Sie sind auf Seite 1von 4

BUILDING UTILITIES 1: PRELIMS RESIDUAL PRESSURE

CLO 1: MANIFEST THE ABILITY TO KNOW DISCHARGE PRESSURE


THE BASIC PRINCIPLES OF THESE
SYSTEMS IN TERMS OF FUNCTION,
APPLICATION, OPERATION AND SOURCES AND USES OF WATER
MAINTENANCE.
PLUMBING AND SANITARY SYSTEMS
FUNDAMENTALS COLLECTION:

1. INTRODUCTION- CONCEPTS, ADVANTAGES:


PRINCIPLES, DEFINITION OF TERMS DISADVANTAGES:
HISTORY
PLUMBING- COLLECTION:
PLUMBING SYTEM- ADVANTAGES:
-FIRST CHIEF OF THE DISADVANTAGES:
DIVISION OF PLUMBING CONSTRUCTION
AND INSPECTION.
NAMPAP-
MANILA CITY ORDINANCE 2411- COLLECTION:

HOUSE BILL NO. 962- ADVANTAGES:

REVISED PLUMBING CODE OF 1999- DISADVANTAGES:

-PLUMBING LAW OF THE TESTING OF WATER


PHILIPPIBES CHEMICAL ANALYSIS-
BASIC PRINCIPLES OF PLUMBING CODE
2. FUNDAMENTALS OF WATER BACTERIOLOGY-
SUPPLY SYSTEMS
FUNDAMENTAL UNITS OF WATER
TREATMENT AND PURIFICATION
SPECIFIC WEIGHT
ACIDITY
SPECIFIC GRAVITY
CAUSE:
VOLUME
EFFECT:
FLOW
AVERAGE VELOCITY
CORRECTION:
PRESSURE
STANDARD ATMOSPHERIC PRESSURE
HARDNESS
GAUGE PRESSURE
CAUSE:
ABSOLUTE PRESSURE
EFFECT:
VACUUM PRESSURE
STATIC PRESSURE
CORRECTION:
SALT
CAUSE: SILT OR MUD IN THE SURFACE OR REASONS FOR TREATMENT:
GROUND
ALGAE
EFFECTS: DISCOLORATION; BAD TASTE
REASONS FOR TREATMENT:
CORRECTIONS:

CARBON DIOXIDE, HYDROGEN SULFIDE


COLOR
METHOD OF TREATMENT:
CAUSE:
EFFECT:
SUSPENDED MATERIALS
CORRECTIONS:
METHOD OF TREATMENT:

CAUSE: DISSOLVED IRON


BACTERIA
EFFECTS: RED STAINNING ;
METHOD OF TREATMENT:

CORRECTIONS:
CALCIUM AND MAGNESIUM
METHOD OF TREATMENT:
SULFUR
CAUSE:
IRON
EFFECTS:
METHOD OF TREATMENT:
CORRECTIONS:

SULFUR
PATHOGENIC
METHOD OF TREATMENT:
CAUSE:
EFFECTS:
PATHOGENIC GERMS
CORRECTIONS:
METHOD OF TREATMENT:

POLLUTION
ACID
CAUSE:
METHOD OF TREATMENT:
EFFECTS:
CORRECTIONS:
BASIC METHODS OF PURIFICATION
1. AERATION
OBJECTIONABLE ELEMENTS:
2. COAGULATION AND PRECIPITATION
CALCIUM AND MAGNESIUM
REASONS FOR TREATMENT: 3. FILTRATION

4. SEDIMENTATION
INDIRECT PRESSURE DISTRIBUTION
5. CHLORINATION

6. REVERSE OSMOSIS DRAWING:

7. UV RADIATION

8. OZONE

9. NEUTRALIZING TANK

WATER STORAGE AND DISTRIBUTION


SYSTEMS (HOT AND COLD WATER) LEVELS OF SERVICE

DEFFECTS IN WATER DISTRIBUTION LEVEL 1


SYSTEMS
WATER VELOCITY LEVEL 2
CROSS CONNECTION

BACKFLOW LEVEL 3

BACK PRESSURE OR BACK SIPHONING


ACCESS TO WATER SUPPLY FACILITIES
BACKPRESSURE BACKFLOW
LEVEL 1
DOUBLE CHECK VALVE ASSEMBLY

WATER HAMMER
LEVEL 2
WATER HAMMER ARRESTER

EXPANSION LEVEL 3
VISCOSITY

WHAT ARE THE WATER SOURCES IN COLD WATER TANKS


REGION 2? RSW
GRAVITY TANKS
CLASSIFICATION OF PUBLIC WATER TYPES OF GRAVITY TANKS
DISTRIBUTION SYSTEM
WATER TOWER
DIRECT PRESSURE DISTRIBUTION

ELEVATED/OVERHEAD TANK
DRAWING:
DRAWING:
UNDERGROUND WATER TANK/CISTERN
GROUND TANK
PRESSURE/PNUEMATIC TANK
DRAWING:

PARTS OF THE COLD WATER


DISTRIBUTION SYSTEM
1. SERVICE PIPE

2. WATER METER

3. BUILDING MAIN/HORIZONTAL
SUPPLY MAIN

4. RISER

5. BRANCH

6. FIXTURE BRANCH

7. FIXTURE SUPPLY

8. VALVES

9. STORAGE TANKS

Das könnte Ihnen auch gefallen