
Control Panel
Equipment
※ Prepare 200/220 V three-phase as an auxiliary power. In case of other voltage, consult with MTH*.
Self standing, indoor, non hazardous type with a multi meter ○ ○
Self standing outdoor, hazardous type with a multi meter △ ̶
Starting method 【low voltage】 Star-delta, 【high voltage】Reactor ○ ̶
Starting method 【low voltage】 Reactor, Auto-transformer, Direct on line Starting, 【high voltage】Auto-transformer, Direct on line △ ̶
Starter Panel(AART) Starting method 【low/high voltage】 Inverter ̶ ○
Inverter Panel(AART-I) Installer Breaker AART:ELCB of low voltage. PF of high voltage, AART-I: ELCB of low voltage. VCB of high voltage ○ ○
Capacitor for power factor improvement △ ̶
10, 11 kV/50 Hz power for compressor motor △ ̶
Tie transformer for control power (ex: 400/200 V) △ △
Refrigerant HFC134a in pressure bottles for one (initial) charge ○ ○
Lubrication Oil Ester oil in can for one (initial) charge ○ ○
A thermometer of oil reservoir, Sight glasses, Pressure gauges of condenser, evaporator and oil pressure,
Rubber pad of vibration isolating, Special insulation tape of compressor motor terminal, ○ ○
Flow switch of chilled water and cooling water
Accessory
Foundation bolt △ △
Spring pad for vibration isolating △ △
Charging hose for refrigerant △ △
General tool and tool box △ △
Spare Part An oil filter element, A filter drier, A fuse for control panel ○ ○
Test in accordance with JIS B8621 ○ ○
Shop Test
△ △
Test
Finish coat
Control Panel Rust preventing and finish coat (color: Munsel 5Y7/1) ○ ○
Starter Panel(AART)/Inverter Panel(AART-I) Rust preventing and finish coat (color: Munsel 5Y7/1) ○ ○
Not provided (Purchaser's scope. Instruction for insulation to be submitted.)
̶ ̶
Insulation of Chiller Please follow our INSULATION PROCEDURE.
Polystylen form covered by Colored steel sheet 0.3 mm △ △
FOB Kobe port in Japan ○ ○
Delivery Ex warehouse at Kobe port in Japan (on truck) △ △
CIF port near Site △ △
Integrated style ○ ○
Shipping Style of Chiller
Divided style △ △
Foundation Customer's scope × ×
Site Works
Chiller installation, setting of anchor bolt, water pipe and piping works, and cable and wiring works at site △ △
Installation
Supervisor for site installation × ×
Commissioning Supervisor for site commissioning △ △
JIS (Japan Industrial Standard), JEC (Japanese Electrotechnical Committee),
○ ○
JEM (The Standard of Japan Electrical Manufacture's Association)
Code and Standard
DOSH (Malaysia), MOM (Singapore) △ △
ASME ASTM ̶ ̶
100-20%, Controlling compressor inlet guide vane (1st & 2nd stage) and hot gas bypass valve ○ ○
Capacity Control 100-10%, Larger hot gas bypass valve than standard △ △
100-0% × △
Others
www.mhi-mth.co.jp/en/
MTHSS003, (1.0)16-11, F