GEOMESH INTEGRATED

TEST SET CAPABILITIES


Business benefits enabled by intelligent and integrated test set capabilities

Turning Up New 100G Services


To accomplish the successful turn up of new 100G services—
over a new wet plant or as part of the addition of a new 100G
services over an existing wet plant—requires a comprehensive
knowledge of the physical properties of the submarine cable,
as each submarine cable has its own unique performance
personality, by design, to maximize performance, reach, and,
of course, cost.

Submarine cables, which can be several thousands of


Introduction kilometers in length and contain over a hundred undersea
Global network operators previously looking to evolve their repeaters, have limited optimization and tuning capabilities.
transoceanic networks from 10G to 40G are now aggressively Due to their physical inaccessibility, they are predesigned with
deploying 100G-based submarine networks. Moving to 100G set of performance targets before they are actually deployed.
is very advantageous, as it provides a significant increase in As such, network operators must understand the performance
revenue-generating capacity and postpones indefinitely the limit boundaries to properly provision the Submarine Line
need for new and costly submarine cables. As more terabits of Termination Equipment (SLTE), whether it is situated in the
revenue-generating services are carried by existing submarine Cable Landing Station (CLS) or in the inland PoP when
networks, it is an absolute imperative that network operators GeoMesh is implemented. This characterization involves
understand the capabilities and limits of their network assets the measurement of Chromatic Dispersion (CD), Polarization
before, during, and after the turn-up of these new services. Mode Dispersion (PMD), Polarization Dependence Loss (PDL),
Characterizing, commissioning, actively monitoring, and and Q (measurement of the quality of BER). It also includes
troubleshooting traditional submarine and GeoMesh repeater scans for input/output power levels and span loss,
PoP-to-PoP networks using the very latest in coherent optical and completes with end-to-end connectivity tests before new
technology must be simplified for greater adoption, lower services can be reliably deployed with the confidence level
operational and capital expenses, and quicker time to market required to offer and guarantee various Service Level
for new revenue-generating services. One method of achieving Agreements (SLAs).
these seemingly opposing goals is to leverage the very latest
To capture these advanced metrics, highly trained personnel
in integrated test set capabilities at Layers 0, 1, and 2.
must operate many different pieces of sophisticated and very
Ciena is enabling significant opportunities to increase revenues costly test equipment to understand the power profile, as well
by offering market-leading 100G-based transatlantic and as the CD and PMD test equipment itself. This testing process,
transpacific submarine network solutions, but is also providing often referred to as System Line-up And Test (SLAT), is
critical tools such as integrated test sets and real-time performed onsite with certain BER test durations, lasting up to
performance data to proactively and reactively monitor the health a week, meaning the associated costs of adding new services
of transoceanic services. These integrated test set capabilities can be substantial. Once these data have been collected, they
result in immediate savings associated with faster service velocity, can be analyzed to properly understand the specific personality
as well as longer-term savings associated with proactive network of the wet plant and resultant performance possibilities in
health trending and reduced outage times resulting from outage terms of channel count, for example. Ultimately, network
avoidance and rapid troubleshooting capabilities. By ingeniously operators are continually striving toward simplifying and
hiding the inherent complexity of using various complicated shortening the service turn-up cycle to reduce cost while
external test sets, submarine network operators can instead improving service margins. Shortened new service introduction
leverage the integrated test set capabilities offered as part of times mean quicker return on investments.
Ciena’s GeoMesh Networking solution.

W Whitepaper
Proactive Network Health Monitoring at longer distances, submarine cable operators commonly
In the highly competitive world of international wholesale rely upon specialized Coherent OTDR (C-OTDR) equipment.
services, service providers commonly differentiate based on When troubleshooting or repairing a submarine network,
the lowest cost per bit. However, this business model is only the capability to monitor and localize any faults drastically
sustainable if the services are reliable and meet or exceed reduces the repair time and associated costs.
end-customers’ SLA criteria. Offering market-differentiating
uptime requires close, proactive monitoring of the health and
Ciena Understands
performance of a customer’s service, combined with a well- Ciena’s continuing leadership in the submarine networks
defined action plan to minimize the Mean Time to Repair market related to coherent optics developed from the
(MTTR) when unfortunate faults are experienced. company’s deep experience obtained from extensive real-
world network deployments. Over the span of several product
Conventionally, service providers have limited means of
evolutions, increasingly sophisticated instrumentation and
actively measuring the general health of their wavelength
tools have been introduced to assist submarine cable
services and often are only able to take full performance
operators characterize and optimize customers’ services.
snapshots during maintenance windows when they are out of
service. As with turn-up testing, these health measurements Ciena has several new features and tools network operators
require valuable onsite staff and equipment, and are necessary can leverage today to help alleviate the cost and time
to identify service degradations or fluctuations in the end-to- elements described above when deploying, optimizing,
end network that may result in a future service interruption. and troubleshooting coherent-based services over
GeoMesh-based PoP-to-PoP networks.
This is especially relevant in the submarine networks market,
where existing cables with a designed lifespan of twenty-five Photonic Network Capture
years are already well into their teenage years, making them
Ciena’s Photonic Network Capture (PNC) tool remotely
increasingly susceptible to performance degradation as they
captures highly detailed photonic level attributes such as CD,
approach their end of life. Cable operators need ways to be
PMD, Q, and end-to-end latency, while in service, measured
more diligent in monitoring and adjusting the health of these
directly from functionality embedded within Ciena’s WaveLogic
aging wet plants as they continue to accelerate the
3 transponders. This detailed photonic data is used to monitor
deployment of substantial amounts of new bandwidth across
the general health of the PoP-to-PoP network against historical
transoceanic distances.
benchmarks to allow network operators to better understand
and address the health trends of their network assets. As this
Troubleshooting and Repair
tool works in conjunction with Ciena’s OneControl Unified
Troubleshooting and repairing submarine cables is inherently
Management System, experts can easily view and optimize
difficult. Submarine wet plants are rather simple in design to
networks remotely, without incurring the costs of travel or the
minimize points of failure and ensure high reliability, and
cost and complexity of expensive 100G-based test equipment.
therefore have limited adjustment and troubleshooting
PNC also actively notifies operators of degraded health
capabilities. The principle parameter that can readily be
parameters based on user-defined thresholds, allowing
modified is the output power level of the inline optical repeaters.
network operators to proactively adjust and account for
Transoceanic submarine networks can have over
service fluctuations and avoid service outages.
a hundred undersea repeaters that require adjusting, so
the ability to communicate and control these components PNC can also be used to help in the planning of new
is critical to maintaining optimum performance. In the worst case wavelength services, as it inventories existing active services
scenario of a submarine cut, restoration times can be and associated parameters that can be inputted directly into
in the order of weeks to months and are extremely costly, Ciena’s OnePlanner Unified Design System tool. PNC also
as vessels must be deployed to locate, raise, and repair faulty comes with a Web-based interface, so access is available
cable. In this case, with the damage done, the goal of repair regarding the health of the network, anywhere, anytime.
revolves around rapid fault isolation to minimize the time
Using WaveLogic 3 and PNC, service providers reduce the
and cost associated with repairing the submarine cable.
costs associated with service turn-up by minimizing test
The majority of the submarine cable cuts occur close to shore
equipment required and proactively ensuring the optimal
where an Optical Time Domain Reflectometer (OTDR) is effective
health and longevity of submarine wet plants.
for isolating the fault at distances less than 200km. However,

2
>  Deep photonic inspection including Coherent Rx Optical Supervision Business Benefits
periodic and on-demand monitoring of key network Submarine Networks Fault Localization
> 
parameters: CD, PMD, Q
Remote Supervision
> 
> Continuous optimization for best performance
> Trending analysis networking benefits:
- Adjust system margin to account for fluctuations Inline submarine repeaters
- Troubleshoot recurring events
- Network expansion planning

OSIC Equipped OSIC Equipped


SLTE SLTE
Figure 2. Submarine repeater supervision

100GbE/OTU4 Integrated Test Set


GeoMesh incorporates commercially available 100G network
offerings that include integrated 100G test set capabilities
targeted at testing 100G 802.3ba and OTU4 services. This
Integrated Test Set (ITS) feature was specifically designed
to alleviate, or even eliminate, the need for expensive and
complicated 100G test sets. The requirement for highly trained
Figure 1. Photonic Network Capture personnel to operate these complicated test sets, which are
frequently in shortage, is also minimized. ITS functionality
Optical Supervisory and Idler Channel Cards provides many modes of remote operation. For instance, the
Ciena’s Optical Supervisory and Idler Channel Cards (OSIC) ability to loop back far-end equipment located on the other
are used to actively manage third-party optical repeaters in a side of an ocean is possible, including subtending equipment
submarine wet plant by providing a dedicated management such as routers capable of transparent loopbacks. ITS
channel that supports bidirectional communications to facilitate capability also provides a utility to save test results in text-
fault sectionalization. Faults most commonly result from repeater based formats for historical service validation records.
laser health degradation or physical damage to the submerged The wealth of integrated testing capabilities is an ideal
cables, such as being dragged by fishing net or anchor. troubleshooting tool for traditional beach-to-beach submarine
The OSIC can actively detect repeater laser health by monitoring network applications, as well as GeoMesh PoP-to-PoP
the percentage of pump power change to help proactively warn networks where the terrestrial and submarine network
of impending failures. Therefore, when a network operator segments are seamlessly interconnected entirely in the optical
witnesses unexpected increased span loss when compared to domain. ITS effectively removes the requirement for skilled
saved historical data, they can initiate a proactive maintenance
plan to prevent a service outage. In some cases, the active
supervisory channel can also be used to adjust repeater output Integrated Test Set Business Benefits
power to maintain the power budget of the end-to-end Reduce capex by eliminating test sets
> 

network. The majority of submarine cable cuts result in a power Reduced opex via remote testing turn-up services
> 

shunt, which in turn cuts off supervisory control of all repeaters. more quickly
In this case, Ciena provides a passive optical port, where a Perform faster troubleshooting
> 

third-party C-OTDR can be injected for precise fault isolation.


In some shunt fault scenarios, power is maintained as the ocean Integrated 100G / ODU4
itself provides a return path, where fault isolation may be Traffic Generator

determined by identifying all of the responsive repeaters and


focusing on the unresponsive repeaters and associated fiber
spans. By focusing on the geographic data associated with
unresponsive repeaters, network operators can better isolate
Ability to verify partial or complete connectivity path with
the location of faults resulting in faster mean time to repair or without fiber loopbacks including subtending equipment
and lower overall repair costs.
Figure 3. Integrated test set

3
Figure 4. Event-based OTDR tracing

field personnel to be onsite, which, for global networks, usually


means different countries on opposite sides of an ocean, Integrated Raman OTDR Business Benefits
with complicated, expensive, and fragile test equipment. Reduce CAPEX by eliminating test sets
> 

GeoMesh ITS provides fast, accurate, and simple testing Turn-up services more quickly
> 

capabilities that can isolate faults at Layer 0, 1, or 2 quickly.


Perform faster troubleshooting
> 

Integrated Raman OTDR functionality


GeoMesh PoP-to-PoP network deployments are the latest
evolution of global network designs that optically unites
submarine wet plants with terrestrial backhaul networks to
seamlessly connect inland PoPs. In the terrestrial backhaul
segments of a GeoMesh network, Raman amplification can
be implemented to allow services to remain within the optical
domain from inland PoP to inland PoP. Remaining in the optical
domain results in significant reductions in equipment, power,
space, latency, and overall network cost, all of which are hallmarks
of Ciena’s award-winning GeoMesh Networking solution.

Ciena has integrated intelligent OTDR capabilities directly


into its Raman amplifiers for the purpose of rapid, remote fault
isolation, eliminating the need for expensive, dedicated testing
devices and remote support staff. In the event of a terrestrial
backhaul fiber cut, the intelligent OTDR automatically shuts
down the amplifier for protection and safety and autonomously
initiates a trace. This automatic trace is ready seconds after the OTDR
fault is experienced and determines the distance to the fault, Equipped
which field support personnel can leverage to rapidly locate Raman
and repair. Fault restoration times can be reduced further using
the longitude/latitude information of the Raman amplifier
stored in the PNC tool, thus providing the field support team a
starting waypoint for even faster fault isolation. This results in
increased network availability during reduced outage times. 100G
Submarine
Ciena’s integrated OTDR also provides a quick and controlled Cable Landing
turn-up facility by autonomously testing for faults or sources Inland Data Center Station
of signal degradation before amplification is turned on. This
Figure 5. Integrated OTDR functionality
controlled turn-up process eliminates personal safety hazards,
prevents equipment damage, and proactively identifies
service-impacting factors such as dirty connectors.

4
Test Function Purpose Cost Savings

Integrated Test Set Remote End-to-End Validation and Eliminate External Test Equipment
Troubleshooting Travel Avoidance

Photonic Network Capture Remote Pro-active In-service Photonic Eliminate External Test Equipment
Monitoring and Benchmarking Travel Avoidance
Proactive Network Optimization

Optical Supervisory and Remote Proactive In-Service Eliminate External Test Equipment
Idler Channel Card Submarine Device Control and Travel Avoidance
Monitoring Deterministic Submarine Fault
Isolation

Raman optical time-domain Remote Line Testing and Eliminate External Test Equipment
reflectometer Autonomous Troubleshooting Travel Avoidance
Rapid Fault Isolation

Figure 6. Values of GeoMesh integrated test capabilities

Simplifying Network Operations 3. Troubleshooting remotely from and to anywhere


Ciena’s GeoMesh Networking solution was specifically created to on earth
allow global network operators to unite their submarine and 4. Proactively monitor and control end-to-end
terrestrial network assets to enable numerous benefits, such as network health
reduced equipment, complexity, power, space, latency, and cost. 5. Reduction in the MTTR through effective and rapid
To further help network operators reduce the complexity of their fault isolation
networks from an operational perspective; Ciena has
6. Safely deploy new and in-service 100G submarine
commercialized a broad variety of testing capabilities. By
network services
embedding the inherent complexity of accurately making network
measurements at various layers, GeoMesh further simplifies initial 7. Increased differentiation via improved network
network deployment and ongoing maintenance over time. availability
With increasing demands placed on submarine networks,
Ciena has always focused on pushing the boundaries of
immediate and historical knowledge of end-to-end network
network performance and has been able to maintain itself
attributes from Layer 0 to 2 are table stakes for successful
as a recognized packet-optical market leader in part by
transoceanic deployments. GeoMesh’s simple-yet-
gathering, studying, and understanding real data, and
sophisticated real-time photonic data and onboard test and
sharing this data with its customers.
measurement tools allow global network operators to ensure
Using Ciena’s commercially available solutions such as PNC the ongoing health of their submarine and terrestrial network
proactive monitoring, WaveLogic 3 real-time photonic metrics, assets from PoP-to-PoP.
OSIC submarine monitoring and control, 100G ITS, and Raman
OTDR autonomous fault isolation, Ciena’s GeoMesh Ciena may from time to time make changes to the products or specifications contained herein without notice.
customers can enjoy the following substantial benefits: Copyright © 2013 Ciena® Corporation. All rights reserved. WP140 8.2013

1. Reduction of test equipment capital expense


2. Reduction of operational expenses associated with
skilled field personnel