APPLICATIONS SERVED:
• COOLING
• WASTEWATER
• BIOLOGICAL CONTROL
• PROCESS WATER
• POTABLE WATER
Chloralkali
88% WATER End User 0
Plant 3 1
OX
• Freight cost $$$$ • Truck traffic at the plant
• Delivery cost • Potential spills at the loading site
• Fast degrading Hypochlorite • Efficacy
HYPO
HYPO HYPOCHLORITE
HYPOCHLORITE
MIOX Current
Algaecide Corrosion ELIMINATE pH ADJUSTMENT
Control For alkaline programs where bromine is used, MIOX is
& Biocide effective at elevated pHs
O2
10000
2.5 CI
ACH
2 BLE
1000 1.5
100 1
.5
10
None Detected 0
0 10 30 60 90 120 180 240
Control Hypochlorite Mixed Oxidant
Solution
Contact time with oxidant (min)
Mixed Oxidant Solution OSHA guidline Lethal Dose
Chlorine Dioxide for CIO2 is 19 ppm
Bleach
MIOX DISINFECTION
ELECTROLYSIS CHEMISTRY
PROCESS ELECTRICITY
The electrolytic cell of a MIOX
on-site chemical generator
uses salt combined with water
and electricity to generate
disinfectant at the point of use.
MIOX
ELECTROLYTIC
CELL
OR OR
BRINE SOLUTION
Since this initial installation, Thermal Chicago has upgraded many of their district cooling systems with MIOX
on-site chemical generators for treating cooling water.
After upgrading to a MIOX Mixed Oxidant Solution (MOS) system, NIPSCO’s Senior Chemist said “the U15
condenser was cleaner than we’d ever seen it before, and there isn’t any other change in the system to
explain these results, other than the conversion to this new biocide system.” BEFORE AFTER
HYPOCHLORITE, BROMIDE, ALGAECIDE MIXED OXIDANT SOLUTION
7% INCREASE MW PRODUCTION
THROUGH BIOFILM REMOVAL
A power plant in Puerto Rico was using straight hypochlorite for their cooling tower, which was not effective
at controlling biological growth. Plant heat exchangers were plugged and temperature rose above
manufacturers specifications due to biofouling of the condenser tube sheets which inhibited effective heat
transfer. MIOX’s Puerto Rico channel partner, NTS, installed a MIOX chemical generator at the power plant
cooling tower and started treating the water with Mixed Oxidant Solution (MOS) chemistry. PREPA
witnessed an immediate improvement in temperature and the energy load of the plant started to increase.
After upgrading to a MIOX Mixed Oxidant Solution (MOS) system, PREPA’s Chief Chemist said “efficiencies gain
at this plant alone results in overall savings of roughly $3.4 million a year.”
BEFORE AFTER
SODIUM HYPOCHLORITE MIXED OXIDANT SOLUTION
MIOX ON-SITE GENERATORS
SCALE & CAPACITY
1 or 2 gal/day 4, 6, 8 gal/day 15, 30, 45, 60 gal/day 60, 120, 180, 240, 300 gal/day 1,000 gal/day
12.5% Bleach Equivalent 3.8 or 7.6 L/day 15 - 30 L/day 57 - 227 L/day 227 - 1,135 L/day 3,785 L/day
Water Treatment Capacity 120,000 - 240,000 GPD 480,000 - 960,000 GPD 1.8 - 7.2 MGD 7.2 - 36 MGD 120 MGD
(at 1ppm FAC) 454 - 908 m³/day 1,817 - 3,634 m³/day 6,813 - 27,252 m³/day 27,255 - 136,275 m³/day 454,250 m³/day
3.0 - 3.5 lb salt/lb FAC 3.0 lb salt/lb FAC 3.0 lb salt/lb FAC 2.5 lb salt/lb FAC 3.0 lb salt/lb FAC
Salt Conversion (SCE) 3.0 - 3.5 kg salt/kg FAC 3.0 kg salt/kg FAC 3.0 kg salt/kg FAC 2.5 kg salt/kg FAC 3.0 kg salt/kg FAC
3.5 kW-hr/lb FAC 3.5 kW-hr/lb FAC 3.0 kW-hr/lb FAC 3.5 kW-hr/lb FAC 3.0 kW-hr/lb FAC
Energy Conversion (ECE)
7.7 kW-hr/kg FAC 7.7 kW-hr/kg FAC 6.6 kW-hr/kg FAC 7.7 kW-hr/kg FAC 6.6 kW-hr/kg FAC
4,000 mg/L 3,800 - 5,000 mg/L 4,500 mg/L 4,500 mg/L 4,500 mg/L
FAC Concentration ± 1,000 mg/L ± 1,000 mg/L ± 1,000 mg/L ± 1,000 mg/L ± 1,000 mg/L
Electrical Service 110 VAC to 240 VAC, 1 ph, 110 VAC to 220 VAC 1 ph, 200 - 240 VAC, 1 ph, 480 VAC, 3 ph, 480 VAC, 3 ph,
Requirement (OSG only) 4A - 8A, 50/60Hz 20A, 50/60Hz 30A - 120A, 50/60Hz 100A, 50/60Hz 400A, 50/60Hz
12.5% Bleach Equivalent 25, 50, 75, 100 gal/day 100, 200, 300, 400, 500 gal/day 1,550 gal/day
95 - 378 L/day 378 - 1,892 L/day 5,867 L/day
Electrical Service 200 - 240 VAC, 1 ph, 480 VAC, 3 ph, 480 VAC, 3 ph,
Requirement (OSG only) 30A - 120A, 50/60Hz 100A, 50/60Hz 400A, 50/60Hz